TY - CONF A1 - Vogl, Jochen T1 - Isotope Dilution Mass Spectrometry - A primary method of measurement and its role for RM certification T2 - Workshop on Metrology in Chemistry at NPL CY - New Delhi, India DA - 2009-02-16 PY - 2009 AN - OPUS4-19136 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rosner, Martin A1 - Pritzkow, Wolfgang A1 - Vogl, Jochen A1 - Voerkelius, S. T1 - Boron isotope compositions of crop plants: A new tracer for the origin and authenticity of food T2 - TRACE 5th Annual Meeting and Conference CY - Freising, Germany DA - 2009-04-01 KW - Boron isotopes in food KW - Provenance studies KW - Reference materials KW - Analytical uncertainty PY - 2009 IS - Session A / Part I SP - 1 EP - 2 AN - OPUS4-20293 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Traceability in Environmental Analysis Possible Routes and examples from Germany for elemental analysis T2 - Seminar: Metrology in Chemistry CY - New Delhi, India DA - 2010-03-12 PY - 2010 AN - OPUS4-21030 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Development and validation of a single collector ICPMS procedure for the determination of boron isotopic variations in food and water samples T2 - 9. Symposium Massenspektrometrische Verfahren der Elementspurenanalyse, 22. ICP-MS Anwendertreffen CY - Berlin, Germany DA - 2010-09-06 PY - 2010 AN - OPUS4-22562 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Pritzkow, Wolfgang T1 - Isotope dilution mass spectrometry - a primary method of measurement and its role for RM certification KW - IDMS KW - Reference materials KW - Metrology KW - ICPMS KW - TIMS PY - 2010 SN - 0970-3950 VL - 25 IS - 3 SP - 135 EP - 164 PB - Metrology Society of India CY - New Delhi AN - OPUS4-22603 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Rosner, Martin A1 - Pritzkow, Wolfgang T1 - Development and validation of a single collector SF-ICPMS procedure for the determination of boron isotope ratios in water and food samples N2 - Boron isotope studies on technical materials and geological and environmental samples are one hot topic in nowadays isotope research. Provenance studies of artefacts, food and other products might become another one, as several recent studies demonstrate. Typically boron isotope determinations have been carried out by TIMS. To open up this research field to a broader scientific community we developed two analytical procedures for boron isotope determinations based on single collector SF-ICPMS combined with a sample preparation procedure consisting of dry-ashing and a three step ion chromatographic boron-matrix separation. The developed procedures consist of one low resolution (LR) and one medium resolution (MR) procedure. The repeatability for the δ11B determination in three independently measured aliquots lies between 0.2 and 0.8‰ for the LR procedure and between 0.3 and 1.5‰ for the MR procedure. The expanded uncertainties with a coverage factor of k=2 range between 1.4 and 1.6‰ for the LR procedure and between 2.9 and 3.2‰ for the MR procedure. The accuracy, expressed as average deviation from the reference values, is 0.43‰ for the LR procedure and 0.33‰ for the MR procedure. To test the practicability of the procedures the matrix tolerance has been investigated as well and was found to be up to 2 mg kg-1 of alkaline and alkaline earth elements in the final measurement solution containing 100 µg kg-1 boron. Thus a highly efficient matrix separation for SF-ICPMS boron isotope determinations is required, similar to TIMS. PY - 2011 DO - https://doi.org/10.1039/c0ja00220h SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 4 SP - 861 EP - 869 PB - Royal Society of Chemistry CY - London AN - OPUS4-23419 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rosner, Martin A1 - Pritzkow, Wolfgang A1 - Vogl, Jochen A1 - Voerkelius, S. T1 - Development and validation of a method to determine the boron isotopic composition of crop plants N2 - We present a comprehensive chemical and mass spectrometric method to determine boron isotopic compositions of plant tissue. The method including dry ashing, a three-step ion chromatographic boron–matrix separation, and 11B/10B isotope ratio determinations using the Cs2BO2+ graphite technique has been validated using certified reference and quality control materials. The developed method is capable to determine δ11B values in plant tissue down to boron concentrations of 1 mg/kg with an expanded uncertainty of ≤1.7‰ (k = 2). The determined δ11B values reveal an enormous isotopic range of boron in plant tissues covering three-quarters of the natural terrestrial occurring variation in the boron isotopic composition. As the local environment and anthropogenic activity mainly control the boron intake of plants, the boron isotopic composition of plants can be used for food provenance studies. KW - Boron isotope variations KW - Delta-scale KW - Stable isotopes KW - Isotope reference materials KW - Provenance KW - Authenticity PY - 2011 DO - https://doi.org/10.1021/ac102836h SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 7 SP - 2562 EP - 2568 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Report from the KCRV working group meeting T2 - CCQM-IAWG-Meeting CY - Paris, France DA - 2008-04-01 PY - 2008 AN - OPUS4-17516 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Isotope ratio measurements - An Introduction T2 - CCQM IAWG-Meeting, Workshop "Isotope Ratios" CY - Paris, France DA - 2008-04-01 PY - 2008 AN - OPUS4-17517 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Characterization of isotope and matrix reference materials using multicollector instruments T2 - 8th International Sector Field ICPMS Conference CY - Ghent, Belgium DA - 2009-09-14 PY - 2009 AN - OPUS4-20434 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Isotope Reference Materials for Future Isotope Research T2 - IUPAC-Meeting, Kommission für die Atomgleichgewichtsbestimmung CY - Vienna, Austria DA - 2009-07-23 PY - 2009 AN - OPUS4-20436 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Vogl, Jochen A1 - Gusarova, Tamara A1 - Czerwensky, Michael A1 - Heinrich, Hans-Joachim A1 - Hioki, A. A1 - Konopelko, L.A. A1 - Methven, B. A1 - Miura, T. A1 - Petersen, O. A1 - Riebe, Gundel A1 - Sturgeon, R. A1 - Turk, G.C. A1 - Yu, L. L. T1 - Purity determination as needed for the realisation of primary standards for elemental determination: status of international comparability N2 - Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established. KW - Interlaboratory comparison KW - Purity analysis KW - High purity metals KW - CCQM-P107 KW - Zinc PY - 2010 DO - https://doi.org/10.1007/s00769-009-0557-0 SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 29 EP - 37 PB - Springer CY - Berlin AN - OPUS4-20767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Semkova, V. A1 - Reimer, P. A1 - Altzitzoglou, T. A1 - Plompen, A.J.M. A1 - Quétel, C. A1 - Sudár, S. A1 - Vogl, Jochen A1 - Koning, A.J. A1 - Qaim, S.M. A1 - Smith, D.L. T1 - Neutron activation cross sections on lead isotopes KW - Cross sections KW - Neutron activation KW - Lead isotopes PY - 2009 DO - https://doi.org/10.1103/PhysRevC.80.024610 SN - 0556-2813 SN - 1089-490X VL - 80 IS - 2 SP - 024610-1 - 024610-12 PB - Inst. CY - Woodbury, NY, USA AN - OPUS4-20698 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rosner, Martin A1 - Pritzkow, Wolfgang A1 - Vogl, Jochen T1 - Boron isotope compositions of food: A potential tool for food authentication T2 - Jahrestagung Deutsche Mineralogische Gesellschaft 2008 CY - Berlin, Deutschland DA - 2008-09-14 KW - Boron isotopes KW - Food KW - Provenance studies PY - 2008 SP - 1 CY - Berlin AN - OPUS4-20785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ma, L. A1 - Feng, L. A1 - Hioki, A. A1 - Cho, K.H. A1 - Vogl, Jochen A1 - Berger, Achim A1 - Turk, G. A1 - Macleod, S. A1 - Labarraque, G. A1 - Tong, W.F. A1 - Schiel, D. A1 - Yafa, C. A1 - Valiente, L. A1 - Konopelko, L.A. A1 - Quetel, C. A1 - Vermaercke, P. A1 - Manzano, J.V.L. A1 - Linsky, M. A1 - Cortés, E. A1 - Tangpitayakul, S. A1 - Plangsangmas, L. A1 - Bergamaschi, L. A1 - Hearn, R. T1 - International comparison of the determination of the mass fraction of cadmium, chromium, mercury and lead in polypropylene: the Comité Consultatif pour la quantité de matière pilot study CCQM-P106 KW - Cadmium KW - Chromium KW - Mercury KW - Lead KW - Polypropylene KW - CCQM PY - 2010 DO - https://doi.org/10.1007/s00769-009-0574-z SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 39 EP - 44 PB - Springer CY - Berlin AN - OPUS4-20787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Koenig, Maren A1 - Pritzkow, Wolfgang A1 - Riebe, Gundel T1 - Development of reference procedures for the quantification of toxic metals and S in plastics N2 - The quantitative analysis of toxic metals in plastics is very important for different sectors of industry and daily life. Many routine procedures have been established based on X-ray fluorescence or inductively coupled plasma atomic emission spectrometry. However, all of them require suitable reference materials to calibrate or validate. These reference materials ideally are being certified by reference procedures. The development of such reference procedures for sulfur and the four toxic elements cadmium, chromium, mercury and lead in plastics is described here. The procedures are based on double isotope dilution mass spectrometry including analyte–matrix separation. The applied mass spectrometric techniques are thermal ionization mass spectrometry as well as inductively coupled plasma mass spectrometry. Memory effects of mercury and dissolution of chromium(III) oxide have been considered especially. The expanded uncertainties have been improved from the percent range down to the per mill range during the development of the procedure from the early analysis of BCR-680/681 to the recent analysis of CCQM-P106. With the fully developed procedures expanded uncertainties (k = 2) between 0.1 and 0.4% for cadmium, chromium, lead and sulfur and around 1% for mercury can be achieved. The so developed procedures have been successfully applied to the certification of reference materials as well as to intercomparisons organized by CCQM. KW - ICPMS KW - TIMS KW - Reference materials KW - IDMS PY - 2010 DO - https://doi.org/10.1039/c0ja00034e SN - 0267-9477 SN - 1364-5544 VL - 25 IS - 10 SP - 1633 EP - 1642 PB - Royal Society of Chemistry CY - London AN - OPUS4-22044 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ostermann, Markus A1 - Kettisch, P. A1 - Becker, Dorit A1 - Vogl, Jochen T1 - Measurements of sulfur in oil using pressurised wet digestion technique in open vessels and isotope dilution mass spectrometry KW - Wet digestion KW - Open vessel digestion KW - Sulfur in oil KW - Reference materials KW - TIMS KW - IDMS PY - 2003 UR - http://www.springerlink.com/content/b7alk8lgly2v/?p=6237db8a9c28481d87e7b017e6474b73&pi=88 SN - 1618-2642 SN - 1618-2650 VL - 377 IS - 4 SP - 779 EP - 783 PB - Springer CY - Berlin AN - OPUS4-2738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogl, Jochen A1 - Klingbeil, Patrick A1 - Pritzkow, Wolfgang A1 - Riebe, Gundel T1 - High accuracy measurements of Fe isotopes using hexapole collision cell MC-ICP-MS and isotope dilution for certification of reference materials N2 - An ICP-MS equipped with collision cell, sector field and multi-collector technology has been applied to developing analytical procedures for Fe in terms of isotope ratio measurements and isotope dilution analysis. Therefore a detailed study on the reduction of molecular interferences by a variety of collision gases (He, Ar, Kr, H2, D2 and N2) was performed. The efficiency of the reduction has been checked by high resolution mass scans. The argon based interferences disturbing the determination of 54Fe and 56Fe could be completely removed when using Faraday detectors. The interferences on mass 57 could be reduced to a level which enables accurate measurements. Also, the 40Ar12C interference, which disturbs the chromium correction, could be completely removed. Reproducibilities of 0.01% could be reached for 54Fe/56Fe isotope ratios and 0.02% for 57Fe/56Fe isotope ratios. Under these measurement conditions a sensitivity of 1.2 V per 50 µg kg–1 Fe is available. This corresponds to 1.5 × 109 cps per mg kg–1. Based on these results highly accurate procedures for Fe isotope ratio determinations were set up, reaching a performance level superior to that of other ICP-MS instruments. Consequently, IDMS procedures were developed on this basis in order to perform certification measurements at the highest metrological level. The first application was the contribution to the Fe reference value by IMEP-12, an interlaboratory comparison with approximately 350 participants worldwide. The analysed Fe mass content is 0.2150 mg kg–1 with its expanded uncertainty (k= 2) of 0.0012 mg kg–1(0.56%), which is ten times less than the uncertainty of the second certification laboratory. Another application was the certification campaign of the two reference materials Tea Leaves and Polish Herbs. The results obtained with the ICP-MS procedure, 542 ± 11 mg kg–1 and 543 ± 12 mg kg–1, were compared with the results analysed by TIMS, 541 ± 12 mg kg–1 and 541 ± 13 mg kg–1, and agree very well within the stated uncertainties (k= 2). The results presented demonstrate quite well the suitability of the developed IDMS procedures for certification or reference measurements. PY - 2003 DO - https://doi.org/10.1039/b301812a SN - 0267-9477 SN - 1364-5544 VL - 18 SP - 1125 EP - 1132 PB - Royal Society of Chemistry CY - London AN - OPUS4-2739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Einstieg in die massenspektrometrische Isotopenverdünnungsanalyse T2 - 1. Workshop "Isotopenverdünnungsanalyse mit ICP-MS" CY - Berlin, Germany DA - 2002-11-11 PY - 2002 AN - OPUS4-3006 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Fortschritte in der Isotopenverhältnis- und Isotopenverdünnungsanalyse - "Anything elements do, isotopes do better" T2 - Jahrestagung der DGMS 2002 CY - Heidelberg, Germany DA - 2002-03-03 PY - 2002 AN - OPUS4-3007 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen T1 - Zertifizierung von Referenzmaterialien sowie Referenzanalysen mittels T2 - IDMSBeraterkreis I. Abteilung CY - Berlin, Germany DA - 2002-05-08 PY - 2002 N1 - Geburtsname von Dudek, Gabriele: Wermann, G. - Birth name of Dudek, Gabriele: Wermann, G. AN - OPUS4-3008 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bohn, T. A1 - Walczyk, Th. A1 - Davidsson, L. A1 - Pritzkow, Wolfgang A1 - Klingbeil, Patrick A1 - Vogl, Jochen A1 - Hurrell, R.F. T1 - Comparison of urinary monitoring, faecal monitoring and erythrocyte analysis of stable isotope labels to determine magnesium absorption in human subjects KW - Magnesium absorption KW - Stable isotopes KW - Faecal monitoring KW - Urinary monitoring KW - Erythrocytes PY - 2004 SN - 0007-1145 SN - 1475-2662 VL - 58 SP - 113 EP - 120 PB - CABI Publ. CY - Wallingford AN - OPUS4-3362 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -