TY - JOUR A1 - Wan, Wei A1 - Biyikal, Mustafa A1 - Wagner, R. A1 - Sellergren, B. A1 - Rurack, Knut T1 - Fluorescent sensorymicroparticles that 'light-up' consisting of a silica core and a molecularly imprinted polymer (MIP) shell N2 - From darkness came light: Incorporation of urea-based fluorescent dyes in an anion-imprinted thin polymer shell coated onto silica microparticles leads to a unique and highly enantioselective fluorescent 'light-up' response to analytes (see scheme, MIP molecularly imprinted polymer). KW - Core–shell particles KW - Enantioselectivity KW - Fluorescence KW - Molecularly imprinted polymers KW - Sensors PY - 2013 DO - https://doi.org/10.1002/anie.201300322 SN - 1433-7851 SN - 1521-3773 SN - 0570-0833 VL - 52 IS - 27 SP - 7023 EP - 7027 PB - Wiley-VCH CY - Weinheim AN - OPUS4-28740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wan, Wei A1 - Biyikal, Mustafa A1 - Wagner, R. A1 - Sellergren, B. A1 - Rurack, Knut T1 - Sensorische Mikropartikel aus einem Silicatkern und einem molekular geprägten Polymer als Schale mit aufleuchtender Fluoreszenz N2 - Und es ward Licht – der Einbau eines auf Harnstoff basierenden Fluoreszenzfarbstoffs in eine mit Anionen geprägte dünne Polymerschale (MIP) auf Silicatmikropartikeln führt zu einem spezifischen und enantioselektiven Aufleuchten der Fluoreszenz in Gegenwart des Zielanalyten. KW - Enantioselektivität KW - Fluoreszenz KW - Kern-Schale-Partikel KW - Molekular geprägte Polymere KW - Sensoren PY - 2013 DO - https://doi.org/10.1002/ange.201300322 SN - 0044-8249 SN - 0932-2140 SN - 1521-3757 VL - 125 IS - 27 SP - 7161 EP - 7165 PB - Wiley-VCH CY - Weinheim AN - OPUS4-28739 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wan, Wei A1 - Wagner, Sabine A1 - Rurack, Knut T1 - Fluorescent monomers: "bricks" that make a molecularly imprinted polymer "bright" N2 - Molecularly imprinted polymers (MIPs) are potent and established recognition phases in separation and enrichment applications. Because of their robustness, versatility and format adaptability, they also constitute very promising sensing phases, especially when the active sensing element is directly integrated into the MIP. Fluorescent MIPs incorporating fluorescent monomers are perhaps the best developed and most successful approach here. This article reviews the state of the art in this field, discussing the pros and cons of the use of fluorescent dye and probe derivatives as such monomers, the different molecular interaction forces for template complexation, signalling modes and a variety of related approaches that have been realized over the years, including Förster resonance energy transfer processes, covalent imprinting, postmodification attachment of fluorescent units and conjugated polymers as MIPs; other measurement schemes and sensing chemistries that use MIPs and fluorescence interrogation to solve analytical problems (fluorescent competitive assays, fluorescent analytes, etc.) are not covered here. Throughout the article, photophysical processes are discussed to facilitate understanding of the effects that can occur when one is planning for a fluorescence response to happen in a constrained polymer matrix. The article concludes with a concise assessment of the suitability of the different formats for sensor realization. KW - Chemical sensors KW - Fluorescence KW - Molecularly imprinted polymers KW - Dyes KW - Sol-gel PY - 2016 DO - https://doi.org/10.1007/s00216-015-9174-4 SN - 1618-2642 SN - 1618-2650 VL - 408 IS - 7 SP - 1753 EP - 1771 PB - Springer CY - Berlin AN - OPUS4-35830 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shinde, S. A1 - El-Schich, Z. A1 - Malakpour, A. A1 - Wan, Wei A1 - Dizeyi, N. A1 - Mohammadi, R. A1 - Rurack, Knut A1 - Gjörloff Wingren, A. A1 - Sellergren, B. T1 - Sialic acid-imprinted fluorescent core-shell particles for selective labeling of cell surface glycans N2 - The expression of cell surface glycans terminating with sialic acid (SA) residues has been found to correlate with various disease states there among cancer. We here report a novel strategy for specific fluorescence labeling of such motifs. This is based on sialic acid-imprinted core–shell nanoparticles equipped with nitrobenzoxadiazole (NBD) fluorescent reporter groups allowing environmentally sensitive fluorescence detection at convenient excitation and emission wavelengths. Imprinting was achieved exploiting a hybrid approach combining reversible boronate ester formation between p-vinylphenylboronic acid and SA, the introduction of cationic amine functionalities, and the use of an NBD-appended urea-monomer as a binary hydrogen-bond donor targeting the SA carboxylic acid and OH functionalities. The monomers were grafted from 200 nm RAFT-modified silica core particles using ethylene glycol dimethacrylate (EGDMA) as cross-linker resulting in a shell thickness of ca. 10 nm. The particles displayed strong affinity for SA in methanol/water mixtures (K = 6.6 × 105 M-1 in 2% water, 5.9 × 103 M-1 in 98% water, Bmax ≈ 10 µmol g-1), whereas binding of the competitor glucuronic acid (GA) and other monosaccharides was considerably weaker (K (GA) = 1.8 × 103 M-1 in 98% water). In cell imaging experiments, the particles selectively stained different cell lines in correlation with the SA expression level. This was further verified by enzymatic cleavage of SA and by staining using a FITC labeled SA selective lectin. KW - Glycoproteine KW - Biomarker KW - Fluoreszenz KW - Polymere KW - Krebsdiagnostik PY - 2015 DO - https://doi.org/10.1021/jacs.5b08482 SN - 0002-7863 SN - 1520-5126 VL - 137 IS - 43 SP - 13908 EP - 13912 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-35227 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wagner, Sabine A1 - Zapata, Carlos A1 - Wan, Wei A1 - Gawlitza, Kornelia A1 - Weber, M. A1 - Rurack, Knut T1 - Role of Counterions in Molecularly Imprinted Polymers for Anionic Species N2 - Small-molecule oxoanions are often imprinted noncovalently as carboxylates into molecularly imprinted polymers (MIPs), requiring the use of an organic counterion. Popular species are either pentamethylpiperidine (PMP) as a protonatable cation or tetraalkylammonium (TXA) ions as permanent cations. The present work explores the influence of the TXA as a function of their alkyl chain length, from methyl to octyl, using UV/vis absorption, fluorescence titrations, and HPLC as well as MD simulations. Protected phenylalanines (Z-L/D-Phe) served as templates/analytes. While the influence of the counterion on the complex stability constants and anion-induced spectral changes shows a monotonous trend with increasing alkyl chain length at the prepolymerization stage, the cross-imprinting/rebinding studies showed a unique pattern that suggested the presence of adaptive cavities in the MIP matrix, related to the concept of induced fit of enzyme−substrate interaction. Larger cavities formed in the presence of larger counterions can take up pairs of Z-X-Phe and smaller TXA, eventually escaping spectroscopic detection. Correlation of the experimental data with the MD simulations revealed that counterion mobility, the relative distances between the three partners, and the hydrogen bond lifetimes are more decisive for the response features observed than actual distances between interacting atoms in a complex or the orientation of binding moieties. TBA has been found to yield the highest imprinting factor, also showing a unique dual behavior regarding the interaction with template and fluorescent monomer. Finally, interesting differences between both enantiomers have been observed in both theory and experiment, suggesting true control of enantioselectivity. The contribution concludes with suggestions for translating the findings into actual MIP development. KW - Anion receptors KW - Fluorescence sensing KW - Molecular dynamics simulations KW - Molecularly imprinted polymers KW - Rational design PY - 2018 DO - https://doi.org/10.1021/acs.langmuir.8b00500 SN - 0743-7463 VL - 34 IS - 23 SP - 6963 EP - 6975 PB - American Chemical Society CY - Washington, D.C. AN - OPUS4-45399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Moleculary imprinted polymer as sensory materials for the selective detection of carboxylates via fluorescence enhancement T2 - 7th INTERNATIONAL CONFERENCE on Molecularly Imprinted Polymers - Science and Technology CY - Paris, France DA - 2012-08-27 PY - 2012 AN - OPUS4-26851 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Assessing the FRET Acceptor Potential of Various BODIPY Dyes for Europium as the FRET Donor T2 - International Bunsen Discussion Meeting on Förster Resonance Energy Transfer in Life Sciences CY - Göttingen, Germany DA - 2011-03-27 PY - 2011 AN - OPUS4-23937 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Hydrogen Bonding vs. Deprotonation: Binding of a Chromogenic Functional Monomer towards a Template in Molecular Imprinting Polymerization T2 - Affinity 2011 CY - Tavira, Portugal DA - 2011-06-16 PY - 2011 AN - OPUS4-24007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Molecularly imprinted polymers as sensory materials for the selective detection of carboxylates via fluorescence enhancement T2 - 4th Graduate Student Symposium on Molecular Imprinting CY - London, England DA - 2011-09-28 PY - 2011 AN - OPUS4-24698 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Direct Anion Sensing with Amplified Flourescence Using Moleculary Imprinted Core-Shell Nanoparticles T2 - 8. Deutsches BioSensor Symposium CY - Wildau, Germany DA - 2013-03-10 PY - 2013 AN - OPUS4-27846 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wan, Wei T1 - Flourescent MIP sensors: broadening the scope of molecularly imprinted polymers T2 - ANAKON 2013 CY - Essen, Germany DA - 2013-03-04 PY - 2013 AN - OPUS4-27849 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Costa, Elena A1 - Climent Terol, Estela A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Optimization of analytical assay performance of antibody-gated indicator-releasing mesoporous silica particles N2 - Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities. KW - Antibody-gated indicator delivery KW - Lateral flow assay KW - SBA-15 KW - SBA-16 KW - Type-I pyrethroids KW - Phenothrin KW - Permethrin KW - Etofenprox KW - Amplification KW - Biosensors KW - Immunoassays KW - Mesoporous particles KW - Optical detection PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517053 DO - https://doi.org/10.1039/d0tb00371a VL - 8 IS - 22 SP - 4950 EP - 4961 PB - Royal Society of Chemistry AN - OPUS4-51705 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -