TY - GEN A1 - Bartholmai, Matthias A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Homfeld, S.D. A1 - Köppe, Enrico T1 - Funkbasiertes Sensornetzwerk zur Schadensfrüherkennung an Bauwerken KW - Funksensorik KW - Sensornetzwerk KW - Schadensfrüherkennung KW - Strukturüberwachung PY - 2008 SN - 978-3-18-092011-5 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 2011 SP - 587 EP - 592 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-17264 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartholmai, Matthias A1 - Köppe, Enrico A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Homfeld, S.D. T1 - Funkbasiertes Sensornetzwerk zur Schadensfrüherkennung an Bauwerken T2 - Wireless Automation : funkgestützte Kommunikation in der industriellen Automatisierungstechnik ; Tagung Berlin CY - Berlin, Deutschland DA - 2008-02-28 KW - Funksensorik KW - Sensornetzwerk KW - Schadensfrüherkennung KW - Strukturüberwachung PY - 2008 SN - 978-3-18-092010-8 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 2010 SP - 117 EP - 125 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-17137 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mirtschink, P. A1 - Stehr, S.N. A1 - Pietzsch, H.J. A1 - Bergmann, R. A1 - Pietzsch, J. A1 - Wunderlich, G. A1 - Heintz, A.C. A1 - Kropp, J. A1 - Spies, H. A1 - Kraus, Werner A1 - Deussen, A. A1 - Walther, M. T1 - Modified "4+1" Mixed Ligand Technetium-Labeled Fatty Acids for Myocardial Imaging: Evaluation of Myocardial Uptake and Biodistribution N2 - Our group previously synthesized 99mTc-labeled fatty acids suitable for myocardial metabolism and flow imaging. In this set of experiments, 29 new analogues were synthesized according to the “4 + 1” mixed ligand approach with some specific differences. Conventional “4 + 1” 99mTc-fatty acids are built in the sequence: Tc-chelate, alkyl chain, and carboxylic group. We developed compounds following a new design with the sequence: carboxylic group, alkyl chain, Tc-chelate, and lipophilic tail. Therefore, the 99mTc-chelate was transferred to a more central position of the compound, aiming toward an improved myocardial profile and an accelerated liver clearance. In this context, several functional groups incorporated in the lipophilic tail section were tested to evaluate their influence on the compound's character. In addition to biodistribution studies in vivo, the myocardial first-pass extraction of the compounds was tested in an isolated Langendorff rat heart model. A satisfactory myocardial uptake of up to 20% of the injected dose (% ID) in the perfused heart and a fast liver clearance in vivo with only 0.29% ID/g at 60 min postinjection demonstrate that the induced molecular modifications affect the kinetics of 99mTc-radiolabeled fatty acid compounds favorably. From the data set, rules for estimating the biodistribution of fatty acids tracers are deduced. PY - 2008 DO - https://doi.org/10.1021/bc700164c SN - 1043-1802 SN - 1520-4812 VL - 19 IS - 1 SP - 97 EP - 108 CY - Washington, DC AN - OPUS4-16499 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Jakob, Ines A1 - Li, C.S. A1 - Tatzky-Gerth, Renate T1 - Durability of polyolefin geosynthetic drains N2 - The German Federal Institute for Materials Research and Testing (BAM) has established a testing guideline to assess the suitability of geosynthetic or geocomposite drain (GCD) elements for final landfill cover systems. In an earlier paper the uniform procedure according to the BAM guideline for determining long-term water flow capacity was described, and the structural stability of drain cores under creep was investigated. The extrapolation of creep curves is permissible only when it can be shown, over the extrapolated period (at least 100 years), that oxidative aging does not invoke any relevant changes in the polyolefin material. This can be shown by measuring antioxidant depletion and mechanical degradation of the drain cores and filter/protection geotextiles in oven aging and water immersion tests. In this paper the results of such aging studies on three different GCD products are reported. Degradation of the tensile strength of HALS-stabilized polypropylene needle-punched nonwoven geotextiles (PP NWGTs) starts right from the beginning of the oven aging. This has to be taken into account for lifetime predictions based on residual tensile strength. The rate of oxidative degradation of NWGTs decreases significantly with increasing mass per area. Therefore the expected service life sets a limit on acceptable geotextile grammage. Antioxidant depletion in the drain cores, which are made of relatively thick PP strands or HDPE ribs, is about an order of magnitude slower than in filter and protection NWGTs, which are made of thin fibers. Service life values in excess of 100 years may be obtained for the products when the geotextiles and drain cores are properly stabilized and designed. KW - Geosynthetics KW - Geosynthetic drain elements KW - Long-term behavior KW - Oxidative degradation PY - 2009 DO - https://doi.org/10.1680/gein.2009.16.1.28 SN - 1072-6349 VL - 16 IS - 1 SP - 28 EP - 42 PB - Telford CY - London, UK AN - OPUS4-18999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -