TY - CHAP A1 - Zscherpel, Uwe A1 - Ewert, Uwe ED - Russo, Paolo T1 - Handbook of X-ray imaging: Physics and technology N2 - Industrial Radiology is used for volumetric inspection of industrial objects. By penetration of these objects (typically weldments, pipes or castings) with X-ray or Gamma radiation the 3D-volume is projected onto a 2D image detector. The X-ray film is the oldest radiographic image detector and still in wide use in industry. The industrial X-ray film systems used today differ from these used in medicine. Medical film systems are described well in the literature, but industrial film systems not. So we start with a description of the properties and standards for industrial film systems. The requirements on image quality are defined by several standards and can be verified with different image quality indicators (IQIs). They describe the ability of the human being to detect small and low contrast indications in a noisy image background. The essential parameters for digital industrial radiology are described. Since about 30 years electronic image detectors are gradually replacing the industrial film. These detectors are based on storage phosphor imaging plates in combination with Laser scanners (“Computed Radiography”, CR) or a variety of different digital detector arrays (DDA). Typical applications of CR and DDAs are discussed as well as new possibilities by digital image processing, which is enabled by the computer based image handling, processing and analysis. KW - Industrial radiology KW - Industrial radiography KW - NDT films KW - Computed radiography KW - Digital detector arrays PY - 2018 SN - 978-1-4987-4152-1 SP - Chapter 30, 595 EP - 617 PB - CRC Press CY - Boca Raton, FL, USA AN - OPUS4-44026 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Vogel, Justus A1 - Zhang, F. A1 - Long, N.X. A1 - Nguyen, T.P. T1 - Visibility of Image Quality Indicators (IQI) by Human Observers in Digital Radiography in Dependence on Measured MTFs and Noise Power Spectra N2 - Digital radiographic images were analysed to predict the visibility of image quality indicators (IQI), based on normalized noise power spectra (NNPP) and modulation transfer function (MTF) measurements. The fixed pattern noise of some digital detectors result in different noise spectra, which influence the visibility of different IQIs, depending on the hole diameter. Studies, based on measurement of basic spatial resolution and contrast to noise ratio were performed together with presampled MTF measurements and the NNPS in dependence on the spatial frequency. Plate hole IQIs, step hole IQIs, and equivalent penetrameter sensitivity (EPS) IQIs based on ASTM E 746 were measured to verify the influence of the different parameters. Modelling of digital images was used to verify the applied numeric tools. A study has been performed for imaging plates and digital detector arrays to analyse differences. Formulas for the prediction of the visibility functions for hole type IQIs are derived. In consequence the standards for characterization and classification of computed radiography (ASTM E 2446) and radiography with DDAs (ASTM E 2597) need to be revised. T2 - 12th ECNDT 2018 CY - Gothenburg, Sweden DA - 11.06.2018 KW - Image evaluation KW - Computed radiography (CR) KW - Digital Detector Array (DDA) KW - Detail detection PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-473486 UR - www.ndt.net/?id=22967 SN - 1435-4934 VL - 23 IS - 8 SP - 1 EP - 7 PB - NDT.net CY - Kirchwald AN - OPUS4-47348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Zhang, F. A1 - Long, N.X. A1 - Phong, N. T1 - Essentielle Parameter zur numerischen Abschätzung der Sichtbarkeit von Bildgüteprüfkörpern in der digitalen Radiographie N2 - Die Voraussetzungen für die Vorhersage der Sichtbarkeit von Bildgüteprüfkörpern (BPK) wurden seit Beginn der kommerziellen Anwendung der technischen Radiographie diskutiert und in diversen nationalen und internationalen Standards festgeschrieben. Diese Fragen werden nach Einführung der digitalen Radiographie und der CT wieder neu diskutiert. Draht BPKs wurden in Deutschland seit 1935 (DIN 1915: 1935) und später in den meisten europäischen Ländern benutzt. In den USA und Frankreich wurden vorzugsweise BPKs mit Löchern verwendet (ASTM E 1025 seit 1984 oder E 1742 seit 1992 bzw. die Vorgängernorm MIL STD-543 seit 1962). Jetzt werden auch die Umrechnungsnormen zur Erkennbarkeit von Draht zu Loch-BPKs in Frage gestellt. ISO 19232-3, der französische RCCM-Kode einerseits und ASTM E 747 und ASME BPVC Section V Tab. T-276 andererseits unterscheiden sich erheblich bei den Anforderungen im Bereich hoher Wandstärken (Hochenergieradiographie). Untersuchungen dazu werden vorgestellt. Mit Einführung der digitalen Detektoren ändern sich auch die Rauschspektren. Durch die Herstellung werden insbesondere bei Speicherfolien "Rauschmuster" eingeprägt, die bei hohen Belichtungsdosen sichtbar werden. Diese veränderten Rauschspektren ergeben auch veränderte Erkennungsparameter für menschliche Bildauswerter. Hierzu wurden an ausgewählten Detektoren MTFs (presampled) und normierte Rauschspektren gemessen. Erweiterte Erkennbarkeits-Formeln zur Vorhersage der Sichtbarkeit von BPKs für Bildauswerter und erste Ergebnisse werden vorgestellt. T2 - DGZfP-Jahrestagung 2018 CY - Leipzig, Germany DA - 07.05.2018 KW - Image quality KW - Computed radiography (CR) KW - Digital Detector Array (DDA), KW - Sichtbarkeit von Anzeigen PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-473496 UR - www.ndt.net/?id=23069 VL - 2018 SP - 1 EP - 14 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-47349 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schumacher, David A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Recent developments of photon counting and energy discriminating detectors for radiographic imaging N2 - The direct detection of X-ray photons into electrical signals is enabled by usage of highly absorbing photo conducting materials (e.g. CdTe) as detection layer of an underlying CMOS semiconductor X-ray image detector. If the read-out speed is high enough (ca. 50 - 100 ns dead time) single X-ray photons can be counted and their energy measured. Read-out noise and dark image correction can be diminished. By setting energy thresholds, selected energy ranges of the X-ray spectrum can be detected or suppressed. This allows material discrimination or reduction of scattered radiation, which results in an enhanced contrast sensitivity. T2 - Far East NDT New Technology & Application Forum (FENDT) CY - Xi'an, China DA - 22.06.2017 KW - Industrial X-ray imaging KW - Photon counting KW - Energy discrimination KW - Dual energy imaging KW - Direct detection PY - 2018 UR - https://ieeexplore.ieee.org/document/8584559 SN - 978-1-5386-1615-4 DO - https://doi.org/10.1109/FENDT.2017.8584559 VL - 2017 SP - 281 EP - 285 PB - IEEE Xplore AN - OPUS4-47175 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Jechow, Mirko ED - Thompson, D. O. ED - Chimenti, D. E. T1 - Concepts for evaluation of image quality in digital radiology N2 - Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described. T2 - 38th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 17.07.2011 KW - Image resolution KW - Inspection KW - Production engineering computing KW - Radiography KW - Welding KW - X-ray imaging KW - ZfP KW - Radiographie KW - Bildqualität KW - Filmersatz KW - Digitale Detektoren PY - 2012 SN - 978-0-7354-1013-8 DO - https://doi.org/10.1063/1.4716281 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1430 SP - 589 EP - 596 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - A new X-ray backscatter imaging technique for non-destructive testing of aerospace materials N2 - This paper presents a new X-ray backscatter technique (XBT) for non-destructive imaging of aerospace materials with only a single-sided access. It uses a special twisted slit collimator to inspect the whole object by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (>500 keV) X-ray sources. Experiments were performed on thick complex structured aluminium components, stringers and honeycomb structures to validate the applicability of the present technique to image small changes in the material properties and also to detect low-density material inclusions. In order to reduce the inspection time from hours to several seconds and to improve the image quality of the X-ray backscatter image, the backscattered signals were measured using a digital detector array with high spatial resolution (200 µm). The influence of the energy of the X-ray source and the slit width of the camera on the X-ray backscatter image were also investigated. In the proposed technique, the whole object is irradiated by an un-collimated X-ray beam resulting in a low image acquisition time of 3 min that facilitates the use of XBT for the real time NDT&E of aerospace materials. KW - X-ray backscatter imaging KW - Digital radiography KW - Digital detector array KW - Non-destructive evaluation KW - Aerospace applications PY - 2015 DO - https://doi.org/10.1016/j.ndteint.2014.09.008 SN - 0963-8695 VL - 70 SP - 41 EP - 52 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-32515 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe T1 - Minimum requirements for digital radiography equipment and measurement procedures by different industries and standard organizations N2 - The digital photography has almost completely substituted the film photography. The film replacement is also fast progressing in medical X-ray radiography. This process is slower in NDT and especially in Europe. Reasons for the hesitating change to digital radiography (RT-D) in NDT are the necessary time for adoption of standards and the conservative request for film RT by auditors and NDT managers for applications in large plants and at construction areas. The fast serial inspection for small castings is already almost completely dominated by RT-D due to the cost effective short exposure and interpretation times. Standards were developed in parallel at CEN, ISO, ASTM and ASME. Unfortunately, the standard practices are different and the requirements on image quality and useable hardware are different too. The first standard series on Computed Radiography were developed and published by CEN and ASTM in 2005. Harmonized classification and qualification standards are available but the published practices are different. ASTM has developed the first standards for application of Digital Detector Arrays (DDA) in 2010. The first digital RT ISO standard practice is ISO 17636-2 (2013), which describes the practice for application of DDAs and Imaging Plates for weld inspection. At the first time this standard provides requirements for the selection of suitable hardware. Minimum image quality requirements are specified in analogy to film radiography and 3 Compensation Principles are defined to enable the application of a wider range of digital detectors. A comparison of the different international digital RT standards is given and first experiences with ISO 17636-2 are discussed. New standards on RT wall thickness and corrosion measurements (EN 16407, film and digital) have been developed recently. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - NDT KW - X-Ray KW - Digital detectors KW - Standards KW - Radiographic procedures KW - Unsharpness KW - Basic spatial resolution KW - Requirements KW - Digital industrial radiology PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323081 UR - https://www.ndt.net/?id=16708 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 18 PB - NDT.net CY - Kirchwald AN - OPUS4-32308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Rädel, Christoph A1 - Zscherpel, Uwe A1 - Meinel, Dietmar A1 - Ewert, Uwe A1 - Buecherl, T. A1 - Hasenstab, A. T1 - Fast neutron radiography and tomography of wood N2 - Wood is the material that has accompanied the whole development of mankind in various applications, for manufacturing tools and weapons, for buildings and constructions and also as fuel. It has various appearances and is subjected to decomposing changes, so there are sufficient arguments for non-destructive testing of wooden objects in the same way as is common practice with other technologically used materials. However, even today wood is rarely tested. Moreover, artefacts of cultural heritage containing wood are rare and delicate, so dismantling these for studying purposes is undesirable. Radiological inspection technologies are the methods of choice to provide a non-destructive insight. Interrogations of a specimen with various kinds of radiation provide different answers about their internal structures. High-quality detailed images are achievable with X-rays or gamma radiation in cases where heavy metals or other dense materials are not involved. Neutrons behave complementarily; they are avidly absorbed by light elements such as hydrogen on the one hand and yet are capable of easily penetrating heavy metals on the other. This provides an alternative for X-ray radiography and tomography when material characteristics are of primary interest rather than structural details, or when shielding with plates or sleeves of heavy metal severely impedes inspections with X-ray or gamma radiation technologies. However, due to the moderating effect of wooden samples it is essential to use fast neutrons for radiography and tomography of voluminous objects. Some typical examples described here will show the difference between neutron and X-ray photon-based radiographic technologies. KW - Materialgeschichtliches KW - Vergleich zwischen Röntgen- und Neutronenradiographie PY - 2008 DO - https://doi.org/10.1784/insi.2008.50.6.307 SN - 0007-1137 VL - 50 IS - 6 SP - 307 EP - 311 PB - British Institute of Non-Destructive Testing CY - Northampton AN - OPUS4-18034 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Bavendiek, Klaus T1 - Digitale Radiologie in der ZfP - Belichtungszeit und Kontrastempfindlichkeit - Der Äquivalenzwert zur optischen Dichte des Films KW - Digitale Radiologie PY - 2005 SN - 1616-069X SN - 0948-5112 VL - 97 SP - 41 EP - 47 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung CY - Berlin AN - OPUS4-22947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Horky, M. A1 - Kennedy, J. A1 - Hutchinson, M. T1 - Ein neues PC-basiertes Konzept zur Beurteilung moderner digitaler Röntgendetektoren mit Referenzbildern T2 - DGZfP-JAHRESTAGUNG 2002 CY - Weimar, Germany DA - 2002-05-06 PY - 2002 AN - OPUS4-19973 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thoms, M. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Image Quality of High Definition Computed Radiography (HDCR) in NDT T2 - INDE 2007 CY - Chennai, India DA - 2007-04-24 PY - 2007 AN - OPUS4-19967 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Beckmann, Jörg A1 - Bavendiek, K. T1 - Digital radiography - Films and digital detectors in comparison T2 - MINDTCE `09 - Malaysia international NDT conference and exhibiton `09 - NDT Driving industry safety, growth and performance CY - Kuala Lumpur, Malaysia DA - 2009-07-20 KW - Radiography KW - Film replacement KW - Computed radiography KW - Imaging plates KW - Digital detector arrays KW - Contrast sensitivity KW - SNR KW - standards PY - 2009 SP - 181 EP - 189 AN - OPUS4-20253 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Jechow, Mirko A1 - Fratzscher, Daniel A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bücherl, T. A1 - Hasenstab, A. A1 - Weiss, P. A1 - Weiss, C. A1 - Tannert, T. T1 - Strukturmerkmale im Holz - radiologisch gesehen N2 - Die radiologische Untersuchung von Holz ist hinsichtlich der Durchführung und Auswertung komplex. Im Gegensatz zu künstlich hergestellten Materialien zeichnet sich Holz besonders durch seine Heterogenität und Individualität aus, kein Stück ist wie das andere. Dies erschwert bei der radiologischen Inspektion die Fehlerdetektion, da diese teilweise schwer von natürlichen Wachstumsmerkmalen zu unterscheiden sind. Insektenfraßgänge und Hohlräume durch biologischen Abbau sind deutlich erkennbar, schwieriger wird es bei feinen Rissen und Anzeichen für Fäulnis. Metallische Einbauten wie Nägel und Bolzen sind natürlich gut zu erkennen, großflächigere Platten können jedoch den Einblick in die benachbarten Gebiete versperren. Klebstoffschichten sind im Röntgenbild nur dann sichtbar, wenn sie exakt parallel zum Strahlengang getroffen werden. Verschiedene Strukturmerkmale treten also radiologisch recht unterschiedlich in Erscheinung, deshalb liegt es nahe, zu deren Erkennung mehr als nur eine Durchstrahlungstechnologie anzuwenden. Während bei immobilen Objekten, d.h. Bauwerken und Bäumen, mobile Durchstrahlungstechniken mit Röntgen- oder Gammastrahlen (Se-75) in Frage kommen, stehen im Labor auch (schnelle) Neutronen alternativ zur Verfügung. Die verschiedenen Techniken, einschließlich der Tomographie mit Neutronen, werden an zwei größeren Prüfteilen demonstriert, einer Brettschichtholzprobe und einem Knotenpunkt aus einer Holzbrücke mit eingebauter Stahlplatte. Neutronen lassen Materialunterschiede differenzierter hervortreten und durchdringen sperrige Metallteile besser, trotz verringerter Bildqualität. An Verbesserungen wird derzeit gearbeitet. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Mobile Radiographie KW - Holzbauteilprüfung PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Poster 14) SP - 1 EP - 2 CY - Berlin AN - OPUS4-22532 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckmann, Jörg A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Skerik, M. T1 - Image Quality Assessment of CR Systems N2 - Computed Radiography exposure experiments on welded plate sections were performed to demonstrate that the requirements for pressure vessels weld inspection according to EN1435 or EN14784-2 class B can be achieved. The representative comparative studies of the image qualities were performed with standardized image quality indicators and image evaluation procedures on both film and digital radiographs. Recommendations for weld inspections with CR systems are drawn from the results. It is demonstrated that present CR systems can be used for weld inspection and produce images with testing class B if the selected X-ray tube voltage is reduced compared with the max. voltage of EN 14784-2 and set equivalent to maximum X-ray voltage values for steel as defined in the radioscopic standard EN 13068-3. The work was part of the European 'Filmfree' Project promoted during the 6’th framework. T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Film KW - Digital radiography KW - Computed radiography KW - Image quality PY - 2010 UR - http://www.ndt.net/article/ecndt2010/reports/1_04_07.pdf IS - Paper 4.02.18 SP - 1 EP - 10 AN - OPUS4-22536 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Bavendiek, K. A1 - Robbins, J. A1 - Zscherpel, Uwe A1 - Bueno, C. A1 - Gordon, T. A1 - Mishra, D. T1 - New compensation principles for enhanced image quality in industrial radiology with digital detector arrays KW - Radiography KW - Film replacement KW - Digital detector arrays KW - Contrast sensitivity KW - SNR KW - CNR KW - Spatial resolution KW - Bad pixels KW - Standards KW - Compensation principles PY - 2010 SN - 0025-5327 VL - 68 IS - 2 SP - 163 EP - 168 PB - Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-22538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Jechow, Mirko A1 - Fratzscher, Daniel A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bücherl, T. A1 - Schillinger, B. A1 - Schwabe, A. A1 - Hasenstab, A. A1 - Weiss, P. A1 - Weiss, C. A1 - Tannert, T. T1 - Durchstrahlungsverfahren - Ein komplexer Einblick in Objekte, ohne sie zu zerlegen T2 - Jahrestagung Archäometrie und Denkmalpflege 2010 CY - Bochum, Deutschland DA - 2010-09-15 KW - Mobile Radiographie KW - Neutronentomographie KW - Archäologischer Nassholzfund PY - 2010 SN - 0947-6229 IS - Metalla Sonderheft SP - 52 EP - 54 CY - Bochum AN - OPUS4-22539 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Beckmann, Jörg A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Untersuchungen zur Optimierung der Bildqualität in der Computer-Radiografie für die Schweißnahtprüfung N2 - In der Filmradiografie kann durch den Einsatz von Metallfolien und Metallfolienkombinationen der Bildkontrast verbessert werden. Die Mechanismen zur Erzeugung der latenten Röntgenbilder und deren Sichtbarmachung für das menschliche Auge sind in Speicherfolien nicht mit denen in einem Röntgenfilm identisch. Demzufolge lassen sich die in den Normen zur Filmradiografie veröffentlichten Empfehlungen zum Einsatz von Metallfolien und zur Auswahl der Röhrenspannung nicht unmittelbar auf die Computer-Radiografie zur Schweißnahtprüfung übertragen. Die Qualität digitaler Röntgenbilder wird von der Bildunschärfe und dem Kontrast-zu-Rausch-Verhältnis (CNR) bestimmt. Während die Norm EN 14784-1 handhabbare Verfahren zur Bestimmung der inneren Unschärfe und des Signal-zu-Rausch-Verhältnisses (SNR) beschreibt, sind die in EN 14784-2 vorgegebenen Vorgehensweisen zur Kontrastverbesserung durch die Vorgaben zur geeigneten Röhrenspannung und Metallfoliendicke für die Schweißnahtprüfung nicht ausreichend dargelegt. Um die Parameter zur Verbesserung der Bildqualität von CR-Systemen für den Fall der radiografischen Durchstrahlungsprüfung von Schweißnähten zu optimieren, wurden systematische Untersuchungen zum Einfluss eines Kupfer-Vorfilters, von Bleifolien-Speicherfolien-Kombinationen und der Röhrenspannung auf den Bildkontrast von Stahlstufenaufnahmen durchgeführt. Auf der Grundlage dieser Ergebnisse wurden Empfehlungen zum Einsatz der Metallfilter und -folienkombinationen sowie zur Auswahl geeigneter Röhrengrenzspannungen für die Speicherfolientechnik zur Optimierung der Durchstrahlungsprüfung von Schweißnähten abgeleitet. KW - Speicherfolien KW - Digitale Radiographie KW - Schweißnahtprüfung KW - Durchstrahlungsprüfung PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 552 EP - 559 PB - Hanser CY - München AN - OPUS4-18345 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Beckmann, Jörg A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Zscherpel, Uwe A1 - Jechow, Mirko A1 - Großer, A. T1 - Fehlergrößenabhängige Kontrastreduktion und zusätzliche Unschärfe durch Streustrahlung reduzierendie Bildqualität radiologischer Abbildungen - Film und digitale Detektoren im Vergleich T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Digitale Radiologie KW - Streuverhältnis KW - Strahlenkontrast KW - Unschärfe PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Di.1.A.1) SP - 133 EP - 144 AN - OPUS4-18349 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckmann, Jörg A1 - Rachny, S. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Improved Procedure for Computed Radiography - A Comparative Study on Welded Tube Sections by Film Radiography and Computed Radiography N2 - Different girth welds of tube sections have been inspected by elliptical projection technique according to the EN 1435. The radiographic images were taken by using both film radiography and computed radiography. The purpose of this study was to compare a C3 (AGFA D4) film system and a Duerr HDCR 35 NDT / HR IP imaging plate system with respect to the exposure time, image quality and the detection of fine weld imperfections. The results indicate to a dominant influence of the lead screens on the image contrast sensitivity if doing the inspection according to the EN 14748 -2 for imaging plate exposures. New screen combinations had been applied to make a computed radiograph of a testing class B quality possible. T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Film KW - Digital radiography KW - Computed radiography KW - Image quality PY - 2008 IS - Paper 69 SP - 1 EP - 7 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18412 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Großer, Anja A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einfluss von Metall - Speicherfolien - Kombinationen auf die Bildqualität in der Computer - Radiographie N2 - Bei der Normgestaltung für Speicherfolien sind die Auswirkungen von Metallfolien und Metallfolienkombinationen auf die Bildqualität von Speicher-folienaufnahmen nicht ausreichend berücksichtigt worden. Es ist bekannt, dass bei Film - Metallfolien - Kombinationen zusätzlich zur Änderung der optischen Dichte und der Filmgranularität auch Änderungen der inneren Unschärfe durch den seitli-chen Energietransport in der Film – Metallfolien - Kombination entstehen, welche überwiegend durch ausgelöste Elektronen und zum Teil durch sekundäre Strahlung hervorgerufen werden. Gleichzeitig dienen die Metallfolien bei Röntgenaufnahmen mit Film als Streustrahlfilter und können zur Verbesserung des Bildkontrastes bei-tragen. Die Mechanismen zur Erzeugung des virtuellen Röntgenbildes und dessen Visualisierung sind in Speicherfolien nicht mit denen in einem Röntgenfilm iden-tisch. Demzufolge können die in den Normen festgelegten Vorschriften zum Einsatz von Metallfolien in der Filmradiographie nicht auf Speicherfolien uneingeschränkt übertragen werden. Anhand der hier erzielten Ergebnisse lassen sich Empfehlungen zum zukünftigen Einsatz der Metallfilter und -folienkombinationen für die Speicher-folientechnik zur Verbesserung der Bildgüte ableiten. T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 29) SP - 1 EP - 8 AN - OPUS4-18413 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Großer, Anja A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einfluss von Metall-Speicherfolien-Kombinationen auf die Bildqualität in der Computer-Radiographie T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Speicherfolien KW - Durchstrahlungsprüfung KW - Computer Radiographie KW - Metallfolien PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 29) SP - 847 EP - 856 AN - OPUS4-18351 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -