TY - JOUR A1 - Sadowski, A. A1 - Seidel, M. A1 - Al-Lawati, H. A1 - Azizi, E. A1 - Balscheit, Hagen A1 - Böhm, M. A1 - Chen, Lei A1 - van Dijk, I. A1 - Doerich-Stavridis, C. A1 - Kunle Fajuyitan, O. A1 - Filippidis, A. A1 - Winther Fischer, A. A1 - Fischer, C. A1 - Gerasimidis, S. A1 - Karampour, H. A1 - Kathirkamanathan, L. A1 - Subramanian, S. A1 - Topkaya, Cem A1 - Wagner, H. N. R. A1 - Wang, J. A1 - Wang, J. A1 - Kumar Yadav, K. A1 - Yun, X. A1 - Zhang, P. T1 - 8-MW wind turbine tower computational shell buckling benchmark - Part 1: An international ‘round-robin’ exercise N2 - An assessment of the elastic-plastic buckling limit state for multi-strake wind turbine support towers poses a particular challenge for the modern finite element analyst, who must competently navigate numerous modelling choices related to the tug-of-war between meshing and computational cost, the use of solvers that are robust to highly nonlinear behaviour, the potential for multiple near-simultaneously critical failure locations, the complex issue of imperfection sensitivity and finally the interpretation of the data into a safe and economic design. This paper reports on an international ‘round-robin’ exercise conducted in 2022 aiming to take stock of the computational shell buckling expertise around the world which attracted 29 submissions. Participants were asked to perform analyses of increasing complexity on a standardised benchmark of an 8-MW multi-strake steel wind turbine support tower segment, from a linear elastic stress analysis to a linear bifurcation analysis to a geometrically and materially nonlinear buckling analysis with imperfections. The results are a showcase of the significant shell buckling expertise now available in both industry and academia. This paper is the first of a pair. The second paper presents a detailed reference solution to the benchmark, including an illustration of the Eurocode-compliant calibration of two important imperfection forms. KW - Wind turbine tower KW - Computational KW - Shell buckling KW - Benchmark PY - 2023 DO - https://doi.org/10.1016/j.engfailanal.2023.107124 SN - 1350-6307 VL - 148 SP - 1 EP - 23 PB - Elsevier Science CY - Oxford AN - OPUS4-57019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Leschik, M. A1 - Heide, G. A1 - Frischat, G.H. A1 - Behrens, H. A1 - Wiedenbeck, M. A1 - Wagner, N. A1 - Heide, K. A1 - Geißler, Heinz A1 - Reinholz, Uwe T1 - Determination of H2O and D2O contents in rhyolitic glasses N2 - Five distinct analytical techniques were compared for the quantification of the H2O (0·1-7·4 wt%) and D2O (up to 5·5 wt% D2O) contents in rhyolitic glasses. The hydrogen concentration in obsidians was measured using nuclear reaction analysis (NRA) and converted into H2O concentration. The bulk water content (H2O+D2O) of synthesised glasses was determined using thermal extraction in conjunction with Karl–Fischer titration (KFT). Unextracted H2O was measured by infrared (IR) spectroscopy after remelting the KFT products at high pressure. These well characterised glasses were subsequently used to calibrate secondary ion mass spectrometry (SIMS), infrared and evolved gas analysis (EGA). The calibrations of SIMS for H2O and D2O show a significant matrix effect at H2O and D2O concentrations larger than ~3 mol/l with the relative sensitivity factor (RSF) decreasing with bulk water content. Molar absorption coefficients for the OH stretching vibration band at 3570 cm-1 and the OD stretching vibration band at 2650 cm-1 in the infrared absorption spectra were reinvestigated. In the range 0·1-6 wt% the H2O content of glasses could be reproduced within analytical error using a constant linear molar absorption coefficient. However, it appears that the absorption coefficients for the 3570 cm-1 band as well as for the 2650 cm-1 band both decrease systematically with concentration of dissolved H2O and D2O (epsi3570=80 (±1) - 1·36(±0·23)CH2Ot and epsi2650=61·2(±1) - 2·52(± 0·30)CD2Ot). EGA allows quantification of the H2O content as well as the study of dehydration kinetics. It is shown that H2O is released under vacuum already at room temperature from glasses containing >7 wt% H2O. PY - 2004 UR - http://www.ingentaconnect.com/content/sgt/pcg/2004/00000045/00000004/art00003 SN - 0031-9090 VL - 45 IS - 4 SP - 238 EP - 251 PB - Thornton CY - Sheffield AN - OPUS4-6279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Budnik, J. A1 - Betz, T. A1 - Fromm, A. A1 - Gerdes, A. A1 - Gerlach, J. A1 - Götz, M. A1 - Hintzen, W. A1 - Hüttl, R. A1 - Kämpfer, W. A1 - König, A. A1 - Kühner, S. A1 - Lohaus, L. A1 - Meng, Birgit A1 - Neumann, T. A1 - Patzer, M. A1 - Schaab, A. A1 - Schauerte, J. A1 - Siebert, B. A1 - Stephan, D. A1 - Tebbe, H. A1 - Wagner, J.-P. ED - Siebert, B. T1 - Chemischer Angriff auf Betonbauwerke - Bewertung des Angriffsgrads und geeignete Schutzprinzipien N2 - In verschiedenen Bereichen des Betonbaus ist Beton einem chemischen Angriff von außen ausgesetzt, der die Dauerhaftigkeit des betreffenden Bauteils bzw. des gesamten Bauwerks beeinträchtigen kann. Für einen chemischen Angriff in natürlichen Böden und Grundwässern bestehen normative Vorgaben in DIN 4030-1 [R10] bzw. DIN 1045-2 [R19], um den Angriffsgrad anhand der Art und Konzentration der angreifenden Stoffe in Expositionsklassen XA1 (schwach angreifend) bis XA3 (stark angreifend) einzustufen. Hinsichtlich weiterer maßgeblicher Einflussfaktoren wird an dieser Stelle nicht näher differenziert, ob und inwieweit die Regelungen für Böden und Grundwässer auch auf andere Bereiche mit chemischem Angriff auf Beton zu übertragen sind, ist stets im Einzelfall zu überprüfen. Ebenfalls sind die zu treffenden Maßnahmen über die Vorgaben der DIN EN 206-1/DIN 1045-2 [R19] hinaus anwendungsspezifisch festzulegen. Der Hauptausschuss Baustofftechnik (HABT) des DBV hat daher den Arbeitskreis "Chemischer Angriff auf Beton" beauftragt, dieses Merkblatt zu erarbeiten, das Hilfestellung bei der Bewertung einer projektspezifischen chemischen Angriffssituation auf Beton sowie bei der Planung und Ausführung von Schutzprinzipien leisten soll. KW - Beton KW - Betonangriff KW - Dauerhaftigkeit KW - Säureangriff KW - Sulfatangriff PY - 2014 SP - 1 EP - 101 PB - Eigenverlag Deutscher Beton- und Bautechnik-Verein e. V. CY - Berlin AN - OPUS4-44662 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Preß, Henning A1 - Seifert, B. A1 - Wagner, H. M. T1 - Vergleich von Meßverfahren zur Bestimmung von Ozon PY - 1976 SN - 0932-6200 SN - 0016-9277 SN - 0720-9312 VL - 97 IS - 9 SP - 225 EP - 228 PB - Oldenbourg CY - München AN - OPUS4-8577 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Preß, Henning A1 - Wagner, H. M. T1 - Entstehen und Eigenschaften von gesundheitsschädlichen Gasen und Stäuben (Kurzfassung) PY - 1976 SN - 0340-7551 VL - 6 IS - 3 SP - 103 EP - 105 PB - Bundesanstalt für Materialprüfung CY - Berlin AN - OPUS4-8579 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharlach, C. A1 - Müller, Larissa A1 - Wagner, S. A1 - Kobayashi, Y. A1 - Kratz, H. A1 - Ebert, M. A1 - Jakubowski, Norbert A1 - Schellenberger, E. T1 - LA-ICP-MS allows quantitative microscopy of europium-doped iron oxide nanoparticles and is a possible alternative to ambiguous Prussian blue iron staining N2 - The development of iron oxide nanoparticles for biomedical applications requires accurate histological evaluation. Prussian blue iron staining is widely used but may be unspecific when tissues contain substantial endogenous iron. Here we tested whether microscopy by laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) is sensitive enough to analyze accumulation of very small iron oxide particles (VSOP) doped with europium in tissue sections. KW - Atherosclerotic plaques KW - LA-ICP-MS microscopy KW - Quantification KW - Element microscopy KW - Histology PY - 2016 DO - https://doi.org/10.1166/jbn.2016.2230 SN - 1550-7033 SN - 1550-7041 VL - 12 IS - 5 SP - 1001 EP - 1010 AN - OPUS4-36189 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Budnik, J. A1 - Betz, T. A1 - Brameshuber, W. A1 - Fromm, A. A1 - Gerdes, A. A1 - Gerlach, J. A1 - Götz, M. A1 - Hart, R. A1 - Heese, C. A1 - Hintzen, W. A1 - Hüttl, R. A1 - Kämpfer, W. A1 - König, A. A1 - Kühner, S. A1 - Lohaus, L. A1 - Meng, Birgit A1 - Neumann, T. A1 - Remus, R. A1 - Schaab, A. A1 - Schäffel, P. A1 - Schauerte, J. A1 - Schönborn, A. A1 - Siebert, B. A1 - Stephan, D. A1 - Tebbe, H. A1 - Wagner, J.-P. ED - Siebert, B. T1 - Chemischer Angriff auf Beton - Empfehlungen zur Prüfung und Bewertung N2 - ln den letzten Jahren wurden diverse Prüfverfahren und Methoden entwickelt, um die Leistungsfähigkeit von Beton bzw. Bindemittel hinsichtlich des Widerstands gegenüber betonaggressiven Einwirkungen beurteilen zu können. Ein wesentliches Ziel von Prüfverfahren zur Beurteilung der Dauerhaftigkeit von Baustoffen ist, die im Laufe der Nutzungsdauer zu erwartenden Einwirkungen auf den Baustoff realitätsnah abzubilden. Dazu sind die Prüfparameter auf die im jeweiligen Anwendungsbereich vorherrschenden Umgebungs- und Randbedingungen anzupassen. Daneben sind auch die Bewertungskriterien individuell unter Berücksichtigung der im Einzelfall geforderten Nutzungsdauer eines Bauwerks festzulegen. Eine systematische Zuordnung von adäquaten Prüfverfahren bzw. Prüfparametem und Bewertungskriterien für die verschiedenen Anwendungsbereiche im Betonbau, in denen betonaggressive Einwirkungen auftreten, ist mit Ausnahme von Einzelfällen bislang nicht vorhanden. Daneben stellt sich in der Praxis immer wieder das Problem, das Angriffspotenzial der Umgebung eines Bauwerks (prüftechnisch) zu erfassen und zu bewerten. Der Hauptausschuss Baustofftechnik des DBV hat daher den Arbeitskreis „Chemischer Angriff auf Beton“ beauftragt, dieses Merkblatt zu erarbeiten, das auf Basis von einschlägigen Erfahrungen der Baupraxis und wissenschaftlichen Erkenntnissen Grundsätze und bewährte Methoden zur Beurteilung der Einwirkungs- und Widerstandsseite beim chemischen Angriff auf Beton aufzeigt und diesbezüglich Hinweise für verschiedene Anwendungsbereiche im Betonbau liefert. KW - Beton KW - Betonangriff KW - Dauerhaftigkeit KW - Säureangriff PY - 2017 SP - 1 EP - 65 PB - Eigenverlag Deutscher Beton- und Bautechnik-Verein e. V. CY - Berlin AN - OPUS4-44663 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wagner, M.H. A1 - Mielke, Werner T1 - Golden Jubilee Meeting of the German Society of Rheology (DRG), Berlin, Germany PY - 2002 DO - https://doi.org/10.1007/s00397-002-0240-4 SN - 0035-4511 SN - 1435-1528 VL - 41 IS - 4 SP - 290 EP - 291 PB - Springer CY - Berlin AN - OPUS4-1565 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seefeldt, Henrik A1 - Braun, Ulrike A1 - Wagner, M.H. T1 - Residue stabilization in the fire retardancy of wood-plastic composites: combination of ammonium polyphosphate, expandable graphite, and red phosphorus N2 - Combinations of different common flame retardants in wood–plastic composites (WPCs) are tested to identify synergistic or antagonistic effects with the goal of improving the fire performance of WPCs. Flame retardants investigated are expandable graphite (EG), ammonium polyphosphate (APP), and red phosphorus (RP) and combinations of two of them are used. The fire behavior is studied by cone calorimetric measurements. Additional thermogravimetry is used for further investigations. The fire tests show that EG has the highest potential for flame retardancy, but due to its expansion it cracks the formed residue layer. Combinations of EG with RP or with high amounts of APP are able to suppress this cracking. KW - Flame retardance KW - Halogen free KW - Renewable resources KW - Wood-plastic composites KW - WPC PY - 2012 DO - https://doi.org/10.1002/macp.201200119 SN - 1022-1352 SN - 1521-3935 VL - 213 IS - 22 SP - 2370 EP - 2377 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-27489 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wagner, M.H. A1 - Wu, W. A1 - Liu, Y. A1 - Qian, Q. A1 - Zhang, Y. A1 - Mielke, Werner T1 - Study on Phase Separation of PET/PEN Blends by Dynamic Rheology N2 - Blends of poly(ethylene terephthalate) (PET) and poly(ethylene naphthalate) (PEN) were processed into biaxially drawn films, and samples taken from the bi-oriented films were then investigated by dynamic rheology experiments in the melt state. Storage modulus G and loss modulus G were determined in the frequency range of 10-2-102 rad/s at temperatures between 260 and 300°C. Although the time-temperature superposition (TTS) principle was found to hold in the high frequency regime, a breakdown of TTS was observed at low frequencies, and the terminal behavior of the storage modulus G of the blends departs drastically from the terminal behavior observed for the blend components. This is caused by interfacial surface tension effects. The results indicate that despite the effect of transesterification reactions, the PET/PEN blend systems investigated consist of a microseparate phase of PEN platelets in a matrix of PET. This morphology is produced when the blends are processed into biaxially oriented PET/PEN films, and droplets of PEN are deformed into a lamellar structure consisting of parallel and extended, separate layers. The large interfacial surface area of the bi-oriented PET/PEN blends leads to remarkably strong interfacial tension effects in dynamic rheology measurements. KW - PET/PEN blends KW - Phase separation KW - Dynamic rheology KW - Bi-oriented films KW - Time-temperature superposition KW - Surface tension PY - 2008 DO - https://doi.org/10.1002/app.28156 SN - 0021-8995 SN - 1097-4628 VL - 110 IS - 1 SP - 177 EP - 182 PB - Wiley InterScience CY - Hoboken, NJ AN - OPUS4-17817 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -