TY - JOUR A1 - Zhou, F. A1 - Ma, C. A1 - Zhang, K. A1 - Chan, Yin Yam A1 - Xiao, Y. A1 - Schartel, Bernhard A1 - Döring, M. A1 - Wang, B. A1 - Hu, W. A1 - Hu, Y. T1 - Synthesis of Ethyl (Diethoxymethyl)phosphinate Derivatives and Their Flame Retardancy in Flexible Polyurethane Foam: Structure-flame Retardancy Relationships N2 - Three novel liquid ethyl (diethoxymethyl)phosphinate derivatives (EDPs) were synthesized and incorporated into flexible polyurethane foams (FPUFs). The flame retardancy of FPUFs were evaluated by limiting oxygen index (LOI), vertical burning and cone calorimetry tests, and the results indicated the structure-flame retardancy relationship of EDPs. Among these EDPs, P-(diethoxymethyl)-N-phenylphosphonamidate (EDPPA) exhibited the best flame retardant effect, methyl 3-((diethoxymethyl)(ethoxy)phosphoryl)propanoate (EDPMA) the second, and ethyl phenyl (di-ethoxymethyl)phosphonate (EDPPO) the worst. When the incorporation of EDPPA was 10 wt%, the FPUFs could self-extinguish and pass the vertical burning test. Meanwhile, the LOI value of FPUF-PA increased to 23.6% with 20 wt% loading of flame retardant. According to the investigation of volatiles during the thermal degradation of FPUFs and the morphologies of char residues after cone test, we inferred the pos- sible flame retardant mechanism. The results indicated that EDPs could release phosphorus-containing compounds in the gas phase, which would generate phosphorus-containing radicals and play the role of radical scavenger. In the condensed phase, EDPs can promote the formation of dense, intact and thermal stably char layer on the surface of FPUFs. Moreover, we found that the structure influence on flame retardancy was attributed to the atoms linked to the central phosphorus. Our results indicate that these EDPs are promising flame retardants in FPUFs that can be applied to improve the flame retardancy of FPUFs in various practical applications. KW - Ethyl (diethoxymethyl)phosphinate derivatives KW - Flame retardant KW - Flexible polyurethane foam KW - Structure-flame retardancy relationship PY - 2021 U6 - https://doi.org/10.1016/j.polymdegradstab.2021.109557 SN - 0141-3910 VL - 188 SP - 109557 PB - Elsevier Ltd. AN - OPUS4-53085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ma, S. A1 - Xiao, Y. A1 - Zhou, F. A1 - Schartel, Bernhard A1 - Chan, Yin Yam A1 - Korobeinichev, O. P. A1 - Trubachev, S. A. A1 - Hu, W. A1 - Ma, C. A1 - Hu, Y. T1 - Effects of novel phosphorus-nitrogen-containing DOPO derivative salts on mechanical properties, thermal stability and flame retardancy of flexible polyurethane foam N2 - In this work, a series of 9,10-dihydro-9-oxa-10-phosphaphenanthrene-10-oxide (DOPO) derivative salts containing phosphorus and nitrogen were synthesized, and their effects on mechanical properties, thermal stability and flame retardancy of flexible polyurethane foam (FPUF) were investigated. Studies have shown that the addition of DOPO derivatives will increase the tensile strength, compression set, and compression hardness of FPUF, but it will lead to a decrease in elongation at break. Thermogravimetric analysis showed that the initial decomposition temperature of FPUF containing DOPO derivatives was reduecd, but the char reside was significantly improved. A series of combustion tests indicated that the addition of DOPO derivative salts can improve the flame retardancy of FPUF, of which 10-hydroxy-9,10-dihydro-9-oxa-10 phosphaphenanthrene-10-oxide dicyandiamide salt (D-DICY) exhibited the best flame retardancy. When the load of D-DICY was 20 phr, the limiting oxygen index (LOI) of foam reached 24.5%, and the peak heat release rate and total heat release were decreased by 55.7% and 52.9%, respectively. Furthermore, based on the analysis of the gas phase combustion products and the char residue of the condensed phase, the possible flame retardant mechanism was proposed. KW - Flexible polyurethane foam KW - DOPO derivative salts KW - Mechanical properties KW - Thermal stability KW - Flame retardancy PY - 2020 U6 - https://doi.org/10.1016/j.polymdegradstab.2020.109160 SN - 0141-3910 VL - 177 SP - 109160 PB - Elsevier Ltd. AN - OPUS4-50740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hu, W. A1 - Said, Samir A1 - Rohrmann, R. A1 - Teng, J. A1 - Li, Z. A1 - Lu, W. A1 - Cunha, A. T1 - Operational modal analysis and continuous dynamic monitoring of structures N2 - This paper addresses operational modal analysis (OMA) and continuous dynamic monitoring (CDM) of two bridges. One of them is installed with Tuned Mass Dampers (TMDs) while another one is a normal bridge. Two ambient vibration tests were performed on these two bridges respectively. It is observed that not only installation of TMDs but also environmental factors influence the variations of structural frequencies, which may mask the subtle change induced by small structural changes. As a result, continuous dynamic monitoring systems were implemented on these two bridges, in order to evaluate efficiency of the TMD system, remove the environmental effects and build reliable damage indices that are only sensitive to structural changes. The results of CDM of these two bridges during several years are presented. Software systems developed for OMA and CDM are also introduced. T2 - 14th International Symposium on Structural Engineering (ISSE-14) CY - Beijing, Peoples Republic of China DA - 12.10.2016 KW - Structure KW - Operational modal analysis KW - Continuous dynamic monitoring PY - 2016 SN - 978-7-03-050125-7 VL - 2016 SP - 366 EP - 372 PB - Science Press Beijing AN - OPUS4-38876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Risinggård, H. K. A1 - Cooil, S. A1 - Mazzola, F. A1 - Hu, D. A1 - Kjaervik, Marit A1 - Østli, E. R. A1 - Patil, N. A1 - Preobrajenski, A. A1 - Ewans, A. D. A1 - Breiby, D. W. A1 - Trinh, T. T. A1 - Wells, J. W. T1 - Degradation of the chemotherapy drug 5-fluorouracil on medical-grade silver surfaces N2 - The degradation of the chemotherapy drug 5-fluorouracil by a non-pristine metal surfaces is studied.Using density functional theory, X-ray photoelectron spectroscopy and X-ray absorption spectroscopy we show that the drug is entirely degraded by medical-grade silver surfaces, already at body temperature,and that all of the fluorine has left the molecule, presumably as HF. Remarkably, this degradation is even more severe than that reported previously for 5-fluorouracil on a pristine monocrystalline silver surface(in which case 80% of the drug reacted at body temperature) [1]. We conclude that the observed reaction is due to a reaction pathway, driven by H to F attraction between molecules on the surface, which results in the direct formation of HF; a pathway which is favoured when competing pathways involving reactive Ag surface sites are made unavailable by environmental contamination. Our measurements indicate that realistically cleaned, non-pristine silver alloys, which are typically used in medical applications, can result in severe degradation of 5-fluorouracil, with the release of HF – a finding which may have important implications for the handling of chemotherapy drugs. KW - Surface science KW - Chemotherapy KW - DFT KW - Photoemission KW - Fluorouracil KW - Silver PY - 2018 U6 - https://doi.org/10.1016/j.apsusc.2017.11.221 SN - 0169-4332 VL - 435 SP - 1213 EP - 1219 PB - Elsevier CY - Amsterdam, The Netherlands AN - OPUS4-43450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hu, W.-H. A1 - Xu, Z.-M. A1 - Liu, M.-Y. A1 - Tang, D.-H. A1 - Lu, W. A1 - Li, Z.-H. A1 - Teng, J. A1 - Han, X.-H. A1 - Said, Samir A1 - Rohrmann, R. G. T1 - Estimation of the Lateral Dynamic Displacement of High-Rise Buildings underWind Load Based on Fusion of a Remote Sensing Vibrometer and an Inclinometer N2 - This paper proposes a novel method to estimate the lateral displacement of high-rise structures under wind loads. The coefficient β(x) is firstly derived, reflecting the relation between the structural lateral dynamic displacement and the inclination angle at the height x of a structure. If the angle is small, it is the ratio between the structural fundamental mode shape and its first-order derivative without influence of external loads. Several dynamic experiments of structures are performed based on a laser remote sensing vibrometer and an inclinometer, which shows that the fundamental mode is dominated in the structural displacement response under different types of excitations. Once the coefficient β(x) is curve-fitted by measuring both the structural lateral dynamic displacement and the inclination angle synchronously, the real-time structural lateral displacement under operational conditions is estimated by multiplying the coefficient β(x) with the inclination angle. The advantage of the proposed method is that the coefficient β(x) can be identified by lateral dynamic displacement measured in high resolution by the remote sensing vibrometer, which is useful to reconstruct the displacement accurately by the inclination angle under operational conditions KW - Inclination angle KW - High-rise building KW - Lateral dynamic displacement KW - Remote sensing vibrometer PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-506833 VL - 12 IS - 7 SP - 1120 PB - MDPI CY - 4052 Basel, Schweiz AN - OPUS4-50683 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hu, W.-H A1 - Tang, D.-H. A1 - Wang, M. A1 - Liu, J.-L. A1 - Li, Z.-H. A1 - Lu, W. A1 - Teng, J. A1 - Said, Samir A1 - Rohrmann, R. G. T1 - Resonance Monitoring of a Horizontal Wind Turbine by Strain-Based Automated Operational Modal Analysis N2 - A strain-based automated operational modal analysis algorithm is proposed to track the long-term dynamic behavior of a horizontal wind turbine under operational conditions. This algorithm is firstly validated by a scaled wind turbine model, and then it is applied to the dynamic strain responses recorded from a 5 MW wind turbine system. We observed variations in the fundamental frequency and 1f, 3f excitation frequencies due to the mass imbalance of the blades and aerodynamic excitation by the tower dam or tower wake. Inspection of the Campbell diagram revealed that the adverse resonance phenomenon and Sommerfeld effect causing excessive vibrations of the wind tower. KW - Strain KW - Automated operational modal analysis KW - Resonance KW - Horizontal wind turbine PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-503350 VL - 13 IS - 3 SP - 579 EP - 584 PB - MDPI CY - Schweiz, Basel AN - OPUS4-50335 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Braun, M.-T. A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Marquardt, E. A1 - Mayr, M. A1 - Nickel, H.-U. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. ED - Jonuscheit, J. ED - Marquardt, E. T1 - Terahertzsysteme und Anwendungsfelder N2 - Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports. KW - Terahertzsysteme PY - 2020 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/terahertzsysteme-und-anwendungsfelder SP - 1 EP - 44 PB - Verein Deutscher Ingenieure (VDI) CY - Düsseldorf AN - OPUS4-50556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hu, W.-H. A1 - Said, Samir A1 - Rohrmann, R. A1 - Cunha, À. A1 - Teng, J. T1 - Continuous dynamic monitoring of a prestressed concrete bridge based on strain, inclination and crack measurements over a 14-year span N2 - The Westend Bridge is located on the A100 Highway in Berlin. An integrated continuous dynamic monitoring system, composed of 20 velocity sensors, 5 temperature sensors, 3 strain gauges, 1 crack sensor and 2 inclination sensors, was implemented by the Federal Institute for Materials Research and Testing in 2000. The system runs continuously with occasional intermittence and led to a huge amount of data over a 14-year span. In this article, variations of the strain, crack and inclination measurements during the last 14 years are presented. It is noted that the observed crack and inclination of the bridge are strongly influenced by seasonal temperature variation. It further induces change in the relationship between the strains measured in both concrete and prestressed tendon. Application of k-means cluster Analysis technique in both the crack and strain measurements can partition them into different seasonal phases by identifying ‘turning points’ that indicate annual periodical bridge change. In the period of these two ‘turning points’, a strong linear relation of the strains in two materials is observed. In the rest of the year, a nonlinear relationship between the strains recorded in both the concrete and the prestressed tendon is noted. The possible reason is the additional thermal load due to the change in temperature difference between the bridge’s surface and soffit. Finally, a health index in a Framework of regression model and process control theory is proposed by investigating the linear relationship between the strains in concrete and prestressed tendon. The tendency of the health index in the 14 years may suggest the long-term bridge change during that time frame. KW - Detection of structural change KW - Structural health monitoring KW - Strain KW - Crack KW - Inclination KW - Bridge PY - 2017 U6 - https://doi.org/10.1177/1475921717735505 VL - 17 IS - 5 SP - 1073 EP - 1094 PB - SAGE CY - USA/UK AN - OPUS4-45990 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hu, W.‐H. A1 - Álvaro Cunha, Á. A1 - Caetano, E. A1 - Rohrmann, R. G. A1 - Said, Samir A1 - Teng, J. T1 - Comparison of different statistical approaches for removing environmental/operational effects for massive data continuously collected from footbridges N2 - The implementation of continuous dynamic monitoring systems in two bridges, in Portugal, is enabled to detect the occurrence of very significant environmental and operational effects on the modal properties of these bridges, based on automated processing of massive amounts of monitoring data collected by a set of accelerometers and thermal sensors over several years. In order to remove or mitigate such environmental/operational effects with the purpose of damage detection, two different statistical methods have been adopted. One of them is the multiple linear regression by performing nonlinear correlation analysis between measured modal properties and environmental/operational variables. Another one is principal component regression based on the identification of the linear subspace within the modal properties without using measured values of environmental and operational variables. This paper presents a comparison of the performance of these two alternative approaches on the basis of continuous monitoring data acquired from two instrumented bridges and simulated damage scenarios. It is observed that different methods show similar capacity in removing environmental effects, and the multiple linear regression method is slightly more sensitive to structural damage. KW - Multiple linear KW - Damage detection KW - Environmental/operational effect KW - Modal property PY - 2017 U6 - https://doi.org/10.1002/stc.1955 SN - 1545-2255 VL - 24 IS - 8 SP - e1955-1 EP - e1955-19 PB - John Wiley & Sons, Ltd AN - OPUS4-41147 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -