TY - CONF A1 - Bremser, Wolfram T1 - Homogeneity and stability testing of (C)RM N2 - The paper describes approaches to homogeneity and stability testing of (certified) reference materials which meet the requirements of ISO 17034. T2 - IDMS Training at BAM CY - BAM, Berlin, Germany DA - 22.02.2016 KW - Reference materials KW - Homogeneity KW - Stabilty PY - 2016 AN - OPUS4-36820 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Nehls, Irene A1 - Leschber, G. A1 - Frese, S. A1 - Walles, T. A1 - Neudecker, J. T1 - Comparison of volatile organic compounds from lung cancer patients and healthy controls—challenges and limitations of an observational study N2 - The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates. KW - Breath KW - Volatile organic compounds KW - Marker KW - Cancer KW - Gas chromatography KW - Solid phase microextraction KW - Volatilome PY - 2016 U6 - https://doi.org/10.1088/1752-7155/10/4/046007 SN - 1752-7155 SN - 1752-7163 VL - 10 IS - 4 SP - Article 046007, 1 EP - 17 PB - IOP Publishing AN - OPUS4-37801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Breitfeld, S. A1 - Sauer, Andreas A1 - Becker, Roland A1 - Kalbe, Ute A1 - Bremser, Wolfram A1 - Braun, Ulrike T1 - A Raman spectroscopic method for the monitoring of microplastics in soil N2 - Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - Raman spectroscopy KW - Microplastics KW - Soil KW - Chemometrics KW - PLS-DA PY - 2016 SP - P10, 59 EP - 60 AN - OPUS4-38392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paul, Andrea A1 - Bräuer, Bastian A1 - Nieuwenkamp, G. A1 - Ent, H. A1 - Bremser, Wolfram T1 - A validated near-infrared spectroscopic method for methanol detection in biodiesel N2 - Abstract. Biodiesel quality control is a relevant issue as biodiesel properties influence diesel engine performance and integrity. Within the European Metrology Research Program (EMRP) ENG09 project “Metrology for Biofuels”, an on-line /at-site suitable near-infrared spectroscopy (NIRS) method has been developed in parallel with an improved EN14110 headspace GC analysis method for methanol in biodiesel. Both methods have been optimized for a methanol content of 0.2 mass% as this represents the maximum limit of methanol content in FAME according to EN 14214:2009. The NIRS method is based on a mobile NIR spectrometer equipped with a fiber-optic coupled probe. Due to the high volatility of methanol, a tailored air-tight adaptor was constructed to prevent methanol evaporation during measurement. The methanol content of biodiesel was determined from evaluation of NIRS spectra by Partial Least Squares Regression (PLS). Both GC analysis and NIRS exhibited a significant dependence on biodiesel feedstock. The NIRS method is applicable to a content range of 0.1 % (m/m) to 0.4 % (m/m) of methanol with uncertainties at around 6% relative for the different feedstocks. A direct comparison of headspace GC and NIRS for samples of FAMEs yielded that the results of both methods are fully compatible within their stated uncertainties. KW - FAME KW - Headspace GC KW - NIR KW - PLSR KW - EMRP PY - 2016 U6 - https://doi.org/10.1088/0957-0233/27/6/065002 SN - 0957-0233 SN - 1361-6501 VL - 27 IS - 6 SP - 065002, 1 EP - 9 PB - IOP Publishing Ltd CY - UK AN - OPUS4-37471 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - Homogeneity and stability testing of (C)RM N2 - An overview is given on the activities of ISO/REMCO reagrding homogeneity and stability testing of (C)RM, including detailed requirements to RMP. T2 - 1st and 2nd IDMS Training at BAM CY - BAM Berlin, Germany DA - 23.02.2016 und 13.05.2016 KW - Homogeneity KW - Reference materials KW - Stabilty PY - 2016 AN - OPUS4-38883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -