TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Kalus, Sabine T1 - Classification of OSB emissions assessed with a German evaluation scheme T2 - 8th international Conference on Healthy Buildings 2006 CY - Lisbon, Portugal DA - 2006-06-04 PY - 2006 AN - OPUS4-13232 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Using the AgBB evaluation scheme for VOC and odour emissions of different construction products T2 - Emissions and odours from materials CY - Brussels, Belgium DA - 2006-10-11 PY - 2006 AN - OPUS4-13237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - VOC aus Bauprodukten: neue Erkenntnisse T2 - VOC und Gerüche aus Bauprodukten CY - Berlin, Germany DA - 2006-09-21 PY - 2006 AN - OPUS4-13242 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, B. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - The use of gas sampling bags for evaluating the odours of building materials T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Bauprodukte KW - Emissionen KW - Geruch KW - Probenahmebehälter PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 2030 EP - 2034 PB - Tsinghua University Press CY - Beijing AN - OPUS4-11073 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Kasche, J. A1 - Jann, Oliver A1 - Müller, D. T1 - Emissions- und Geruchsuntersuchungen an Bauprodukten - Ergebnisse eines UFO-Planprojektes T2 - 8th Workshop "Odour and Emissions of Plastic Materials" CY - Kassel, Germany DA - 2006-03-27 KW - Bauprodukte KW - Emissionen KW - Geruch KW - RAL UZ PY - 2006 SP - 13-1- 13-7 CY - Kassel AN - OPUS4-12259 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Metodik zur Erfassung von Gerüchen und Emissionen aus Bauprodukten und Holzwerkstoffen T2 - 1. Fachtagung Holztechnologie CY - Darmstadt, Germany DA - 2006-11-07 PY - 2006 AN - OPUS4-13768 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Development of a Test Method for and Investigation into Limiting the Emissions from Printers and Copiers within the Framework of Assigning the Environmental Label (Research Report 201 95 311/02 / UBA-FB 00,510E) N2 - Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices. KW - Emissions KW - VOC KW - Ozone KW - Dust KW - Hardcopy device KW - Printers KW - Copiers KW - Emission test chamber KW - Environmental label PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/development-of-a-test-method-for-an-investigation SN - 1862-4804 SN - 0722-186X IS - 88 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Schoknecht, Ute T1 - Biozidemissionen aus behandelten Materialien T2 - BAM-Kolloquium CY - Berlin, Germany DA - 2002-03-06 PY - 2002 AN - OPUS4-5998 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Brosig, Laura T1 - Evaluation of the Odour of Construction Products According to ISO 16000-28 - a first Laboratory Comparison Test T2 - Odour and Emissions of Plastic Materials CY - Kassel, Germany DA - 2013-03-18 PY - 2013 AN - OPUS4-28201 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, Birgit A1 - Müller, D. A1 - Horn, Wolfgang A1 - Panasková, J. A1 - Plehn, W. T1 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum T1 - Measurement and evaluation of odour emissions from building products for indoor usage N2 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum gewinnen vor allem durch den zunehmenden Bau energieeffizienter Gebäude an Bedeutung. Intensive und unangenehme Gerüche werden von Bewohnerinnen, Bewohnern und Angestellten nicht akzeptiert und können auf Dauer krank machen. Bislang stand noch kein allgemein anerkanntes Messverfahren zur Verfügung. Dieses wurde nun in Forschungsprojekten entwickelt, wobei auch konkrete Bewertungsvorschläge zur Zumutbarkeit von Gerüchen gemacht wurden. Das Verfahren ist an die Messung der Emissionen flüchtiger organischer Verbindungen aus Bauprodukten gekoppelt und nutzt Probanden, um die Geruchsstärke (Intensität) und den Geruchseindruck (Hedonik) zu ermitteln. In der Praxis wird das Verfahren nun an verschiedenen Stellen erprobt. Die Bewertung der Geruchsemissionen gibt der Industrie die Möglichkeit, geruchsarme Produkte zu gestalten. Die Kennzeichnung geruchsarmer Bauprodukte mit dem Umweltzeichen Blauer Engel erleichtert Verbraucherinnen und Verbrauchern die Orientierung beim Einkauf. N2 - Measuring and evaluating odour emissions from building products used in indoor spaces are becoming increasingly important for the construction of energy-efficient buildings. Intensive and unpleasant smells are not accepted by inhabitants and employees and may lead to negative health effects. Up to now a consistent measuring method for odour emissions has not been available. A measuring method and also concrete standards for the assessment of odours by using reasonableness of smells have now been developed in succeeding research projects. The procedure uses a panel of test persons to determine the strength (intensity) and impression (hedonic appraisal) of odour and is linked to the already well established measurement of the emission of volatile organic compounds from building products. At the Moment the new procedure is tested in practice at different laboratories. Evaluating odour emissions helps manufacturers to develop products with low or very low odour emissions. The labeling of low-odour Building products with the environmental label Blue Angel gives consumers an orientation for purchase. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen PY - 2011 SN - 2190-1120 SN - 2190-1147 VL - 4 SP - 50 EP - 58 PB - BfS CY - Berlin AN - OPUS4-25210 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, B. A1 - Panaskova, J. A1 - Müller, D. A1 - Plehn, W. T1 - Sensory tests for buildings materials and rooms -Status of the standardisation- T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27493 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nohr, Michael A1 - Wiegner, Katharina A1 - Richter, Matthias A1 - Horn, Wolfgang T1 - Development of a reference material for the measurement of (S)VOC in emission test chambers T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - VOC KW - Sources/emissions KW - Measurements KW - Laboratory studies PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5B.10) AN - OPUS4-27568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion (UFOPLAN 370895301) KW - Bürogeräte mit Laserdruckfunktion KW - Feine und ultrafeine Partikel KW - Chemische Emissionen KW - Blauer Engel PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/erfassung-zahl-feiner-ultrafeiner-partikel-aus SN - 1862-4804 SN - 0722-186X IS - 74 SP - 1 EP - 189 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-27523 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Farke, M. A1 - Hahn, Oliver T1 - Assessment of emissions from materials for museum equipment T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Assessment of emissions from materials for museum equipment KW - BEMMA display case KW - Protection of cultural object KW - Emissions PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (7G.3) AN - OPUS4-27525 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 2012-07-08 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different Possibilities for the Statistical Evaluation of Round Robin Tests for Volatile Organic Compounds in Emission Test Chambers T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26230 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, J. A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Environmental and Health Provisions for Building Products - Identification and evaluation of VOC emissions and odour exposure (Research Report 202 62 320 / UBA-FB 001002) N2 - In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation. KW - Building products KW - Emissions KW - Odour KW - AgBB-Scheme KW - Chamber tests KW - Interlaboratory study KW - Construction products KW - Emission test chamber KW - Odour evaluation KW - VOC KW - VVOC KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Gas sensor KW - Acrylic and silicone sealant KW - Wood-based product KW - Paints KW - Lacquers KW - Interlaboratory comparison PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/environmental-health-provisions-for-building SN - 1862-4804 SN - 0722-186X IS - 21 SP - 1 EP - 381 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-15931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Kemmlein, Sabine A1 - Till, Carola A1 - Kirchner, D. A1 - Jann, Oliver T1 - European interlaboratory study for sampling VOC emissions - Step 1 - liquid samples added on Tenax tubes T2 - Conference Indoor Air 2008 CY - Copenhagen, Denmark DA - 2008-08-17 PY - 2008 AN - OPUS4-18044 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Bitter, F. A1 - Wargocki, P. A1 - Olesen, B. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Airaksinen, M. A1 - Järnström, H. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Material labelling: Combined material emission tests and sensory evaluations T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Material labelling KW - Emission test KW - Sensory evaluation KW - Odour intensity KW - Acceptability PY - 2008 IS - Paper 1066 SP - 1 EP - 8 AN - OPUS4-18047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -