TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Ringversuche zur Einführung von Geruchsmessungen in die Bewertung von Bauprodukten entsprechend der DIN ISO 16000-28 und VDI 4302-1 N2 - The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable. To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014. The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results. T2 - 17. Workshop - Geruch und Emissionen bei Kunststoffen CY - Kassel, Germany DA - 16.03.2015 PY - 2015 SP - 8-1 EP - 8-9 AN - OPUS4-33075 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang T1 - Ringversuche zur Überprüfung von Emissionskammermessungen T2 - 16. WaBoLu Innenraumtage CY - Berlin, Germany DA - 2009-05-18 PY - 2009 AN - OPUS4-19510 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Round Robin test for the implementation of odour measurements regarding ISO 16000-28 into the evaluation of buildings products - Part II (Specified by VDI 4302-1) N2 - While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons. KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/round-robin-test-for-the-implementation-of-odour SN - 1862-4804 VL - 79/2015 SP - UBA-FB 002199/E, 1-142 CY - Dessau-Roßlau AN - OPUS4-34886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias T1 - Round robin tests of odour and VOC emissions from building products – What have we learned so far? N2 - Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Perceived intensity KW - VOC-emission KW - Poficiency test KW - Chamber test KW - Odour PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580001 SP - 434 EP - 436 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver ED - Brozio, P. T1 - Schadstoffe im Museum richtig einschätzen N2 - Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen. KW - Emissionsarme Vitrinen KW - Präventive Konservierung KW - VOC KW - BEMMA PY - 2011 SN - 978-3-7667-1962-1 SP - 127 EP - 131 PB - Callwey CY - München AN - OPUS4-25377 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Selection of low emittiong material for the construction of display cases based on the BEMMA procedure N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. T2 - Materials Testing Symposium CY - New York City, USA DA - 06.11.2019 KW - Museum KW - Emission KW - Dispay case KW - BEMMA KW - VOC PY - 2019 AN - OPUS4-49589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensorische Bewertung der Emissionen aus Bauprodukten - Integration in die Vergabegrundlagen für den Blauen Engel und das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissionen aus Bauprodukten beeinträchtigen die Qualität der Innenraumluft erheblich. Mit Hilfe des AgBB-Schemas werden die Emissionen flüchtiger organischer Verbindungen (VOC) aus Bauprodukten bewertet. Die gesundheitliche Bewertung nach dem AgBB-Schema erfordert produktspezifische Messverfahren. Diese gibt es mittlerweile für eine Reihe von Produkten. Sie wurden durch Beteiligung verschiedener Forschungseinrichtungen und Messinstitute validiert und u. a. in die Vergabekriterien des Umweltzeichens Blauer Engel übernommen. Die Bewertung ist allerdings –mit zumeist niedrigeren Grenzwerten –strenger. VOC-Emissionen und Gerüche können beide zu gesundheitlichen Belastungen führen. So ist die sensorische Prüfung ein weiteres wichtiges Element bei der Bewertung von Bauprodukten und vorsorglich auch im AgBB-Schema verankert. Hauptziel des Projektes ist es, eine Methode der sensorischen Bewertung und Grenzen für die Vergabe des Blauen Engels und für das AgBB-Schema abzuleiten. Auf Grundlage der durchgeführten Untersuchungen (siehe Kapitel 5 Ergebnisse und Diskussion) wird als Bewertungsmethode die empfundene Intensität und die Hedonik vorgeschlagen. Die Ableitung der Grenzwerte für die sensorische Bewertung am 28. Tag erfolgt über die zusätzliche Befragung der Probanden im Rahmen der vorliegenden Studie nach der Zumutbarkeit einer Probe. Für den Blauen Engel könnte es je Produktgruppe unterschiedliche Grenzen der empfundenen Intensität und der Hedonik geben. Ein erster Vorschlag für mögliche Grenzen, hier zunächst einheitlich für alle Produktgruppen, ist für die empfundene Intensität 7 pi (5 pi + 2 pi als Sicherheit, Kapitel 5.1.5) und für die Hedonik -1 (0 +/-0,8, gerundet auf -1) (siehe dazu Abbildung 6-2). KW - Bauprodukt KW - Schadstoff KW - Prüfverfahren KW - Blauer Engel KW - SVOC KW - Flüchtige Emission KW - Kohlenwasserstoff KW - Geruch KW - Sensorik KW - AgBB-Schema PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensorische-bewertung-emissionen-aus-bauprodukten SN - 1862-4804 IS - 35 SP - 1-146, Anhang 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-24926 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Sensorische Bewertung der Emissionen aus Bauprodukten Vorgehensweise / Chemisch analytische Messungen T2 - 17. WaBoLu Innenraumtage CY - Berlin, Germany DA - 2010-05-10 PY - 2010 AN - OPUS4-21330 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Sensorische Bewertung von Bauprodukten - Ergebnisse VOC T2 - Abschlussveranstaltung "Sensorische Bewertung von Bauprodukten" CY - Berlin, Germany DA - 2010-03-08 PY - 2010 AN - OPUS4-21021 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kasche, J. A1 - Dahms, A. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory evaluation of building products - Results of a German round robin test T2 - VDI-Tagung CY - Bad Kissingen, Deutschland DA - 2007-11-13 KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Blauer Engel PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 193 EP - 202 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Panaskova, J. A1 - Müller, D. A1 - Plehn, W. T1 - Sensory tests for building materials and rooms - Status of the standardisation T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - sensory evaluation of building materials and rooms KW - Perceived air quality KW - Standardisation KW - Label KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 6 (3E.5) AN - OPUS4-27561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Sensory tests for buildings materials and rooms -Status of the standardisation- T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27493 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Wilke, Olaf T1 - Suitability of small environmental chambers to test the emission of biocides from treated materials into the air N2 - Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100–200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole. KW - Indoor air KW - Biocides KW - Emission test chamber KW - SVOC PY - 2003 DO - https://doi.org/10.1016/j.atmosenv.2003.09.024 SN - 0004-6981 SN - 1352-2310 VL - 37 IS - 39-40 SP - 5477 EP - 5483 PB - Elsevier CY - Amsterdam AN - OPUS4-2676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - The BEMMA-Scheme helpful for low VOC inside display cases? N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. T2 - Indoor Air Quality in Heritage and Historic Environments CY - Online meeting DA - 12.10.2020 KW - Museum KW - VOC-emission KW - BEMMA KW - Display case PY - 2020 AN - OPUS4-51470 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The blue angel - VOC workshop T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - AgBB-Scheme KW - Labeling KW - VOC emission PY - 2009 IS - Paper 427 SP - 1 EP - 3 CY - Syracuse, NY, USA AN - OPUS4-19924 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Lima Vasconcelos, S. A1 - Sattler, M. A1 - Müller, B. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The Influence of textile floor coverings on the indoor air quality N2 - Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge). T2 - Clima 2019 Congress CY - Bucharest, Romania DA - 26.05.2019 KW - VOC Emissionen KW - Geruch KW - Bodenbelag KW - AgBB Bewertung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487341 DO - https://doi.org/10.1051/e3sconf/201911102051 SN - 2267-1242 VL - 111 SP - 02051-1 EP - 02051-6 PB - EDP Sciences AN - OPUS4-48734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, B. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - The use of gas sampling bags for evaluating the odours of building materials T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Bauprodukte KW - Emissionen KW - Geruch KW - Probenahmebehälter PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 2030 EP - 2034 PB - Tsinghua University Press CY - Beijing AN - OPUS4-11073 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Mölders, N. A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Mull, B. T1 - Two new promising approaches for quality assurance measures for materials emissions testing N2 - Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained. T2 - Indoor Air 2018 CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Emission reference material KW - Volatile organic compounds KW - CO2 assisted impregnation KW - FEM model PY - 2018 SP - 1 EP - 8 AN - OPUS4-45610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, Johannes A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Umwelt- und Gesundheitsanforderungen an Bauprodukte - Ermittlung und Bewertung der VOC-Emissionen und geruchlichen Belastungen (Forschungsbericht 20262320) KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Laborvergleich PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/umwelt-gesundheitsanforderungen-an-bauprodukte SN - 1862-4804 IS - 16 SP - 383 Seiten PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-14791 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -