TY - CONF A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg T1 - Knowledge Infrastructure supporting image-based characterisation of 2D graphene materials N2 - To better understand the relationship between image features and biological effects such as toxicity,we have developed a method combining image thresholding and pixel-wise segmentation to create annotated datasets. These datasets are used to train machine learning models and establish human–AI learning loops for material classification and structure detection. We employ deep learning architectures such as ResNet, EfficientNet, and U-Net to automate the classification and segmentation of SEM/TEM images of 2D nanomaterials, with targeted manual annotation focusing on key structures (graphene flakes, agglomerates, contaminants, etc.). This approach ensures reproducible, large-scale analysis, which is essential for studying the links between structure and biological response. Finally, our methodology aligns with OECD requirements and contributes to the Safe and Sustainable by Design (SSbD) framework, aiming to enhance product reliability and sustainability. T2 - Joint Regulatory Risk Assessors Summit – Advancing Safety & Sustainability Assessments of Advanced Materials CY - Paris, France DA - 19.06.2025 KW - Graphene KW - 2D materials KW - Knowledge infrastructure KW - Imaging KW - Machine learning PY - 2025 UR - https://macrame-project.eu/macrame-meetings-workshops/jointrras/#Agenda AN - OPUS4-63682 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Measurement of Elemental Composition of and SiGe Alloy Thin Films by EPMA and µ-XRF N2 - The present study reports on measurements on thin Fe-Ni films on silicon and first-time results of analysis on Si-Ge thin films deposited on a non-conductive aluminium oxide Substrate by electron probe microanalysis (EPMA). Standard-based and standardless EPMA (with EDS) results were used in combination with the thin film analysis software Stratagem for the quantification. Further, X-ray fluorescence analysis (XRF) can be used for the determination of elemental composition and thickness of such films as well. In this case, XRF with a μ-focus X-ray source (μ-XRF) attached to a SEM was applied. For quantification, a fundamental parameter (FP) approach has been used to calculate standard-based and standardless results. Both thin film systems have been chosen as samples of an international round robin test (RRT) organised in the frame of standardisation technical committee ISO/TC 201 ‘Surface chemical analysis’, under the lead of KRISS. The main objective of the RRT is to compare the results of atomic fractions of Fe1-xNix and Si1-xGex alloy films obtained by different surface Analysis techniques, such as X-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and secondary ion mass spectrometry (SIMS) applied in the depth-profiling operation mode. Five samples of different atomic fractions of each thin film system, i.e., Fe1-xNix and Si1-xGex, have been grown by ion beam sputter deposition on silicon and Al2O3 wafers, respectively. Reference FeNi and SiGe films with well-known elemental composition and thickness have been also supplied for standard-based analysis. An excellent agreement has been obtained between the atomic fractions determined by EPMA and µ-XRF with the KRISS certified values. T2 - European Conference on Applications of Surface and Interface Analysis ECASIA 2019 CY - Dresden, Germany DA - 15.09.2019 KW - Thin films KW - EPMA KW - XRF KW - FeNi KW - SiGe PY - 2019 AN - OPUS4-49278 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - VAMAS Regional Report Germany 2024 N2 - Regional standardisation activities and how VAMAS can help in any way to promote activities are reported. Activities related to organisational updates, government initiatives/priorities (especially related to Advanced Materials), details of any strategy documents publicly available, networks within Germany and how we engage are presented. T2 - Versailles Project on Advanced Materials and Standards (VAMAS) 49th Steering Committee Meeting CY - Rio de Janeiro, Brazil DA - 23.09.2024 KW - VAMAS KW - Advanced materials KW - Standardisation PY - 2024 UR - http://www.vamas.org/ AN - OPUS4-61405 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Radtke, Martin A1 - Vincze, L. A1 - Rackwitz, Vanessa A1 - Reuter, Dirk T1 - X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation N2 - X-ray scattering may contribute significantly to the spectral background of X-ray fluorescence (XRF) spectra. Based on metrological measurements carried out with a scanning electron microscope (SEM) having attached a well characterised X-ray source (polychromatic X-ray tube) and a calibrated energy dispersive X-ray spectrometer (EDS) the accuracy of a physical model for X-ray scattering is systematically evaluated for representative samples. The knowledge of the X-ray spectrometer efficiency, but also of the spectrometer response functions makes it possible to define a physical spectral background of XRF spectra. Background subtraction relying on purely mathematical procedures is state-of-the-art. The results produced by the analytical model are at least as reliable as those obtained by Monte-Carlo simulations, even without considering the very challenging contribution of multiple scattering. Special attention has been paid to Compton broadening. Relevant applications of the implementation of the analytical model presented in this paper are the prediction of the limits of detection for particular cases or the determination of the transmission of X-ray polycapillary lenses. KW - X-ray scattering KW - X-ray fluorescence KW - Spectral background KW - Modelling KW - Monte-Carlo simulation PY - 2010 DO - https://doi.org/10.1016/j.nimb.2010.09.017 SN - 0168-583X SN - 1872-9584 VL - 268 IS - 24 SP - 3568 EP - 3575 PB - Elsevier CY - Amsterdam AN - OPUS4-22357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rades, Steffi A1 - Salge, T. A1 - Schmidt, R. A1 - Hodoroaba, Vasile-Dan T1 - Need for large-area EDS detectors for imaging nanoparticles in a SEM operating in transmission mode N2 - Accurate characterization of nanoparticles (NPs) with a high-resolution SEM with respect to morphology, shape and size distribution is carried out meanwhile routinely in more and more laboratories [1,2]. The valuable result of the metrological measurement of the NP size distribution -including traceability to the SI length unit - was also recently demonstrated by exploiting the transmission mode in a SEM, i.e. TSEM [1,3]. Especially for NPs prepared on thin foil supports like the typical TEM grids the transmission mode at low voltages (up to 30 kV) supplies a high imaging contrast so that sharp boarders of the NPs enable accurate lateral dimensional measurements of NPs size. There are just a few analytical methods which are able to characterize physico-chemical properties of individual NPs. In most cases a SEM has attached an EDS detector so that Information on the elemental composition of the sample to be analyzed becomes possible. The addressed sample volume typically in the micrometer ränge for bulk specimens is considerably reduced if thin, electron transparent Support films are used. Hence, one improves the spatial resolution however, at the cost of lower signal-to-noise ratios of the X-ray spectra, due to the tiny amount of substance excited [2,4,5]. One decisive technological development in the manufacturing of EDS detectors, namely the large-area SDD EDS, meanwhile available commercially in various designs, compensates this analytical drawback. If collection solid angles of 1-2 msr have been typically available for almost four decades, recent technological improvements in SDD EDS size and design have resulted in solid angles in the sr ränge. KW - EDS KW - EDX KW - Nanoparticles KW - High-resolution KW - SEM KW - T-SEM KW - Large-area EDS PY - 2014 DO - https://doi.org/10.1017/S1431927614005030 SN - 1431-9276 SN - 1435-8115 VL - 20 IS - Suppl. S 3 SP - 662 EP - 663 PB - Cambridge University Press CY - New York, NY AN - OPUS4-31389 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Electrospray as a sample preparation tool for electron microscopy: Toward quantitative evaluation of nanoparticles N2 - Electrospray ionization constitutes a promising deposition technique for high-resolution imaging. Particle distribution on TEM grids takes place homogeneously and no losses occur. Suspension must be appropriate (stabilizer may induce artefacts). ESI parameters need to be optimized for each material. T2 - Final NanoDefine Outreach Event: Classification of nanomaterials according to the EU definition CY - Brüssel, Belgium DA - 19.09.2017 KW - Electrospray deposition KW - Electron microscopy KW - Nanoparticles PY - 2017 UR - http://www.nanodefine.eu/index.php/nanodefine-meetings/125-final-outreach-event-2017 AN - OPUS4-42508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Report on the Round Robin Exercise - Coated Materials T2 - Final General Meeting of the EU-GDS Network CY - Wiener Neustadt, Austria DA - 2002-03-02 PY - 2002 AN - OPUS4-1468 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Complementary methodical approach for the analysis of a perovskite solar cell layered system N2 - Loss in efficiency of perovskite solar cells may be caused by structural and/or chemical alterations of the complex layered system. As these changes might take place either in the bulk and/or on the surface of the stratified material, analytical tools addressing both key issues are selected and combined. SEM/EDX combined with XPS were chosen as appropriate methodical approach to characterise perovskite laboratory cells in depth and complementary on top, before and after light exposure. The layered perovskite system investigated here is based on glass covered with fluorine doped tin oxide (FTO), followed by three porous thin films of TiO2, ZrO2 and a thick monolithic carbon. The TiO2 film is subdivided into a dense layer covered by a porous one constituted of nanoparticles with a truncated bipyramidal shape. This layered system serves as the matrix for the perovskite. After infiltration of perovskite solution and annealing, EDX spectral maps on cross-sections of the specimen have been measured. The distribution of relevant elements – Si, Sn, Ti, Zr and C – correlates conclusively with layers visible in the acquired SEM images. Lead and iodine are distributed throughout the porous layers C, ZrO2 and TiO2. In a SEM micrograph taken of the cross-section of a sample after illumination, the glass substrate and all layers FTO, TiO2, ZrO2 as well as C are clearly identified. By EDX it was found that several weeks of ambient daylight did not change significantly the qualitative elemental composition of lead and iodine throughout the solar cell system. It was confirmed with EDX that nanoparticles identified in high-resolution SEM micrographs contain mainly Pb and I, indicating these to be the perovskite crystals. However, a time-dependent compositional and chemical altering was observed with XPS for the near-surface region of the outermost ~10 nm after two months of illumination. T2 - Microscopy & Microanalysis 2017 Meeting CY - St. Louis, MO, USA DA - 06.08.2017 KW - Thin films KW - EDX KW - XPS KW - SEM KW - Nanoparticles KW - Perovskite KW - TiO2 PY - 2017 AN - OPUS4-41664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Evaluation of particle sizing techniques for the implementation of the EC definition of a nanomaterial N2 - Many techniques are available for measuring particle size distribution. For ideal materials (spherical particles, well dispersed) it is possible to evaluate the Performance of These methods. The performance of the analytical instrumentation for the purpose of classifying materials according to EC Definition is unknown. In this work the performance of commercially available particle sizing techniques on representative NanoDefine set of real-world testing materials (RTM) and quality control materials (QCM) for the implementation of the Definition is evaluated. T2 - 4. Sitzung des wissenschaftlichen Beirats zum Themefeld Umwelt der BAM CY - BAM, Berlin, Germany DA - 13.04.2018 KW - Nanoparticles KW - Nanomaterial KW - Characterization methods KW - EU definition KW - Nanodefine PY - 2018 AN - OPUS4-44693 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - EMPIR nPSize - improved traceability chain of nanoparticle size measurements - Is a liaison to CEN/TC 352 nanotechnologies useful? N2 - The main objectives of the new EMPIR project nPSize are to establish EU capability of traceable measurement of NP size and shape, lower uncertainties of NP size measurement by developement of new nano-CRMs, new models (physical and machine learning), 3D method combination, and also by new ISO and CEN standards on accurate NP size measurement and guidance and knowledge transfer. The envisaged outcomes of the project will be presented and their suitability will be discussed to be taken over as pertinent contributions to normative projects within CEN/TC 352 Nanotechnologies. T2 - Joint Working Groups and 24th CEN/TC 352 Nanotechnologies Meetings CY - DIN, Berlin, Germany DA - 09.10.2018 KW - Nanoparticles KW - Size KW - Particle size distribution KW - Particle shape KW - Traceability KW - Standardisation KW - CEN/TC 352 Nanotechnologies PY - 2018 AN - OPUS4-46252 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Eds elemental selectivity with respect to nanoparticle analysis T2 - EMAS 2015 CY - Portoroz, Slovenia DA - 2015-05-03 PY - 2015 AN - OPUS4-33148 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Hodoroaba, Vasile-Dan A1 - Rackwitz, Vanessa T1 - A microfocus X-ray source for improved EDS and XRF analysis in the SEM N2 - A microfocus X-ray source mounted on the analysis chamber of an SEM was used to excite X-ray fluorescence spectra and to detect chemical elements with concentrations below the detection limit of the electron-excited X-ray spectra conventionally measured with SEM/EDS. An aluminium alloy and a hard material ceramics were analysed as representative examples. It is demonstrated that the combination of the three analytical methods: (1) SEM imaging for surface morphology characterisation; (2) electron-excited X-ray spectroscopy with its high spatial resolution for element analysis of inclusions or precipitates; and (3) X-ray fluorescence for the detection of elements with concentrations below 0.1 mass% considerably improves the performance of SEM/EDX analyses. KW - Scanning electron microscopy KW - Microanalysis KW - Energy-dispersive X-ray spectroscopy KW - X-ray fluorescence KW - Micro-XRF KW - Materials science PY - 2011 SN - 2043-0655 VL - 25 IS - 4 SP - 11 EP - 13 PB - Wiley CY - Chichester AN - OPUS4-23764 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Improved Deposition of Nanoparticles vy Electrospray Analaysis with SEM/TEM and EDS N2 - Although there are many experimental techniques for measuring particle sizes and size distributions, electron microscopy (EM) is still considered as the gold standard in this field, especially when it comes to particle sizes in the nanorange (1 nm – 100 nm). Furthermore, high-resolution X-ray spectroscopy (EDS) can be applied to individual nanoparticles. To be able to extract accurate information from the EM micrographs and EDS elemental maps that are representative for the material under investigation, one needs to assure the representativity of the particles as sampled on the substrate and their homogeneous spatial distribution, to avoid operator bias when selecting the imaged area. Furthermore, agglomeration should be avoided as far as possible. Several sample preparation techniques exist since a long time, the most common way being suspending the particles in a liquid and depositing them on the grid. However, this procedure includes the drying of larger solvent amounts on the substrate itself, which can affect the spatial distribution of the deposited particles. One possibility to overcome this problem is the use of an electrospray system, where the suspension of particles is sprayed onto the substrate in charged droplets that are so small that they either dry off on the substrate immediately without affecting the position of particles, or even already during their flight time to the substrate. No dedicated commercial instruments are available for the preparation of TEM grids yet, only electrostatic deposition of aerosols on TEM grids has been reported so far. To test the prototype and assess its performance, several materials have been sprayed onto TEM grids and the resulting particle distributions were compared to more traditional sample preparation strategies like the “drop on grid” method. Operation parameters such as the sample flow-rate, capillary – substrate distance, electric field strength and sampling period length have been optimised. It was found that the particles deposited by electrospray generally show a much more homogeneous spatial distribution on the substrate and a substantial increase of the number of single particles, which are much better suited to an automatic image evaluation procedure than the agglomerated particles observed otherwise. The applicability of the technique to a broad range of materials is demonstrated by various examples, but also the influence of the substrate, the choice of the particular TEM grid, on the obtained spatial particle distribution is assessed. T2 - EMAS 2017 - 15th European Workshop on MODERN DEVELOPMENTS AND APPLICATIONS IN MICROBEAM ANALYSIS and IUMAS-7 Meeting CY - Konstanz, Germany DA - 07.05.2017 KW - Electrospray deposition KW - TEM grids KW - Nanoparticles KW - Agglomeration PY - 2017 AN - OPUS4-40257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg T1 - Surface Analysis and Context of the New HAXPES@BAM N2 - The Competence Centre nano@BAM is presenting a new X-ray Photoelectron Spectrometer – the HAXPES (XPS at hard energy) – for researching advanced materials at the nanoscale. With HAXPES detailed chemical information can now be gained not only from the first outermost nanometres of the sample surface, but also from deeper regions. Top international experts will share their knowledge and key findings on how to utilise HAXPES for exploring the surface of various advanced materials. Following the lectures, we will show you a short demo of the new instrument and answer your questions. T2 - Inauguration of the HAXPES@BAM - A new Hard-X-Ray Photoelectron Spectrometer CY - Online meeting DA - 25.01.2022 KW - XPS KW - HAXPES KW - Nano@BAM KW - Surface Analysis PY - 2022 UR - https://www.bam.de/Content/EN/Events/2022/2022-01-25-hapex.html AN - OPUS4-54377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Nanoanalytik-Aktivitäten @ BAM N2 - In dieser Präsentation werden Aktivitäten im Bereich der 'nano'-Charakterisierung bei der BAM vorgestellt. Beispiele von F&E-Projekten und -Kooperationen im nano-Analytik-Bereich bei der BAM werden genannt. Thematische Kooperations-Möglichkeiten zwischen BAM und dem Netzwerk NanoAnalytik und -Messtechnik in der Produktion werden diskutiert. T2 - Treffen des Netzwerkes NanoAnalytik und -Messtechnik CY - Berlin, Germany DA - 06.11.2018 KW - Nanoanalytik KW - Nano-Projekte KW - Nano-Kompetenzzentrum KW - Nano-Charakterisierung PY - 2018 UR - https://www.nanoinitiative-bayern.de/nanoanalytik/ AN - OPUS4-46563 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wäsche, Rolf A1 - Hartelt, Manfred A1 - Hodoroaba, Vasile-Dan T1 - Analysis of nanoscale wear particles from lubricated steel-steel contacts N2 - A new method for sampling wear particles directly from the lubricant reservoir has been developed and applied successfully for analyzing wear particles by high-resolution scanning electron microscopy in transmission mode having coupled energy-dispersive X-ray spectroscopy. The lubricated tribological testing was carried out with fully formulated as well as with non-formulated synthetic base oil. It was possible to analyze individual particles with dimensions as small as about 5–30 nm which are likely the 'primary' wear particles. A majority of the particles, however, are agglomerated and, thus, lead to the formation of larger agglomerates of up to a few micrometers. Chemical analysis led to the conclusion that most of the observed particles generated in formulated oil, especially the larger ones, are composed of the additives of the lubricant oil. In non-formulated base oil, the primary particles are of similar dimensions but contain only iron, chromium and oxygen, but most likely stem from the mating materials. This finding points to the fact that the main wear mechanism under lubricated conditions with fully formulated oil is more like a continuous shearing process rather than a catastrophic failure with the generation of larger primary particles. When the oil is non-formulated, however, several wear mechanisms act simultaneously and the wear rate is increased significantly. Generated larger primary particles are milled down to the nanoscale. When the oil is fully formulated, wear mainly takes places at the additive layer or tribofilm; thus, the steel surface is protected. KW - Particle KW - Wear particle analysis KW - Lubricated contact KW - Bearing steel KW - Nanoscale T-SEM KW - Nanoscale EDX analysis PY - 2015 DO - https://doi.org/10.1007/s11249-015-0534-1 SN - 1023-8883 SN - 1573-2711 VL - 58 IS - 3 SP - 49-1 - 49-10 PB - Springer Science Business Media B.V. CY - Dordrecht AN - OPUS4-33525 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Organic surface modification and analysis of TiO2 nanoparticles for self-assembly in multiple layers N2 - Parameters of TiO2 coatings can greatly influence their final performance in largescale applications such as photocatalytic measurements, orthopedic and/or dental prostheses, cell cultures, and dye-sensitized solar cells. From different film deposition procedures, self-assembly of TiO2 NPs in multiple layers was selected for systematic characterization. EDX, AES and ToF-SIMS analysis have been carried out in order to evaluate the functionalization of several types of TiO2 NPs differing in size, shape and surface area. T2 - Microscopy & Microanalysis 2017 Meeting CY - St. Louis, MO, USA DA - 06.08.2017 KW - TiO2 KW - Nanoparticles KW - EDX KW - ToF-SIMS KW - XPS KW - Auger electron spectroscopy KW - Functionalization PY - 2017 AN - OPUS4-41662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Morphological and Chemical Composition of a CH3NH3PbI3/TiO2 Solar Cell Layered System N2 - Manufacturing of new perovskite layered solar cells with constant high light conversion efficiency over time may be hampered by the loss of efficiency caused by structural and/or chemical alterations of the complex layered system. SEM/EDX combined with XPS were chosen as an appropriate methodical approach to characterize perovskite laboratory cells in depth and at surface, before and after light exposure. The layered perovskite system investigated here is based on glass covered with fluorine doped tin oxide (FTO), followed by thin films of TiO2, ZrO2 and a thick monolithic carbon. TiO2 film is subdivided into a dense layer covered by porous one constituted of nanoparticles (NPs) of truncated bipyramidal shape. This layered system serves as the matrix for the perovskite. EDX spectral maps on cross-sections of specimen have shown that Pb and I are distributed homogeneously throughout the porous layers C, ZrO2 and TiO2. SEM/EDX data show that 20 weeks of ambient daylight did not change significantly the indepth distribution of the elemental composition of Pb and I throughout the entire solar cell system. It was confirmed with EDX that NPs identified in high-resolution SEM micrographs contain mainly Pb and I, indicating these to be the perovskite crystals. However, a compositional and chemical altering began in the near-surface region of the outermost ~10 nm after 2 months of illumination which was observed with XPS. T2 - 17th European Conference on Applications of Surface and Interface Analysis ECASIA 2017 CY - Montpellier, France DA - 24.09.2017 KW - Perovskite KW - Solar cells KW - SEM/EDX KW - XPS KW - Layer analysis PY - 2017 AN - OPUS4-42657 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rossi, Andrea A1 - Alladio, Eugenio A1 - Drobne, Damjana A1 - Hodoroaba, Vasile-Dan A1 - Jurkschat, Kerstin A1 - Kononenko, Veno A1 - Madbouly, Loay Akmal A1 - Mrkwitschka, Paul A1 - Novak, Sara A1 - Radnik, Jörg A1 - Saje, Špela A1 - Santalucia, Rosangela A1 - Sordello, Fabrizio A1 - Pellegrino, Francesco T1 - Development of a one-pot synthesis of rGO in water by optimizing Tour’s method parameters N2 - Since its first synthesis in 2004, graphene has been widely studied and several different synthesis methods has been developed. Solvent exfoliation of graphite and the reduction of graphene oxide previously obtained through graphite oxidation are the most employed. In this work, we exploited synthesis conditions of a method usually employed for obtaining graphene oxide (the Tour’s method) for directly obtaining a very poorly oxidised material with characteristics like reduced graphene oxide. For the first time, a one-pot synthesis of reduced graphene oxide (rGO) is reported avoiding the use of a post-synthesis chemical or thermal reduction of the graphene oxide that requires further reagents, heat and time. KW - Graphene KW - 2D-materials KW - Tour's method KW - rGO KW - One-pot synthesis PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-611827 DO - https://doi.org/10.1038/s41598-024-73606-2 SN - 2045-2322 VL - 14 SP - 1 EP - 10 PB - Springer Nature CY - London AN - OPUS4-61182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chemello, Giovanni A1 - Despotelis, Konstantinos A1 - Paton, Keith A1 - Clifford, Charles A A1 - Pollard, Andrew A1 - Radnik, Jörg A1 - Hodoroaba, Vasile-Dan T1 - Approaches for the measurement of lateral dimensions of graphene oxide flakes using scanning electron microscopy N2 - There is a practical need, especially from the industrial community, to accurately measure the size and shape of graphene oxide (GO) flakes of commercial origin, in a reliable, simple, and unambiguous way. The sample preparation is a decisive step to obtain a homogeneous distribution of flakes on a substrate, which is suitable for image analysis. A certain level of inhomogeneity was still found but could be accepted for the purpose of this lateral size measurement study. A measurement procedure for Scanning Electron Microscopy (SEM) including sample preparation, measurement, image analysis and reporting was developed and validated to be applied for the lateral size analysis of “real-world” 2D flakes. Samples were produced for analysis by drop casting GO dispersions onto Si/SiO2 substrates. After SEM imaging, the images were analysed using two approaches to derive size and shape parameters. The influence of different operators has been evaluated. A maximum difference of 10% for the size descriptor and 2% for shape descriptor was found for both image analysis approaches when different samples of the same source material are measured and analysed by the same operator, hence indicating variability caused by sample preparation and analysing different sample areas. When different laboratories/operators perform the image analysis on exactly the same images and same flakes, the deviation found for the size descriptor is 2% and 4.6% corresponding to the two approaches applied, while no difference in the shape descriptor is observed. KW - Graphene oxide KW - SEM KW - Lateral dimension KW - Standardisation KW - Imaging PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625070 DO - https://doi.org/10.1088/2632-959X/adae28 VL - 6 IS - 1 SP - 1 EP - 11 PB - IOP Publishing AN - OPUS4-62507 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Madbouly, Loay Akmal A1 - Mrkwitschka, Paul A1 - Stockmann, Jörg Manfred A1 - Jones, Elliot A1 - Radnik, Jörg A1 - Hodoroaba, Vasile-Dan T1 - Comparative Elemental Analysis of Commercial Functionalized Graphene Nanoplatelets Along the Production Chain With X‐Ray Photoelectron and Energy‐Dispersive X‐Ray Spectroscopy N2 - Graphene has been commercialized for over a decade, primarily in the form of suspensions and inks. In this study, we investigate the properties of graphene nanoplatelets (GNPs) and their functionalized derivatives, incorporating fluorine or nitrogen as functional groups (FG). The analysis was conducted on three forms, that is, powders, suspensions, and inks, using X‐ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) with energy‐dispersive X‐ray spectroscopy (EDX). The objective of this work is to establish a rapid and comprehensive systematic approach for elemental analysis of commercial functionalized graphene, which can be used for quality control. Functionalization is employed to tailor the material's physical and chemical properties. In our study, graphene samples, functionalized with fluorine or ammonia in a plasma reactor, were investigated. Both XPS and EDX were applicable for all three forms and showed, in general, similar trends between the three forms, so that both XPS and EDX can be used for quality control of GNPs along the production chain. KW - Commercial graphene KW - Functionalized graphene KW - Graphene inks KW - SEM/EDS KW - XPS PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625752 DO - https://doi.org/10.1002/sia.7386 SN - 1096-9918 SP - 1 EP - 7 PB - Wiley AN - OPUS4-62575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - John, Elisabeth A1 - Weise, Matthias A1 - Radnik, Jörg A1 - Stockmann, Jörg Manfred A1 - Lange, Thorid A1 - Sahre, Mario A1 - Hodoroaba, Vasile-Dan T1 - Towards a New Reference Material—Analytical Challenges in Examining High-Entropy Alloy Thin Films N2 - A new high-entropy alloy (HEA) consisting of titanium, chromium, manganese, iron, and nickel was deposited as a thin-film on silicon substrates using magnetron sputtering from a novel segmented target composed of metal stripes. This material was explored with the goal to create a new reference material for surface analysis and evaluation of complex composite materials. The film's morphology was initially characterized by scanning electron microscopy (SEM), followed by crystallographic analysis using X-ray diffraction (XRD) and selected area electron diffraction (SAED). The two-dimensional compositional homogeneity was assessed using a combination of scanning and transmission electron microscopy (TEM) with energy-dispersive spectroscopy (EDS), X-ray fluorescence (XRF), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The in-depth chemical composition was further analysed using ToF-SIMS and Auger electron spectroscopy (AES). Our findings demonstrate that it is possible to produce thin HEA films with a homogeneous in-depth composition from a segmented target. Notably, despite the fixed composition of the target, we were able to vary the HEA's composition by exploiting inhomogeneities within the magnetrons sputter plasma. Additionally, we successfully created HEA films with significant compositional gradients. T2 - ECASIA CY - Gothenburg, Sweden DA - 10.06.2024 KW - Reference material KW - High-entropy alloy KW - Thin-films PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625777 DO - https://doi.org/10.1002/sia.7387 SN - 1096-9918 SP - 1 EP - 8 PB - Wiley AN - OPUS4-62577 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Depth profilling of layered samples by Glow Discharge Optical Emission Spectroscopy (GD-OES) T2 - AIST-BAM Symposium on Material Surface Technology in TWIN Institute Programme; AIST Tsukuba Research Centre CY - Tsukuba, Japan DA - 2003-02-18 PY - 2003 AN - OPUS4-4325 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Survey on the Suitability of Coatings Containing Hydrogen as Lyared CRM for GDS T2 - Colloquium Spectroscopicum Internationale (CSI XXXIII) CY - Granada, Spain DA - 2003-09-07 PY - 2003 AN - OPUS4-5005 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rackwitz, Vanessa A1 - Procop, M. A1 - Bjeoumikhova, S. A1 - Panne, Ulrich A1 - Hodoroaba, Vasile-Dan T1 - A routine procedure for the characterisation of polycapillary X-ray semi-lenses in prallelising mode with SEM/EDS N2 - The accurate knowledge of the properties of polycapillary X-ray semi-lenses has a significant influence on the quantitative results in a widespread field of applications involving microfocus X-ray beams. A routine procedure for the characterisation of a polycapillary X-ray semi-lens with a scanning electron microscope (SEM) having attached an energy dispersive spectrometer (EDS) is presented in this paper. A key issue of the procedure consists of fitting the semi-lens in front of the EDS for spectra acquisition. Relevant semi-lens parameters such as focal distance, full width at half maximum (FWHM) of the acceptance area, and transmission are determined in parallelising mode of the semi-lens. Special attention has been paid to the calculation of the transmission. KW - Polycapillary X-ray optics KW - Semi-lens KW - Parallelising mode KW - SEM KW - EDS KW - Acceptance area KW - FWHM KW - Transmission KW - Focal distance KW - XRF PY - 2011 DO - https://doi.org/10.1039/c0ja00135j SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 3 SP - 499 EP - 504 PB - Royal Society of Chemistry CY - London AN - OPUS4-23555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rades, Steffi A1 - Hodoroaba, Vasile-Dan A1 - Ortel, Erik A1 - Wirth, Thomas A1 - Borghetti, P. A1 - Garcia, S. A1 - Gómez, E. A1 - Blanco, M. A1 - Alberto, Gabriele A1 - Martra, G. T1 - Organic surface modification and analysis of titania nanoparticles for self-assembly in multiple layers N2 - Parameters of TiO2 coatings can greatly influence their final performance in largescale applications such as photocatalytic measurements, orthopedic and/or dental prostheses, cell cultures, and dye-sensitized solar cells. From different film deposition procedures, self-assembly of TiO2 NPs in multiple layers was selected for systematic characterization. EDX, AES and ToF-SIMS analysis have been carried out in order to evaluate the functionalization of several types of TiO2 NPs differing in size, shape and surface area. KW - TiO2 KW - Nanoparticles KW - Surface modification KW - Functionalization PY - 2017 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/organic-surface-modification-and-analysis-of-titania-nanoparticles-for-selfassembly-in-multiple-layers/66776A4CA7FD059CE39041A99A922D90 DO - https://doi.org/10.1017/S1431927617010029 SN - 1431-9276 SN - 1435-8115 VL - 23 IS - S1 (July) SP - 1872 EP - 1873 PB - Cambridge University Press CY - New York, NY, U.S.A. AN - OPUS4-42457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Hodoroaba, Vasile-Dan A1 - Bjeoumikhov, A. A1 - Wedell, R. A1 - Warrikhoff, A. T1 - Improvements of the low-energy performance of a micro-focus x-ray source for XRF analysis with the SEM N2 - X-ray Fluorescence (XRF) with a scanning electron microscope (SEM) is a valuable completion of the analytical capabilities of SEMs. Small and compact micro-focus x-ray sources are mounted to the microscope chamber, and the x-ray spectra are monitored with conventional EDS systems. Up to now the x-ray tubes used for the micro-focus x-ray sources are equipped with beryllium windows about 100 µm thick. The poly-capillary x-ray lenses have their transmission maximum at photon energies around 10 keV. It drops down in both low- and high-energy ranges. Hence, L-radiation from an Mo or Rh target will be strongly attenuated, and the excitation of fluorescence in the soft x-ray range becomes very ineffective. A new micro-focus x-ray source was developed. It is characterised by a lower self-absorption in the tube target, thin beryllium windows and an x-ray optics having a large distance between its foci and the maximum of transmission at about 5 keV. Thus K line fluorescence of light elements becomes effectively excited by the L-radiation from Mo or Rh tube targets. The detection limit for sodium oxide in glass was found to be below 1 mass%. KW - Micro-focus-XRF KW - X-ray tube KW - X-ray optics KW - SEM PY - 2009 DO - https://doi.org/10.1002/xrs.1159 SN - 0049-8246 VL - 38 IS - 4 SP - 308 EP - 311 PB - Wiley CY - Chichester AN - OPUS4-19583 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Terborg, R. A1 - Hodoroaba, Vasile-Dan A1 - Falke, M. A1 - Käppel, A. T1 - On the characterization of the geometrical collection efficiency of modern EDS systems N2 - To compare the performance of different energy dispersive X-ray spectrometers (EDS), it is important to define characteristic spectrometer parameters. The ISO 15632 standard defines parameters like energy resolution as FWHM for the Kα lines of carbon, fluorine and manganese. The quantum efficiency, which is the ratio of the detected photons divided by the number of incoming photons for different energies, is another significant spectrometer property. It is important for the light element and low energy line detection sensitivity as well as for higher photon energies above 10 keV. A striking EDS feature, provided and marketed by many manufactures, is the active area of the detector, although actually, the solid angle available for photon collection is the more relevant geometrical parameter. It is defined as: Ω = A /r2 with A being the active area of a spherical detector and r being the distance between the point of the radiation origin and the center of the surface of the active detector chip. A more accurate calculation should be used for large flat detector areas. One should note that the solid angle Ω is not an intrinsic spectrometer property. It can only be defined for a specific detector in combination with a specific system (e.g. SEM, EPMA or TEM). Thus, the minimal possible distance r is determined by the particular geometry e.g. a possible interference with the pole piece or other detectors/components in the chamber of a microscope. New EDS technologies use e.g. integrated SDD chips or inclined chips in thinner detector fingers which can be placed closer to the sample with the final result of larger real solid angles. Therefore, the knowledge of the real solid angle is one of the crucial parameters of an EDS microscope combination. A straightforward way to estimate the real solid angle is to simply determine A and r. If respective data are not provided by the manufacturer, this approach can be difficult. KW - EDS KW - EDX KW - Geometrical collection efficiency KW - Solid angle PY - 2014 DO - https://doi.org/10.1017/S1431927614007454 SN - 1431-9276 SN - 1435-8115 VL - 20 IS - Suppl. S 3 SP - 1144 EP - 1145 PB - Cambridge University Press CY - New York, NY AN - OPUS4-31388 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Uncertainties in Secondary Fluorescence Correction in EPMA N2 - Secondary fluorescence is an inevitable effect that has to be taken into account in any algorithm for quantitative electron probe microanalysis (EPMA) as an additional correction. Moreover, secondary fluorescence worsens spatial resolution of EPMA, as discussed once more in two recent papers. Secondary fluorescence is excited both by characteristic radiation and by the X-ray continuum. In most cases the correction is small. There are, however, cases, e.g. the determination of low heavy metal concentration in a light matrix, where the contribution of secondary fluorescence exceeds 10% of the measured X-ray line intensity. For secondary fluorescence correction the measured X-ray line intensity has to be divided by the correction factor (1+I_flchar/I_p +I_flcont/I_p )≈(1+I_flchar/I_p )(1+I_flcont/I_p ) in order to get those intensity I_p, which is excited only by the primary electrons and enables the determination of specimen composition. I_flchar and I_flcont mean the calculated characteristic and continuums fluorescence intensities. In order to get the intensity of fluorescence radiation, the absorption of the exciting radiation in the specimen, the photoionization probability and the self-absorption of the emitted line must be calculated. This can be performed in a straightforward way. The critical quantity is the X-ray yield of the exciting atoms in case of fluorescence by characteristic radiation and the bremsstrahlung yield of the specimen in case of continuum fluorescence. In the former case it is reasonable to apply the same physical model to calculate I_flchar and I_p. T2 - Microscopy & Microanalysis 2019 CY - Portland, OR, USA DA - 03.08.2019 KW - EPMA KW - Secondary fluorescence KW - Uncertainties KW - X-ray spectrometry KW - Fluorescence correction PY - 2019 AN - OPUS4-48673 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - New reference material candidates for traceable size measurement of non-spherical nanoparticles N2 - New model nanoparticles with well-controlled shape were synthesized within the EMPIR project nPSize - Improved traceability chain of nanoparticle size measurements. Their systematic characterization takes place by the traceable methods scanning/transmission electron microscopy, atomic force microscopy and small angle X-ray scattering. Following reference nanoparticle candidates are under investigation with respect to their homogeneity and stability: titania nanoplatelets (10-15 nm x 50-100 nm), titania bipyramides (~60 nm x 40 nm), titania acicular particles (100 nm x 15-20 nm; aspect ratio 5.5/6), gold nanorods (~10 nm x 30 nm), and gold nanocubes (~55 nm x 55 nm x 55 nm). T2 - HyMET Workshop on optical surface analysis methods for nanostructured layers CY - Berlin, Germany DA - 10.10.2019 KW - Nanoparticles KW - Reference materials KW - Traceability KW - Particle size distribution PY - 2019 AN - OPUS4-49285 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E.B.M. A1 - Griepentrog, Michael A1 - Dück, Alexander A1 - Beck, Uwe T1 - Round Robin exercise: Coated materials for glow discharge spectroscopy N2 - A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, Ti–N layer and V–N layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (‘GDS-Net’). KW - Coated/Layered Reference Materials KW - Nitrides KW - Multilayer KW - GDS KW - Round Robin PY - 2006 DO - https://doi.org/10.1039/B513426A SN - 0267-9477 SN - 1364-5544 VL - 21 IS - 1 SP - 74 EP - 81 PB - Royal Society of Chemistry CY - London AN - OPUS4-11762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shimizu, K. A1 - Habaki, H. A1 - Wirth, Thomas A1 - Hodoroaba, Vasile-Dan T1 - New Development of Surface Analysis from a Standpoint of Users (1)DS"rf-GDOES" responding to needs for short time, high accuracy, diversified regions, and low cost KW - Atomic beam spectroscopy KW - Emission analysis KW - Cathode sputtering KW - Emission spectroscopy PY - 2004 SN - 0452-2834 VL - 52 IS - 8 SP - 72 EP - 75 PB - Nikkan kogyo shinbunsha CY - Tokyo AN - OPUS4-14523 LA - jpn AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Characterization of nanoparticles by means of high-resolution SEM/EDS T2 - EMAS 2015 - 14th European Workshop on Modern Developments and applications in microbeam analysis CY - Portoroz, Slovenia DA - 2015-05-03 PY - 2015 AN - OPUS4-33250 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hodoroaba, Vasile-Dan ED - Hodoroaba, Vasile-Dan T1 - Liaison Report from ISO/TC 202 'Microbeam Analysis' to ISO/TC 229 'Nanotechnologies' N2 - Liaison activities within ISO/TC 202 'Microbeam Analysis' which are relevant to ISO/TC 229 'Nanotechnologies' are reported acoording to the structure defined by ISO/TC229 Nanotechnologies Liaisons Coordination Group (NLCG): new standards/documents, coordination issues, and further detailed specific information, e.g. publications, events, comments. KW - ISO/TC 229 Nanotechnologies KW - ISO/TC 202 Microbeam Analysis KW - Standardisation PY - 2023 SP - 1 EP - 3 CY - ISO, Geneva, CH AN - OPUS4-58986 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan A1 - Rauscher, H. T1 - Role of the volume specific surface area in the NanoDefine decision flow scheme N2 - In this lecture the VSSA concept is explained, and VSSA as measured by BET. Results of the NanoDefine evaluation based on selected examples on real-world materials are presented. Recommendations for consideration of the VSSA concept for the implementation of the EC definition of nanomaterial for powder materials are given. T2 - Final Outreach Event “Classification of nanomaterials according to the EU definition” CY - Brüssel, Belgium DA - 19.09.2017 KW - Volume specific surface area (VSSA) KW - Nanomaterial KW - Nanomaterial classification KW - BET PY - 2017 AN - OPUS4-42391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Surface and Microbeam Analytical Methods @BAM N2 - An overview of the activities in the field of surface and microbeam analysis at BAM-6.1 is given with focus on physico-chemical characterization at the nanoscale. Ideas of potential joint activities are presented: structural and chemical analysis of graphene, deposition techniques for nanoparticles, EBSD on steel for a broader range of methods, instruments and types of steel, soft X-ray Analysis of low-Z materials, analysis of mesoporous thin films, etc. T2 - BAM-IFW Workshop CY - Dresden, Germany DA - 28.03.2019 KW - PC characterisation KW - Nanoscale KW - Nanoparticles PY - 2019 AN - OPUS4-47860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Terborg, R. A1 - Hodoroaba, Vasile-Dan A1 - Falke, M. A1 - Käppel, A. ED - Hozak, P. T1 - Characterization of EDS systems with respect to the geometrical collection efficiency T2 - IMC 2014 - 18th International microscopy congress CY - Prague, Czech Republic DA - 07.09.2014 KW - EDS KW - EDX KW - Geometrical collection efficiency KW - Solid angle PY - 2014 SN - 978-80-260-6720-7 SP - IT-5-P-1533, 1-2 AN - OPUS4-31945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dumit, Verónica I. A1 - Furxhi, Irini A1 - Nymark, Penny A1 - Afantitis, Antreas A1 - Ammar, Ammar A1 - Amorim, Monica J. B. A1 - Antunes, Dalila A1 - Avramova, Svetlana A1 - Battistelli, Chiara L. A1 - Basei, Gianpietro A1 - Bossa, Cecilia A1 - Cimpan, Emil A1 - Cimpan, Mihaela Roxana A1 - Ciornii, Dmitri A1 - Costa, Anna A1 - Delpivo, Camilla A1 - Dusinska, Maria A1 - Fonseca, Ana Sofia A1 - Friedrichs, Steffi A1 - Hodoroaba, Vasile-Dan A1 - Hristozov, Danail A1 - Isigonis, Panagiotis A1 - Jeliazkova, Nina A1 - Kochev, Nikolay A1 - Kranjc, Eva A1 - Maier, Dieter A1 - Melagraki, Georgia A1 - Papadiamantis, Anastasios G. A1 - Puzyn, Tomasz A1 - Rauscher, Hubert A1 - Reilly, Katie A1 - Jiménez, Araceli Sánchez A1 - Scott‐Fordsmand, Janeck J. A1 - Shandilya, Neeraj A1 - Shin, Hyun Kil A1 - Tancheva, Gergana A1 - van Rijn, Jeaphianne P. M. A1 - Willighagen, Egon L. A1 - Wyrzykowska, Ewelina A1 - Bakker, Martine I. A1 - Drobne, Damjana A1 - Exner, Thomas E. A1 - Himly, Martin A1 - Lynch, Iseult T1 - Challenges and Future Directions in Assessing the Quality and Completeness of Advanced Materials Safety Data for Re‐Usability: A Position Paper From the Nanosafety Community N2 - Ensuring data quality, completeness, and interoperability is crucial for progressing safety research, Safe‐and‐Sustainable‐by‐Design approaches, and regulatory approval of nanoscale and advanced materials. While the FAIR (Findable, Accessible, Interoperable, and Re‐usable) principles aim to promote data re‐use, they do not address data quality, essential for data re‐use for advancing sustainable and safe innovation. Effective quality assurance procedures require (meta)data to conform to community‐agreed standards. Nanosafety data offer a key reference point for developing best practices in data management for advanced materials, as their large‐scale generation coincided with the emergence of dedicated data quality criteria and concepts such as FAIR data. This work highlights frameworks, methodologies, and tools that address the challenges associated with the multidisciplinary nature of nanomaterial safety data. Existing approaches to evaluating the reliability, relevance, and completeness of data are considered in light of their potential for integration into harmonized standards and adaptation to advance material requirements. The goal here is to emphasize the importance of automated tools to reduce manual labor in making (meta)data FAIR, enabling trusted data re‐use and fostering safer, more sustainable innovation of advanced materials. Awareness and prioritization of these challenges are critical for building robust data infrastructures. KW - Advanced materials KW - Safety data KW - Re-usability KW - Nanosafety KW - SSbD KW - FAIR KW - Standardisation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652918 DO - https://doi.org/10.1002/adsu.202500567 SN - 2366-7486 SP - 1 EP - 18 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65291 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Analysis of Fluorine Traces in TiO2 Nanoplatelets by SEM/EDX, AES and TOF-SIMS N2 - The synthesis of TiO2 nanoplatelets with fluorine-containing reactants is carried out using Ti (IV) butoxide as precursor and concentrated HF as shape controller, the final product requires a working up in order to eliminate or at least to reduce the amount of residual fluorides, which is realized here by well-defined thermal treatment. Qualitative investigation of the bulk elemental composition by means of EDX of TiO2 nanoparticles (NPs) has identified fluorine in case of the as-synthesized samples. EDX spectra of thermally treated products exhibit either a fluorine content close to the limit of detection. The latter holds also true for the reference sample, TiO2 NPs of bipyramidal shape and prepared by a different synthesis route. For differentiation whether fluorine is present in the bulk or at the surface of the TiO2 nanoplatelets, top-surface sensitive AES and ToF-SIMS has been applied. Secondary ions of fluorine are detected in ToF-SIMS spectra of all samples, but could be roughly quantified by measurement of same reference sample as for EDX, namely TiO2 nano-bipyramids. This revealed that the amount of fluorine within1 nm depth beneath the surface is reduced in the thermally treated specimen compared to the raw product down to a content about as low as in the reference sample. AES allows analyzing analysis of the first few nanometers from the top-surface of individual NPs by point analysis. An F KLL peak has been detected at the surface of samples of as-prepared TiO2 nanoplatelets under optimized measurement conditions, but was not detectable after their calcination, which is in agreement with ToF-SIMS results. Moreover, high resolution AES on single TiO2 nanoplatelets elucidated that the surface atomic layers surrounding the TiO2 nanopaltelet contain fluorides before thermal treatment of the NPs. T2 - 17th European Conference on Applications of Surface and Interface Analysis ECASIA 2017 CY - Montpellier, France DA - 24.09.2017 KW - Titania KW - Nanoparticles KW - Fluorine KW - SEM/EDX KW - Auger Electron Spectroscopy KW - Nanoplatelets PY - 2017 AN - OPUS4-42656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Unger, Wolfgang A1 - Jenett, H. A1 - Hoffmann, V. A1 - Hagenhoff, B. A1 - Kayser, S. A1 - Wetzig, K. T1 - Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS N2 - The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as “HFM” in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information. KW - rf-Glow discharge KW - HFM plasma SNMS KW - Non-conductive layered samples KW - Depth resolution KW - Crater shape KW - ToF-SIMS PY - 2001 DO - https://doi.org/10.1016/S0169-4332(01)00259-8 SN - 0169-4332 SN - 1873-5584 VL - 179 IS - 1-4 SP - 30 EP - 37 PB - North-Holland CY - Amsterdam AN - OPUS4-6882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Technique evaluation and method development for the characterization and classification of materials according to the EC nano-definition T2 - Public NanoDefine Workshop: Characterization and classification of materials according to the EC nano-definiton CY - Brussels, Belgium DA - 2015-06-17 PY - 2015 AN - OPUS4-33883 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - On the Characterization of the Geometrical Collection Efficiency of Modern EDS Systems T2 - Microscopy and Microanalysis M&M 2014 CY - Hartford, CT, USA DA - 2014-08-02 PY - 2014 AN - OPUS4-31468 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fernandez-Poulussen, D. A1 - Hodoroaba, Vasile-Dan T1 - Holistic, reliable and practical Characterization Framework for Graphene Family Materials, a correlated approach including Imaging based techniques N2 - ACCORDs is an Horizon Europe project working in the development of an imaging-based characterization framework (ACCORDs framework) for the holistic correlative assessment of Graphene Family Materials (GFMs) as a representative of 2D nanomaterials (NMs) to assess and predict 2D NMs health and environmental risks. The ACCORDs framework will operationalise safe and sustainable by design (SSbD) strategies proposed in past or ongoing H2020 projects or within OECD by correlating low-, medium-, and high-resolution physico-chemical-biological imaging-based methods with non-imaging methods in a tiered approach. ACCORDs will deliver the ACCORDs framework and user guidance, new imaging-based characterisation methods, reference in vitro tests, new reference 2D NMs for different matrices, a new minimum information reporting guideline for FAIR data sharing and reuse of images as well as an atlas with reference images for diagnostics of compromised safety of GFMs/GFM products. The new guidelines and standard proposals will be submitted to standardisation bodies to allow creation of regulatory ready products. The novelty of ACCORDs is in translating the principles of medical imaging-based diagnostics to 2D material hazard diagnostics. ACCORDs will accelerate industrial sectors in the area of aviation, marine construction, drone production, flexible electronics, photovoltaics, photocatalytics and print inks-based sensors. The value ACCORDs proposes to the graphene industry are practical, easy, imaging-based tools for GFM quality monitoring next to the production line with a possibility to be correlated with advanced highresolution imaging characterization methods in case hazard i.e. deviation from controls (benchmark values) are diagnosed. The ACCORDs framework and tools will contribute to the European Green Deal by addressing the topic: “Graphene: Europe in the lead” and to a new European strategy on standardization, released on 2nd February, 2022. T2 - MaterialsWeek 2024 CY - Limassol, Cyprus DA - 17.06.2024 KW - Graphene KW - Graphene-related 2D materials KW - SSbD KW - Imaging KW - ACCORDs PY - 2024 AN - OPUS4-60573 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Towards Standardised Procedures for Morphology Measurement of 2D-Materials by Imaging N2 - The industry uptake of graphene-related 2D materials (GR2M) material increases, and international standardization is critical to enable commercialization. Reliable, accurate, and reproducible measurements are important due to the multiple production routes and producers of the material to maintain quality in manufacture. Several standards are under development within ISO/TC 229 ‘Nanotechnologies’, i.e. ISO/AWI TS 23879 “Structural characterization of graphene oxide flakes: thickness and lateral size measurement using AFM and SEM” or ISO DTS 23359 “Chemical characterization of graphene in powders and suspensions”, which focus on determining the dimensional and chemical properties of GR2M. Interlaboratory comparisons are required to develop best practice and understand the associated measurement uncertainties. In this contribution challenges and solutions for the accurate measurement of the lateral size of GR2M will be discussed based on the results of a recently completed interlaboratory comparison organized under the pre-standardisation platform of VAMAS (www.vamas.org/twa41/documents/2023_vamas_twa41_project13_GO_SEM.pdf). Aspects related to sample preparation, measurement conditions, and image analysis with different approaches to extract the corresponding size and shape descriptors will be presented. A discussion on the measurement uncertainty budget associated to the final result will be also included. T2 - Graphene Week 2025 CY - Vicenza, Italy DA - 22.09.2025 KW - Graphene-related 2D materials (GR2M) KW - Interlaboratory comparison KW - VAMAS KW - Lateral size KW - ISO/TC 229 Nanotechnologies PY - 2025 AN - OPUS4-64250 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knigge, Xenia A1 - Guo, Z. A1 - Valsami-Jones, E. A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg T1 - Influence of Sterilization on the Surface of Nanoparticles Studied with XPS / HAXPES in Comparison to SEM / EDS N2 - Nanosafety is becoming increasingly important as nanomaterials are widely used in industrial processes and consumer products. For nanotoxicity measurements prior sterilization of the samples is necessary, but as structure activity relationships are made with properties of pristine particles, the question arises, if the sterilization process has an impact on the physico-chemical properties of nanoparticles and thus on the biological behavior. This question will be addressed in this talk. For this purpose, results from SEM and EDS measurements are combined with those of a novel lab-based HAXPES spectrometer in order to obtain a more complete picture. At the end, an influence of sterilization will be evident, which indicates a restructuring of the nanoparticles owing to sterilization. T2 - Microscopy & Microanalysis 2022 CY - Portland, USA DA - 31.07.2022 KW - XPS KW - HAXPES KW - SEM KW - EDS KW - Nanoparticles PY - 2022 DO - https://doi.org/10.1017/S1431927622004287 VL - 28 SP - 986 EP - 988 PB - Cambridge University Press AN - OPUS4-55352 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eggert, Claudia A1 - Hodoroaba, Vasile-Dan T1 - Welcome and Introduction N2 - Nanotechnology has emerged over the past decade as a key field involving the design, characterization, production, and application of materials, structures, devices, and systems at the nanometer scale. Due to their large specific surface area and significant surface chemistry, nanomaterials offer enhanced material properties and product functionalities. However, alongside these advancements comes the potential risk to humans and the environment. The development of nanomaterials has provided new opportunities to understand matter at the nanoscale, accelerating the creation of innovative advanced materials and devices. The expertise gained in the standardization and regulation of nanomaterials, particularly in characterizing nanoparticulate matter, should be applied to other innovative advanced materials, such as (nano)composites, 2D structures, additive manufactured materials, gels, and foams. Initial guidance for the safe-and-sustainable-by-design (SSbD) development of advanced materials during the early innovation phase has been introduced by various groups and projects. Additionally, digital material passports (DMP) and digital product passports (DPP) need to be defined and implemented uniformly across Europe. In 2024, the Innovative Advanced Materials Initiative (IAM-I) was launched by European stakeholders to contribute to a "Research and Innovation ecosystem that will significantly accelerate the time-to-market of sustainable innovative advanced materials (IAMs) and associated technologies designed for a digital circular economy." Knowledge transfer is a crucial pillar of this ecosystem, and a future IAM-I Academy could be a valuable tool. Initially, it is essential to define "education & training needs to boost Europe’s competitiveness and sovereignty within the area of IAM." T2 - Nano and Beyond - What can we learn from Nano for other Innovative Advanced Materials? CY - Online meeting DA - 04.07.2025 KW - Advance Materials KW - Nanomaterials KW - IAM-I KW - SSbD KW - DMP KW - DPP PY - 2025 UR - https://www.bam-akademie.de/kursangebot/kurs/webinar-nano-and-beyond-55.html?lang=en AN - OPUS4-63690 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - SETNanoMetro advances: Fabrication and measurement of TiO2 engineered nanoparticles N2 - The press conference on the results of the European Project FP7 constitutes a dissemination event dedicated to the production and characterization of "Shape-engineered TiO2 nanoparticles for metrology of functional properties: setting design rules from material synthesis to nanostructured devices" with the main large-scale applications in the three reference sectors: energy, health and environment. T2 - Press conference on the results of the European Project FP7 CY - Istituto Nazionale di Ricerca Metrologica (INRiM), Torino, Italy DA - 31.03.2017 KW - TiO2 KW - Nanoparticles KW - Measurement KW - Metrology KW - Shape-enegineered nanoparticles PY - 2017 AN - OPUS4-39622 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Advanced physico-chemical Characterisation & Correlation of Results with different Methods for GFMs N2 - An accurate characterisation of the morphological, structural, and chemical properties of nano and advanced materials is key for the understanding of the material functionality and constitutes the basis for future optimisation or even prediction of the product performance. Further, the correlation of the physical-chemical properties with results from biological testing leads to an understanding of the potential toxicological effects so that a minimisation of the materials risks becomes possible. The presentation will highlight with examples the importance of the selection of the relevant parameters/descriptors and particularly their measurement for the reliable characterisation of the morphology, structure, and chemistry of graphene-related 2D-materials (GR2M’s) [1-3]. One crucial aspect is also one of most challenging ones in the characterisation chain: the proper sample preparation, which shall be tailored to the accurate measurement of the defined analytical parameter. Practical examples of measurement of morphological descriptors of GR2M’s, such as equivalent circular diameter (ECD), minimum and maximum Feret, and aspect ratio with electron microscopy, or of the thickness with atomic force microscopy (AFM) will be showed, together with quantitative chemical characterisation with X-ray photoelectron spectroscopy (XPS) and, newly, with energy-dispersive X-ray spectroscopy with a scanning electron microscope (SEM/EDX) [4] by evaluating accurately the elemental content as the ratio of O/C and the composition of impurities. Another relevant, but challenging part of the characterisation of GR2M’s, particularly as the final products containing mostly low amounts of GR2M’s, is the analysis of homogeneity of the chemical composition by sensitive imaging methods. Examples of successful analysis with secondary ion mass spectrometry (SIMS), even if not quantitative, will be presented. T2 - Joint online Workshop: Harmonisation & Standardisation of Test Methods for Nano- and Advanced Materials CY - Paris, France DA - 19.06.2025 KW - Physico-chemical characterisation KW - Graphene-related 2D materials KW - OECD KW - Standardisation KW - GO flakes PY - 2025 UR - https://macrame-project.eu/macrame-meetings-workshops/ws_hamonisation_standardisation_2023/ AN - OPUS4-63557 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - (Pre)Standardisation and Metrology in Microbeam Analysis – Ongoing Activities and Opportunities N2 - The presentation addresses the current ongoing projects as well as the gaps and opportunities in microbeam analysis within ISO/TC 202 Microbeam Analysis standardisation body and in-liaison Technical Working Areas (TWAs) at the pre-standardization platform of VAMAS (Versailles Project on Advanced Materials and Standards). T2 - EMAS 2023 - 17th European Workshop on Modern Developmennts and Applications in Microbeam Analysis - General Assembly CY - Krakow, Poland DA - 07.05.2023 KW - Microbeam analysis KW - EDS KW - Electron microscopy KW - Inter-laboratory comparison KW - EBSD KW - Standardisation PY - 2023 AN - OPUS4-57483 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan T1 - Measurement of the Lateral Size of Graphene Oxide Flakes by SEM N2 - The progress of the VAMAS interlaboratory comparison Project P13 "Lateral size of graphene oxide flakes by SEM" within the Technical Working Area 41 "Graphene and Related 2D Materials" is presented. The challenges at sample preparation on substrates for accurate measurement and image analysis as well as two different analysis approaches, containing exact guidance how to measure the main descriptors for the lateral size measurement of the imaged graphene oxide flakes with Scanning Electron Microscopy are highlighted. The size and shape distributions as measured by 17 laboratories are showed expressed in size and shape descriptors extracted from SEM images by using two proposed measurement approaches. The implementation of the results into the corresponding ISO technical specification AWI/TS 23879 is discussed and planned, in relation with the AFM part. T2 - ISO/TC 229 Nanotechnologies Meeting Week CY - Stockholm, Sweden DA - 19.05.2025 KW - Graphene oxide KW - Interlaboratory comparison KW - SEM KW - Lateral size KW - VAMAS KW - ISO/TC 229 Nanotechnologies PY - 2025 AN - OPUS4-63189 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -