TY - CONF A1 - Redmer, Bernhard A1 - Onel, Yener A1 - Ewert, Uwe T1 - Mechanised radiation techniques - an innovative technique of the mobile in-service inspection of circumferential welds T2 - 3rd International Conference "Pipeline Diagnostics" CY - Moscow, Russia DA - 2001-05-21 PY - 2001 SP - I34 AN - OPUS4-1176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Redmer, Bernhard A1 - Onel, Yener A1 - Ewert, Uwe A1 - Lunin, V. A1 - Podobedov, D. T1 - Mechanisierte Durchstrahlungsprüfung - Innovative Techniken zur Bewertung von Rundschweißnähten T2 - Tagung Schweißen und Schneiden ; Große Schweißtechnische Tagung CY - Essen, Deutschland DA - 2001-09-11 PY - 2001 SN - 3-87155-674-2 N1 - Serientitel: DVS-Berichte – Series title: DVS-Berichte IS - 216 SP - 243 EP - 247 PB - Verl. für Schweißen und Verwandte Verfahren, DVS-Verl. CY - Düsseldorf AN - OPUS4-1162 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - 320 kV Mikrofokusröntgenröhre und Flächendetektor, eine Kombination für die 3D-CT? T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2003 CY - Mainz, Deutschland DA - 2003-05-26 PY - 2003 UR - http://www.ndt.net/article/dgzfp03/papers/v27/v27.htm SN - 3-931381-47-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 83-CD SP - 1 EP - 7(?) PB - DGZfP CY - Berlin AN - OPUS4-2874 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Experiences in using a 320 kV micro focus X-ray tube and a large sized amorphous silicon detector for 3D-CT N2 - A novel 3D-CT scanner was set up at BAM to extend the applicability of the X-ray transmission microtomography (µ-CT) to specimens up to 30 cm in diameter. The scanner consists of a bipolar 320 kV micro focus tube and a flat panel detector of amorphous silicon. Minimisation of scattered radiation, control of room and system temperature, and corrective preprocessing on the projection data are necessary to achieve expectable CT images. Statistical evaluations to show the limits and results of CT investigations are reported. T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 UR - http://www.ndt.net/article/ct2003/v06/v06.htm SN - 3-931381-48-X N1 - Serientitel: DGZfP-Proceedings BB – Series title: DGZfP-Proceedings BB IS - 84-CD SP - 53 EP - 59 PB - DGZfP CY - Berlin AN - OPUS4-2875 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - 320kV Microfokusröntgenröhre und Flachdetektor, eine Kombination für die 3D-CT? T2 - DGZfP-Jahrestagung 2003: Zerstörungsfreie Materialprüfung - ZfP in Anwendung, Entwicklung und Forschung CY - Mainz, Germany DA - 2003-05-26 PY - 2003 AN - OPUS4-3805 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Experiences in using a 320kV micro focus X-ray tube and a large sized amorphous silicon detector for 3D-CT T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 AN - OPUS4-3810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckmann, Jörg A1 - Onel, Yener A1 - Finn, Monika A1 - Rehmer, Birgit T1 - Charakterisierung des oxidativen Schädigungsverhaltens infiltrierter faserverstärkter 2D-C/C-Keramiken mit Hilfe der Röntgencomputertomographie T2 - 15. Symposium Verbundwerkstoffe und Werkstoffverbunde CY - Kassel, Deutschland DA - 2005-04-06 KW - Schädigungsuntersuchung KW - Röntgencomputertomographie KW - Oxidation KW - Keramische Verbundwerkstoffe KW - Kohlenwerkstoffe PY - 2005 SP - 421 EP - 426 PB - DGM CY - Kassel AN - OPUS4-7622 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Onel, Yener A1 - Dehn, F. ED - Alexander, M. T1 - Application of X-ray tomography for the verification of damage mechanisms in concrete T2 - International Conference on Concrete Repair, Rehabilitation and Retrofitting CY - Cape Town, South Africa DA - 2005-11-21 KW - Bauwerkssicherheit KW - Betonbau KW - Strukturaufklärung KW - Zerstörungsfreie Prüfung KW - Röntgen 3D-CT PY - 2005 SN - 0-415-39654-9 N1 - Serientitel: Balkema proceedings and monographs in engineering, water and earth sciences – Series title: Balkema proceedings and monographs in engineering, water and earth sciences SP - 170 EP - 171 PB - Taylor & Francis CY - London AN - OPUS4-11595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Onel, Yener A1 - Dehn, F. T1 - Application of X-ray Tomography for the Verifikation of Damage Mechanism in Concrete T2 - Proceedings of the "International Conference on Concrete Repair, Rehabilitation and Retrofitting" CY - Cape Town, South Africa DA - 2005-11-21 PY - 2005 AN - OPUS4-10650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Onel, Yener A1 - Maier, Bärbel ED - Stark, J. T1 - Zeitliche und räumliche Visualisierung des Gefügezustandes und der Transportvorgänge in frostbeanspruchten Normalbetonen T2 - 16. Ibausil - Internationale Baustofftagung CY - Weimar, Germany DA - 2006-09-20 KW - Dauerhaftigkeit KW - Frostbeständigkeit KW - Beton KW - Schadensanalyse KW - Innovative Prüftechnik PY - 2006 SN - 3-00-018263-2 IS - Band 2 SP - 2-0701 - 2-0706 PB - Bauhaus-Univ. CY - Weimar AN - OPUS4-14398 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weise, Frank A1 - Onel, Yener A1 - Goebbels, Jürgen T1 - Analyse des Gefüge- und Feuchtezustandes in mineralischen Baustoffen mit der Mikro-Röntgen-3D-Computertomografie KW - Beton KW - Naturstein KW - Schadensanalyse KW - Innovative Prüftechnik PY - 2007 SN - 0171-5445 SN - 1437-0980 VL - 29 IS - 3 SP - 194 EP - 201 PB - Ernst CY - Berlin AN - OPUS4-15688 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Onel, Yener A1 - Goebbels, Jürgen T1 - Analyse des Gefüge- und Feuchtezustandes in mineralischen Baustoffen mit der Röntgen-3D-Computertomografie T2 - 12. Bauklimatisches Symposium CY - Dresden, Deutschland DA - 2007-03-29 PY - 2007 VL - 1 SP - 395 EP - 405 PB - TU Dresden CY - Dresden AN - OPUS4-14717 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Badde, Aurelia A1 - Michaelis, Matthias A1 - Berger, U. A1 - Onel, Yener A1 - Meinel, Dietmar A1 - Goebbels, Jürgen T1 - Einsatz von mobilen Röntgenuntersuchungsmethoden im Museum - Zwei Fallbeispiele N2 - Zwei Bildhauermodelle aus dem Georg-Kolbe-Museum Berlin standen zur Restaurierung an. Das kleinere, 'Lucino' (1920), 41cm, wurde hochauflösend mit CT gemessen, da mittels CT sowohl der Herstellungsprozeß einer Gipsstatue als auch der innere Zustand, wie Ergänzungen, Klebungen und Armierungen, festgestellt werden können. Aus den CT Bildern ergab sich eine für die vorher vermutete Gipszusammensetzung ungewöhnliche innere Struktur. Mit einer Freihand bedienten Röntgenpistole zur Messung der Röntgenfluoreszenz wurde daraufhin die Zusammensetzung des Materials der Statuette als Terracotta bestimmt. Durch den Einsatz von Helium als Spülmittel konnten auch leichte Materialien nachgewiesen und so eine Unterscheidung zwischen Gips und gebranntem Ton durchgeführt werden. Aus den CT Daten wurde eine virtuelle Darstellung der äußeren Geometrie gewonnen. Ein damit versuchsweise erstelltes Replik (Rapid Prototyping, 3D-Drucker, TU-Berlin) entsprach nicht den Anforderungen des Museums zur Erstellung einer Gußform für eine Bronzekleinserie der Statuette. Die zweite Statue, die 'Große Nacht' (1930) ist mit ihrer Größe von 2,12m und aufgrund des durch korrodierende Metallarmierung verursachten Schadensbildes nicht mehr transportfähig. Eine in-situ Untersuchung mit dem mobilen Tomographen, der in den 1980ern zur Untersuchung von Bäumen gebaut und jetzt mit einem modernen Flachdetektor und einer Röntgenröhre ausgestattet ist, wird vorgestellt. Die Möglichkeiten der in-situ CT für große Skulpturen werden anhand der Ergebnisse diskutiert. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Mobile CT KW - Mobile RFA PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (P12) SP - 1 EP - 8 CY - Berlin AN - OPUS4-24695 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials, part 1 X-ray refraction N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, with porosity and solid matter being intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using x-ray absorption and refraction, we quantitatively evaluate porosity and pore orientation in cordierite diesel particulate filter ceramics. Porosity values turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. KW - Porous ceramics KW - Pore orientation KW - X-ray refraction KW - Synchrotron KW - Interface PY - 2013 DO - https://doi.org/10.4416/JCST2013-00021 SN - 2190-9385 VL - 4 IS - 4 SP - 169 EP - 176 PB - Göller CY - Baden-Baden AN - OPUS4-29939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stuckert, J. A1 - Birchley, J. A1 - Große, M. A1 - Fernandez-Moguel, L. A1 - Onel, Yener A1 - Rössger, C. A1 - Steinbrück, M. T1 - The Quench-Debris test - Experimental results and modeling N2 - In the framework of the SARNET-2 WP5.1 the QUENCH-DEBRIS test was conducted as the 17th severe accident test using the QUENCH facility at KIT to investigate the formation and coolability of a prototypic debris bed. The test scenario was defined by pre-test calculations using the MELCOR code. This code was used also for post-test analysis. The test bundle with length of about 2 m contains the hafnium shroud tube and 12 heated peripheral rods with claddings made of hafnium. Hafnium was chosen because of its much higher melting temperature and the about one order of magnitude lower oxidation rate compared to zirconium. The claddings of the inner nine rods were made from Zry-4. They were filled with pre-fragmented zirconia pellets. The test started with an oxidation phase of 20 h at peek cladding temperature about 1800 K to reach complete oxidation of the Zry-4 claddings over a height of 500 mm. The temperatures expected from the pre-test simulation fitted well the experimentally observed evolution of the bundle conditions. The possibly surviving inner Zry-4 claddings were destroyed by the application of an axial mechanical force resulting in material relocation and formation of a heterogeneous debris bed consisting of segmented pellets and larger cladding tube fragments at the grid spacer 2 (350 mm elevation) and in a smaller amount at grid spacer 3 (1050 mm elevation). The so destroyed bundle was quenched with 10 g/s water. The evaporation rate generally showed an increasing trend during the reflood, except at the time of water penetration through the debris bed at spacer 2 when stagnation was observed. All peripheral hafnium claddings survived the whole test. During the oxidation phase about 100 g hydrogen was released. The time dependence of the hydrogen release predicted in the pre-test calculations fits well the measured one. The post-test examinations comprise videoscope inspections, high energy X-ray-tomography and metallographic investigations of the debris bed. T2 - ERMSAR-2013 - 6th European review meeeting on severe accident research CY - Avignon, France DA - 02.10.2013 KW - Hochenergie-Computertomographie KW - Nukleare Sicherheitsforschung PY - 2013 SP - 1 EP - 13 (Paper 2.6) AN - OPUS4-29467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Onel, Yener A1 - Lange, Axel A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Wolk, Thomas A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite Diesel particulate filter materials, Part 2 statistical analysis of computed tomography data N2 - Complementary to Part 1 of this work, the bi-continuous microstructure of porous synthetic cordierite ceramics for filtration applications was investigated using 3D x-ray computed tomography at different resolutions. Applying both Fast Fourier Transform and a newly developed image analysis algorithm, we quantitatively evaluated porosity and pore orientation. The statistical approach allows extraction of spatially resolved or average values. Porosity values based on x-ray absorption agree with mercury intrusion measurements, while pore orientation factors agree with x-ray refraction data (Part 1 of this work), and with published crystallographic texture data. KW - Pore orientation KW - Porous ceramics KW - Computed tomography KW - 3D microstructure PY - 2013 DO - https://doi.org/10.4416/JCST2013-00022 SN - 2190-9385 VL - 05 IS - 01 SP - 13 EP - 22 PB - Göller CY - Baden-Baden AN - OPUS4-30379 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Illerhaus, Bernhard A1 - Onel, Yener T1 - Mehr Strom oder mehr Spannung, ein Vergleich drei Röntgenröhren in der CT N2 - Sollten CT Aufnahmen quantitativ und automatisch ausgewertet werden, ist die Qualität der Tomogramme ein wesentlicher Punkt. Außerdem steht bei Serienmessungen nur eine begrenzte Meßzeit für jede Probe. Es werden die verschiedenen Mikrofokusröhren in Bezug auf die Parameter Orts- und Dichteauflösung, sowie Meßzeit verglichen, CT Beispiele dazu gezeigt. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Computertomographie KW - Ortsauflösung KW - Röhrenvergleich PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-307629 SN - 978-3-940283-61-0 IS - DGZfP-BB 148 SP - Di.1A.1, 1 EP - 9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-30762 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Bewertung von Porositätsparametern in Cordierit-Diesel-Partikelfilter-Materialien mit fortgeschrittenen Röntgenverfahren und statistischer Analyse N2 - Bikontinuierliche poröse Keramiken für Filteranwendungen weisen eine komplizierte Mikrostruktur auf, in der Poren und Festkörperphase 'vermischt' sind. Mechanische, thermische sowie Filtereigenschaften können nur präzise bestimmt werden, wenn die Morphologie beider Phasen quantitativ angegeben werden kann. Hier werden unter Anwendung von 3D Computertomographie (CT) und verschiedenen Techniken, die auf der Röntgenrefraktion basieren, die Porosität und die Porenorientierung in keramischen Cordierit-Dieselpartikelfiltern bewertet. Dabei werden zur Auswertung der Tomogramme die Fouriertransformierten sowie eine neu entwickelte richtungssensitive Bildanalyse (DIVA, directional interface variance analysis) angewandt. Sowohl die genannten Messtechniken als auch der statistische Ansatz gestatten die Extraktion optional ortsaufgelöster oder gemittelter Werte. Es ergeben sich sehr gute Übereinstimmungen der experimentell ermittelten Porositätswerte mit Ergebnissen aus Quecksilberintrusionsversuchen als auch der ermittelten Porenorientierung im Vergleich zu publizierten Angaben zur kristallographischen Textur. Dies legt den Schluss nahe, dass die Kenntnis der Grenzflächen (zwischen Poren und Materie) genügt, die morphologischen Eigenschaften solcher Materialien hinreichend zu beschreiben. T2 - DGZfP-Jahrestagung 2014 CY - Potsdam, Germany DA - 26.05.2014 KW - Cordierit KW - Poröse Keramik KW - Porenorientierung KW - Röntgenrefraktion KW - Computer-Tomographie KW - 3D-Mikrostruktur PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-312946 SN - 978-3-940283-61-0 VL - 148 SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-31294 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. A1 - Bruno, Giovanni T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods N2 - Bi-continuous porous ceramics for filtration applications possess a particularly complicated microstructure, whereby porosity and solid matter are intermingled. Mechanical, thermal, and filtration properties can only be precisely estimated if the morphology of both solid matter and porosity can be quantitatively determined. Using 3D computed tomography (CT) at different resolutions, and several X-ray refraction-based techniques, we quantitatively evaluated porosity and pore orientation in cordierite diesel particulate filter ceramics.Moreover, applying both Fast Fourier Transform (FFT) and a newly developed image analysis algorithm (directional interface variance analysis, DIVA), we quantitatively evaluated porosity and pore orientation. Both the experimental techniques and the statistical approach allow extraction of spatially resolved or average values.Porosity values from synchrotron computed tomography used turn out to agree with mercury intrusion measurements, while pore orientation factors agree with published crystallographic texture data. This latter point also implies that the study of the pore/matter interface is sufficient to describe the morphological properties of these materials. KW - Diesel particulate filters KW - DIVA Algorithm KW - Pore Orientation KW - Porous Ceramics KW - X-Ray Computed Tomography KW - X-Ray Refraction PY - 2014 DO - https://doi.org/10.4028/www.scientific.net/AST.91.64 SN - 1662-0356 VL - 91 SP - 64 EP - 69 PB - Techna CY - Faenza AN - OPUS4-32069 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -