TY - CONF A1 - Aidagulov, Gallyam A1 - Qiu, Xiangdong A1 - Brady, Dominic A1 - Abbad, Mustapha A1 - Onel, Yener A1 - Ewert, Uwe T1 - New insights into carbonate matrix stimulation from high-resolution 3D images of wormholes obtained in radial acidizing experiments N2 - We analyzed the results of high-energy X-ray CT scans for three 20×16×16 in. block samples of Indiana limestone from our recent radial acidizing experiments with HCl. CT scans were done for complete samples, and 3D images of internal dissolution patterns were built. Each 3D image consists of submillimeter-size voxels to capture fine details of individual wormholes. The obtained 3D images of acidized blocks allow us to observe from various angles the details of the wormholes obtained in the three experiments, which demonstrated wide pore-volume-to-breakthrough (PVBT) range with three different injection rates. Also, variation of the CT number reveals the presence of depositional layers in all block samples, and the obtained CT images were used to interpret the effect that rock layers might have on wormhole penetration at different injection rates. Further, the built voxel models were used to calculate the radial distributions of dissolved rock volume, which otherwise are not obvious for such complex branched structures as wormholes. We observed how varied experimental conditions affected those distributions. The radial distributions were found very similar across the samples, which suggested the way to detect the effective wormhole penetration depth. T2 - SPE Kingdom of Saudi Arabia Annual Technical Symposium and Exhibition CY - Dammam, Saudi Arabia DA - 23.04.2018 KW - Carbonate matrix stimulation KW - High-energy X-ray CT KW - XL-CT KW - Analysis of wormholes PY - 2018 DO - https://doi.org/10.2118/192366-MS SP - SPE-192366-MS, 1 EP - 19 AN - OPUS4-46654 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Onel, Yener T1 - 320kV Microfokusröntgenröhre und Flachdetektor, eine Kombination für die 3D-CT? T2 - DGZfP-Jahrestagung 2003: Zerstörungsfreie Materialprüfung - ZfP in Anwendung, Entwicklung und Forschung CY - Mainz, Germany DA - 2003-05-26 PY - 2003 AN - OPUS4-3805 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Onel, Yener T1 - Experiences in using a 320kV micro focus X-ray tube and a large sized amorphous silicon detector for 3D-CT T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 AN - OPUS4-3810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - 320 kV Mikrofokusröntgenröhre und Flächendetektor, eine Kombination für die 3D-CT? T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2003 CY - Mainz, Deutschland DA - 2003-05-26 PY - 2003 UR - http://www.ndt.net/article/dgzfp03/papers/v27/v27.htm SN - 3-931381-47-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 83-CD SP - 1 EP - 7(?) PB - DGZfP CY - Berlin AN - OPUS4-2874 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Onel, Yener A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Experiences in using a 320 kV micro focus X-ray tube and a large sized amorphous silicon detector for 3D-CT N2 - A novel 3D-CT scanner was set up at BAM to extend the applicability of the X-ray transmission microtomography (µ-CT) to specimens up to 30 cm in diameter. The scanner consists of a bipolar 320 kV micro focus tube and a flat panel detector of amorphous silicon. Minimisation of scattered radiation, control of room and system temperature, and corrective preprocessing on the projection data are necessary to achieve expectable CT images. Statistical evaluations to show the limits and results of CT investigations are reported. T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 UR - http://www.ndt.net/article/ct2003/v06/v06.htm SN - 3-931381-48-X N1 - Serientitel: DGZfP-Proceedings BB – Series title: DGZfP-Proceedings BB IS - 84-CD SP - 53 EP - 59 PB - DGZfP CY - Berlin AN - OPUS4-2875 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stuckert, J. A1 - Birchley, J. A1 - Große, M. A1 - Fernandez-Moguel, L. A1 - Onel, Yener A1 - Rössger, C. A1 - Steinbrück, M. T1 - The Quench-Debris test - Experimental results and modeling N2 - In the framework of the SARNET-2 WP5.1 the QUENCH-DEBRIS test was conducted as the 17th severe accident test using the QUENCH facility at KIT to investigate the formation and coolability of a prototypic debris bed. The test scenario was defined by pre-test calculations using the MELCOR code. This code was used also for post-test analysis. The test bundle with length of about 2 m contains the hafnium shroud tube and 12 heated peripheral rods with claddings made of hafnium. Hafnium was chosen because of its much higher melting temperature and the about one order of magnitude lower oxidation rate compared to zirconium. The claddings of the inner nine rods were made from Zry-4. They were filled with pre-fragmented zirconia pellets. The test started with an oxidation phase of 20 h at peek cladding temperature about 1800 K to reach complete oxidation of the Zry-4 claddings over a height of 500 mm. The temperatures expected from the pre-test simulation fitted well the experimentally observed evolution of the bundle conditions. The possibly surviving inner Zry-4 claddings were destroyed by the application of an axial mechanical force resulting in material relocation and formation of a heterogeneous debris bed consisting of segmented pellets and larger cladding tube fragments at the grid spacer 2 (350 mm elevation) and in a smaller amount at grid spacer 3 (1050 mm elevation). The so destroyed bundle was quenched with 10 g/s water. The evaporation rate generally showed an increasing trend during the reflood, except at the time of water penetration through the debris bed at spacer 2 when stagnation was observed. All peripheral hafnium claddings survived the whole test. During the oxidation phase about 100 g hydrogen was released. The time dependence of the hydrogen release predicted in the pre-test calculations fits well the measured one. The post-test examinations comprise videoscope inspections, high energy X-ray-tomography and metallographic investigations of the debris bed. T2 - ERMSAR-2013 - 6th European review meeeting on severe accident research CY - Avignon, France DA - 02.10.2013 KW - Hochenergie-Computertomographie KW - Nukleare Sicherheitsforschung PY - 2013 SP - 1 EP - 13 (Paper 2.6) AN - OPUS4-29467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Redmer, Bernhard A1 - Onel, Yener A1 - Ewert, Uwe T1 - Mechanised radiation techniques - an innovative technique of the mobile in-service inspection of circumferential welds T2 - 3rd International Conference "Pipeline Diagnostics" CY - Moscow, Russia DA - 2001-05-21 PY - 2001 SP - I34 AN - OPUS4-1176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Redmer, Bernhard A1 - Onel, Yener A1 - Ewert, Uwe A1 - Lunin, V. A1 - Podobedov, D. T1 - Mechanisierte Durchstrahlungsprüfung - Innovative Techniken zur Bewertung von Rundschweißnähten T2 - Tagung Schweißen und Schneiden ; Große Schweißtechnische Tagung CY - Essen, Deutschland DA - 2001-09-11 PY - 2001 SN - 3-87155-674-2 N1 - Serientitel: DVS-Berichte – Series title: DVS-Berichte IS - 216 SP - 243 EP - 247 PB - Verl. für Schweißen und Verwandte Verfahren, DVS-Verl. CY - Düsseldorf AN - OPUS4-1162 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Onel, Yener T1 - Application of X-ray Tomography for the Verifikation of Damage Mechanism in Concrete T2 - Proceedings of the "International Conference on Concrete Repair, Rehabilitation and Retrofitting" CY - Cape Town, South Africa DA - 2005-11-21 PY - 2005 AN - OPUS4-10650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Onel, Yener A1 - Dehn, F. ED - Alexander, M. T1 - Application of X-ray tomography for the verification of damage mechanisms in concrete T2 - International Conference on Concrete Repair, Rehabilitation and Retrofitting CY - Cape Town, South Africa DA - 2005-11-21 KW - Bauwerkssicherheit KW - Betonbau KW - Strukturaufklärung KW - Zerstörungsfreie Prüfung KW - Röntgen 3D-CT PY - 2005 SN - 0-415-39654-9 N1 - Serientitel: Balkema proceedings and monographs in engineering, water and earth sciences – Series title: Balkema proceedings and monographs in engineering, water and earth sciences SP - 170 EP - 171 PB - Taylor & Francis CY - London AN - OPUS4-11595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -