TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Marinenko, R.B. A1 - Rackwitz, Vanessa A1 - Bremser, Wolfram A1 - Unger, Wolfgang T1 - Determination of the k-values of copper-gold alloys with ED- and WD-EPMA - Results of an inter-laboratory comparison N2 - An inter-laboratory comparison organized as a pilot study (PS) has been performed under the umbrella of the Consultative Committee for Amount of Substance – Metrology in Chemistry (CCQM) / Surface Analysis Working Group (SAWG) with the objective to compare k-values measured with Electron Probe X-ray Microanalysis (EPMA) for copper-gold alloys. The k-value, defined as the ratio of the Xray photon intensity of an X-ray characteristic line of the unknown sample to the corresponding one in the reference material, is a rough estimate of the mass fraction of the respective element. Basically, the mass fractions can be calculated from the k-values after applying a matrix correction procedure, which includes empirical approaches, so that traceability gets lost. Due to its physical, measurable nature, the k-value has been selected in the present PS as the primary measurand. The mass fraction has been set as the secondary (derived) measurand. Both EDX and WDX have been employed. The WDX results and the overall comparability between the k-values obtained by EDX and WDX are still in progress. KW - Interlaboratory comparison KW - EDX KW - WDX KW - EPMA KW - K-values KW - Cu-Au alloy KW - CCQM PY - 2014 DO - https://doi.org/10.1017/S1431927614005376 SN - 1431-9276 SN - 1435-8115 VL - 20 IS - Suppl. S 3 SP - 730 EP - 731 PB - Cambridge University Press CY - New York, NY AN - OPUS4-31338 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gross, Thomas A1 - Pippig, F. A1 - Merz, B. A1 - Merz, R. A1 - Vohrer, U. A1 - Mix, Renate A1 - Steffen, H. A1 - Bremser, Wolfram A1 - Unger, Wolfgang T1 - Determination of OH groups at plasma oxidised poly(propylene) by TFAA chemical derivatisation XPS: an inter-laboratory comparison N2 - A first inter-laboratory comparison was conducted to demonstrate and document the capability of interested laboratories to measure the fraction of C—OH species on a plasma oxidised poly(propylene) sample by using a chemical derivatisation XPS approach. This report presents the results from that inter-laboratory comparison and includes the data received for the measured values and their associated standard deviations of laboratory means, at a 95% confidence level. The measurements were guided by a protocol developed within the group before and summarised shortly in the paper. Standard deviations that may characterise the state-of-the-art for the nominally simple and rather often practised case of TFAA chemical derivatisation XPS of C—OH species on a plasma oxidised polyolefin surface are calculated following ISO 5725-2:1994. The main conclusion is that the associated degree of equivalence reached by the participating laboratories in this comparison is still low. Further research to improve chemical derivatisation XPS protocols is mandatory. KW - Chemical derivatisation KW - ESCA/XPS KW - Inter-laboratory comparison KW - Photoelectron spectroscopy (PES) KW - Poly(propylene) (PP) PY - 2010 DO - https://doi.org/10.1002/ppap.200900142 SN - 1612-8850 SN - 1612-8869 VL - 7 IS - 6 SP - 494 EP - 503 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-21678 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -