TY - JOUR A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias T1 - Influence of the number of measurements on detecting internal defects using photothermal super resolution reconstruction with random pixel patterns N2 - In this work, the limits of using spatially structured heating combined with subsequent photothermal super resolution reconstruction for the thermographic detection and resolution of internal defects are investigated. The approach is based on the application of modern high-power laser projector technology, which is used to repeatedly project varying spatially structured 2D pixel patterns to photothermally heat the object under test. After processing the generated thermographic data using nonlinear convex optimisation in conjunction with exploiting the joint-sparse nature of the defect signals within the individual measurements, a high-resolution 2D-sparse defect/inhomogeneity map is obtained. The main focus of the investigation is set on the influence of the number of individual measurements on the achievable reconstruction quality. Using numerical simulations based on an analytical representation of the forward solution to the underlying inverse problem, the convergence rate over performed measurements of the achievable reconstruction quality is determined. Finally, all findings are experimentally validated by reconstructing a set of internal defects in an additively manufactured sample. In this work, it is shown that for a variety of different defect separation distances, the projection of 50 different pixel patterns allows for a good trade-off between experimental complexity and reconstruction quality. KW - Super resolution KW - Digital micromirror device KW - Digital light processing KW - Internal defects PY - 2023 DO - https://doi.org/10.1080/17686733.2023.2223392 SN - 2116-7176 SP - 1 EP - 11 PB - Taylor & Francis AN - OPUS4-57778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias ED - Maldague, X. T1 - Detection of internal defects applying photothermal super resolution reconstruction utilizing two-dimensional high-power random pixel patterns N2 - In this work, we report on our progress for investigating a new experimental approach for thermographic detection of internal defects by performing 2D photothermal super resolution reconstruction. We use modern high-power laser projector technology to repeatedly excite the sample surface photothermally with varying spatially structured 2D pixel patterns. In the subsequent (blind) numerical reconstruction, multiple measurements are combined by exploiting the joint-sparse nature of the defects within the specimen using nonlinear convex optimization methods. As a result, a 2D-sparse defect/inhomogeneity map can be obtained. Using such spatially structured heating combined with compressed sensing and computational imaging methods allows to significantly reduce the experimental complexity and to study larger test surfaces as compared to the one-dimensional approach reported earlier. T2 - Quantitative Infrared Thermography 2022 CY - Paris, France DA - 04.07.2022 KW - Thermography KW - Super resolution KW - NDT KW - inspection KW - Internal defects KW - DMD KW - DLP PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-577795 DO - https://doi.org/10.21611/qirt.2022.1005 SN - 2371-4085 SP - 1 EP - 7 PB - QIRT Council AN - OPUS4-57779 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Stand der Normierung in der Thermografie N2 - Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwenderschaft. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und Richtlinien eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normierung vorgestellt. Wir werden zeigen, welche Grundlagennormen und Anwendungsnormen es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden. T2 - Thermographie-Kolloquium 2022 CY - Saarbrücken, Germany DA - 27.09.2022 KW - Thermografie KW - Normung KW - Normierung KW - Standardisierung KW - Zerstörungsfreie Prüfung PY - 2022 AN - OPUS4-55972 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech May, Nelson Wilbur A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias T1 - Robot-assisted infrared thermography for surface breaking crack detection on complex shaped components N2 - Infrared thermography using a focused (spot or line) beam has proved to be effective for detection of surface breaking cracks on planar samples. In this work, we use the same principle, but applied to complex shaped components, like a rail section, a gear, and a gas turbine blade. We use a six-axis robot arm to move the sample in front of our thermographic setup. Several scanning paths and thermographic parameters are explored: scanning speed, density of points in each scanning slice, laser power and camera frame-rate. Additionally, we explore semi-automatic evaluation algorithms for crack detection, as well as 2D-to-3D registration of the found indications. T2 - SPIE Future Sensing Technologies, 2023 CY - Yokohama, Japan DA - 18.04.2023 KW - Complex shaped component testing KW - Flying line thermography KW - Robot-assisted thermography KW - Crack detection KW - Robot path planning KW - 2D/3D thermographic registration PY - 2023 DO - https://doi.org/10.1117/12.2666757 VL - 12327 SP - 1 EP - 3 PB - SPIE Future Sensing Technologies AN - OPUS4-59867 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Aktueller Stand der Normung in der Thermografie N2 - Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden. T2 - DACH-Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - Thermografie KW - Zerstörungsfreie Prüfung KW - Normung KW - Standardisierung PY - 2023 AN - OPUS4-59250 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Aktueller Stand der Normung in der Thermografie N2 - Die Thermografie ist trotz ihrer ausgereiften wissenschaftlichen und technologischen Grundlagen ein noch relativ junges Mitglied in der Familie der zerstörungsfreien Prüfverfahren. Sie erschließt sich aufgrund einer Reihe von Vorzügen eine wachsende Anwendungsgemeinde. Für eine weitere Verbreitung insbesondere im industriellen Kontext spielen Normen, Standards und technische Regeln eine wichtige Rolle. In diesem Beitrag wird der aktuelle Stand der Normung in Deutschland vorgestellt. Wir zeigen, welche Normen und technischen Regeln es für die Thermografie in Deutschland und international gibt und wir wagen einen Blick in die Zukunft. Darüber hinaus lebt auch die Normierungsarbeit von der Beteiligung durch interessierte Kreise. Dies können industrielle und akademische Anwender*innen, Hersteller*innen von Geräten, Forschungseinrichtungen oder Dienstleistungsunternehmen sein. Sie können gern Ihre Bedarfe bezüglich Normierungsprojekten mitbringen und/oder direkt an die Autoren senden. T2 - DACH-Jahrestagung 2023 CY - Friedrichshafen, Germany DA - 15.05.2023 KW - Thermografie KW - Zerstörungsfreie Prüfung KW - Normung KW - Standardisierung PY - 2023 AN - OPUS4-59251 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias T1 - Nondestructive thermographic detection of internal defects using pixel-pattern based laser excitation and photothermal super resolution reconstruction N2 - In this work, we present a novel approach to photothermal super resolution based thermographic resolution of internal defects using two-dimensional pixel pattern-based active photothermal laser heating in conjunction with subsequent numerical reconstruction to achieve a high-resolution reconstruction of internal defect structures. With the proposed adoption of pixelated patterns generated using laser coupled high-power DLP projector technology the complexity for achieving true two-dimensional super resolution can be dramatically reduced taking a crucial step forward towards widespread practical viability. Furthermore, based on the latest developments in high-power DLP projectors, we present their first application for structured pulsed thermographic inspection of macroscopic metal samples. In addition, a forward solution to the underlying inverse problem is proposed along with an appropriate heuristic to find the regularization parameters necessary for the numerical inversion in a laboratory setting. This allows the generation of synthetic measurement data, opening the door for the application of machine learning based methods for future improvements towards full automation of the method. Finally, the proposed method is experimentally validated and shown to outperform several established conventional thermographic testing techniques while conservatively improving the required measurement times by a factor of 8 compared to currently available photothermal super resolution techniques. KW - Thermography KW - Super resolution KW - NDT KW - Inspection KW - Internal defects KW - DMD KW - DLP PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-570551 DO - https://doi.org/10.1038/s41598-023-30494-2 SN - 2045-2322 VL - 13 SP - 1 EP - 13 PB - Nature Research AN - OPUS4-57055 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yagdjian, H. A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias A1 - Gurka, M. T1 - Application of the thermal shock response spectrum (TSRS) methodology to various forms of heat sources by pulse thermography and comparison by using a rotating line scan contour search algorithm N2 - In this paper, we propose a novel contour search algorithm (CSA) for image processing. Its efficacy is evaluated through a comparative analysis with established techniques such as Canny Edge and Snakes: Active contour models, utilizing infrared thermography (IRT) images. Based on the new CSA, we investigate the influence of different pulse shapes on the IRT post-processing methodology, particularly focusing on the thermal shock response spectrum (TSRS), using two different heat sources: xenon flash lamps and a laser. Moreover, this allows for a more precise quantitative comparison of the TSRS with existing IRT post-processing techniques, including pulse phase thermography and thermal signal reconstruction, concerning the detection of defects in composite materials, particularly in carbon fiber-reinforced polymer. A quantitative comparison was performed using the Tanimoto criterion and signal-to-noise ratio. A more detailed analysis is conducted to identify inherent limitations and potential benefits of the new TSRS methodology. We further investigate and experimentally confirm our previous finding on the qualitative correlation between the one-dimensional thermal N-layer model and test data from the TSRS optimization process for defect determination. This correlation can eliminate the time-consuming optimization step, making TSRS a more attractive alternative to common IRT methods and enhancing the quantitative description of defects. KW - Thermography KW - Non-destructive testing KW - NDT KW - Defect identification KW - Laser KW - Contour search PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615056 DO - https://doi.org/10.1063/5.0232015 SN - 1089-7550 VL - 136 IS - 175101 SP - 1 EP - 20 PB - AIP Publishing AN - OPUS4-61505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hirsch, Philipp Daniel A1 - Kunji Purayil, Sruthi Krishna A1 - Lecompagnon, Julien A1 - Hassenstein, Christian A1 - Ziegler, Mathias T1 - Robotergestützte 3D-Scans und Laserthermografie zur Prüfung an komplexen Bauteilen auf Risse N2 - Die Integration von Automation und Robotik in die Prüfprozesse ermöglicht die Untersuchung komplexer Bauteile. Diese Studie präsentiert die robotergestützte Laserthermografie, um Risse in solchen Bauteilen zu identifizieren und analysieren. Diese Technik ermöglicht die automatisierte Rissprüfung welche im Vergleich zur Farbeindringprüfung auf viele, meist manuelle, Arbeitsschritte sowie die notwendigen Chemikalien verzichtet. Zusätzlich wird ein automatisiertes Einscannen der Bauteile mithilfe eines Linienscanners vorgestellt. Dieser Schritt ermöglicht eine detaillierte 3D-Rekonstruktion der Bauteilgeometrie und ermöglicht eine einfache Korrektur von Abweichungen in der Bauteilaufnahme und eröffnet Möglichkeiten zur adaptiven Bahnplanung bei Bauteilverformungen. Die Rückprojektion der gefundenen Risse auf die Oberfläche des Bauteils kann automatisiert erfolgen. Dieser Schritt erlaubt nicht nur die Identifikation der Risse, sondern auch eine genauere Analyse ihrer Geometrie und Lage am Bauteil. Die Kombination von robotergestützter Laserthermografie, automatisiertem 3DScanning und Rückprojektion der Risse auf die Bauteiloberfläche eröffnet neue Möglichkeiten in der zerstörungsfreien Prüfung von komplexen Bauteilen und erweitert damit mögliche Anwendungsfelder. T2 - Jahrestagung der Deutschen Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) 2024 CY - Osnabrück, Germany DA - 06.05.2024 KW - ZFP4.0 KW - Automatisierung KW - Thermografie KW - Laser KW - Roboter PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-604811 UR - https://www.ndt.net/?id=29520 VL - 182 SP - 1 EP - 8 PB - NDT.net AN - OPUS4-60481 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Ziegler, Mathias T1 - Neue Normen und Richtlinien für die Thermografie in der zerstörungsfreien Prüfung N2 - Da die Thermografie als zerstörungsfreies Prüfverfahren noch vergleichsweise neu in der Anwendung ist, beziehen sich die aktuell veröffentlichten und überarbeiteten Normen und Richtlinien im Wesentlichen auf die grundlegenden Prinzipien des Verfahrens und die verschiedenen Anregungs- und Auswertungstechniken, auf die Begriffe und auf die Gerätetechnik. Die grundlegenden Normen zum Prinzip des Prüfverfahrens, zu den Geräten und zu den Begriffen wurden in 2016 grundlegend überarbeitet und als CEN-Normen neu veröffentlicht. Im Anschluss dazu wird in 2017 der überarbeitete Normentwurf zur aktiven Thermografie veröffentlicht. Mit der Bearbeitung einer europäischen Norm zur Laserthermografie wurde begonnen. Auf nationaler Ebene werden zur Zeit Normen zu den verschiedenen Anregungstechniken erarbeitet. Anfang 2017 wurde der Normentwurf zur Impuls-Thermografie mit optischer Anregung veröffentlicht. Geplant sind weiterhin Entwurfsveröffentlichungen zur induktiv angeregten Thermografie sowie zur Lock-in-Thermografie mit optischer Anregung. Parallel dazu wurde die Überarbeitung der Norm zur Thermografischen Prüfung elektrischer Anlagen publiziert. Mit der Richtlinie VDI/VDE 3511 Blatt 4 bis 4.4 gibt es ein anerkanntes Regelwerk für die rückführbare Temperaturmessung und Kalibrierung von Strahlungsthermometern, die bisher für Thermografiekameras fehlte. In 2016 wurde daher die VDI/VDE Richtlinie 5585 Blatt 1 zur messtechnischen Charakterisierung von Thermografiekameras als Entwurf veröffentlicht. In Bearbeitung ist momentan Blatt 2 zur Kalibrierung von Thermografiekameras mit dem Ziel, auch für Thermografiekameras anerkannte Regeln zur rückführbaren Temperaturmessung zu erstellen. Im Beitrag werden die Anwendungsbereiche dieser Normen und Richtlinien vorgestellt und neue zukünftige Anwendungsbereiche in der Fertigung und Instandhaltung diskutiert. T2 - Thermografie-Kolloquium 2017 CY - Berlin, Germany DA - 28.9.2017 KW - Zerstörungsfreie Prüfung KW - Aktive Thermografie KW - Normung PY - 2017 AN - OPUS4-42396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Laser-Thermografie – Von der flächigen zur strukturierten Anregung N2 - Im Bereich der optisch angeregten Thermografie haben sich Blitzlampen (impulsförmig-flächige Erwärmung) und Halogenlampen (moduliert-flächige Erwärmung) für die spezifischen Regime Impuls- und Lockin-Thermografie etabliert. Mittels eines rasternden fokussierten Lasers wird die Flying-spot Laserthermografie z.B. zur Risserkennung (Dauerstrichbetrieb) und die photothermische Materialcharakterisierung (hochfrequent moduliert)implementiert. Durch die Verfügbarkeit neuer Technologien (schnelle und hochauflösende IR-Kameras, brillante innovativer Lichtquellen und performante Datenakquisitions- und Verarbeitungstechnik) wird ein Paradigmenwechsel von den getrennt voneinander stehenden photothermischen und thermografischen Techniken hin zu einer einheitlichen quantitativen Mess-und Prüftechnik ermöglicht, die schneller und präziser ist. Ähnlich wie ein LED-Array, jedoch mit einer um zwei Größenordnungen höheren Bestrahlungsstärke, steht jetzt eine neuartige brillante Laserquelle, das VCSEL-Array (vertical-cavity surface-emitting laser) zur Verfügung, welches die starke Beschränkung der zeitlichen Dynamik der etablierten Lichtquellen aufhebt und gleichzeitig spektral sauber von der Detektionswellenlänge getrennt ist. Es vereint somit das schnelle zeitliche Verhalten eines Diodenlasers mit der hohen optischen Bestrahlungsstärke und dem großen Beleuchtungsbereich von Blitzlampen. Darüber hinaus kann die Erwärmung auch strukturiert vorgenommen werden, da einzelne Bereiche des VCSEL-Arrays unabhängig voneinander angesteuert werden können. Dieser neue Freiheitsgrad ermöglicht die Entwicklung ganz neuer thermografischer ZfP-Verfahren. T2 - Thermographie-Kolloquium 2017 CY - Berlin, Germany DA - 28.09.2017 KW - Thermografie KW - Laser KW - Zerstörungsfreie Prüfung KW - VCSEL KW - Photothermisch PY - 2017 AN - OPUS4-43115 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Myrach, Philipp A1 - Ziegler, Mathias T1 - Online Laser-thermografische Rissprüfung an Stahl bei hohen Temperaturen N2 - Die Detektion bzw. Charakterisierung von Oberflächenrissen in Stahl ist eine herausfordernde Aufgabe für die zerstörungsfreie Prüfung. Dies gilt insbesondere, wenn eine solche Prüfung bereits während der Produktion selbst erfolgen soll. Die hier vorgefundenen Randbedingungen, wie z.B. die hohen Probentemperaturen (>700°C) oder Vorschubgeschwindigkeiten von bis zu 0,9 m/min, machen die Anwendung etablierter und vor allem berührender ZfP-Methoden praktisch meist unmöglich. Laser-thermografische Verfahren können hier eine Alternative bieten, da sie berührungslos und schnell arbeiten. Wir stellen die Ergebnisse einer Weiterentwicklung der Laser-thermografischen Prüfung vor, bei der die Anwendbarkeit bzw. die Übertragbarkeit der Methode auf die Bedingungen der Stahlproduktion untersucht wurde. Neben der Simulation der Produktionsbedingungen im Labor und der experimentellen Untersuchung der entscheidenden Einflussgrößen, wurden umfangreiche FEM-Simulationen durchgeführt. Mit Hilfe dieser theoretischen und experimentellen Ergebnisse wurde das Verfahren auch hinsichtlich der Analyse-Algorithmen weiterentwickelt, um eine zuverlässige und schnelle In-Line Prüfung während des Produktionsprozesses zu ermöglichen. Um zudem die Fähigkeiten der Thermografiekamera für schnelle online-Messungen und ihre Integrierbarkeit in verschiedene Anwendungssysteme zu verbessern, wurde die für die Verarbeitung der Detektordaten erforderliche Non-Uniformity Correction der Pixeldaten auf schneller Spezialhardware innerhalb der Kamera implementiert. T2 - Thermografie-Kolloquium 2017 CY - Berlin, Germany DA - 28.09.2017 KW - Rissprüfung KW - Laserthermografie KW - Thermografie KW - Risse PY - 2017 AN - OPUS4-42922 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Benefits & peculiarities of using highpower lasers for lock-in thermography N2 - Optical lock-in thermography is a completely contactless and very sensitive NDE technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive, do not need any work safety measures and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Altogether using lasers considerably increases the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in testing [1, 2]. We report on the mentioned benefits of using such high-power lasers and analyze the range of materials to be tested using lock-in thermography in dependence on the laser irradiance, the modulation frequency, the infrared camera as well as the optical and thermal material parameters. In this context, we also address a number of systematic errors caused by the use of ideal and non-ideal heat sources. For example, the measured phase angle in lock-in thermography depends on the irradiance and the modulation bandwidth of the source. This in turn has a decisive influence on the uncertainty in the quantification of, e.g. layer thicknesses. T2 - INTERNATIONAL SCHOOL OF QUANTUM ELECTRONICS, 62nd Course, Progress in Photoacoustic & Photothermal Phenomena CY - Erice, Italy DA - 06.09.2018 KW - Thermography KW - Laser thermography KW - Lock-in thermography KW - NDT PY - 2018 AN - OPUS4-46282 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thiel, Erik A1 - Kreutzbruck, M. A1 - Studemund, T. A1 - Ziegler, Mathias T1 - Thermal wave interference with high-power VCSEL arrays for locating vertically oriented subsurface defects N2 - Among the photothermal methods, full-field thermal imaging is used to characterize materials, to determine thicknesses of layers, or to find inhomogeneities such as voids or cracks. The use of classical light sources such as flash lamps (impulse heating) or halogen lamps (modulated heating) led to a variety of nondestructive testing methods, in particular, lock-in and flash-thermography. In vertical-cavity surface-emitting lasers (VCSELs), laser light is emitted perpendicularly to the surface with a symmetrical beam profile. Due to the vertical structure, they can be arranged in large arrays of many thousands of individual lasers, which allows power scaling into the kilowatt range. Recently, a high-power yet very compact version of such a VCSEL-array became available that offers both the fast timing behavior of a laser as well as the large illumination area of a lamp. Moreover, it allows a spatial and temporal control of the heating because individual parts of the array can be controlled arbitrarily in frequency, amplitude, and phase. In conjunction with a fast infrared camera, such structured heating opens up a field of novel thermal imaging and testing methods. As a first demonstration of this approach, we chose a testing problem very challenging to conventional thermal infrared testing: The detection of very thin subsurface defects perpendicularly oriented to the surface of metallic samples. First, we generate destructively interfering thermal wave fields, which are then affected by the presence of defects within their reach. It turned out that this technique allows highly sensitive detection of subsurface defects down to depths in excess of the usual thermographic rule of thumb, with no need for a reference or surface preparation. T2 - 44TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION CY - Provo, Utah DA - 16.07.2017 KW - Laser applications KW - Thermography KW - VCSEL KW - Subsurface defects PY - 2018 SN - 978-0-7354-1644-4 DO - https://doi.org/10.1063/1.5031547 SN - 0094-243X VL - 1949 SP - UNSP 060001, 1 EP - 8 AN - OPUS4-45171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krankenhagen, Rainer A1 - Ziegler, Mathias A1 - Maierhofer, Christiane ED - Maldague, X. T1 - Systematic errors in the evaluation of uncorrected data from thermographic lock-in measurements N2 - Lock-in thermography (LT) is based on the correct evaluation of phase differences between the temperature oscillations at different surface regions of the object under test during periodic heating. Since the usual heating procedures contain a DC component, the actual heating pattern achieved is not harmonic. This causes systematic deviations when phase differences are determined by means of harmonic analysis, e.g. with FFT analysis. The resulting errors depend clearly on the ratio between DC and AC amplitude, which is demonstrated at simulated and experimentally recorded temperature transients. Further experimental LT data obtained by different oscillating energy inputs showed a variety of possible shapes of transients with different DC components. T2 - 14th QIRT Conference CY - Berlin, Germany DA - 26.06.2018 KW - NDT KW - Lock-in Thermography KW - FFT PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-453768 SP - 539 EP - 547 PB - QIRT Council AN - OPUS4-45376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Studemund, T. T1 - Thermography using a 1D laser array – From planar to structured heating N2 - In the field of optically excited thermography, flash lamps (impulse shaped planar heating) and halogen lamps (modulated planar heating) have become established for the specific regimes of impulse and lock-in thermography. Flying-spot laser thermography is implemented by means of a rasterized focused laser, e. g. for crack detection (continuous wave operation) and photothermal material characterization (high-frequency modulated). The availability of novel technologies, i. e. fast and high-resolution IR cameras, brilliant innovative light sources and high-performance data acquisition and processing technology will enable a paradigm shift from stand-alone photothermal and thermographic techniques to uniform quantitative measurement and testing technology that is faster and more precise. Similar to an LED array, but with irradiance two orders of magnitude higher, a new type of brilliant laser source, i. e. the VCSEL array (vertical-cavity surface-emitting laser), is now available. This novel optical energy source eliminates the strong limitation to the temporal dynamics of established light sources and at the same time is spectrally clearly separated from the detection wavelength. It combines the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination area of flash lamps. In addition, heating can also be carried out in a structured manner, because individual areas of the VCSEL array can be controlled independently of each other. This new degree of freedom enables the development of completely new thermographic NDT methods. KW - Thermography KW - Laser thermography KW - Laser KW - Lock-in KW - VCSEL KW - Thermal wave KW - Photothermal PY - 2018 UR - https://www.hanser-elibrary.com/doi/abs/10.3139/120.111209 DO - https://doi.org/10.3139/120.111209 SN - 0025-5300 VL - 60 IS - 7-8 SP - 749 EP - 757 PB - Carl Hanser Verlag CY - München AN - OPUS4-45482 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Lock-in Thermography using High-Power Laser Sources N2 - Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test specimen. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages. T2 - 12th European Conference on Non-destructive Testing CY - Gothenburg, Sweden DA - 11.06.2018 KW - Thermography KW - Laser Thermography KW - Lock-in Thermography PY - 2018 AN - OPUS4-45445 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim T1 - Lock-in Thermography using High-Power Laser Sources N2 - Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test specimen. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowattclass laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. We present current activities with kilowatt-class highpower laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages. T2 - 12th European Conference on Non-destructive Testing CY - Gothenburg, Sweden DA - 11.06.2018 KW - Thermography KW - Laser Thermography KW - Lock-in Thermography PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-454466 UR - http://cdn.ecndt2018.com/wp-content/uploads/2018/05/ecndt-0139-2018.pdf SN - 978-91-639-6217-2 SP - ECNDT-0139-2018,1 EP - 7 AN - OPUS4-45446 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Lock-in Thermography using High-Power Laser Sources N2 - Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz, see Fig.1. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Using the one-dimensional solution to the thermal heat diffusion equation together with the absorptance of the material which is illuminated with a harmonically modulated light source, we can calculate the temperature oscillation at the surface of a solid. As a second step, we calculate the corresponding oscillation of the total thermal emission using Stefan-Boltzmann law as a first order approximation and taking into account the emissivity of the material. Within this framework we can calculate the minimal irradiance of a light source necessary to provoke a measurable signal within a thermographic camera at a noise equivalent temperature difference (NETD) of 30 mK. In Fig. 2 this relationship is displayed for a wide spectrum of modulation frequencies and for a number of different light sources scaled to the same electrical input power and illumination area. Using this figure, it is now easily possible to analyze the range of materials to be tested using lock-in thermography, since only the materials (dotted lines) below the irradiance-vs-frequency curves (solid lines) are heated in excess of the camera’s NETD. This figure clearly shows that laser sources considerably increase the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in texting. We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser Thermography KW - Lock-in Thermography PY - 2018 AN - OPUS4-45447 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Lock-in Thermography using High-Power Laser Sources N2 - Optical lock-in thermography is a completely contactless and very sensitive NDT technique. As an optical source of energy, incandescent (i.e. halogen) lamps are most commonly used because they are relatively inexpensive and offer high irradiances at the test site. However, they are strongly restricted by their low modulation bandwidth with a maximum modulation frequency of only about 1 Hz. The use of high-power kilowatt-class laser sources, e.g. diode laser arrays, pushes this constraint beyond 100 Hz, see Fig.1. This allows for the exploration of the near-surface region of metals and layer systems with better and more accurate penetration depth and depth resolution. Moreover, these lasers are virtually free of any additional thermal radiation that could interfere with the “true” thermal response emitted from the heated sample. In turn, they can be easily used in a one-sided test configuration. Using the one-dimensional solution to the thermal heat diffusion equation together with the absorptance of the material which is illuminated with a harmonically modulated light source, we can calculate the temperature oscillation at the surface of a solid. As a second step, we calculate the corresponding oscillation of the total thermal emission using Stefan-Boltzmann law as a first order approximation and taking into account the emissivity of the material. Within this framework we can calculate the minimal irradiance of a light source necessary to provoke a measurable signal within a thermographic camera at a noise equivalent temperature difference (NETD) of 30 mK. In Fig. 2 this relationship is displayed for a wide spectrum of modulation frequencies and for a number of different light sources scaled to the same electrical input power and illumination area. Using this figure, it is now easily possible to analyze the range of materials to be tested using lock-in thermography, since only the materials (dotted lines) below the irradiance-vs-frequency curves (solid lines) are heated in excess of the camera’s NETD. This figure clearly shows that laser sources considerably increase the application range of lock-in thermography, since especially for metals with a high reflectance and high thermal diffusivity a high irradiance is vitally important to allow for lock-in texting. We present current activities with kilowatt-class high-power laser sources for advanced lock-in thermography and focus on the application of laser arrays that offer a very high irradiation strength over a large sample area beyond the mentioned advantages. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser Thermography KW - Lock-in Thermography PY - 2018 AN - OPUS4-45449 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Burgholzer, P. A1 - Berer, T. A1 - Ziegler, Mathias A1 - Thiel, Erik A1 - Ahmadi, Samim A1 - Gruber, J. A1 - Mayr, G. A1 - Hendorfer, G. T1 - Blind structured illumination as excitation for super-resolution photothermal radiometry N2 - Using an infrared camera for radiometric imaging allows the contactless temperature measurement of multiple surface pixels simultaneously. From the measured surface data, a sub-surface structure, embedded inside a sample or tissue, can be reconstructed and imaged when heated by an excitation light pulse. The main drawback in radiometric imaging is the degradation of the spatial resolution with increasing depth, which results in blurred images for deeper lying structures. We circumvent this degradation with blind structured illumination, combined with a non-linear joint sparsity reconstruction algorithm. The ground-breaking concept of super-resolution can be transferred from optics to thermographic imaging. T2 - Conference QIRT 2018 CY - Berlin, Germany DA - 25.06.2018 KW - Thermography KW - Laser thermography KW - Super resolution PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-454506 SN - 978-3-940283-94-8 DO - https://doi.org/10.1080/17686733.2019.1655247 SP - We.3.A.2, 1 EP - 7 AN - OPUS4-45450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ziegler, Mathias A1 - Thiel, Erik T1 - Wenn die Wärme Wellen schlägt N2 - Mit Laserlicht kann man eine Materialoberfläche berührungslos und schnell moduliert aufheizen. Dabei entsteht eine stark gedämpfte Wärmewelle, die tief ins Material eindringen kann. Erzeugt und überlagert man solche thermischen Wellen auf kohärente Weise, dann kann man damit versteckte Materialfehler zerstörungsfrei und sehr präzise aufspüren. Sogar eine bildgebende Tomografie ist denkbar. KW - Thermography KW - Laser thermography KW - Lock-in thermography KW - NDT KW - Thermal waves PY - 2018 DO - https://doi.org/10.1002/piuz.201801512 SN - 0031-9252 VL - 49 IS - 6 SP - 296 EP - 303 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-46630 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hempel, M. A1 - Ziegler, Mathias A1 - Schwirzke-Schaaf, S. A1 - Tomm, J.W. A1 - Jankowski, D. A1 - Schröder, D. T1 - Spectroscopic analysis of packaging concepts for high-power diode laser bars N2 - Double-side cooled high-power diode laser bars packaged by different techniques on different types of passive heat sinks are analyzed in terms of packaging-induced strain. Reference data from standard devices being single-side cooled only and packaged by conventional soft and hard soldering are also presented. Thermal profiling across the devices complements the results. The most suitable packaging architecture and technique for double-side cooled bars is identified. Measurements of the laser emission near field and electroluminescence pattern provide direct reference to the functionality of the devices. Furthermore, a type of cross calibration of the methods used for strain analysis is made, since all techniques are applied to the same set of bars. This involves micro photoluminescence, micro Raman, and degree-of-polarization electroluminescence spectroscopy. KW - Spectroscopy KW - Semiconductor laser KW - Thermography KW - High-power diode lasers KW - Non-destructive testing PY - 2012 DO - https://doi.org/10.1007/s00339-012-6799-4 SN - 0947-8396 VL - 107 IS - 2 SP - 371 EP - 377 PB - Springer CY - Berlin AN - OPUS4-25789 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pech May, Nelson Wilbur A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias T1 - Robot-assisted crack detection on complex shaped components using constant-speed scanning infrared thermography with laser line excitation N2 - Infrared thermography (IRT) using a focused laser is effective for surface defect detection. Nevertheless, testing complex‐shaped components remains a challenging task. The state‐of‐the‐art focuses on testing a limited region of interest rather than the full sample. Thus, detection and location of surface defects has been less researched. Most attempts require a manual scan of the full sample, which makes it hard to reconstruct the full scanned surface. Here, we introduce a reliable workflow for crack detection and semi‐automated inspection of complex‐shaped components using IRT excited with a laser line. A 6‐axis robot arm is used for moving the sample in front of the setup. This approach has been tested on a section of a rail and a gear, both containing defects due to heavy use. Crack detection is based on the segmentation of thermograms obtained by Fourier transform of sorted temperatures. Moreover, texture mapping is used to visualize a reconstructed thermogram on the 3D model of the sample. Our approach illustrates a reliable process towards the digitalization of thermographic testing. KW - Crack detection KW - Infrared thermography KW - Laser line excitation KW - Robot‐assisted KW - Texture mapping PY - 2024 DO - https://doi.org/10.1002/appl.202400007 SN - 2702-4288 VL - 4 IS - 1 SP - 1 EP - 13 PB - John Wiley & Sons, Ltd AN - OPUS4-60910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Wärmebehandlung und zerstöungsfreie Prüfung: Oberflächenrisse mit der Laser-Thermografie finden T2 - Härtereikongress 2014 CY - Köln DA - 2014-10-22 PY - 2014 AN - OPUS4-32470 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Einsatz von LEDs in der Thermografie T2 - Hamburger NDT Tage 2014 CY - Hamburg DA - 2014-11-12 PY - 2014 AN - OPUS4-32471 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - LED und LASER - Chancen moderner Lichtquellen für die aktive Thermografie T2 - DGZfP Arbeitskreis Halle Leipzig CY - Handwerkskammer zu Leipzig, Borsdorf DA - 2014-12-08 PY - 2014 AN - OPUS4-32472 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - LEDs for Thermographic NDT: Status and Chances T2 - The 12th International Conference on Quantitative InfraRed Thermography QIRT CY - Bordeaux, Frankreich DA - 2014-07-07 PY - 2014 AN - OPUS4-32473 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Einsatz von LEDs in der Thermografie: Status und Chancen T2 - DGZfP Jahrestagung 2014 CY - Potsdam, Germany DA - 2014-05-26 PY - 2014 AN - OPUS4-30987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - LED und LASER - Chancen moderner Lichtquellen für die aktive Thermografie T2 - DGZfP Arbeitskreis CY - Berlin, Germany DA - 2014-03-04 PY - 2014 AN - OPUS4-30988 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Myrach, Philipp A1 - Ziegler, Mathias A1 - Maierhofer, Christiane A1 - Kreutzbruck, Marc ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - Influence of the acquisition parameters on the performance of laser-thermography for crack detection in metallic components N2 - We present a systematic study on the performance of laser-thermography for the detection of surface cracks in metallic components. Scanning a metallic surface with laser causes local heating that is mapped simultaneously by an IR-camera and allows identifying cracks with sub-µm openings. The detectability, however, depends on a number of acquisition parameters (e.g. scanning speed, laser power, IR-camera resolution) that typically relate on each other. Most importantly, the detection-sensitivity of surface breaking cracks is given by a particular combination for the acquisition parameter values. As a result, this sensitivity is adaptable within wide ranges allowing the detection of cracks with openings ranging from 200 to 0.1 µm at testing speeds of 100 to 0.05 cm²/s. By examining artificial as well as fatigue cracks, we demonstrate that the method can be even applied to shiny surfaces with no need of pretreatments, which makes it an entirely contactless, remote and automatable NDT technique. A comparison with magnetic particle testing shows that laser-thermography has the potential to become a strong competitor to conventional surface inspection methods in the future. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Thermography KW - Laser-thermography KW - Crack detection PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 DO - https://doi.org/10.1063/1.4865018 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1581 SP - 1624 EP - 1630 PB - AIP Publishing AN - OPUS4-31260 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Myrach, Philipp A1 - Jonietz, Florian A1 - Meinel, Dietmar A1 - Suwala, Hubert A1 - Ziegler, Mathias T1 - Calibration of thermographic spot weld testing with X-ray computed tomography N2 - The paper presents an attempt for the calibration of an active thermography method that is suitable for the non-destructive evaluation of spot welds. Nowadays, the quality of spot welds is commonly characterised by the application of random chisel tests, which are time consuming, expensive and destructive. Recently a non-destructive testing method by means of active thermography was proposed that relies on the fact that the mechanical connection formed by the spot weld also serves as a thermal bridge between the two steel sheets joined in the welding process. It is shown in this paper that this thermal bridge can be thermographically characterised by extracting a measure for the spot weld diameter and hence the quality of the spot weld. The determination of the absolute value of the diameter hereby relies on a calibration of the testing system, which is performed by means of X-ray computed tomography in this study. The experiments were carried out using different experimental approaches, namely transmission as well as reflection geometry wSetup in reflectionith laser illumination. A comprehensive evaluation of samples produced using different welding currents, hence different quality, was carried out in order to validate the thermographic results. KW - Thermography KW - Spot welds KW - Spot welding KW - Computed thomography KW - Non-destructive testing PY - 2017 DO - https://doi.org/10.1080/17686733.2017.1281554 SN - 1768-6733 SN - 2116-7176 VL - 14 IS - 1 SP - 122 EP - 131 PB - Taylor & Francis CY - London AN - OPUS4-40180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thiel, Erik A1 - Ziegler, Mathias T1 - Subsurface defect localization by structured heating using laser projected photothermal thermography N2 - The presented method is used to locate subsurface defects oriented perpendicularly to the surface. To achieve this, we create destructively interfering thermal wave fields that are disturbed by the defect. This effect is measured and used to locate the defect. We form the destructively interfering wave fields by using a modified projector. The original light engine of the projector is replaced with a fiber-coupled high-power Diode laser. Its beam is shaped and aligned to the projector's spatial light modulator and optimized for optimal optical throughput and homogeneous projection by first characterizing the beam profile, and, second, correcting it mechanically and numerically. A high-performance infrared (IR) camera is set up according to the tight geometrical situation (including corrections of the geometrical image distortions) and the requirement to detect weak temperature oscillations at the sample surface. Data acquisition can be performed once a synchronization between the individual thermal wave field sources, the scanning stage, and the IR camera is established by using a dedicated experimental setup which needs to be tuned to the specific material being investigated. During data post-processing, the relevant information on the presence of a defect below the surface of the sample is extracted. It is retrieved from the oscillating part of the acquired thermal radiation coming from the so-called depletion line of the sample surface. The exact location of the defect is deduced from the analysis of the spatial-temporal shape of these oscillations in a final step. The method is reference-free and very sensitive to changes within the thermal wave field. So far, the method has been tested with steel samples but is applicable to different materials as well, in particular to temperature sensitive materials. KW - Active thermography KW - Structured heating KW - Digital micromirror device KW - Thermal wave field KW - Photothermal PY - 2017 UR - https://www.jove.com/video/55733 DO - https://doi.org/10.3791/55733 SN - 1940-087X IS - 123 SP - e55733-1 EP - e55733-13 PB - MyJoVE Corp. AN - OPUS4-40281 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krishna, S. K. P. A1 - Puthiyaveetil, N. A1 - Kidangan, R. A1 - Unnikrishnakurup, Sreedhar A1 - Ziegler, Mathias A1 - Myrach, Philipp A1 - Balasubramaniam, Krishnan A1 - Purushothaman, B. T1 - Raw data based image processing algorithm for fast detection of surface breaking cracks N2 - The aim of this work is to illustrate the contribution of signal processing techniques in the field of Non-Destructive Evaluation. A component’s life evaluation is inevitably related to the presence of flaws in it. The detection and characterization of cracks prior to damage is a technologically and economically significant task and is of very importance when it comes to safety-relevant measures. The Laser Thermography is the most effective and advanced thermography method for Non-Destructive Evaluation. High capability for the detection of surface cracks and for the characterization of the geometry of artificial surface flaws in metallic samples of laser thermography is particularly encouraging. This is one of the non- contacting, fast and real time detection method. The presence of a vertical surface breaking crack will disturb the thermal footprint. The data processing method plays vital role in fast detection of the surface and sub-surface cracks. Currently in laser thermographic inspection lacks a compromising data processing algorithm which is necessary for the fast crack detection and also the analysis of data is done as part of post processing. In this work we introduced a raw data based image processing algorithm which results precise, better and fast crack detection. The algorithm we developed gives better results in both experimental and modeling data. By applying this algorithm we carried out a detailed investigation Variation of thermal contrast with crack parameters like depth and width. The algorithm we developed is applied for various surface temperature data from the 2D scanning model and also validated credibility of algorithm with experimental data. T2 - QNDE conference 2016 - Review of progress in quantitative nondestructive evaluation CY - Atlanta, GA, USA DA - 18.07.2016 KW - Crack Detection KW - Laserthermografie KW - Thermografie KW - Risserkennung PY - 2017 SN - 978-0-7354-1474-7 DO - https://doi.org/10.1063/1.4974723 SN - 0094-243X VL - 1806 IS - 1 SP - UNSP 140008, 1 EP - 9 PB - AIP Publishing CY - New York AN - OPUS4-39387 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Puthiyaveettil, N. A1 - Krishna, S. A1 - Kidangan, R. A1 - Unnikrishnakurup, Sreedhar A1 - Krishnamurthy, C. V. A1 - Ziegler, Mathias A1 - Myrach, Philipp A1 - Balasubramaniam, Krishnan T1 - In-line laser thermography for crack detection at elevated temperature: A Numerical modeling study N2 - The detection and characterization of cracks prior to damage is a technologically and economically highly significant task and is of very importance when it comes to safety-relevant structures. The evaluation of a components life is closely related to the presence of cracks in it. Laser thermography has already high capability for the detection of surface cracks and for the characterization of the geometry of artificial surface flaws in metallic samples. Crack detection in metallic samples at high temperature is highly significant in present manufacturing scenario. During the casting process of billets, surface cracks form, due to the suboptimal cooling rates. These cracks reduce value of the billet and must be removed using machining process after cooling. This secondary process increases cost of manufacturing. In this work we developed a heat transfer model for laser thermography to study the thermal contrast variation with increase in surface temperature using finite element method (FEM). Here we are mainly concentrating the capability of the scanning laser thermography in crack detection which are in elevated temperature and numerical modeling study of thermal contrast variation of crack with respect increase in metal surface temperature. This study is important to prove the capability of laser thermography for crack detection in elevated temperature. Since we are using High power CW Laser to local heating of the metal surface which can give relatively high thermal contrast even at elevated temperature compare to other heating source. Here we are modeled and simulated 2D laser scanning across a surface breaking crack and developed an algorithm to produce the vicinity of crack. The algorithm we developed applied for various surface temperature data. And validated the credibility of the algorithm with experimental data. T2 - 13th Quantitative Infrared Thermography Conference 2016 CY - Gdansk, Poland DA - 04.07.2016 KW - Thermal contrast KW - Laser thermography KW - Thermography KW - Surface cracks KW - Elevated temperatures KW - FEM PY - 2016 UR - http://www.ndt.net/article/qirt2016/papers/092.pdf DO - https://doi.org/10.21611/qirt.2016.092 VL - 2016 SP - 588 EP - 596 PB - QIRT 2016 Proceedings AN - OPUS4-39105 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thiel, Erik A1 - Kreutzbruck, M. A1 - Ziegler, Mathias T1 - Laser-projected photothermal thermography using thermal wave field interference for subsurface defect characterization N2 - The coherent superposition of two anti-phased thermal wave fields creates a zone of destructive interference which is extremely sensitive to the presence of defects without any reference measurements. Combining a high power laser with a spatial light modulator allows modulating phase and amplitude of an illuminated surface that induces spatially and temporally controlled thermal wave fields. The position and depth of defects are reconstructed from analysis of the Amplitude and Phase of the resulting photothermal signal. The proposed concept is experimentally validated and supported by numerical modeling. KW - Thermal waves KW - Active thermography KW - DMD KW - Spatial light modulator KW - Subsurface defects PY - 2016 UR - http://scitation.aip.org/search?value1=laser+projected+photothermal&option1=all&option912=resultCategory&value912=ResearchPublicationContent&operator8=AND&option8=pub_serialIdent&value8=aip%2Fjournal%2Fapl&qs=true DO - https://doi.org/10.1063/1.4963139 SN - 0003-6951 VL - 109 IS - 12 SP - 123504-1 EP - 123504-4 PB - AIP Publishing CY - Melville, New York AN - OPUS4-37590 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ziegler, Mathias A1 - Myrach, Philipp A1 - Neding, Benjamin ED - J. Grosch, ED - E.J. Mittemeijer, T1 - Wärmebehandlung und zerstörungsfreie Prüfung: Oberflächenrisse mit der Laser-Thermografie finden N2 - Die Thermografie als zerstörungsfreies Prüfverfahren erlaubt das Erkennen einer Vielzahl von Defekten in unterschiedlichsten Werkstoffen. Hierzu ist zum einen eine Energiequelle erforderlich, welche einen Wärmestrom im Werkstück erzeugt, und zum anderen eine Infrarot-Kamera, welche den orts- und zeitabhängigen Temperaturverlauf der Werkstückoberfläche analysiert. Neue Ansätze unter Verwendung von Lasern ermöglichen nun auch die Prüfung auf winzige Oberflächenrisse. Die aktuelle Grenze der Nachweisempfindlichkeit für mittels klassischer Thermografie nur schwer prüfbare hochreflektierende Metalloberflächen liegt mit Rissbreiten und -tiefen bis hinunter in den Sub-Mikrometerbereich und damit im Bereich der fluoreszierenden Magnetpulver- und Eindringprüfung. Dabei sind jedoch weder Verbrauchsmittel, noch eine Oberflächenpräparation notwendig und eine Prüfung kann berührungslos und automatisiert über Entfernungen bis in den Meter-Bereich erfolgen. Bei der Wärmebehandlung und insbesondere beim Randschichthärten mittels Laserstrahlung stehen ebenfalls hochleistungsfähige Energiequellen zur Erzeugung intensiver dynamischer Temperaturgradienten zur Verfügung. Damit eröffnet sich unmittelbar die Möglichkeit der Integration der thermografischen Prüfung in die Fertigung. Der Beitrag stellt die neuesten Entwicklungen der vielversprechenden Laser-Thermografie-Technik vor und zeigt, warum deren Einsatz potentiell die Standardprüfverfahren Magnetpulver- bzw. Eindringprüfung für eine Reihe von Prüfproblemen beerben könnte. KW - Zerstörungsfreie Prüfung KW - Thermografie KW - Infrarot-Sensor KW - Rissprüfung KW - Lasertechnik KW - Nondestructive testing KW - Thermography KW - Thermal infrared sensor KW - Crack inspection KW - Laser techniques PY - 2015 DO - https://doi.org/10.3139/105.110264 SN - 0341-101x SN - 1867-2493 VL - 70 IS - 4 SP - 190 EP - 195 PB - Hanser CY - München AN - OPUS4-34189 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Locating subsurface defects with structured heating using high-power VCSEL-laser arrays N2 - Among the photothermal methods, full-field thermal imaging is used to characterize materials, to determine thicknesses of layers, or to find inhomogeneities such as voids or cracks. The use of classical light sources such as flash lamps (impulse heating) or halogen lamps (modulated heating) led to a variety of nondestructive testing methods, in particular lock-in and flash-thermography. In vertical cavity surface emitting lasers (VCSELs), laser light is emitted perpendicular to the surface with a symmetrical beam profile. Due to the vertical structure, they can be arranged in large arrays of many thousands of individual lasers, which allows power scaling into the kilowatt range. Recently, a high-power yet very compact version of such a VCSEL-array became available that offers both the fast timing behavior of a laser as well as the large illumination area of a lamp. Moreover, it allows a spatial and temporal control of the heating because individual parts of the array can be controlled arbitrarily in frequency, amplitude, and phase. In conjunction with a fast infrared camera, such structured heating opens up a field of novel thermal imaging and testing methods. As a first demonstration of this ansatz, we chose a testing problem very challenging to conventional thermal infrared testing: The detection of very thin subsurface defects perpendicularly oriented to the surface of metallic samples. First, we generate destructively interfering thermal wave fields which are then affected by the presence of defects within their reach. It turned out that this technique allows highly sensitive detection of subsurface defects down to depths in excess of the usual thermographic rule of thumb, with no need for a reference or surface preparation. T2 - 19th International Conference on Photoacoustic and Photothermal Phenomena CY - Bilbao, Spain DA - 16.07.2017 KW - Thermografie KW - Laser KW - Zerstörungsfreie Prüfung KW - Thermography KW - Non-destructive testing PY - 2017 AN - OPUS4-41829 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Das VCSEL-Laser Array – Durch strukturierte Erwärmung mit einer neuartigen Hochleistungslichtquelle verdeckte Defekte thermografisch detektieren N2 - Vertical Cavity Surface Emitting Lasers (VCSELs) sind Diodenlaser, welche Laserstrahlung mit gutem Strahlprofil senkrecht zur Chipoberfläche emittieren. Aufgrund dieser vertikalen Bauweise können sie in großen Arrays zu vielen tausenden einzelnen Lasern zusammengefasst werden. Solch ein VCSEL-Array vereint das schnelle zeitliche Verhalten eines Diodenlasers mit der hohen optischen Bestrahlungsstärke und dem großen Beleuchtungsbereich von Blitzlampen oder LEDs und kann damit potentiell alle herkömmlichen Lichtquellen der Thermografie ersetzen. Darüber hinaus kann der Prüfkörper mithilfe dieser Lichtquelle strukturiert erwärmt werden, da einzelne Bereiche des VCSEL-Arrays unabhängig voneinander angesteuert werden können. Dieser neue Freiheitsgrad ermöglicht die Entwicklung neuer thermografischer ZfP-Verfahren. Wir demonstrieren diesen Ansatz anhand eines für die konventionelle Thermografie nur sehr bedingt lösbaren Prüfproblems, der Detektion vertikal zur Oberfläche ausgerichteter, sehr dünner, verdeckter Defekte in metallischen Werkstoffen. Wir erzeugen hierzu destruktiv interferierende thermische Wellenfelder. Defekte im Einflußbereich dieser thermischen Wellenfelder stören die destruktive Interferenz und erlauben eine hochsensible Detektion bis in Tiefen jenseits der üblichen thermografischen Faustformel, ohne Referenz und ohne Oberflächenbehandlung. T2 - DGZfP-Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - Thermografie KW - Laser KW - Zerstörungsfreie Prüfung PY - 2017 AN - OPUS4-41834 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hempel, M. A1 - Ziegler, Mathias A1 - Tomm, J.W. A1 - Elsaesser, T. A1 - Michel, N. A1 - Krakowski, M. T1 - Time-resolved analysis of catastrophic optical damage in 975 nm emitting diode lasers N2 - Catastrophic optical damage (COD) is analyzed during single current pulse excitation of 975 nm emitting diode lasers. Power transients and thermal images are monitored during each pulse. The COD process is unambiguously related to the occurrence of a “thermal flash” of Planck’s radiation. We observe COD to ignite multiple times in subsequent pulses. Thermography allows for tracing a spatial motion of the COD site on the front facet of the devices. The time constant of power decay after the onset of COD has values from 400 to 2000 ns, i.e., an order of magnitude longer than observed for shorter-wavelength devices. KW - Semiconductor laser KW - Thermography KW - Catastrophic optical damage KW - High-power diode lasers PY - 2010 DO - https://doi.org/10.1063/1.3456388 SN - 0003-6951 SN - 1077-3118 VL - 96 IS - 251105 SP - 1 EP - 3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-21672 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ziegler, Mathias A1 - Hempel, M. A1 - Larsen, H. E. A1 - Tomm, J. W. A1 - Andersen, P. E. A1 - Clausen, S. A1 - Elliott, S. N. A1 - Elsaesser, T. T1 - Physical limits of semiconductor laser operation: A time-resolved analysis of catastrophic optical damage N2 - The early stages of catastrophic optical damage (COD) in 808 nm emitting diode lasers are mapped by simultaneously monitoring the optical emission with a 1 ns time resolution and deriving the device temperature from thermal images. COD occurs in highly localized damage regions on a 30 to 400 ns time scale which is determined by the accumulation of excess energy absorbed from the optical output. We identify regimes in which COD is avoided by the proper choice of operation parameters. KW - Semiconductor laser KW - Thermography KW - Catastrophic optical damage KW - High-power diode lasers PY - 2010 DO - https://doi.org/10.1063/1.3463039 SN - 0003-6951 SN - 1077-3118 VL - 97 IS - 021110 SP - 1 EP - 3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-21741 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hempel, M. A1 - Tomm, J.W. A1 - Ziegler, Mathias A1 - Elsaesser, T. A1 - Michel, N. A1 - Krakowski, M. T1 - Catastrophic optical damage at front and rear facets of diode lasers N2 - Single-pulse tests of the catastrophic optical damage (COD) are performed for three batches of diode lasers with different gain-regions. The tests involve in situ inspection of front, rear, and side of the devices by a thermocamera. Devices with an Al-containing gain-region show COD at the front facet, as expected for strong facet heating via surface recombination and reabsorption of laser light. In contrast, Al-free devices with low surface recombination rates tend to fail at the rear facet, pointing to a different heating scenario. The high carrier density at the rear facet favors heating and COD via Auger recombination processes. KW - Thermography KW - Catastrophic optical damage KW - High power diode lasers KW - Destructive testing KW - Non-destructive testing KW - Auger effect KW - Carrier density KW - Heating KW - Laser beam effects KW - Optical testing KW - Semiconductor lasers KW - Surface recombination PY - 2010 DO - https://doi.org/10.1063/1.3524235 SN - 0003-6951 SN - 1077-3118 VL - 97 IS - 23 SP - 231101-1 - 231101-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-22763 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tomm, J.W. A1 - Ziegler, Mathias A1 - Hempel, M. A1 - Elsaesser, T. T1 - Mechanisms and fast kinetics of the catastrophic optical damage (COD) in GaAs-based diode lasers N2 - COD diagram determined for a batch of broad-area AlGaAs diode lasers. The time to COD within a single current pulse is plotted versus the actual average optical power in the moment when the COD takes place. Full circles stand for clearly identified COD events (right ordinate), whereas open circles (left ordinate) represent the pulse duration in experiments, where no COD has been detected. A borderline (gray) exists between two regions, i. e., parameter sets, of presence (orange) and absence of COD (blue). This borderline is somewhat blurred because of the randomness in filamentation of the laser nearfield and scatter in properties of the involved individual devices. KW - Semiconductor laser KW - Thermography KW - Catastrophic optical damage KW - High-power diode lasers KW - Destructive testing KW - Non-destructive testing PY - 2011 DO - https://doi.org/10.1002/lpor.201000023 SN - 1863-8880 VL - 5 IS - 3 SP - 422 EP - 441 PB - Wiley-VCH CY - Weinheim AN - OPUS4-23624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pagano, R. A1 - Ziegler, Mathias A1 - Tomm, J.W. A1 - Esquivias, I. A1 - Tijero, J.M.G. A1 - O'Callaghan, J.R. A1 - Michel, N. A1 - Krakowski, M. A1 - Corbett, B. T1 - Two-dimensional carrier density distribution inside a high power tapered laser diode N2 - The spontaneous emission of a GaAs-based tapered laser diode emitting at λ = 1060 nm was measured through a window in the transparent substrate in order to study the carrier density distribution inside the device. It is shown that the tapered geometry is responsible for nonuniform amplification of the spontaneous/stimulated emission which in turn influences the spatial distribution of the carriers starting from below threshold. The carrier density does not clamp at the lasing threshold and above it the device shows lateral spatial hole-burning caused by high stimulated emission along the cavity center. KW - Carrier density KW - Gallium arsenide KW - III-V semiconductors KW - Indium compounds KW - Laser cavity resonators KW - Optical hole burning KW - Quantum well lasers KW - Stimulated emission KW - Superradiance PY - 2011 DO - https://doi.org/10.1063/1.3596445 SN - 0003-6951 SN - 1077-3118 VL - 98 SP - 221110-1 EP - 221110-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-23873 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Catastrophic optical damage at front and rear facets of 975 nm emitting diode lasers T2 - CLEO, Conference on Lasers and Electro-Optics CY - Baltimore, MD, USA DA - 2011-05-03 PY - 2011 AN - OPUS4-23785 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlichting, Joachim A1 - Ziegler, Mathias A1 - Dey, Anika A1 - Maierhofer, Christiane A1 - Kreutzbruck, Marc T1 - Efficient data evaluation for thermographic crack detection N2 - We present an all-purpose crack detection algorithm for flying spot thermography which is directly applicable to a thermogram sequence without the need of any additional information about the experimental setup. A single image containing distinct crack signatures is derived in two steps. Firstly, the spatial derivative is calculated for each frame of the sequence and, secondly, the resulting data set is sorted pixel wise along the time axis. The feasibility of the proposed procedure is proven by testing a piece of rail that comprises roll contact fatigue cracks and by comparing the results with magnetic particle testing. KW - Active thermography KW - Laser scanner KW - Railway KW - Roll contact fatigue KW - Open surface cracks PY - 2011 SN - 1768-6733 VL - 8 IS - 1 SP - 119 EP - 123 PB - Lavoisier CY - Cachan Cedex AN - OPUS4-24255 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Kameragestütztes Flying-Spot-Verfahren zur Risserkennung T2 - Thermografie-Kolloquium 2011 CY - Stuttgart, Germany DA - 2011-09-29 PY - 2011 AN - OPUS4-24542 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schlichting, Joachim A1 - Ziegler, Mathias A1 - Pelkner, Matthias A1 - Maierhofer, Christiane A1 - Kreutzbruck, Marc T1 - Kameragestütztes Flying-Spot-Verfahren zur Risserkennung N2 - In dieser Arbeit wird ein kameragestütztes Verfahren zur Flying- Spot-Thermografie vorgestellt. Die Anregung wird über einen Diodenlaser mit einem optischen Scanner realisiert. Bei der Auswertung kommt ein effizienter und robuster Algorithmus zum Einsatz, der direkt auf die mit der Kamera aufgenommene Thermografiesequenz angewendet werden kann, ohne auf eine Synchronisation zwischen Kamera und Lasersystem angewiesen zu sein. Daher eignet sich diese Herangehensweise besonders zur Nachrüstung bestehender Thermografiesysteme. Die prinzipielle Eignung dieser Methode wird anhand einer Messung an einem Schienenstück mit Rollkontaktermüdungsrissen gezeigt. Als Referenzverfahren werden die Magnetpulverprüfung und eine auf GMR (Giant Magnetoresistance)- Sensoren basierende Streufeldmessung herangezogen. Mit dem thermografischen Verfahren konnten sämtliche enthaltenen Fehler erkannt werden. Dabei wurden Risse im mm-Abstand getrennt nachgewiesen, was etwa der geometrischen Auflösung der eingesetzten Kamera entspricht. T2 - Thermographie-Kolloquium 2011 CY - Stuttgart, Germany DA - 29.09.2011 KW - Flying-Spot Thermografie KW - Diodenlaser KW - Rissortung KW - Magnetpulverprüfung KW - GMR-Sensoren PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246220 SN - 978-3-940283-36-8 IS - DGZfP-BB 130 (Vortrag 09) SP - 1 EP - 6 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24622 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Flying laser spot thermography for the fast detection of surface breaking cracks T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 PY - 2012 AN - OPUS4-26763 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Fast Detection of Surface Cracks Using Flying Laser Spot Thermography T2 - Review of Progress in Quantitative NDE CY - Denver, CO, USA DA - 2012-07-15 PY - 2012 AN - OPUS4-26764 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ziegler, Mathias T1 - Hochleistungs-LED für die zerstörungsfreie thermografische Prüfung T2 - DACH Jahrestagung 2012 CY - Graz, Austria DA - 2012-09-17 PY - 2012 AN - OPUS4-26765 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -