TY - CONF A1 - Müller, B. A1 - Panaskova, J. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Plehn, W. T1 - Results of sensory tests and sensory-limit settings for building materials in Germany N2 - Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources. Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Perceived air-quality KW - Odour evaluation KW - Odour labelling KW - Test procedure KW - Standardisation PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Howard-Reed, C. A1 - Liu, Z. A1 - Cox, S. A1 - Little, J. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Persily, A. T1 - Inter-laboratory study approach to validate the performance of a prototype reference material for product emissions testing N2 - Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Test method validation KW - Volatile organic compounds KW - Product certification PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Oppl, R. T1 - European Test Method Validation Approaches T2 - NIST/Virginia Tech Workshop: Reference Material Development for Product Emissions Testing CY - Gaithersburg, MD, USA DA - 2011-04-28 PY - 2011 AN - OPUS4-23913 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Ringversuche zur Überprüfung von Emissionskammermessungen T2 - 16. WaBoLu Innenraumtage CY - Berlin, Germany DA - 2009-05-18 PY - 2009 AN - OPUS4-19510 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria T1 - Emissionen flüchtiger organischer Verbindungen aus Bauprodukten T2 - VDI Wissensforum "Schadstoffe in Bauprodukten" CY - Stuttgart, Deutschland DA - 2009-10-21 KW - Emissionen KW - Bauprodukte KW - Emissionsmesskammern KW - VOC KW - SVOC KW - Geruch KW - AgBB PY - 2009 SP - 1 EP - 22 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-20306 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Method-verification and optimisation of the standardised assessment of odour intensity regarding ISO 16000-28 N2 - Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons. In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Odour assessment KW - Perceived odour intensity KW - Reference odour KW - Emission testing KW - Building products PY - 2016 SN - 978-0-9846855-5-4 SP - Paper 568, 1 EP - 6 AN - OPUS4-38373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Geruchsprüfungen nach DIN-ISO 16000-28-Grundlagen und Erprobung für den Blauen Engel T2 - 22. WaBoLu-Innenraumtage - Drucker, Gerüche und mehr ... CY - Berlin, Germany DA - 2015-05-12 PY - 2015 AN - OPUS4-33280 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, B. A1 - Panasková, J. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Scutaru, A.M. A1 - Plehn, W. T1 - Entwicklungen der Bewertungsmethodik von Gerüchen in Innenräumen N2 - Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen. KW - Geruch KW - Innenraum KW - Bauprodukte KW - Bewertung PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 70 EP - 82 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-32403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Aktuelle Ringversuche der BAM zu VOC und Gerüchen N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt. T2 - 26. WaBoLu-Innenraumtage CY - Berlin, Germany DA - 20.05.2019 KW - Geruch KW - Ringversuch KW - Bauprodukte KW - Emission KW - Emissionskammer PY - 2019 AN - OPUS4-49237 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 AN - OPUS4-49327 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - The BEMMA-Scheme helpful for low VOC inside display cases? N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. T2 - Indoor Air Quality in Heritage and Historic Environments CY - Online meeting DA - 12.10.2020 KW - Museum KW - VOC-emission KW - BEMMA KW - Display case PY - 2020 AN - OPUS4-51470 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Messverfahren BEMMA-Schema: Entstehung, Anwendung, Grenzen N2 - Mit dem BEMMA-Verfahren lassen sich flüchtige organische Verbindungen aus modernen Werkstoffen, die in mittel- oder unmittelbarem Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen, untersuchen und bewerten. Das Verfahren wurde im Rahmen eines AIF-Vorhabens und der Untersuchung von über 100 unterschiedlichen Materialien entwickelt. Weiterhin wurden mit den gewonnenen Ergebnissen und einigen zuvor bereits identifizierten Problemstoffen wie Essigsäure, Formaldehyd oder Oxime aus den Vorhabenerkenntnissen Bewertungskriterien erarbeitet. Die Vitrinenbaumaterialien, nicht die Vitrine, werden im Hinblick auf ihre Emissionen bewertet, wobei z. B. Holzwerkstoffe nicht bewertet werden, zumal diese meist mit Formaldehyd ein Emissionsproblem hätten. Der Einsatz von Materialien für Vitrinen, die gemäß BEMMA-Schema getestet wurden und die die Emissionswerte erfüllen, soll die Herstellung möglichst emissionsarmer Vitrinen ermöglichen. Kernstück des BEMMA-Schemas ist die Bewertung aller Messergebnisse gemäß dem im Folgenden dargestellten Untersuchungsablauf: 1. Beladen der µ-Kammer; 2. Probenahme der flüchtigen, kurzkettigen, organischen Säuren (ca. 0,5 bis 1 Stunde nach der Beladung für ca. 20 Stunden, 30 Liter Probenahmevolumen); 3. Probenahme der VOCs mit Tenax® (ca. 10 Minuten, 0,25 Liter Probenahmevolumen); 4. Probenahme Oxime und Piperidin-Derivate† mit Tenax® (ca. 40 Minuten, 1,0 Liter Probenahmevolumen); 5. Probenahme der Aldehyde und Ketone (für ca. 20 Stunden, 30 Liter Probenahmevolumen) Dabei werden 4 Sammlersysteme beladen und anschließend analysiert. Die mit dem BEMMA Schema entwickelten Summenwerte für flüchtige organische Stoffe sind im Wesentlichen vor dem Hintergrund der Emissionsminimierung aufgestellt worden. Es gibt für viele VOC keine eindeutige Wechselwirkung mit den Objekten in der Vitrine, zumal diese auch aus vielen verschiedenen Werkstoffen bestehen können und ein VOC nicht mit all diesen reagieren wird. Grundsätzlich „verdächtig“ sind natürlich alle reaktiven Stoffe, wie z. B. Isocyanate. Diese werden aber aus gut gelagerten oder ausreichend belüfteten Baumaterialien für Vitrinen nicht abgegeben. Anorganische Schadgase können zwar in der Umgebungsluft verstärkt auftreten - sind aber aus Baumaterialien nicht zu erwarten. Daher kann das BEMMA-Schema auch nur für einen Teil der luftgetragenen Schadstoffe eine sinnvolle Aussage treffen. Eines der Probleme bei der Bewertung vieler Kleb-/Dichtstoffe ist die Emission cyclischer Siloxane. Deren Schädigungspotential einzu¬schätzen wäre eine wichtige Aufgabe, um an dieser Stelle mehr Klarheit bei der Bewertung zu bekommen. T2 - Quo vadis BEMMA? Präventive Konservierung CY - BAM, Berlin, Germany DA - 07.09.2017 KW - Vitrinen KW - BEMMA KW - VOC KW - Emissionen PY - 2017 AN - OPUS4-43090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Ringversuche zur Bewertung von Geruch bei Bauprodukten N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Diese Methode an sich weist zahlreiche Faktoren auf, die das Untersuchungsergebnis beeinflussen können, als da wären die Konstanz der Parameter wie Luftwechselrate, Luftfeuchtigkeit und Temperatur oder die konkrete Präparation der Probe und deren Positionierung in der Kammer etc. Für die Probenahme von flüchtigen organischen Komponenten kommen noch die eher analytischen Faktoren dazu und für die geruchliche Bewertung lassen sich weitere Einflussgrößen identifizieren. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die ersten beiden dieser Ringversuche wurden mit hohem zeitlichen und personellen Aufwand begleitet. So fuhren in 2012 Mitarbeiter der BAM zu den Teilnehmern und begutachteten vor Ort die jeweils vorhandenen Bewertungs-einrichtungen. In 2014 und 2016 wurden jeweils Materialien verschickt, die sowohl eine geruchliche Bewertung als auch für die Bestimmung von VOC in der Prüfkammerluft geeignet waren. Parallel zu den Proben wurden eine sehr konkrete Anweisung verschickt, wie der Ringversuch durchzuführen war und weiterhin sehr ausführliche Fragebögen, deren Ergebnisse z. T. in die Neufassung der ISO-Norm einfließen sollen. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. T2 - Emissionsarme Bauprodukte und Wohngesundheit CY - Braunschweig, Germany DA - 22.03.2017 KW - Ringversuch KW - Emissionskammer KW - Referenzmaterial KW - Geruch PY - 2017 AN - OPUS4-40298 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Sauerwald, T. A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Schultealbert, C. T1 - Development of a reproducibly emitting reference material for volatile organic compounds N2 - The aim of this study is the development of a reproducibly emitting reference material for volatile organic compounds (VOC). The first part of the work was carried out with styrene, for which supporting materials were successfully selected, doped and analyzed in test chambers. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Quality control KW - Emission test chamber KW - Indoor air KW - Quality assurance PY - 2016 SN - 978-0-9846855-5-4 AN - OPUS4-36849 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Lima Vasconcelos, S. A1 - Sattler, M. A1 - Müller, B. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The Influence of textile floor coverings on the indoor air quality N2 - Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge). T2 - Clima 2019 Congress CY - Bucharest, Romania DA - 26.05.2019 KW - VOC Emissionen KW - Geruch KW - Bodenbelag KW - AgBB Bewertung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487341 DO - https://doi.org/10.1051/e3sconf/201911102051 SN - 2267-1242 VL - 111 SP - 02051-1 EP - 02051-6 PB - EDP Sciences AN - OPUS4-48734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 245 EP - 249 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49326 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Hahn, Oliver T1 - Neues BAM-Zertifizierungsverfahren für emissionsarme Materialien zum Bau von Museumsvitrinen N2 - Museumsvitrinen sollen Kunst- und Kulturgut „ins rechte Licht“ setzen und vor Diebstahl oder Vandalismus schützen. Vergleicht man historische Schauvitrinen, die zumeist aus einfachen Glasscheiben in Holzrahmungen bestehen, mit heutigen Konstruktionen, lässt sich eine Entwicklung zu hochtechnisierten Gebilden ablesen, die deutlich mehr Ansprüchen genügen müssen als in der Vergangenheit. Zahlreiche Beispiele verdeutlichen, dass Kunstwerke nicht nur außerhalb, sondern auch innerhalb von Museen oder Archiven ungünstigen Umwelteinflüssen ausgesetzt sind. So können Einbauten bzw. Dekorationen in Ausstellungsräumen, Aufbewahrungsbehältnisse in Depoträumen oder Ausstellungsvitrinen flüchtige Substanzen, sogenannte VOCs (Volatile Organic Compounds) freisetzen, die zu irreversiblen Veränderungen an den Objekten führen und diese schädigen. Hierzu zählen organische Säuren, wie Ameisen- oder Essigsäure, aber auch Verbindungen, die Sulfide enthalten. Hier wird die an der BAM entwickelte BEMMA-Bewertungsmethode vorgestellt, die von Museen verwendet werden kann Materialien mit einem geringeren Emissionspotential auszusuchen. KW - Museum KW - VOC-emission KW - BEMMA KW - Vitrine PY - 2020 SN - 2194-3648 VL - 2020 IS - zwei SP - 80 EP - 81 PB - SchmittART CY - Leipzig AN - OPUS4-51489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests N2 - In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system. Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received. Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better. T2 - International Conference on Risk Assessment of Indoor Air Chemicals CY - Berlin, Germany DA - 16.09.2018 KW - Chamber test KW - Round robin test KW - VOC-emission PY - 2018 AN - OPUS4-47906 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Selection of low emittiong material for the construction of display cases based on the BEMMA procedure N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. T2 - Materials Testing Symposium CY - New York City, USA DA - 06.11.2019 KW - Museum KW - Emission KW - Dispay case KW - BEMMA KW - VOC PY - 2019 AN - OPUS4-49589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Müller, B. A1 - de Lima Vasconcelos, S. A1 - Plehn, W. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Sattler, M. T1 - Präzisierung der Geruchsprüfung für Bauprodukte nach DIN ISO 16000-28 – Untersuchung von Vergleichsmaßstäben N2 - Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Geruch KW - Emission KW - Bauprodukte KW - VOC KW - Emissionskammer PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 214 EP - 223 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Brozowski, Frank A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte (Teil II): Anwendung eines Adapters und vereinfachtes Bewertungsverfahren T1 - Further Development of the Odour Measurement Method for Building Products (Part II) N2 - Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt. Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes. N2 - For technical improvement of sample presentation an adapter was developed to connect the emission test chamber with the evaluation funnel and thus enabling a more direct measurement. The analytical measurements demonstrate that the air has a very similar composition sampled at the funnel or in the emission test chamber. The results of the olfactory measurements show overall that the intensities determined using the adapter are often reported as lower. Further investigations have shown that air backflow via the funnel into the sample container of the adapter may be the cause. This has to be avoided in future. Another experimental series was carried out to reduce the measurement effort of evaluation of perceived intensity. Here application of the developed ‘greater than, or less than/equal to’ survey could be helpful. The results of the measurements in the air quality lab and in the frame of a round robin test indicate, that the survey leads to the same evaluation as the more complex determination of perceived intensity with standard method. KW - Geruchsmessung KW - VOC-Emission KW - Bauprodukte KW - Bewertungsverfahren PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549875 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 82 IS - 3-4 SP - 83 EP - 89 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-54987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Further Development of Odour Testing of Building Products – Sample Presentation and Evaluation of Perceived Intensity N2 - Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020. In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results. T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 CY - Online meeting DA - 21.06.2021 KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC KW - Perceived Intensity PY - 2021 SN - 978-82-536-1728-2 VL - 2021 SP - 1 EP - 4 PB - SINTEF Books CY - Oslo, Norwegen AN - OPUS4-54574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Panaskova, J. A1 - Müller, D. A1 - Plehn, W. T1 - Sensory tests for building materials and rooms - Status of the standardisation T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - sensory evaluation of building materials and rooms KW - Perceived air quality KW - Standardisation KW - Label KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 6 (3E.5) AN - OPUS4-27561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Wiegner, Katharina A1 - Horn, Wolfgang T1 - Comparison of different air sampling adsorbents for a screening method for SVOC T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Biocides KW - Air sampling KW - Micro-chamber KW - SDVB-polymer PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (6B.2) AN - OPUS4-27569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Hahn, Oliver A1 - Farke, M. T1 - Assessment of Emissions from Materials for Museum Equipment T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26229 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Nohr, Michael A1 - Richter, M. T1 - Development of a reference for the measurement of S(VOC) in Emission test chambers T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27494 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Nohr, Michael A1 - Richter, Matthias T1 - Generation of reproducible chamber concentrations for round robin tests based on reference materials T2 - Emission and Odours from Materials - 2013 CY - Brussels, Belgium DA - 2013-10-17 PY - 2013 AN - OPUS4-29629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Ringversuche zur Einführung von Geruchsmessungen in die Bewertung von Bauprodukten entsprechend der DIN ISO 16000-28 und VDI 4302-1 N2 - The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable. To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014. The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results. T2 - 17. Workshop - Geruch und Emissionen bei Kunststoffen CY - Kassel, Germany DA - 16.03.2015 PY - 2015 SP - 8-1 EP - 8-9 AN - OPUS4-33075 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung der Geruchsmessungen nach DIN ISO 16000-28 in die Bewertung von Bauprodukten N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessung KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukt PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/ringversuch-zur-einfuehrung-der-geruchsmessungen SN - 1862-4804 VL - 88/2014 SP - UBA-FB 002049, EP - 1-141 CY - Dessau-Roßlau AN - OPUS4-34885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung von Geruchsmessungen in Anlehnung an ISO 16000-28 N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessungen KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukte PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 84 EP - 90 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-31391 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Round Robin test for the implementation of odour measurements regarding ISO 16000-28 into the evaluation of buildings products - Part II (Specified by VDI 4302-1) N2 - While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons. KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/round-robin-test-for-the-implementation-of-odour SN - 1862-4804 VL - 79/2015 SP - UBA-FB 002199/E, 1-142 CY - Dessau-Roßlau AN - OPUS4-34886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Mölders, N. A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Mull, B. T1 - Two new promising approaches for quality assurance measures for materials emissions testing N2 - Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained. T2 - Indoor Air 2018 CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Emission reference material KW - Volatile organic compounds KW - CO2 assisted impregnation KW - FEM model PY - 2018 SP - 1 EP - 8 AN - OPUS4-45610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - BEMMA als Auswahlkriterium für Vitrinenbaumaterialien N2 - BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Ergebnisse der Untersuchungen seit ca. 2010 bis 2017 werden präsentiert und diskutiert. T2 - Ringvorlesung der HTW Analyse und Wahrnehmung: Kulturgut erforschen und erhalten CY - HTW Berlin, Germany DA - 16.01.2018 KW - Museumsvitrine KW - VOC-Emissionen KW - BEMMA Bewertung PY - 2018 AN - OPUS4-43828 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Zertifizierung emissionarmer Materialien für Museumsvitrinen N2 - Anregungen aus dem N.i.Ke.-Workshop 2017 und künftige Anforderungen. BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Hier wird der Status-Quo des Erreichten dargestellt. Wie wird das Schema in der Museumsöffentlichkeit wahrgenommen und seine Akzeptanz. T2 - BZS-Beirat CY - BAM, Berlin, Germany DA - 19.01.2018 KW - BEMMA KW - Museumsvitrinen KW - VOC-Emissionen PY - 2018 AN - OPUS4-43860 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Possible reference materials for proficiency tests for emission chamber tests N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Schultealbart, Caroline T1 - Reference materials for round robin tests for emission test chambers – a review N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Metrologie for indoor air quality CY - Berlin, Germany DA - 29.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Evaluation of material emissions for museum equipment – BEMMA-Scheme N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. The basic evaluation for the values used for first assessments were a ZIM-project with nearly 100 tested materials. In-between more than 100 new materials were tested and enlarged the knowledge about material emissions from display case materials. Mainly silicone sealing materials were tested due to the fact that this group of material have the highest emissions. With regard to the testing procedure only construction materials were evaluated, not the display cases their self. Nevertheless in combination with the certificate also designed by BAM additionally the further steps of construction can be taken into account. So other factors such as age and storage time of materials, tightness respectively air change rate, air condition or ventilation of display cases can be included in the evaluation. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Display cases KW - BEMMA KW - Museum KW - Emission KW - VOC PY - 2017 AN - OPUS4-41937 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, Birte A1 - Richter, Matthias A1 - Brödner, Doris T1 - Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers T1 - Entwicklung von Referenzmaterialien für Leistungstests bei Emissionskammermessungen N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT. Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions. The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber. Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results. N2 - Die Untersuchung von Produkten auf deren Emissionseigenschaften ist ein aktuell wachsender Aufgabenbereich für Messinstitute. Label werden für Bauprodukte auf Basis von Emissionskammermessungen vergeben, weshalb die dabei eingesetzten Messmethoden überprüft werden sollten. Ein Ringversuch (RV), bei dem ein homogenes Material von verschiedenen Laboratorien parallel untersucht wird, ist ein geeignetes Verfahren dafür. Für einen solchen Ringversuch aber auch generell für die laborinterne Qualitätssicherung ist es sehr hilfreich ein Referenzmaterial zu haben, um gut vergleichbare Ergebnisse zu erhalten. Generell kann jedes kommerziell erhältliche Produkt als Referenzmaterial verwendet werden, wenn es gut charakterisiert ist. Allerdings emittieren die meisten Produkte nur wenige VOC und diese sind typischerweise sehr materialspezifisch. Die Homogenität der Materialien ist nicht immer gegeben, so ist es besser, nach alternativen Materialien zu suchen. Es sind schon einige Veröffentlichungen zu reproduzierbar emittierenden Materialien verfügbar. Diese enthalten bislang zumeist nur ein einzelnes VOC – Toluol. Im Rahmen von zwei Forschungsvorhaben arbeitet die BAM an der Entwicklung von Referenzmaterialien für Emissionskammer-Untersuchungen, die einzelne VOC oder VOC-Mischungen emittieren. Der erste Ansatz war die Dotierung eines kommerziellen Lackes mit einer VOC/SVOC-Mischung, weitere Untersuchungen werden mit Thermo¬plastischem Polyurethan (TPU) sowie einer Squalan/Paraffin-Mischung durchgeführt. Da mit dem zweiten Ansatz noch Tests laufen, ist damit noch kein RV durchgeführt worden. Wichtige Anforderungen an ein Referenzmaterial sind die Wiederholbarkeit (Homogenität), Reprodu-zierbarkeit und Langzeitstabilität in Bezug auf die VOC-Abgabe und die Transportstabilität. Die Emissionsraten sollten hoch genug sein, um gut messbare Kammerluft-Konzentrationen bei Standardbedingungen zu erhalten. In einen wasserbasierten Lack wurde eine VOC/SVOC-Mischung zugegeben und nach der Durchmischung wurden davon einzelne Portionen in Petrischalen abgefüllt. Diese Schalen wurden unter Standardbedingungen (23 °C und 50% relative Luftfeuchtigkeit) getrocknet. Reproduzierbare Emissionen wurden erhalten, wenn die Lagerzeit ca. vier Wochen nicht überschritten wurde. Die Konzentrationen wurden sieben Tage nach der Beladung der Kammer bestimmt. Zwei RV wurden mit einem wie oben beschriebenen Lacksystem durchgeführt. Es nahmen ca. 50 Labore teil, diese mussten die Zielsubstanzen sowohl identifizieren als auch quantifizieren. Die gefundenen Mittelwerte und Standardabweichungen lagen jeweils im zu erwartenden Bereich für solch einen RV. T2 - Odour and Emission of Plastic Materials CY - Kassel, Germany DA - 21.03.2017 KW - Ringversuch KW - Round robin test KW - Emissionskammer KW - Emission test chamber KW - Referenzmaterial KW - Reference material PY - 2017 AN - OPUS4-40299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, B. A1 - Richter, Matthias A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol). T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Emissions testing KW - Volatile organic compounds KW - Polymeric material KW - CO2 assisted impregnation PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0172, 1 EP - 2 AN - OPUS4-42348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Development of gas standards to underpin indoor air measurements N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Webinar “Discussing impact on climate monitoring and indoor air quality measurements For registration press@inrim.it of EMRP KEYVOCs PROJECT” CY - www; webinar DA - 05.09.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Odour testing of building products: Examinations for an on-going development of the test standard ISO 16000-28 N2 - VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Building material KW - Odour KW - Perceived intensity KW - VOC KW - Emission test chamber PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580070 SP - 345 EP - 352 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - New developments in odour testing: Adapter connects emission test chamber and funnel N2 - Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented. The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test. The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far. T2 - CLIMA 2022 The 14th REHVA HVAC World Congress CY - Rotterdam, The Netherlands DA - 22.05.2022 KW - Perceived Intensity KW - Emissionen KW - Geruch KW - Bauprodukte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556192 DO - https://doi.org/10.34641/clima.2022.168 SP - 1 EP - 5 PB - TU Delft open CY - Delft, Niederlande AN - OPUS4-55619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Musyanovych, A. A1 - Grimmer, Christoph A1 - Sadak, A. E. A1 - Heßling, L. A1 - Bilsel, M. A1 - Horn, Wolfgang A1 - Richter, Matthias T1 - Polymeric Capsules with VOCs for Controlled Emission N2 - Micro-(nano-)encapsulation technology involves building of a barrier between the core and the environment and offers a number of benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of the payload. Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ [1] was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air. Different capsules in a size range between 5 and 50 μm were synthesized through an interfacial polyaddition/polycondensation reaction in direct (water-in-oil) system. As VOC several types of hydrophobic liquid materials were used. After synthesis, the morphology and physicochemical properties of capsules were characterized by electron microscopy, FTIR and DSC/TGA. An encapsulation efficiency up to 90% could be reached. The emission kinetic of volatile agents was studied in emission test chambers at 23 °C and 50% RH for 14 days. First results indicate that variation of the cross-linking grade of the shell material is one important parameter to adjust the desired emission rate. The overall aim is to achieve a consistent emission profile that decreases by less than 10 % over a target period of at least 14 days. T2 - 36th European Colloid & Interface Society Conference CY - Chania, Crete, Greece DA - 04.09.2022 KW - Capsules KW - Volatile organic compound KW - Polymer KW - Material emissions KW - Reference materials PY - 2022 AN - OPUS4-56039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brosig, L. A1 - Müller, B. A1 - Mertes, A. A1 - de Lima Vasconcelos, S. T1 - Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude – Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht N2 - Menschen, die in der gemäßigten Klimazone leben, verbringen bis zu 90% ihres Lebens in Innenräumen. Deshalb hat das Innenraumklima eine sehr große Bedeutung für deren Wohlergehen, Gesundheit und Leistungsfähigkeit. In Deutschland wird ca. 40% der eingesetzten Primärenergie für das Heizen, Kühlen und Klimatisieren der Innenräume verwendet. Das Forschungsvorhaben hat eine Laufzeit vom Oktober 2013 bis März 2017. Es wird in Kooperation mit der Bundesanstalt für Materialforschung und –prüfung (BAM) und der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) durchgeführt. Die HTW Berlin koordiniert das Projekt. Die Rheinisch-Westfälische Technische Hochschule Aachen (RWTH) wird teilweise über einen Auftrag in das Projekt integriert. Ziel des Projektes ist es Baustoffe auf ihre Geruchsemissionen zu untersuchen, um Bauprodukte mit niedrigen Emissionen und Gerüchen identifizieren zu können. Den Verbraucherinnen und Verbrauchern wird somit die Möglichkeit gegeben emissions- und geruchsarme Baustoffe zu wählen. Die Aufgabenstellung des Projektes ist nachfolgend aufgeführt: Arbeitspaket 1: Geruchsmessung bei Produkten mit dem Blauen Engel (siehe Kapitel 4 und 5); Arbeitspaket 2: Untersuchung von Vergleichsmaßstäben (siehe Kapitel 6); Arbeitspaket 3: Untersuchung der Linearität der Acetonskala (siehe Kapitel 7); Arbeitspaket 4: Erstellung einer Produktdatenbank (siehe Kapitel 8). Die Geruchsuntersuchung ist in den Vergabekriterien für den „Blauen Engel“ für textile Bodenbeläge (RAL UZ-128) eingebunden worden. Aus den weiteren Untersuchungen sind für die Normung wichtige Erkenntnisse erarbeitet worden. KW - VOC Emissionen KW - Geruch KW - Bewertung KW - Innenraumluftqualtität KW - Bodenbeläge PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487223 UR - https://www.umweltbundesamt.de/publikationen/emissions-geruchsarme-bauprodukte-fuer UR - https://www.umweltbundesamt.de/sites/default/files/medien/1410/publikationen/2019-08-20-texte_92-2019_emissionsarme-bauprodukte.pdf SN - 1862-4804 VL - 92 SP - 1 EP - 106 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-48722 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Volatile organic compounds from building products - Results from seven proficiency tests with emission test chambers conducted between 2008 and 2021 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%. T2 - Proficiency Testing in Analytical Chemistry, Microbiology and Laboratory Medicine CY - Windsor, United Kingdom DA - 25.09.2023 KW - Proficiency Test KW - VOC-Emission KW - Chamber-test PY - 2023 AN - OPUS4-59694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias T1 - Round robin tests of odour and VOC emissions from building products – What have we learned so far? N2 - Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Perceived intensity KW - VOC-emission KW - Poficiency test KW - Chamber test KW - Odour PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580001 SP - 434 EP - 436 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 DO - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Burbiel, M. A1 - Wilke, Olaf A1 - Kalus, Sabine ED - Levin, H. T1 - Biocide emissions from materials into indoor air N2 - The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined. T2 - 9th International Conference on Indoor Air Quality and Climate CY - Monterey, CA, USA DA - 2002-06-30 KW - SVOC KW - Biocide KW - Chamber test KW - Polyurethane foam KW - Testing method PY - 2002 UR - http://www.irbnet.de/daten/iconda/CIB6909.pdf SN - 0-9721832-0-5 VL - 2 SP - 926 EP - 930 PB - International Academy of Indoor Air Sciences CY - Santa Cruz, Calif. AN - OPUS4-2000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Hahn, Oliver A1 - Jann, Oliver A1 - Kalus, Sabine T1 - Do Particleboards produced with recycled wood contribute to indoor air pollution with biocides? T2 - 7th International Conference Healthy Buildings 2003: Energy-Efficient Healthy Buildings CY - Singapore DA - 2003-07-13 PY - 2003 AN - OPUS4-3239 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Hahn, Oliver A1 - Jann, Oliver A1 - Kalus, Sabine ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Do particleboards produced with recycled wood contribute to indoor air pollution with biocides? T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - SVOC KW - Biocide KW - Chamber study KW - Material emission KW - Wood PY - 2003 SN - 981-049974-4 VL - 1 SP - 367 EP - 372 CY - Singapore AN - OPUS4-3419 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Gellert, R. T1 - Emission test methods for thermal insulation products according to interpretative document No. 3 hygiene, health and the environment T2 - Emissions and Odours From Materials CY - Brussels, Belgium DA - 2004-09-22 PY - 2004 AN - OPUS4-4131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kasche, J. A1 - Dahms, A. A1 - Müller, B. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Olfaktorische Bewertung von Baumaterialien T2 - 7th Workshop "Odour and Emissions of Plastic Materials" CY - Kassel, Germany DA - 0005-04-04 KW - Bauprodukte KW - Emissionen KW - Geruch KW - Kammerverfahren KW - VOC PY - 2005 SP - 5-1-5-12 PB - Kassel University Press GmbH CY - Kassel AN - OPUS4-7363 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Schoknecht, Ute A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wegner, R. T1 - Biozidemissionen aus Materialien - Umweltforschungsplan des Bundesministeriums für Umwelt, Naturschutz und Reaktorsicherheit PY - 2002 SP - 1 EP - 139 CY - Berlin AN - OPUS4-7299 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Entwicklung einer Prüfmethode und Untersuchungen zur Begrenzung von Emissionen aus Druckern und Kopiergeräten im Rahmen der Umweltzeichenvergabe (Forschungsbericht 201 95 311/02 / UBA-FB 000510) N2 - An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unterschiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. KW - Emissionen KW - VOC KW - Ozon KW - Staub KW - Hardcopygerät KW - Drucker KW - Kopierer KW - Emissionsmesskammer KW - Umweltzeichen PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/entwicklung-einer-pruefmethode-untersuchungen-zur SN - 1862-4804 SN - 0722-186X IS - 71 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7276 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Burbiel, M. T1 - Biocide Emissions from Materials Into Indoor Air T2 - 9th International Conference on Indoor Air Quality and Climate - Indoor Air 2002 CY - Monterey, CA, USA DA - 2002-06-30 PY - 2002 AN - OPUS4-3428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, B. T1 - Emission and odour measurement of construction products evaluated using a German construction product evaluation scheme T2 - Emissions and Odours From Materials CY - Brussels, Belgium DA - 2004-09-22 PY - 2004 AN - OPUS4-4132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Gellert, R. A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris T1 - Emission tests on thermal insulation products with the intention to implement these tests into EN standards T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Bauprodukte KW - Emissionen KW - Dämmstoffe KW - Kammerverfahren KW - VOC KW - EN-Standards KW - Insulation material KW - VOC emission KW - Chamber copmparison KW - Construction products directive KW - AgBB-scheme PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 1886 EP - 1890 PB - Tsinghua University Press CY - Beijing AN - OPUS4-7612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria ED - de Oliveira, F. ED - Gameiro da Silva, M. ED - Pinto, R. T1 - Classification of OSB Emissions Assessed with a German Evaluation Scheme T2 - 8th International Conference "Healthy Buildings" CY - Lisboa, Portugal DA - 2006-06-04 KW - Construction product KW - VOC emission KW - Odour KW - Chamber test KW - AgBB-Scheme KW - OSB PY - 2006 VL - 4 SP - 59 EP - 62 PB - Universidade do Porto CY - Lissabon AN - OPUS4-12448 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Emissonsmessungen an Materialien mit Hilfe von Prüfkammern sowie direkter thermischer Extraktion T2 - Gerstel-Anwenderseminare Frühjahr 2005 CY - Hanover, Germany DA - 2005-06-02 PY - 2005 AN - OPUS4-11446 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Anwendung des AgBB-Schemas auf die Emission von Bauprodukten T2 - 12. WaBoLu Innenraumtage, Umweltbundesamt CY - Berlin, Germany DA - 2005-05-02 PY - 2005 AN - OPUS4-11447 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Müller, B. A1 - Jann, Oliver A1 - Kasche, J. A1 - Däumling, C. A1 - Kalus, Sabine A1 - Brödner, Doris T1 - Emission and odour measurement of construction products evaluated using a German construction product evaluation scheme T2 - 10th international Conference on Indoor Air Quality and Climate - Indoor Air 2005 CY - Beijing, China DA - 2005-09-04 PY - 2005 AN - OPUS4-11485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Gellert, R. A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris T1 - Emission tests on thermal insulation products with the intention to implement these tests into EN standards T2 - 10th international Conference on Indoor Air Quality and Climate -Indoor Air 2005 CY - Beijing, China DA - 2005-09-04 PY - 2005 AN - OPUS4-10934 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rockstroh, Jens A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Kalus, Sabine A1 - Jann, Oliver ED - de Oliveira, F. ED - Gameiro da Silva, M. ED - Pinto, R. T1 - Investigations on the Emission of organic Acids from Building Products in Emission Test Chambers - Development of a new Test Method T2 - 8th International Conference "Healthy Buildings" CY - Lisboa, Portugal DA - 2006-06-04 KW - Building products KW - Organic acids KW - VOC KW - GC/MS PY - 2006 VL - 4 SP - 45 EP - 48 PB - Universidade do Porto CY - Lissabon AN - OPUS4-12447 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Müller, B. A1 - Jann, Oliver A1 - Kasche, J. A1 - Däumling, C. A1 - Kalus, Sabine A1 - Brödner, Doris T1 - Emission and odour measurement of construction products evaluated using a german construction product evaluation scheme T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - AgBB-Scheme KW - Construction product KW - VOC emission KW - Odour KW - Chamber test PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 2129 EP - 2133 PB - Tsinghua University Press CY - Beijing AN - OPUS4-10913 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Emissions- und Geruchsuntersuchungen an Bauprodukten - Ergebnisse eines UFO-Planprojektes T2 - 8. Workshop "Geruch und Emissionen bei Kunststoffen" / Universität Kassel CY - Kassel, Germany DA - 2006-03-27 PY - 2006 AN - OPUS4-12264 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, B. A1 - Bitter, F. A1 - Müller, D. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Goschnick, J. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Chanie, E. A1 - Ruponen, M. T1 - Messung der empfundenen Geruchsintensität mit Multigas-Sensorsystemen, das Forschungsvorhaben SysPAQ KW - Geruch KW - Sensorsystem KW - Perceived Air Quality KW - Produkttypischer Geruch KW - Bauprodukte KW - Emissionen PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 17 EP - 29 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16370 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf T1 - Durchführung eines Rundversuchs zur Messung von flüchtigen organischen Verbindungen im Rahmen der gesundheitlichen Bewertung von Bauprodukten, Interlaboratory study on VOC emission testing T2 - Abschlussveranstaltung zum Vorhaben 4532 "Durchführung eines Rundversuchs zur Messung von flüchtigen organischen Verbindungen im Rahmen der gesundheitlichen Bewertung von Bauprodukten, DIBt CY - Berlin, Germany DA - 2008-04-09 PY - 2008 AN - OPUS4-17615 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf T1 - Europäischer Rundversuch zur Bestimmung von VOC mittels Thermodesorption T2 - 15. WaBoLu-Innenraumtage, Umweltbundesamt CY - Berlin, Germany DA - 2008-04-28 PY - 2008 AN - OPUS4-17616 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kasche, J. A1 - Dahms, A. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory evaluation of building products - Results of a German round robin test T2 - VDI-Tagung CY - Bad Kissingen, Deutschland DA - 2007-11-13 KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Blauer Engel PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 193 EP - 202 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Dürkop, J. A1 - Horn, Wolfgang A1 - Englert, N. A1 - Plehn, W. T1 - Building products: Determining and avoiding pollutants and odours - Results from a research project KW - Building products KW - Emissions KW - Odour KW - AgBB-Scheme KW - Chamber tests PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/building-products-determining-avoiding-pollutants SP - 1 EP - 100 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-15999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Brandt, S. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Möglichkeiten und Grenzen der Bewertung und Kennzeichnung geruchsarmer Bauprodukte und Einrichtungen T2 - VDI-Tagung CY - Bad Kissingen, Deutschland DA - 2007-11-13 KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Blauer Engel PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 181 EP - 191 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16321 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Goschnick, J. A1 - Häringer, D. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Chanie, E. A1 - Ruponen, M. A1 - Müller, D. T1 - Measuring perceived air quality and intensity by a Sensor System, the European Project SysPAQ T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Perceived air quality KW - Perceived odour intensity KW - Profiling KW - Sensor system PY - 2008 IS - Paper ID: 530 SP - 1 EP - 8 AN - OPUS4-18302 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Däumling, C. A1 - Brenske, K.-R. A1 - Crump, D. A1 - Funch, L. W. A1 - Hansen, K. A1 - Horn, Wolfgang A1 - Kephalopoulos, S. A1 - Maupetit, F. A1 - Saarela, K. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of material emission labelling schemes in the EU T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Labelling scheme KW - Evaluation system KW - Material emission KW - Harmonisation PY - 2008 SP - 1 AN - OPUS4-18046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Juritsch, Elevtheria A1 - Ramalho, O. A1 - Wargocki, P. A1 - Knudsen, H. A1 - Müller, B. T1 - Detecting odorous compounds emitted from building and consumer products within the European Project SysPAQ T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Olfactory detection port KW - VOC analysis KW - Thermal extraction KW - Building material KW - Consumer products PY - 2008 IS - Paper 230 SP - 1 AN - OPUS4-18045 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria A1 - Müller, B. A1 - Müller, D. A1 - Kasche, J. T1 - Chemische analytische Bewertung von Baustoffemissionen T2 - Deutsche Kälte-Klima-Tagung 2008 CY - Ulm, Deutschland DA - 2008-11-20 KW - AgBB-Schema KW - VOC KW - Emissionen KW - Bauprodukte KW - Bewertung Emissionen PY - 2008 IS - AA.IV.15 SP - 1 EP - 8 AN - OPUS4-18406 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria T1 - Emissionen flüchtiger organischer Verbindungen aus Bauprodukten T2 - VDI Wissensforum "Schadstoffe in Bauprodukten" CY - Mannheim, Deutschland DA - 2008-11-12 KW - Emissionen KW - Bauprodukte KW - Emissionsmesskammern KW - VOC KW - SVOC KW - Geruch KW - AgBB PY - 2008 SP - 1 EP - 22 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-18452 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Chemisch analytische Bewertung von Baustoffemissionen T2 - Deutsche Kälte-Klima-Tagung 2008 CY - Ulm, Germany DA - 2008-11-20 PY - 2008 AN - OPUS4-18475 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, B. A1 - Danielak, M. A1 - Müller, D. A1 - Plehn, W. T1 - Bauproduktprüfung und Geruch - Neue Entwicklungen im Rahmen von Label-Systemen T2 - 11. Workshop - Geruch und Emissionen bei Kunststoffen CY - Kassel, Deutschland DA - 2009-03-30 KW - AgBB-Schema KW - VOC KW - Emissionen KW - Geruch KW - Bauprodukte KW - Bewertung Emissionen PY - 2009 SP - 8-1 - 8-9 AN - OPUS4-19224 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Bauproduktüberprüfung und Geruch - Neue Entwicklungen im Rahmen von Label-Systemen T2 - 11. Workshop "Odour and Emissions of Plastic Materials" CY - Kassel, Germany DA - 2009-03-30 PY - 2009 AN - OPUS4-19331 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Bremser, Wolfram A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria A1 - Till, Carola T1 - Untersuchungen zur Verbesserung der Messung von flüchtigen organischen Verbindungen aus Fußbodenbelägen im Rahmen der gesundheitlichen Bewertung von Bauprodukten T1 - Investigations for the improvement of the measurement of volatile organic compounds from floor coverings within the health-related evaluation of construction products N2 - In den Grundsätzen des DIBt zur gesundheitlichen Bewertung von Bauprodukten in Innenräumen ist das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (AgBB-Schema) als wesentliche Grundlage enthalten. Dieses Schema bewertet die mit Hilfe einer Prüfkammermessung bestimmten Emissionen von flüchtigen und schwer flüchtigen organischen Verbindungen (VOC und SVOC). Die Prüfkammer dient dabei der Einhaltung standardisierter Klimabedingungen (Temperatur 23°C, relative Luftfeuchtigkeit 50 %) sowie der Einstellung bestimmter Prüfparameter wie Luftwechselrate und Beladungsfaktor. Die Anforderungen an eine Prüfkammer sind in DIN EN ISO 16000-9 beschrieben. Die Analytik und Quantifizierung der VOC geschieht mittels Tenax-Thermodesorption und nachfolgender Gaschromatographie gekoppelt mit Massenspektrometrie und ist in DIN ISO 16000-6 beschrieben. Probenahmen werden am 3. und 28. Tag der Prüfkammermessung durchgeführt. Am dritten Tag erfolgt eine Bewertung der Emissionen aus dem Bauprodukt anhand des TVOC-Wertes und der Summe der detektierten cancerogenen Stoffe (nach 67/548/EWG, Einstufung als cancerogen der Kategorie 1 und 2). Ein Produkt erfüllt die Kriterien, wenn der TVOC-Wert nach 3 Tagen nicht größer als 10 mg/m³ ist und die Summe der Cancerogene 10 μg/m³ nicht übersteigt. Am 28. Tag wird zusätzlich zum TVOC-Wert und den Cancerogenen die Emission von SVOCs berücksichtigt und eine Einzelstoffbewertung anhand von NIK-Werten vorgenommen. Der TVOC-Wert nach 28 Tagen darf nicht größer als 1 mg/m³ sein, die Summe der Cancerogenen nicht größer als 1 μg/m³. Die Summe an SVOCs darf eine Konzentration von 0,1 mg/m³ nicht überschreiten. Der sogenannte R-Wert, die Summe aller Quotienten aus Einzelstoffkonzentration und dem NIK-Wert des Einzelstoffes, darf einen Wert von 1 nicht übersteigen. Außerdem darf die Summe von Substanzen, die keinen NIK-Wert besitzen, nicht größer als 0,1 mg/m³ sein. Der Ringversuch, der im Rahmen der Untersuchungen zur Verbesserung der Prüfkammermessungen durchgeführt wurde, hatte vor allem den Zweck, den Einfluss unterschiedlicher Methodenparameter bei der Prüfkammermessung in unterschiedlichen Prüflaboratorien zu erfassen. Anhand der Ergebnisse sollte eine Ursachenforschung für die großen Abweichungen der bisher durchgeführten Ringversuche erfolgen. Durch die drei aufeinander aufbauenden Schritte sollte der Einfluss der Analytik, der Probenahme und der Prüfkammer geklärt werden. Der Ringversuch diente nicht der Anerkennung der teilnehmenden Prüflaboratorien im Bereich der Bauproduktenprüfung für eine DIBt-Zulassung. Ausgehend von den Prüflaboratorien, die in der Projektgruppe „Prüf- und Messverfahren zur gesundheitlichen Bewertung von Bauprodukten“ des DIBt mitarbeiteten, wurde der Kreis auf europäische Prüflaboratorien erweitert, die sich ebenfalls mit Prüfkammermessungen an Bauprodukten beschäftigen. Dazu erging ein Einladungsschreiben an alle von vorangegangenen Ringversuchen bekannten Teilnehmer. Insgesamt ergab sich ein Teilnehmerkreis von 29 Instituten, davon 16 aus Deutschland, jeweils zwei aus Österreich, Belgien, Schweden, Dänemark und jeweils eins aus Finnland, Großbritannien, Frankreich, Italien und Portugal. Vor Beginn des Ringversuches waren davon 11 im Zulassungsbereich tätig. Zur wissenschaftlichen Begleitung wurde durch das DIBt ein Betreuergremium einberufen. In zwei Sitzungen (April und November 2007) wurden die aktuellen Ergebnisse vorgestellt und diskutiert sowie die weitere Vorgehensweise besprochen. Eine Abschlussveranstaltung nach der Auswertung des dritten Schrittes des Ringversuches fand im April 2008 im DIBt statt. Dazu waren alle Teilnehmer eingeladen. Für die Emissionsmessung von flüchtigen organischen Verbindungen (VOC) aus Materialien mit Hilfe von Emissionsprüfkammern sind bisher nur wenige Ringversuche durchgeführt worden (De Bortoli et al. 1999; Jann et al. 2000; Hansen et al. 2000; Oppl and Winkels 2002; Windhövel and Oppl 2005; Kirchner 2007; Oppl 2008). Dabei zeigten sich meist große Streuungen der Ergebnisse. Ein großes Problem für die Durchführung solcher Ringversuche ist das Fehlen von Referenzmaterialien mit bekannter Emissionsrate von Zielsubstanzen. Deshalb orientiert man sich für die Auswertung solcher Ringversuche am Mittelwert aller Ergebnisse. Dafür ist die Homogenität des Testmaterials von größter Bedeutung. Diese wurde in früheren Ringversuchen nicht wirklich sichergestellt. Im hier beschriebenen Forschungsprojekt wurde auf die Homogenität des Probenmaterials besonderen Wert gelegt. Der gesamte Ringversuch wurde in drei Schritte unterteilt. Die einzelnen Schritte wurden dabei von Schritt zu Schritt immer komplexer. Im ersten Schritt erfolgte die Analyse von flüssigen Lösungen, im zweiten die Bestimmung von VOCs in Prüfkammerluft und im dritten Schritt erfolgte eine komplette Emissionsprüfkammermessung bei den Teilnehmern. N2 - In the German Institute for Construction Technology’s (DIBt) principles for the health assessment for construction products used in interiors, the Evaluation procedure of the Committee for Health-related Evaluation of Building Products (AgBB Scheme) is contained as a substantial base. This scheme evaluates the emissions of volatile and semivolatile organic compounds (VOC and SVOC), determined by test chamber measurements. Within the interlaboratory comparison, which was divided into three steps, the emission test method from building products was checked against the principles of health-related evaluation of construction products in indoor spaces (based on DIN EN ISO 16000-9 together with DIN ISO 16000-6) with the co-operation of 29 European test institutes. The objective was to assess the comparability of the test method carried out in different test Chambers and using different thermodesorption devices. In the first step the analysis of liquid solutions took place to observe the influence of the analysis itself. In the second step VOCs were sampled in the air of a BAM test chamber onto tubes from the participants for the Analysis by them. In the third step a complete Emission test chamber measurement was carried out by the participants. A major problem for the execution of such interlaboratory comparisons is the lack of reference materials. Therefore the homogeneity of the test material was of great importance. As a result of the first step (analysis of 4 liquid solutions) a standard deviation of less than 20 % for 8 out of 11 substances tested was obtained. The Standard deviations for dichloropropanol, caprolactam and Butyl diglycol ranged up to 36 %. The second step, which included air sampling at a BAM test chamber, resulted in only one standard deviation value less than 20 % (11 % for styrene). The standard deviations for the other six substances were between 20 % and 36 %. For step 3 a sealant was chosen instead of the flooring material for homogeneity reasons. In step 3 the standard deviations for 4 of the 7 measured VOC concentrations from two chamber tests were between 17 % and 19 % and thus within the same range as in Step 1 and even better than for most substances in Step 2. A Standard deviation of 60 % was found for the key component ethanediol, but this can be explained with the difficult analysis method for this substance. A second objective of the project was to formulate criteria against which the specialist competence of the test institutes for emission tests can be checked and based on the principles for the health assessment for construction products used in interior. For this purpose a catalogue of criteria has been developed, which is divided into three parts. In the first part, basic requirements are formulated such as impartiality, accreditation for test chamber measurements, verification of experience by participation in earlier interlaboratory comparisons and the laboratory equipment. The second part requires the test-specific proof in the form of successful participation in interlaboratory comparisons organised by BAM biannually. The third part instructs the laboratories that they must ensure they are always upto-date both in terms of their knowledge and the available equipment. The quality assurance for the knowledge is ensured by regular participation in the exchanging of experience between the test laboratories. In terms of technical requirements the test institutes must be willing to successfully participate in at least one interlaboratory comparison per year. The present interlaboratory comparison was not designed to recognise the participating test laboratories in the field of the construction product testing for a DIBt approval. KW - Ringversuch KW - Laborvergleich KW - VOC-Emissionen KW - Kammermessungen KW - Round robin KW - Inter laboratory study KW - VOC emissions KW - Emission test chamber PY - 2009 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-198380 UR - https://www.baufachinformation.de/buch/Untersuchungen-zur-Verbesserung-der-Messung-von-fl%C3%BCchtigen-organischen-Verbindungen-aus-Fu%C3%9Fbodenbel%C3%A4gen-im-Rahmen-der-gesundheitlichen-Bewertung-von-Bauprodukten/230803 SN - 978-3-8167-8100-4 N1 - Sprachen: Deutsch/Englisch - Languages: German/English IS - T 3217 SP - 1 EP - 206 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-19838 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kephalopoulos, S. A1 - Däumling, C. A1 - Crump, D. A1 - Funch, L. W. A1 - Horn, Wolfgang A1 - Maupetit, F. A1 - Saarela, K. A1 - Säteri, J. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of indoor material emission labelling schemes in the EU - VOC workshop T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Labelling schemes KW - Indoor material emissions KW - VOC KW - Framework KW - Harmonisation PY - 2009 IS - Paper 635 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19925 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Danielak, M. A1 - Zeidler, O. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Panaskova, J. A1 - Plehn, W. T1 - Labelling of building materials - A combination of emission tests with odour tests T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Labelling systems KW - VOCs KW - Odour KW - Sensory tests KW - Emission tests PY - 2009 IS - Paper 323 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The blue angel - VOC workshop T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - AgBB-Scheme KW - Labeling KW - VOC emission PY - 2009 IS - Paper 427 SP - 1 EP - 3 CY - Syracuse, NY, USA AN - OPUS4-19924 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensorische Bewertung der Emissionen aus Bauprodukten - Integration in die Vergabegrundlagen für den Blauen Engel und das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissionen aus Bauprodukten beeinträchtigen die Qualität der Innenraumluft erheblich. Mit Hilfe des AgBB-Schemas werden die Emissionen flüchtiger organischer Verbindungen (VOC) aus Bauprodukten bewertet. Die gesundheitliche Bewertung nach dem AgBB-Schema erfordert produktspezifische Messverfahren. Diese gibt es mittlerweile für eine Reihe von Produkten. Sie wurden durch Beteiligung verschiedener Forschungseinrichtungen und Messinstitute validiert und u. a. in die Vergabekriterien des Umweltzeichens Blauer Engel übernommen. Die Bewertung ist allerdings –mit zumeist niedrigeren Grenzwerten –strenger. VOC-Emissionen und Gerüche können beide zu gesundheitlichen Belastungen führen. So ist die sensorische Prüfung ein weiteres wichtiges Element bei der Bewertung von Bauprodukten und vorsorglich auch im AgBB-Schema verankert. Hauptziel des Projektes ist es, eine Methode der sensorischen Bewertung und Grenzen für die Vergabe des Blauen Engels und für das AgBB-Schema abzuleiten. Auf Grundlage der durchgeführten Untersuchungen (siehe Kapitel 5 Ergebnisse und Diskussion) wird als Bewertungsmethode die empfundene Intensität und die Hedonik vorgeschlagen. Die Ableitung der Grenzwerte für die sensorische Bewertung am 28. Tag erfolgt über die zusätzliche Befragung der Probanden im Rahmen der vorliegenden Studie nach der Zumutbarkeit einer Probe. Für den Blauen Engel könnte es je Produktgruppe unterschiedliche Grenzen der empfundenen Intensität und der Hedonik geben. Ein erster Vorschlag für mögliche Grenzen, hier zunächst einheitlich für alle Produktgruppen, ist für die empfundene Intensität 7 pi (5 pi + 2 pi als Sicherheit, Kapitel 5.1.5) und für die Hedonik -1 (0 +/-0,8, gerundet auf -1) (siehe dazu Abbildung 6-2). KW - Bauprodukt KW - Schadstoff KW - Prüfverfahren KW - Blauer Engel KW - SVOC KW - Flüchtige Emission KW - Kohlenwasserstoff KW - Geruch KW - Sensorik KW - AgBB-Schema PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensorische-bewertung-emissionen-aus-bauprodukten SN - 1862-4804 IS - 35 SP - 1-146, Anhang 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-24926 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver ED - Brozio, P. T1 - Schadstoffe im Museum richtig einschätzen N2 - Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen. KW - Emissionsarme Vitrinen KW - Präventive Konservierung KW - VOC KW - BEMMA PY - 2011 SN - 978-3-7667-1962-1 SP - 127 EP - 131 PB - Callwey CY - München AN - OPUS4-25377 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Kalus, Sabine A1 - Horn, Wolfgang T1 - Determination of formic and acetic acids in air N2 - Formic and acetic acids are often responsible for damage of cultural objects, e. g. glass and metal corrosion or changing and fading of colours. Museums all around the world are equipped with different show cases. Display cases should protect cultural objects from dust as well as from mechanical damage. Several construction materials which are used for display cases, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs), volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs). These construction products can emit formic and acetic acids into the indoor or display case air. Modern display cases with small air change rates can cause higher concentrations of formic and acetic acids if any source is installed in the display case (Salthammer and Uhde, 2009). To minimize the risk of damage emissions from building products must be quantified. There is a need for a method for identification and quantification of acetic and formic acid. Some possibilities for the identification of acetic acid exist. The quantification of acetic acid for example after sampling on TENAX® or CARBOTRAP and thermal desorption-GC in accordance with ISO 16000-6 and ISO 16017-1 results in very low recovery rates. A new method should be stabile, robust, reproducible and comparable, with an easy local sampling and determination in laboratories. Miniaturised emission test chambers and model display cases were used to study the recovery rates. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOCs KW - Detection of formic and acetic acid KW - Quantification of formic and acetic acid KW - Air sampling PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Müller, B. A1 - Panaskova, J. A1 - Jann, Oliver A1 - Plehn, W. A1 - Müller, D. T1 - VOC emissions from building materials accompanying sensory tests for different evaluation schemes N2 - Within a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300). The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information. Beyond that many complaints according to building products are caused by odors. Therefore an evaluation procedure for the odor is very important and should be implemented into all of the mentioned labeling schemes. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Odor KW - Construction product KW - VOC-emission KW - Evaluation KW - AgBB PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina T1 - Inter-laboratory study to check the performance ot test chamber measurements for product emission testing N2 - The labelling of construction products or building materials as “low-emitting” is based on measurements using third-party emission test chambers. Unfortunately there is no method to validate the performance of such test chamber measurements. This might give a Variation of results when testing one material at different laboratories. Therefore it is necessary to hold round robin tests as part of the quality management System to ensure comparable results. A research project financed by the Federal Environmental Agency focused on the development of an external quality management System for the detection of relevant Chemical compounds from products and in ambient air. The project was structured in four phases (Horn et al., 2009 and 2011; Wilke et al., 2009a) This paper shows results of the fourth phase of the project, which was an inter-laboratory study for VOC-emission testing by means of emission test chambers. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Emission test chamber KW - Product emission testing KW - VOC-Emission KW - Round robin test PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Carcinogens and automated evaluation "ADAM" T2 - EC Workshop: Harmonised Framework on indoor material labelling schemes: challenge with a global perspective CY - Somma Lombardo, Italy DA - 2010-06-07 PY - 2010 AN - OPUS4-21505 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Sensorische Bewertung von Bauprodukten - Ergebnisse VOC T2 - Abschlussveranstaltung "Sensorische Bewertung von Bauprodukten" CY - Berlin, Germany DA - 2010-03-08 PY - 2010 AN - OPUS4-21021 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Jakob, B. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Häringer, D. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Loubet, F. A1 - Ruponen, M. T1 - Measuring perceived air quality and intensity by means of sensor systems, the European Project SysPAQ T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Sensor systems KW - Perceived air quality KW - Perceived intensity PY - 2009 IS - Paper 326 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 2 - Tenax tubes spiked by BAM T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 345 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Danielak, M. A1 - Müller, Birgit A1 - Jann, Oliver A1 - Plehn, W. A1 - Müller, D. T1 - Implementation of odour test methods into labelling procedures of flooring materials T2 - Conference of Healthy Buildings 2009 CY - Syracuse, NY, USA DA - 2009-09-13 PY - 2009 AN - OPUS4-20008 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Conference of Healthy Buildings 2009 CY - Syracuse, NY, USA DA - 2009-09-13 PY - 2009 AN - OPUS4-20006 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Den Schadstoffen auf der Spur - Die Bewertung von Emissionen aus Materialien für Museumsausstattungen mithilfe des neuen BEMMA-Schemas N2 - Ausstellungskuratoren, Restauratoren oder Fachplaner stehen immer wieder vor der Entscheidung, geeignete Materialien für Museumsausstattungen auswählen zu müssen. Vitrinen, Depoteinrichtungen, aber auch Transportverpackungen für Kunst- und Kulturgut sollten unbedingt frei von Schadstoffen sein. Ein neues Verfahren ermöglicht nun eine problemorientierte Untersuchung und Bewertung von Materialien mit belastbaren und reproduzierbaren Ergebnissen. KW - BEMMA KW - Emissionsarme Vitrine KW - Schadstoffe PY - 2012 SN - 0933-4017 VL - 3 SP - 38 EP - 44 PB - Callwey CY - München AN - OPUS4-25794 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Stephan, Ina A1 - Nohr, Michael A1 - Horn, Wolfgang T1 - Development of methods for testing of microbiological contamination of small climate control units for air in display cases T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Microbiological contamination KW - Acetic and formic acid KW - Conductivity KW - Climate control device KW - Display case KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5H.2) AN - OPUS4-27562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Mull, Birte A1 - Nohr, Michael A1 - Stephan, Ina A1 - Farke, M. T1 - Developement of methods for testing of microbiological contamination of small climate control units for air in display cases T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26228 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -