TY - CONF A1 - Horn, Wolfgang A1 - Panaskova, J. A1 - Jann, Oliver A1 - Müller, B. A1 - Müller, D. A1 - Plehn, W. T1 - Labelling of building materials - A combination of emission tests with odour tests T2 - HEMICPD workshop: Building Material Emissions to indoor air Opportunities/consequences for Belgian companies CY - Brussels, Belgium DA - 2010-01-21 PY - 2010 AN - OPUS4-20858 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Nohr, Michael A1 - Richter, Matthias T1 - Emissions from products into indoor air: Important factors for interlaboratory studies with emission test chambers T2 - Airmon - 2014 CY - Marseille, France DA - 2014-06-14 PY - 2014 AN - OPUS4-30932 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Till, Carola T1 - Interlaboratory study with Tenax thermal desorption - Phase 1 - liquid samples added onto tenax tubes T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - ISO 16000-6 KW - Interlaboratory study KW - VOC KW - External quality management system PY - 2009 IS - Paper 355 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-19923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Danielak, M. A1 - Müller, B. A1 - Jann, Oliver A1 - Plehn, W. A1 - Müller, D. T1 - Implentation of odour test methods into labelling procedures of flooring materials T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - AgBB-Scheme KW - Labelling KW - Flooring material KW - VOC emission KW - Odour PY - 2009 IS - Paper 356 SP - 1 EP - 3 CY - Syracuse, NY, USA AN - OPUS4-19926 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brödner, Doris A1 - Till, Carola T1 - Application of a new gas mixing device to test adsorptive wall materials N2 - With a gas mixing system (GMS) developed in our laboratory we created a gas mixture of four substances. Adsorptive wall materials of four different compositions were exposed to this gas mixture, consisting of 1-pentanol, hexanal, butyl acetate and n-decane. Aim of this study was to scrutinize the ability of these samples to reduce the concentration of the supplied gas. This capacity is expressed in the sorption flux F or area specific adsorption rate respectively. The test was performed referring to a draft of ISO 16000-24. T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Gas mixing device KW - Adsorptive wall material KW - Sorption flux PY - 2009 IS - Paper 259 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20126 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Till, Carola A1 - Kirchner, D. T1 - European interlaboratory study for sampling VOC emissions - Step 3 - Emission test chamber measurements T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - VOC emission KW - Emission test chamber KW - Round robin test KW - Construction products KW - Tenax thermal desorption PY - 2009 IS - Paper 343 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20093 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Pyza, Lars T1 - Development and validation of a new gas mixing device for low concentrations N2 - In our laboratory we developed a gas mixing system (GMS) that is capable of producing stable VOC gas mixtures with concentrations of 1-1000 µg m-3. The single gases are produced by evaporating the pure and liquid substances. T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Gas mixing device KW - Low VOC concentrations KW - Gas atmosphere PY - 2009 IS - Paper 263 SP - 1 EP - 2 CY - Syracuse, NY, USA AN - OPUS4-20124 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Nohr, Michael A1 - Farke, M. A1 - Horn, Wolfgang A1 - Kalus, Sabine A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Frische Luft für Museumsvitrinen - Neue Methode zur Untersuchung von Vitrinenbaumaterialien als Beitrag zur Präventiven Konservierung N2 - Nicht nur Schadstoffe aus der Umwelt können Museumsexponate schädigen. Auch interne Schadstoffquellen wie objektimmanente Exhalate und Emissionen von Lösemitteln oder organischen Säuren können den wertvollen Gu¨tern Schaden zufu¨gen. Auf Schadstoffe zu pru¨fen sowie geeignete Messmethoden zu entwickeln und zu optimieren, ist daher von großer Bedeutung. Neuste Forschungen stellen die Autoren vor. KW - VOC KW - Präventive Konservierung KW - Emissionsmessungen KW - AgBB-Schema KW - Ausstellungsvitrinen KW - Verpackungsmaterialien PY - 2011 SN - 0933-4017 VL - 117 IS - 5 SP - 30 EP - 35 PB - Callwey CY - München AN - OPUS4-23877 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Brödner, Doris A1 - Horn, Wolfgang T1 - Correlation of aldehyde emissions and fatty acids content in pine wood and oriented strand boards N2 - Indoor air quality is important for human health and comfort. To ensure good indoor air quality contamination by volatile organic compounds (VOC) should be minimised. The aim of the project is the reduction of unsaturated aldehydes which can emit from oriented Strand boards (OSB): These aldehydes have an impact on the health based evaluation of emissions from products for indoor use according to the AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products) scheine (AgBB 2010). The model OSB were produced in a pilot plant using well known raw materials (Pinus sylvestris at different trunk heights) under using various processing parameters (Wilke et al. 2011). OSB emit predominantly monoterpenes and aldehydes. Aldehydes are oxidation products of fatty acids in wood. The conditions which affect the oxidation process are the fatty acid concentration and composition, the oxygen content, the sample surface and the presence of compounds which indicate, inhibit or stop the oxidation respectively. The oxidation rate rises with an increasing number of double bounds in the fatty acid, e.g. the oxidation rate between oleic, linoleic and linolenic acid correspond to 1:12:24. One of the most important products of fatty acid oxidation is hexanal. It is generated during the oxidation of linoleic acid. This study shows a direct correlation between aldehyde emission and oxidation, hexanal can be used as an indicator for oxidation. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOCs KW - Oxidation products KW - Fatty acid KW - Saturated and unsaturated aldehyde KW - Hexanal PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23878 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Panaskova, J. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Plehn, W. T1 - Results of sensory tests and sensory-limit settings for building materials in Germany N2 - Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources. Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Perceived air-quality KW - Odour evaluation KW - Odour labelling KW - Test procedure KW - Standardisation PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Howard-Reed, C. A1 - Liu, Z. A1 - Cox, S. A1 - Little, J. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Persily, A. T1 - Inter-laboratory study approach to validate the performance of a prototype reference material for product emissions testing N2 - Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Test method validation KW - Volatile organic compounds KW - Product certification PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Oppl, R. T1 - European Test Method Validation Approaches T2 - NIST/Virginia Tech Workshop: Reference Material Development for Product Emissions Testing CY - Gaithersburg, MD, USA DA - 2011-04-28 PY - 2011 AN - OPUS4-23913 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Ringversuche zur Überprüfung von Emissionskammermessungen T2 - 16. WaBoLu Innenraumtage CY - Berlin, Germany DA - 2009-05-18 PY - 2009 AN - OPUS4-19510 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Juritsch, Elevtheria T1 - Emissionen flüchtiger organischer Verbindungen aus Bauprodukten T2 - VDI Wissensforum "Schadstoffe in Bauprodukten" CY - Stuttgart, Deutschland DA - 2009-10-21 KW - Emissionen KW - Bauprodukte KW - Emissionsmesskammern KW - VOC KW - SVOC KW - Geruch KW - AgBB PY - 2009 SP - 1 EP - 22 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-20306 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Method-verification and optimisation of the standardised assessment of odour intensity regarding ISO 16000-28 N2 - Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons. In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Odour assessment KW - Perceived odour intensity KW - Reference odour KW - Emission testing KW - Building products PY - 2016 SN - 978-0-9846855-5-4 SP - Paper 568, 1 EP - 6 AN - OPUS4-38373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Geruchsprüfungen nach DIN-ISO 16000-28-Grundlagen und Erprobung für den Blauen Engel T2 - 22. WaBoLu-Innenraumtage - Drucker, Gerüche und mehr ... CY - Berlin, Germany DA - 2015-05-12 PY - 2015 AN - OPUS4-33280 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, B. A1 - Panasková, J. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Scutaru, A.M. A1 - Plehn, W. T1 - Entwicklungen der Bewertungsmethodik von Gerüchen in Innenräumen N2 - Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen. KW - Geruch KW - Innenraum KW - Bauprodukte KW - Bewertung PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 70 EP - 82 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-32403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Aktuelle Ringversuche der BAM zu VOC und Gerüchen N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt. T2 - 26. WaBoLu-Innenraumtage CY - Berlin, Germany DA - 20.05.2019 KW - Geruch KW - Ringversuch KW - Bauprodukte KW - Emission KW - Emissionskammer PY - 2019 AN - OPUS4-49237 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 AN - OPUS4-49327 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - The BEMMA-Scheme helpful for low VOC inside display cases? N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. T2 - Indoor Air Quality in Heritage and Historic Environments CY - Online meeting DA - 12.10.2020 KW - Museum KW - VOC-emission KW - BEMMA KW - Display case PY - 2020 AN - OPUS4-51470 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Messverfahren BEMMA-Schema: Entstehung, Anwendung, Grenzen N2 - Mit dem BEMMA-Verfahren lassen sich flüchtige organische Verbindungen aus modernen Werkstoffen, die in mittel- oder unmittelbarem Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen, untersuchen und bewerten. Das Verfahren wurde im Rahmen eines AIF-Vorhabens und der Untersuchung von über 100 unterschiedlichen Materialien entwickelt. Weiterhin wurden mit den gewonnenen Ergebnissen und einigen zuvor bereits identifizierten Problemstoffen wie Essigsäure, Formaldehyd oder Oxime aus den Vorhabenerkenntnissen Bewertungskriterien erarbeitet. Die Vitrinenbaumaterialien, nicht die Vitrine, werden im Hinblick auf ihre Emissionen bewertet, wobei z. B. Holzwerkstoffe nicht bewertet werden, zumal diese meist mit Formaldehyd ein Emissionsproblem hätten. Der Einsatz von Materialien für Vitrinen, die gemäß BEMMA-Schema getestet wurden und die die Emissionswerte erfüllen, soll die Herstellung möglichst emissionsarmer Vitrinen ermöglichen. Kernstück des BEMMA-Schemas ist die Bewertung aller Messergebnisse gemäß dem im Folgenden dargestellten Untersuchungsablauf: 1. Beladen der µ-Kammer; 2. Probenahme der flüchtigen, kurzkettigen, organischen Säuren (ca. 0,5 bis 1 Stunde nach der Beladung für ca. 20 Stunden, 30 Liter Probenahmevolumen); 3. Probenahme der VOCs mit Tenax® (ca. 10 Minuten, 0,25 Liter Probenahmevolumen); 4. Probenahme Oxime und Piperidin-Derivate† mit Tenax® (ca. 40 Minuten, 1,0 Liter Probenahmevolumen); 5. Probenahme der Aldehyde und Ketone (für ca. 20 Stunden, 30 Liter Probenahmevolumen) Dabei werden 4 Sammlersysteme beladen und anschließend analysiert. Die mit dem BEMMA Schema entwickelten Summenwerte für flüchtige organische Stoffe sind im Wesentlichen vor dem Hintergrund der Emissionsminimierung aufgestellt worden. Es gibt für viele VOC keine eindeutige Wechselwirkung mit den Objekten in der Vitrine, zumal diese auch aus vielen verschiedenen Werkstoffen bestehen können und ein VOC nicht mit all diesen reagieren wird. Grundsätzlich „verdächtig“ sind natürlich alle reaktiven Stoffe, wie z. B. Isocyanate. Diese werden aber aus gut gelagerten oder ausreichend belüfteten Baumaterialien für Vitrinen nicht abgegeben. Anorganische Schadgase können zwar in der Umgebungsluft verstärkt auftreten - sind aber aus Baumaterialien nicht zu erwarten. Daher kann das BEMMA-Schema auch nur für einen Teil der luftgetragenen Schadstoffe eine sinnvolle Aussage treffen. Eines der Probleme bei der Bewertung vieler Kleb-/Dichtstoffe ist die Emission cyclischer Siloxane. Deren Schädigungspotential einzu¬schätzen wäre eine wichtige Aufgabe, um an dieser Stelle mehr Klarheit bei der Bewertung zu bekommen. T2 - Quo vadis BEMMA? Präventive Konservierung CY - BAM, Berlin, Germany DA - 07.09.2017 KW - Vitrinen KW - BEMMA KW - VOC KW - Emissionen PY - 2017 AN - OPUS4-43090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Ringversuche zur Bewertung von Geruch bei Bauprodukten N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Diese Methode an sich weist zahlreiche Faktoren auf, die das Untersuchungsergebnis beeinflussen können, als da wären die Konstanz der Parameter wie Luftwechselrate, Luftfeuchtigkeit und Temperatur oder die konkrete Präparation der Probe und deren Positionierung in der Kammer etc. Für die Probenahme von flüchtigen organischen Komponenten kommen noch die eher analytischen Faktoren dazu und für die geruchliche Bewertung lassen sich weitere Einflussgrößen identifizieren. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die ersten beiden dieser Ringversuche wurden mit hohem zeitlichen und personellen Aufwand begleitet. So fuhren in 2012 Mitarbeiter der BAM zu den Teilnehmern und begutachteten vor Ort die jeweils vorhandenen Bewertungs-einrichtungen. In 2014 und 2016 wurden jeweils Materialien verschickt, die sowohl eine geruchliche Bewertung als auch für die Bestimmung von VOC in der Prüfkammerluft geeignet waren. Parallel zu den Proben wurden eine sehr konkrete Anweisung verschickt, wie der Ringversuch durchzuführen war und weiterhin sehr ausführliche Fragebögen, deren Ergebnisse z. T. in die Neufassung der ISO-Norm einfließen sollen. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. T2 - Emissionsarme Bauprodukte und Wohngesundheit CY - Braunschweig, Germany DA - 22.03.2017 KW - Ringversuch KW - Emissionskammer KW - Referenzmaterial KW - Geruch PY - 2017 AN - OPUS4-40298 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Sauerwald, T. A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Schultealbert, C. T1 - Development of a reproducibly emitting reference material for volatile organic compounds N2 - The aim of this study is the development of a reproducibly emitting reference material for volatile organic compounds (VOC). The first part of the work was carried out with styrene, for which supporting materials were successfully selected, doped and analyzed in test chambers. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Quality control KW - Emission test chamber KW - Indoor air KW - Quality assurance PY - 2016 SN - 978-0-9846855-5-4 AN - OPUS4-36849 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Lima Vasconcelos, S. A1 - Sattler, M. A1 - Müller, B. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The Influence of textile floor coverings on the indoor air quality N2 - Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge). T2 - Clima 2019 Congress CY - Bucharest, Romania DA - 26.05.2019 KW - VOC Emissionen KW - Geruch KW - Bodenbelag KW - AgBB Bewertung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487341 DO - https://doi.org/10.1051/e3sconf/201911102051 SN - 2267-1242 VL - 111 SP - 02051-1 EP - 02051-6 PB - EDP Sciences AN - OPUS4-48734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 245 EP - 249 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49326 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Hahn, Oliver T1 - Neues BAM-Zertifizierungsverfahren für emissionsarme Materialien zum Bau von Museumsvitrinen N2 - Museumsvitrinen sollen Kunst- und Kulturgut „ins rechte Licht“ setzen und vor Diebstahl oder Vandalismus schützen. Vergleicht man historische Schauvitrinen, die zumeist aus einfachen Glasscheiben in Holzrahmungen bestehen, mit heutigen Konstruktionen, lässt sich eine Entwicklung zu hochtechnisierten Gebilden ablesen, die deutlich mehr Ansprüchen genügen müssen als in der Vergangenheit. Zahlreiche Beispiele verdeutlichen, dass Kunstwerke nicht nur außerhalb, sondern auch innerhalb von Museen oder Archiven ungünstigen Umwelteinflüssen ausgesetzt sind. So können Einbauten bzw. Dekorationen in Ausstellungsräumen, Aufbewahrungsbehältnisse in Depoträumen oder Ausstellungsvitrinen flüchtige Substanzen, sogenannte VOCs (Volatile Organic Compounds) freisetzen, die zu irreversiblen Veränderungen an den Objekten führen und diese schädigen. Hierzu zählen organische Säuren, wie Ameisen- oder Essigsäure, aber auch Verbindungen, die Sulfide enthalten. Hier wird die an der BAM entwickelte BEMMA-Bewertungsmethode vorgestellt, die von Museen verwendet werden kann Materialien mit einem geringeren Emissionspotential auszusuchen. KW - Museum KW - VOC-emission KW - BEMMA KW - Vitrine PY - 2020 SN - 2194-3648 VL - 2020 IS - zwei SP - 80 EP - 81 PB - SchmittART CY - Leipzig AN - OPUS4-51489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests N2 - In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system. Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received. Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better. T2 - International Conference on Risk Assessment of Indoor Air Chemicals CY - Berlin, Germany DA - 16.09.2018 KW - Chamber test KW - Round robin test KW - VOC-emission PY - 2018 AN - OPUS4-47906 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Selection of low emittiong material for the construction of display cases based on the BEMMA procedure N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. T2 - Materials Testing Symposium CY - New York City, USA DA - 06.11.2019 KW - Museum KW - Emission KW - Dispay case KW - BEMMA KW - VOC PY - 2019 AN - OPUS4-49589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Müller, B. A1 - de Lima Vasconcelos, S. A1 - Plehn, W. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Sattler, M. T1 - Präzisierung der Geruchsprüfung für Bauprodukte nach DIN ISO 16000-28 – Untersuchung von Vergleichsmaßstäben N2 - Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Geruch KW - Emission KW - Bauprodukte KW - VOC KW - Emissionskammer PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 214 EP - 223 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Brozowski, Frank A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte (Teil II): Anwendung eines Adapters und vereinfachtes Bewertungsverfahren T1 - Further Development of the Odour Measurement Method for Building Products (Part II) N2 - Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt. Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes. N2 - For technical improvement of sample presentation an adapter was developed to connect the emission test chamber with the evaluation funnel and thus enabling a more direct measurement. The analytical measurements demonstrate that the air has a very similar composition sampled at the funnel or in the emission test chamber. The results of the olfactory measurements show overall that the intensities determined using the adapter are often reported as lower. Further investigations have shown that air backflow via the funnel into the sample container of the adapter may be the cause. This has to be avoided in future. Another experimental series was carried out to reduce the measurement effort of evaluation of perceived intensity. Here application of the developed ‘greater than, or less than/equal to’ survey could be helpful. The results of the measurements in the air quality lab and in the frame of a round robin test indicate, that the survey leads to the same evaluation as the more complex determination of perceived intensity with standard method. KW - Geruchsmessung KW - VOC-Emission KW - Bauprodukte KW - Bewertungsverfahren PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549875 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 82 IS - 3-4 SP - 83 EP - 89 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-54987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Further Development of Odour Testing of Building Products – Sample Presentation and Evaluation of Perceived Intensity N2 - Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020. In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results. T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 CY - Online meeting DA - 21.06.2021 KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC KW - Perceived Intensity PY - 2021 SN - 978-82-536-1728-2 VL - 2021 SP - 1 EP - 4 PB - SINTEF Books CY - Oslo, Norwegen AN - OPUS4-54574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Panaskova, J. A1 - Müller, D. A1 - Plehn, W. T1 - Sensory tests for building materials and rooms - Status of the standardisation T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - sensory evaluation of building materials and rooms KW - Perceived air quality KW - Standardisation KW - Label KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 6 (3E.5) AN - OPUS4-27561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Wiegner, Katharina A1 - Horn, Wolfgang T1 - Comparison of different air sampling adsorbents for a screening method for SVOC T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Biocides KW - Air sampling KW - Micro-chamber KW - SDVB-polymer PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (6B.2) AN - OPUS4-27569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Jann, Oliver A1 - Hahn, Oliver A1 - Farke, M. T1 - Assessment of Emissions from Materials for Museum Equipment T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26229 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Nohr, Michael A1 - Richter, M. T1 - Development of a reference for the measurement of S(VOC) in Emission test chambers T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27494 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Nohr, Michael A1 - Richter, Matthias T1 - Generation of reproducible chamber concentrations for round robin tests based on reference materials T2 - Emission and Odours from Materials - 2013 CY - Brussels, Belgium DA - 2013-10-17 PY - 2013 AN - OPUS4-29629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Ringversuche zur Einführung von Geruchsmessungen in die Bewertung von Bauprodukten entsprechend der DIN ISO 16000-28 und VDI 4302-1 N2 - The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable. To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014. The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results. T2 - 17. Workshop - Geruch und Emissionen bei Kunststoffen CY - Kassel, Germany DA - 16.03.2015 PY - 2015 SP - 8-1 EP - 8-9 AN - OPUS4-33075 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung der Geruchsmessungen nach DIN ISO 16000-28 in die Bewertung von Bauprodukten N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessung KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukt PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/ringversuch-zur-einfuehrung-der-geruchsmessungen SN - 1862-4804 VL - 88/2014 SP - UBA-FB 002049, EP - 1-141 CY - Dessau-Roßlau AN - OPUS4-34885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung von Geruchsmessungen in Anlehnung an ISO 16000-28 N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessungen KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukte PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 84 EP - 90 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-31391 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Round Robin test for the implementation of odour measurements regarding ISO 16000-28 into the evaluation of buildings products - Part II (Specified by VDI 4302-1) N2 - While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons. KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/round-robin-test-for-the-implementation-of-odour SN - 1862-4804 VL - 79/2015 SP - UBA-FB 002199/E, 1-142 CY - Dessau-Roßlau AN - OPUS4-34886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Mölders, N. A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Mull, B. T1 - Two new promising approaches for quality assurance measures for materials emissions testing N2 - Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained. T2 - Indoor Air 2018 CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Emission reference material KW - Volatile organic compounds KW - CO2 assisted impregnation KW - FEM model PY - 2018 SP - 1 EP - 8 AN - OPUS4-45610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - BEMMA als Auswahlkriterium für Vitrinenbaumaterialien N2 - BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Ergebnisse der Untersuchungen seit ca. 2010 bis 2017 werden präsentiert und diskutiert. T2 - Ringvorlesung der HTW Analyse und Wahrnehmung: Kulturgut erforschen und erhalten CY - HTW Berlin, Germany DA - 16.01.2018 KW - Museumsvitrine KW - VOC-Emissionen KW - BEMMA Bewertung PY - 2018 AN - OPUS4-43828 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Zertifizierung emissionarmer Materialien für Museumsvitrinen N2 - Anregungen aus dem N.i.Ke.-Workshop 2017 und künftige Anforderungen. BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Hier wird der Status-Quo des Erreichten dargestellt. Wie wird das Schema in der Museumsöffentlichkeit wahrgenommen und seine Akzeptanz. T2 - BZS-Beirat CY - BAM, Berlin, Germany DA - 19.01.2018 KW - BEMMA KW - Museumsvitrinen KW - VOC-Emissionen PY - 2018 AN - OPUS4-43860 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Possible reference materials for proficiency tests for emission chamber tests N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Schultealbart, Caroline T1 - Reference materials for round robin tests for emission test chambers – a review N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Metrologie for indoor air quality CY - Berlin, Germany DA - 29.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Evaluation of material emissions for museum equipment – BEMMA-Scheme N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. The basic evaluation for the values used for first assessments were a ZIM-project with nearly 100 tested materials. In-between more than 100 new materials were tested and enlarged the knowledge about material emissions from display case materials. Mainly silicone sealing materials were tested due to the fact that this group of material have the highest emissions. With regard to the testing procedure only construction materials were evaluated, not the display cases their self. Nevertheless in combination with the certificate also designed by BAM additionally the further steps of construction can be taken into account. So other factors such as age and storage time of materials, tightness respectively air change rate, air condition or ventilation of display cases can be included in the evaluation. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Display cases KW - BEMMA KW - Museum KW - Emission KW - VOC PY - 2017 AN - OPUS4-41937 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, Birte A1 - Richter, Matthias A1 - Brödner, Doris T1 - Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers T1 - Entwicklung von Referenzmaterialien für Leistungstests bei Emissionskammermessungen N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT. Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions. The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber. Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results. N2 - Die Untersuchung von Produkten auf deren Emissionseigenschaften ist ein aktuell wachsender Aufgabenbereich für Messinstitute. Label werden für Bauprodukte auf Basis von Emissionskammermessungen vergeben, weshalb die dabei eingesetzten Messmethoden überprüft werden sollten. Ein Ringversuch (RV), bei dem ein homogenes Material von verschiedenen Laboratorien parallel untersucht wird, ist ein geeignetes Verfahren dafür. Für einen solchen Ringversuch aber auch generell für die laborinterne Qualitätssicherung ist es sehr hilfreich ein Referenzmaterial zu haben, um gut vergleichbare Ergebnisse zu erhalten. Generell kann jedes kommerziell erhältliche Produkt als Referenzmaterial verwendet werden, wenn es gut charakterisiert ist. Allerdings emittieren die meisten Produkte nur wenige VOC und diese sind typischerweise sehr materialspezifisch. Die Homogenität der Materialien ist nicht immer gegeben, so ist es besser, nach alternativen Materialien zu suchen. Es sind schon einige Veröffentlichungen zu reproduzierbar emittierenden Materialien verfügbar. Diese enthalten bislang zumeist nur ein einzelnes VOC – Toluol. Im Rahmen von zwei Forschungsvorhaben arbeitet die BAM an der Entwicklung von Referenzmaterialien für Emissionskammer-Untersuchungen, die einzelne VOC oder VOC-Mischungen emittieren. Der erste Ansatz war die Dotierung eines kommerziellen Lackes mit einer VOC/SVOC-Mischung, weitere Untersuchungen werden mit Thermo¬plastischem Polyurethan (TPU) sowie einer Squalan/Paraffin-Mischung durchgeführt. Da mit dem zweiten Ansatz noch Tests laufen, ist damit noch kein RV durchgeführt worden. Wichtige Anforderungen an ein Referenzmaterial sind die Wiederholbarkeit (Homogenität), Reprodu-zierbarkeit und Langzeitstabilität in Bezug auf die VOC-Abgabe und die Transportstabilität. Die Emissionsraten sollten hoch genug sein, um gut messbare Kammerluft-Konzentrationen bei Standardbedingungen zu erhalten. In einen wasserbasierten Lack wurde eine VOC/SVOC-Mischung zugegeben und nach der Durchmischung wurden davon einzelne Portionen in Petrischalen abgefüllt. Diese Schalen wurden unter Standardbedingungen (23 °C und 50% relative Luftfeuchtigkeit) getrocknet. Reproduzierbare Emissionen wurden erhalten, wenn die Lagerzeit ca. vier Wochen nicht überschritten wurde. Die Konzentrationen wurden sieben Tage nach der Beladung der Kammer bestimmt. Zwei RV wurden mit einem wie oben beschriebenen Lacksystem durchgeführt. Es nahmen ca. 50 Labore teil, diese mussten die Zielsubstanzen sowohl identifizieren als auch quantifizieren. Die gefundenen Mittelwerte und Standardabweichungen lagen jeweils im zu erwartenden Bereich für solch einen RV. T2 - Odour and Emission of Plastic Materials CY - Kassel, Germany DA - 21.03.2017 KW - Ringversuch KW - Round robin test KW - Emissionskammer KW - Emission test chamber KW - Referenzmaterial KW - Reference material PY - 2017 AN - OPUS4-40299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, B. A1 - Richter, Matthias A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol). T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Emissions testing KW - Volatile organic compounds KW - Polymeric material KW - CO2 assisted impregnation PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0172, 1 EP - 2 AN - OPUS4-42348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Development of gas standards to underpin indoor air measurements N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Webinar “Discussing impact on climate monitoring and indoor air quality measurements For registration press@inrim.it of EMRP KEYVOCs PROJECT” CY - www; webinar DA - 05.09.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -