TY - CONF A1 - Bremser, Wolfram T1 - COMAR the international database for certified reference materials T2 - 1. International Scientific Conference "Reference materials in measurement and technology" CY - Yekaterinburg, Russia DA - 2013-09-10 PY - 2013 AN - OPUS4-29270 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hässelbarth, Werner A1 - Bremser, Wolfram T1 - Correlation in chemical measurement T2 - 10th Congrès International de Métrologie ; 10th International Metrology Congress CY - Saint-Louis, France DA - 2001-10-22 PY - 2001 SN - 2-914324-00-6 SP - 1 EP - 5(?) PB - Collège Métrologie CY - Bagneux AN - OPUS4-1056 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schultze, Karin A1 - Nehls, Irene A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Win, Tin T1 - Zertifiziertes Referenzmaterial "BAM-U007" - Organochlorpestizide in Boden T2 - ANAKON 2001 CY - Konstanz, Germany DA - 2001-04-04 PY - 2001 SP - 1(?) AN - OPUS4-1314 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Merchel, Silke A1 - Bremser, Wolfram ED - Nakamura, T. T1 - First international 26Al interlaboratory comparison - Part I T2 - 9th International Conference on Accelerator Mass Spectrometry ; 9th AMS Conference CY - Nagoya, Japan DA - 2002-09-09 PY - 2004 SN - 0168-583X N1 - Serientitel: Nuclear instruments & methods in physics research : Section B, Beam interactions with materials and atoms – Series title: Nuclear instruments & methods in physics research : Section B, Beam interactions with materials and atoms IS - 223-224 SP - 131 PB - North-Holland CY - Amsterdam AN - OPUS4-1604 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - Drift control and merging schemes in stability testing T2 - EUROANALYSIS XIV CY - Antwerp, Belgium DA - 2007-09-09 PY - 2007 AN - OPUS4-16262 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - Self- consistent reference value estimation T2 - EUROANALYSIS XIV CY - Antwerp, Belgium DA - 2007-09-09 PY - 2007 AN - OPUS4-16255 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Kipphardt, Heinrich A1 - Lehnik-Habrink, Petra A1 - Panne, Ulrich A1 - Töpfer, Antje T1 - Stability testing in an integrated scheme N2 - ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment. KW - Certified reference materials KW - Stability KW - Shelf life KW - Arrhenius model KW - ERM PY - 2006 DO - https://doi.org/10.1007/s00769-006-0152-6 SN - 0949-1775 SN - 1432-0517 VL - 11 IS - 10 SP - 489 EP - 495 PB - Springer CY - Berlin AN - OPUS4-14063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - Reference materials stability issues revisited T2 - International Conferece on Biological and Environmental Reference Materials - BERM10 CY - Charleston, SC, USA DA - 2006-04-30 PY - 2006 AN - OPUS4-14029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - The LIBS 2008 Contest: A first insight into the data T2 - LIBS 2008 CY - Berlin, Germany DA - 2008-09-22 PY - 2008 AN - OPUS4-18510 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Kipphardt, Heinrich A1 - Richter, Silke A1 - Bremser, Wolfram A1 - Arvizu Torres, M. A1 - Lara Manzano, J. A1 - Buzoianu, M. A1 - Hill, S. A1 - Petrov, P. A1 - Goenaga-Infante, H. A1 - Sargent, M. A1 - Fisicaro, P. A1 - Labarraque, G. A1 - Zhou, T. A1 - Turk, G. C. A1 - Winchester, M. A1 - Miura, T. A1 - Methven, B. A1 - Sturgeon, R. A1 - Jährling, R. A1 - Rienitz, O. A1 - Mariassy, M. A1 - Hankova, Z. A1 - Sobina, E. A1 - Krylov, A. I. A1 - Kustikov, Y. A. A1 - Smirnov, V. V. T1 - Establishing comparability and compatibility in the purity assessment of high purity zinc as demonstrated by the CCQM-P149 intercomparison N2 - For the first time, an international comparison was conducted on the determination of the purity of a high purity element. Participants were free to choose any analytical approach appropriate for their institute’s applications and services. The material tested was a high purity zinc, which had earlier been assessed for homogeneity and previously used in CCQM-K72 for the determination of six defined metallic impurities. Either a direct metal assay of the Zn mass fraction was undertaken by EDTA titrimetry, or an indirect approach was used wherein all impurities, or at least the major ones, were determined and their sum subtracted from ideal purity of 100 %, or 1 kg/kg. Impurity assessment techniques included glow discharge mass spectrometry, inductively coupled plasma mass spectrometry and carrier gas hot extraction/combustion analysis. Up to 91 elemental impurities covering metals, non-metals and semi-metals/metalloids were quantified. Due to the lack of internal experience or experimental capabilities, some participants contracted external laboratories for specific analytical tasks, mainly for the analysis of non-metals. The reported purity, expressed as zinc mass fraction in the high purity zinc material, showed excellent agreement for all participants, with a relative standard deviation of 0.011 %. The calculated reference value, w(Zn) = 0.999 873 kg/kg, was assigned an asymmetric combined uncertainty of + 0.000025 kg/kg and – 0.000028 kg/kg. Comparability amongst participating metrology institutes is thus demonstrated for the purity determination of high purity metals which have no particular difficulties with their decomposition / dissolution process when solution-based analytical methods are used, or which do not have specific difficulties when direct analysis approaches are used. Nevertheless, further development is required in terms of uncertainty assessment, quantification of non-metals and the determination of purity of less pure elements and/or for those elements suffering difficulties with the decomposition process. KW - Purity assessment KW - Direct metal assay KW - Impurity assessment KW - Non-metal analysis KW - High-purity elements KW - SI-traceability PY - 2018 DO - https://doi.org/10.1088/1681-7575/aaa677 SN - 1681-7575 SN - 0026-1394 VL - 55 IS - 2 SP - 211 EP - 221 PB - Institute of Physics Publishing CY - Bristol AN - OPUS4-44257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Breitfeld, S. A1 - Sauer, Andreas A1 - Becker, Roland A1 - Kalbe, Ute A1 - Bremser, Wolfram A1 - Braun, Ulrike T1 - A Raman spectroscopic method for the monitoring of microplastics in soil N2 - Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - Raman spectroscopy KW - Microplastics KW - Soil KW - Chemometrics KW - PLS-DA PY - 2016 SP - P10, 59 EP - 60 AN - OPUS4-38392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Panne, Ulrich A1 - Bremser, Wolfram T1 - Considerations with regard to the calculation of key comparison reference values and uncertainties N2 - Much has been published over the last years on finding the best (consensus) reference value for a given set of key comparison data, and a suite of approaches proposed. In this paper, several aspects are highlighted which should be taken into account when deciding on key comparison strategies, protocols, and the best approach to reliable key comparison reference value and uncertainty. Some of these aspects are briefly discussed. The paper is intended to intensify discussions, and any comments and opinions are welcome. KW - Key comparison KW - Reference value KW - Reference value uncertainty KW - Equivalence PY - 2009 DO - https://doi.org/10.1007/s00769-009-0515-x SN - 0949-1775 SN - 1432-0517 VL - 14 IS - 5 SP - 281 EP - 287 PB - Springer CY - Berlin AN - OPUS4-19460 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Bremser, Wolfram A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria A1 - Till, Carola T1 - Untersuchungen zur Verbesserung der Messung von flüchtigen organischen Verbindungen aus Fußbodenbelägen im Rahmen der gesundheitlichen Bewertung von Bauprodukten T1 - Investigations for the improvement of the measurement of volatile organic compounds from floor coverings within the health-related evaluation of construction products N2 - In den Grundsätzen des DIBt zur gesundheitlichen Bewertung von Bauprodukten in Innenräumen ist das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (AgBB-Schema) als wesentliche Grundlage enthalten. Dieses Schema bewertet die mit Hilfe einer Prüfkammermessung bestimmten Emissionen von flüchtigen und schwer flüchtigen organischen Verbindungen (VOC und SVOC). Die Prüfkammer dient dabei der Einhaltung standardisierter Klimabedingungen (Temperatur 23°C, relative Luftfeuchtigkeit 50 %) sowie der Einstellung bestimmter Prüfparameter wie Luftwechselrate und Beladungsfaktor. Die Anforderungen an eine Prüfkammer sind in DIN EN ISO 16000-9 beschrieben. Die Analytik und Quantifizierung der VOC geschieht mittels Tenax-Thermodesorption und nachfolgender Gaschromatographie gekoppelt mit Massenspektrometrie und ist in DIN ISO 16000-6 beschrieben. Probenahmen werden am 3. und 28. Tag der Prüfkammermessung durchgeführt. Am dritten Tag erfolgt eine Bewertung der Emissionen aus dem Bauprodukt anhand des TVOC-Wertes und der Summe der detektierten cancerogenen Stoffe (nach 67/548/EWG, Einstufung als cancerogen der Kategorie 1 und 2). Ein Produkt erfüllt die Kriterien, wenn der TVOC-Wert nach 3 Tagen nicht größer als 10 mg/m³ ist und die Summe der Cancerogene 10 μg/m³ nicht übersteigt. Am 28. Tag wird zusätzlich zum TVOC-Wert und den Cancerogenen die Emission von SVOCs berücksichtigt und eine Einzelstoffbewertung anhand von NIK-Werten vorgenommen. Der TVOC-Wert nach 28 Tagen darf nicht größer als 1 mg/m³ sein, die Summe der Cancerogenen nicht größer als 1 μg/m³. Die Summe an SVOCs darf eine Konzentration von 0,1 mg/m³ nicht überschreiten. Der sogenannte R-Wert, die Summe aller Quotienten aus Einzelstoffkonzentration und dem NIK-Wert des Einzelstoffes, darf einen Wert von 1 nicht übersteigen. Außerdem darf die Summe von Substanzen, die keinen NIK-Wert besitzen, nicht größer als 0,1 mg/m³ sein. Der Ringversuch, der im Rahmen der Untersuchungen zur Verbesserung der Prüfkammermessungen durchgeführt wurde, hatte vor allem den Zweck, den Einfluss unterschiedlicher Methodenparameter bei der Prüfkammermessung in unterschiedlichen Prüflaboratorien zu erfassen. Anhand der Ergebnisse sollte eine Ursachenforschung für die großen Abweichungen der bisher durchgeführten Ringversuche erfolgen. Durch die drei aufeinander aufbauenden Schritte sollte der Einfluss der Analytik, der Probenahme und der Prüfkammer geklärt werden. Der Ringversuch diente nicht der Anerkennung der teilnehmenden Prüflaboratorien im Bereich der Bauproduktenprüfung für eine DIBt-Zulassung. Ausgehend von den Prüflaboratorien, die in der Projektgruppe „Prüf- und Messverfahren zur gesundheitlichen Bewertung von Bauprodukten“ des DIBt mitarbeiteten, wurde der Kreis auf europäische Prüflaboratorien erweitert, die sich ebenfalls mit Prüfkammermessungen an Bauprodukten beschäftigen. Dazu erging ein Einladungsschreiben an alle von vorangegangenen Ringversuchen bekannten Teilnehmer. Insgesamt ergab sich ein Teilnehmerkreis von 29 Instituten, davon 16 aus Deutschland, jeweils zwei aus Österreich, Belgien, Schweden, Dänemark und jeweils eins aus Finnland, Großbritannien, Frankreich, Italien und Portugal. Vor Beginn des Ringversuches waren davon 11 im Zulassungsbereich tätig. Zur wissenschaftlichen Begleitung wurde durch das DIBt ein Betreuergremium einberufen. In zwei Sitzungen (April und November 2007) wurden die aktuellen Ergebnisse vorgestellt und diskutiert sowie die weitere Vorgehensweise besprochen. Eine Abschlussveranstaltung nach der Auswertung des dritten Schrittes des Ringversuches fand im April 2008 im DIBt statt. Dazu waren alle Teilnehmer eingeladen. Für die Emissionsmessung von flüchtigen organischen Verbindungen (VOC) aus Materialien mit Hilfe von Emissionsprüfkammern sind bisher nur wenige Ringversuche durchgeführt worden (De Bortoli et al. 1999; Jann et al. 2000; Hansen et al. 2000; Oppl and Winkels 2002; Windhövel and Oppl 2005; Kirchner 2007; Oppl 2008). Dabei zeigten sich meist große Streuungen der Ergebnisse. Ein großes Problem für die Durchführung solcher Ringversuche ist das Fehlen von Referenzmaterialien mit bekannter Emissionsrate von Zielsubstanzen. Deshalb orientiert man sich für die Auswertung solcher Ringversuche am Mittelwert aller Ergebnisse. Dafür ist die Homogenität des Testmaterials von größter Bedeutung. Diese wurde in früheren Ringversuchen nicht wirklich sichergestellt. Im hier beschriebenen Forschungsprojekt wurde auf die Homogenität des Probenmaterials besonderen Wert gelegt. Der gesamte Ringversuch wurde in drei Schritte unterteilt. Die einzelnen Schritte wurden dabei von Schritt zu Schritt immer komplexer. Im ersten Schritt erfolgte die Analyse von flüssigen Lösungen, im zweiten die Bestimmung von VOCs in Prüfkammerluft und im dritten Schritt erfolgte eine komplette Emissionsprüfkammermessung bei den Teilnehmern. N2 - In the German Institute for Construction Technology’s (DIBt) principles for the health assessment for construction products used in interiors, the Evaluation procedure of the Committee for Health-related Evaluation of Building Products (AgBB Scheme) is contained as a substantial base. This scheme evaluates the emissions of volatile and semivolatile organic compounds (VOC and SVOC), determined by test chamber measurements. Within the interlaboratory comparison, which was divided into three steps, the emission test method from building products was checked against the principles of health-related evaluation of construction products in indoor spaces (based on DIN EN ISO 16000-9 together with DIN ISO 16000-6) with the co-operation of 29 European test institutes. The objective was to assess the comparability of the test method carried out in different test Chambers and using different thermodesorption devices. In the first step the analysis of liquid solutions took place to observe the influence of the analysis itself. In the second step VOCs were sampled in the air of a BAM test chamber onto tubes from the participants for the Analysis by them. In the third step a complete Emission test chamber measurement was carried out by the participants. A major problem for the execution of such interlaboratory comparisons is the lack of reference materials. Therefore the homogeneity of the test material was of great importance. As a result of the first step (analysis of 4 liquid solutions) a standard deviation of less than 20 % for 8 out of 11 substances tested was obtained. The Standard deviations for dichloropropanol, caprolactam and Butyl diglycol ranged up to 36 %. The second step, which included air sampling at a BAM test chamber, resulted in only one standard deviation value less than 20 % (11 % for styrene). The standard deviations for the other six substances were between 20 % and 36 %. For step 3 a sealant was chosen instead of the flooring material for homogeneity reasons. In step 3 the standard deviations for 4 of the 7 measured VOC concentrations from two chamber tests were between 17 % and 19 % and thus within the same range as in Step 1 and even better than for most substances in Step 2. A Standard deviation of 60 % was found for the key component ethanediol, but this can be explained with the difficult analysis method for this substance. A second objective of the project was to formulate criteria against which the specialist competence of the test institutes for emission tests can be checked and based on the principles for the health assessment for construction products used in interior. For this purpose a catalogue of criteria has been developed, which is divided into three parts. In the first part, basic requirements are formulated such as impartiality, accreditation for test chamber measurements, verification of experience by participation in earlier interlaboratory comparisons and the laboratory equipment. The second part requires the test-specific proof in the form of successful participation in interlaboratory comparisons organised by BAM biannually. The third part instructs the laboratories that they must ensure they are always upto-date both in terms of their knowledge and the available equipment. The quality assurance for the knowledge is ensured by regular participation in the exchanging of experience between the test laboratories. In terms of technical requirements the test institutes must be willing to successfully participate in at least one interlaboratory comparison per year. The present interlaboratory comparison was not designed to recognise the participating test laboratories in the field of the construction product testing for a DIBt approval. KW - Ringversuch KW - Laborvergleich KW - VOC-Emissionen KW - Kammermessungen KW - Round robin KW - Inter laboratory study KW - VOC emissions KW - Emission test chamber PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-198380 UR - https://www.baufachinformation.de/buch/Untersuchungen-zur-Verbesserung-der-Messung-von-fl%C3%BCchtigen-organischen-Verbindungen-aus-Fu%C3%9Fbodenbel%C3%A4gen-im-Rahmen-der-gesundheitlichen-Bewertung-von-Bauprodukten/230803 SN - 978-3-8167-8100-4 N1 - Sprachen: Deutsch/Englisch - Languages: German/English IS - T 3217 SP - 1 EP - 206 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-19838 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, Katrin A1 - Spieles, Monika A1 - Bremser, Wolfram A1 - Resch-Genger, Ute T1 - Narrow-band emitting solid fluorescence reference standard with certified intensity pattern N2 - The development of a lanthanum-phosphate glass doped with several rare-earth-ions for use as solid fluorescence standard is described. The cuvette-shaped reference material which shows a characteristic emission intensity pattern upon excitation at 365 nm consisting of a multitude of relatively narrow emission bands in the wavelength region between 450 nm and 700 nm is intended for the day-to-day performance validation of fluorescence measuring devices. Evaluation of the fluorescent glass include the determination of all properties which can affect its relative emission intensity profile or contribute to the uncertainty of the certified values like absorption spectra, fluorescence anisotropy, excitation wavelength and temperature dependence of the spectroscopic features, homogeneity of fluorophore distribution, photo- and long-term stability. Moreover, a certification procedure was developed including the normalization of the intensity profile consisting of several narrow emission bands and the calculation of wavelength-dependent uncertainties. Criteria for the design, characterization, and working principle of the new reference material BAM-F012 are presented, and possible applications of this ready-to-use fluorescence standard are discussed. PY - 2015 DO - https://doi.org/10.1021/acs.analchem.5b02209 SN - 0003-2700 SN - 1520-6882 VL - 87 SP - 7204 EP - 7210 PB - American Chemical Society CY - Washington, DC AN - OPUS4-33615 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koch, Matthias A1 - Bremser, Wolfram A1 - Köppen, Robert A1 - Krüger, Rita A1 - Rasenko, Tatjana A1 - Siegel, David A1 - Nehls, Irene T1 - Certification of reference materials for ochratoxin A analysis in coffee and wine N2 - Mycotoxins are important non-anthropogenic food and feed contaminants, which can be present on almost every agricultural commodity. Effective consumer protection therefore essentially depends on food surveillance by reliable quantitative analysis enabled by appropriate quality control. Certified (matrix) reference materials (CRMs) are versatile tools to support Quality assurance. However, in the case of ochratoxin A (OTA), a hepato- and nephrotoxic mycotoxin, which is regulated in various foods, there is a lack of suitable CRMs. This lack has now been overcome by the development of two European Reference Materials (ERM®) for the Determination of OTA in roasted coffee (ERM®-BD475) and red wine (ERM®-BD476). This article discusses the material preparation process as well as the results of homogeneity and stability testing. Furthermore, the results of the inhouse certification studies carried out at BAM Federal Institute for Materials Research and Testing are presented and discussed. Interlaboratory comparison studies involving selected expert laboratories with documented Expertise in the field of mycotoxin analysis were conducted to confirm the certified values determined by BAM. The certified ochratoxin A values and their corresponding expanded uncertainties (k = 2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows: (6.0 ± 0.6) µg kg-1 for roasted coffee, ERM®-BD475, and (0.52 ± 0.11) µg L-1 for red wine, ERM®-BD476. KW - OTA KW - Coffee KW - Wine KW - Food safety and quality KW - European reference materials KW - CRM PY - 2011 DO - https://doi.org/10.1007/s00769-011-0783-0 SN - 0949-1775 SN - 1432-0517 VL - 16 SP - 429 EP - 437 PB - Springer CY - Berlin AN - OPUS4-24235 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Resch-Genger, Ute A1 - Bremser, Wolfram A1 - Pfeifer, Dietmar A1 - Spieles, Monika A1 - Hoffmann, Angelika A1 - DeRose, P.C. A1 - Zwinkels, J. C. A1 - Gauthier, F. A1 - Ebert, B. A1 - Taubert, R.D. A1 - Voigt, J. A1 - Hollandt, J. A1 - Macdonald, R. T1 - State-of-the art comparability of corrected emission spectra. 2. Field laboratory assessment of calibration performance using spectral fluorescence standards N2 - In the second part of this two-part series on the state-of-the-art comparability of corrected emission spectra, we have extended this assessment to the broader community of fluorescence spectroscopists by involving 12 field laboratories that were randomly selected on the basis of their fluorescence measuring equipment. These laboratories performed a reference material (RM)-based fluorometer calibration with commercially available spectral fluorescence standards following a standard operating procedure that involved routine measurement conditions and the data evaluation software LINKCORR developed and provided by the Federal Institute for Materials Research and Testing (BAM). This instrument-specific emission correction curve was subsequently used for the determination of the corrected emission spectra of three test dyes, X, QS, and Y, revealing an average accuracy of 6.8% for the corrected emission spectra. This compares well with the relative standard uncertainties of 4.2% for physical standard-based spectral corrections demonstrated in the first part of this study (previous paper in this issue) involving an international group of four expert laboratories. The excellent comparability of the measurements of the field laboratories also demonstrates the effectiveness of RM-based correction procedures. KW - Fluorescence KW - Photoluminescence KW - Dye KW - Uncertainty KW - Method comparison KW - Standard KW - Spectral correction KW - Spectral fluorescence standard PY - 2012 DO - https://doi.org/10.1021/ac203451g SN - 0003-2700 SN - 1520-6882 VL - 84 IS - 9 SP - 3899 EP - 3907 PB - American Chemical Society CY - Washington, DC AN - OPUS4-27081 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koch, Matthias A1 - Bremser, Wolfram A1 - Köppen, Robert A1 - Siegel, David A1 - Töpfer, Antje A1 - Nehls, Irene T1 - Development of two certified reference materials for acrylamide determination in foods N2 - Certified reference materials (CRMs) are a versatile tool for quality assurance in the chemical laboratory. In the case of acrylamide analysis, the availability of appropriate materials was rather limited. This lack of acrylamide matrix CRMs has now been overcome by the development of two European reference materials (ERM) for the determination of acrylamide in food (crispbread, ERM-BD272, and rusk, ERM-BD274). This article describes the preparation of the materials, provides the results of the homogeneity and stability studies, and presents and discusses the outcome of the certification studies. Expert laboratories from different European countries took part in the certification studies using various analytical methods. The acrylamide mass fractions were certified to 980 µg kg-1 for crispbread and 74 µg kg-1 for rusk. KW - Certified reference materials KW - ERM KW - Acrylamide KW - Crispbread KW - Rusk KW - Quality assurance KW - Homogeneity KW - Stability PY - 2009 DO - https://doi.org/10.1021/jf901329t SN - 0021-8561 SN - 1520-5118 VL - 57 IS - 18 SP - 8202 EP - 8207 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-19888 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Siegel, David A1 - Merkel, Stefan A1 - Bremser, Wolfram A1 - Koch, Matthias A1 - Nehls, Irene T1 - Degradation kinetics of the Alternaria mycotoxin tenuazonic acid in aqueous solutions N2 - The degradation kinetics of the Alternaria mycotoxin tenuazonic acid (l-TA) in aqueous buffer were studied over a period of 4 months at different pH levels (3.5 and 7.0) and temperatures (4, 25 and 40°C). l-TA and its degradation products were quantified by newly developed high-performance liquid chromatography methods with UV or electrospray multistage mass spectrometry detection. At pH 3.5, significant degradation occurred at 25 and 40°C, the respective l-TA half-lives being 73.8±0.4 and 14.0±0.1 days. Two degradation processes, epimerization and hydrolysis, were evaluated kinetically. The hydrolytically formed iso-deacetyl TA (iso-DTA, epimeric mixture) was found to be the stable end product of l-TA degradation under the conditions of this study. This indicates that iso-DTA as well as the l-TA epimer u-TA are formed in aqueous beverage matrices. KW - Tenuazonic acid KW - Alternaria KW - Epimerization KW - Degradation KW - Kinetics PY - 2010 DO - https://doi.org/10.1007/s00216-009-3288-5 SN - 1618-2642 SN - 1618-2650 VL - 397 IS - 2 SP - 453 EP - 462 PB - Springer CY - Berlin AN - OPUS4-21373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bremser, Wolfram T1 - Purity CRM and the physical constraint T2 - 10th International Conference on Biological and Environmental Reference Materials (BERM 10) CY - Charleston, SC, USA DA - 2006-04-30 PY - 2006 AN - OPUS4-12587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Bremser, Wolfram A1 - Rasenko, Tatjana A1 - Koch, Matthias T1 - Development and certification of a reference material for Fusarium mycotoxins in wheat flour N2 - Deoxynivalenol (DON), nivalenol (NIV) and zearalenone (ZEN) are toxic secondary metabolites produced by several species of Fusarium fungi. These mycotoxins are often found together in a large variety of cereal-based foods, which are regulated by maximum content levels of DON and ZEN. To date, suitable certified reference materials (CRM) intended for quality control purposes are lacking for these Fusarium mycotoxins. In order to overcome this lack, the first CRM for the determination of DON, NIV and ZEN in naturally contaminated wheat flour (ERM®-BC600) was developed in the framework of a European Reference Materials (ERM®) project. This article describes and discusses the whole process of ERM®-BC600 development, including material preparation, homogeneity and stability studies, and an interlaboratory comparison study for certification. A total of 21 selected expert laboratories from different European countries with documented expertise in the field of mycotoxin analysis took part in the certification study using various gas and liquid chromatographic methods. The certified values and their corresponding expanded uncertainties (k=2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows: 102±11 µgkg-1 for DON, 1000±130 µgkg-1 for NIV and 90±8 µgkg-1 for ZEN. KW - Deoxynivalenol KW - Nivalenol KW - Zearalenone KW - Food KW - ERM KW - Quality assurance PY - 2013 DO - https://doi.org/10.1007/s00216-013-6857-6 SN - 1618-2642 SN - 1618-2650 VL - 405 IS - 14 SP - 4755 EP - 4763 PB - Springer CY - Berlin AN - OPUS4-28303 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -