TY - CONF A1 - Ewert, Uwe A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger T1 - A Benchmark Concept for Simulation in Radiographic Testing T2 - Review of Progress in Quantitative Nondestructive Evaluation CY - Baltimore, MD, USA DA - 2013-07-22 PY - 2013 AN - OPUS4-30840 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - A benchmark concept for simulation in radiographic testing N2 - The new standard ISO 17636–2:2013 'NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors' describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636-2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 11699–1 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SRb) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Digital radiography KW - Computed radiography KW - Benchmark KW - EPS KW - Modeling KW - Simulation KW - Contrast to noise ratio KW - Observer model PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 U6 - https://doi.org/10.1063/1.4865044 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 33A SP - 1816 EP - 1823 PB - AIP Publishing AN - OPUS4-30904 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schumm, A. A1 - Martin, E. A1 - Beaumont, M. A1 - Ewert, Uwe A1 - Kolkoori, Sanjeevareddy A1 - Zscherpel, Uwe A1 - Wrobel, Norma A1 - Redmer, Bernhard T1 - A comparative study on the performance of digital detector systems for high energy applications N2 - For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Radiography KW - Image quality KW - Betatron KW - Digital detector array (DDA) KW - Casting KW - Standards KW - High energy radiography KW - Comparison of detectors KW - Steel weldment PY - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-323075 UR - https://www.ndt.net/?id=16394 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 6 PB - NDT.net CY - Kirchwald AN - OPUS4-32307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - A new X-ray backscatter imaging technique for non-destructive testing of aerospace materials N2 - This paper presents a new X-ray backscatter technique (XBT) for non-destructive imaging of aerospace materials with only a single-sided access. It uses a special twisted slit collimator to inspect the whole object by changing the viewing direction of the X-ray backscatter camera. For the first time, the X-ray backscatter measurements were conducted using high-energy (>500 keV) X-ray sources. Experiments were performed on thick complex structured aluminium components, stringers and honeycomb structures to validate the applicability of the present technique to image small changes in the material properties and also to detect low-density material inclusions. In order to reduce the inspection time from hours to several seconds and to improve the image quality of the X-ray backscatter image, the backscattered signals were measured using a digital detector array with high spatial resolution (200 µm). The influence of the energy of the X-ray source and the slit width of the camera on the X-ray backscatter image were also investigated. In the proposed technique, the whole object is irradiated by an un-collimated X-ray beam resulting in a low image acquisition time of 3 min that facilitates the use of XBT for the real time NDT&E of aerospace materials. KW - X-ray backscatter imaging KW - Digital radiography KW - Digital detector array KW - Non-destructive evaluation KW - Aerospace applications PY - 2015 U6 - https://doi.org/10.1016/j.ndteint.2014.09.008 SN - 0963-8695 VL - 70 SP - 41 EP - 52 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-32515 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Ewert, Uwe T1 - A new X-ray backscatter technology for aviation security applications N2 - In order to enhance the supply chain security at airports, the German federal ministry of education and research has initiated the project ESECLOG (enhanced security in the air cargo chain) which has the goal to improve the threat detection accuracy using one-sided access methods. In this paper, we present a new X-ray backscatter technology for non-intrusive imaging of suspicious objects (mainly low-Z explosives) in luggage's and parcels with only a single-sided access. A key element in this technology is the X-ray backscatter camera embedded with a special twisted-slit collimator. The developed technology has efficiently resolved the problem related to the imaging of complex interior of the object by fixing source and object positions and changing only the scanning direction of the X-ray backscatter camera. Experiments were carried out on luggages and parcels packed with mock-up dangerous materials including liquid and solid explosive simulants. In addition, the quality of the X-ray backscatter image was enhanced by employing high-resolution digital detector arrays. Experimental results are discussed and the efficiency of the present technique to detect suspicious objects in luggages and parcels is demonstrated. At the end, important applications of the proposed backscatter imaging technology to the aviation security are presented. T2 - 2015 IEEE International Symposium on Technologies for Homeland Security (HST) CY - Waltham, MA, USA DA - 14.04.2015 KW - X-ray backscatter imaging KW - Digital radiography KW - Detection of dangerous materials KW - Luggage inspection KW - One-sided access method KW - Security applications PY - 2015 SN - 978-1-4799-1736-5 U6 - https://doi.org/10.1109/THS.2015.7225329 SP - 1 EP - 5 PB - IEEE AN - OPUS4-34027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wieder, Frank A1 - Ewert, Uwe A1 - Vogel, Justus A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - A Novel Multi Slit X-Ray Backscatter Camera Based on Synthetic Aperture Focusing N2 - A special slit collimator was developed earlier for fast acquisition of X-ray back scatter images. The design was based on a twisted slit design (ruled surfaces) in a Tungsten block to acquire backscatter images. The comparison with alternative techniques as flying spot and coded aperture pin hole technique could not prove the expected higher contrast sensitivity. In analogy to the coded aperture technique, a novel multi slit camera was designed and tested. Several twisted slits were parallelly arranged in a metal block. The CAD design of different multi-slit cameras was evaluated and optimized by the computer simulation packages aRTist and McRay. The camera projects a set of equal images, one per slit, to the digital detector array, which are overlaying each other. Afterwards, the aperture is corrected based on a deconvolution algorithm to focus the overlaying projections into a single representation of the object. Furthermore, a correction of the geometrical distortions due to the slit geometry is performed. The expected increase of the contrast-to-noise ratio is proportional to the square root of the number of parallel slits in the camera. However, additional noise has to be considered originating from the deconvolution operation. The slit design, functional principle, and the expected limits of this technique are discussed. T2 - 43rd Annual Review of Progress in QNDE CY - Atlanta, GA, USA DA - 17.07.2016 KW - Deconvolution KW - Back scatter imaging KW - Computer simulation KW - Aperture focusing PY - 2017 SN - 978-0-7354-1474-7 U6 - https://doi.org/10.1063/1.4974711 VL - 1806 SP - 1 EP - 9 PB - AIP Publishing AN - OPUS4-42429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Osterloh, Kurt A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Beckmann, Jörg A1 - Hentschel, Manfred P. ED - Beyerer, J. T1 - Advanced radiological technologies for imaging and characterisation of threats T2 - 2nd Security Research Conference "Future Security" CY - Karlsruhe, Germany DA - 2007-09-12 KW - Threat Detection KW - Dual Energy KW - Multiple View Inspection KW - Terahertz Imaging KW - Explosives PY - 2007 SN - 978-3-86644-147-7 SP - 116 EP - 119 PB - Universitätsverl. CY - Karlsruhe AN - OPUS4-18348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Schmidt, Richard A1 - Ewert, Uwe A1 - Berndt, A. A1 - Strebl, F. T1 - Agenda 2020 for a European Certification System for CBRNE Sensor Systems and Devices - the Concept for a Road Map N2 - Developments for technologies were initiated by the European Commission to improve future response capabilities and strategies to prevent terrorist attacks, to reduce the vulnerability to terrorism and to minimize the extent of damage from terrorist attacks. CBRN civil protection faces a growing significance in this concept and modern detectors and detection systems play the key role for a future reliable functioning that counters terrorism in Europe. The European Union is supporting the project CREATIF which is dedicated to provide a communication platform for technology users and decision makers, providers, and testers. First ideas were designed, strategies developed, preconditions and rules were named for a future internationally recognized certification system. A concept for a future European Certification System for CBRNE Sensor Systems and Devices and Processes has been developed, which is described in more detail. T2 - 1st International symposium on development of CBRN defence capabilities CY - Berlin, Germany DA - 2010-11-30 KW - WMD KW - CBRNE KW - Certification KW - Testing PY - 2010 SN - 978-3-935938-75-4 IS - P10.5 SP - 1603 EP - 1606 CY - Bonn AN - OPUS4-22879 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe T1 - Aktuelle Entwicklungen in der Normung N2 - Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei der Prüfpraxis, der Qualitätssicherung in der digitalen Radiographie und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der „Standard Guide for Computed Tomography“, ASTM E 1441, zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wurde revidiert und veröffentlicht. Die Mehrzahl der Hersteller von CT-Anlagen bietet entsprechende Software-Tools an. Weiterhin werden neue Festkörperentwürfe zur Charakterisierung von CT-Anlagen vorgestellt. Die folgenden Revisionen sind bei ASTM derzeit in Bearbeitung: ASTM E 2445, „CR Long Term Stability“ nach einem Round Robin-Test und für DDAs der Standard zur System-Charakterisierung, ASTM E2597/E2597M−14, und zur „DDA Long Term Stability“. Das Spider-Net-Diagramm zur Klassifizierung von DDAs wird um die Position „ISO Material Thickness limit“ erweitert. Der Standard EN 12679 zur Messung der Größe von Gammastrahlern wurde nach Revision unter Berücksichtigung von digitalen Messverfahren veröffentlicht. Die Revision der Standardserie EN 12543 zur Messung der Brennfleckgröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Die Messprozedur für Lochkameras wurde grundlegend revidiert und ist harmonisiert mit ASTM E 1165-12(2017). Die gemessenen Brennflecke unterscheiden sich und passen besser zu den Unschärfe-Messungen mit Doppeldraht BPKs (ISO 19232-5:2018) bei Vergrößerung. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren und Mikro-Fokusröhren (< 5 µm) wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Es wird über erste Ergebnisse informiert. T2 - 19. Seminar Aktuelle Fragen der Durchstrahlungsprüfung und Strahlenschutz CY - Online meeting DA - 23.03.2021 KW - Industrielle Durchstrahlungsprüfung KW - ZfP KW - Normentwicklung RT KW - DIN ISO ASTM International PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-524149 SP - Paper 8, 1 EP - Paper 8, 15 PB - DGZfP AN - OPUS4-52414 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Aktuelle Entwicklungen in der Standardisierung N2 - In den letzten zwei Jahren wurden 11 neue Standards/Standardrevisionen zur RT veröffentlicht (ohne Strahlenschutz) und 5 werden dafür gestrichen. Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei Prüfpraxis und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Die Standards zur Schweißnahtprüfung in der Kerntechnik, DIN 25435, wurden ins Englische übertragen und bei ISO TC 85 SC 6 bearbeitet. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der Guide ASTM E 1441 zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wird revidiert. E 2445 zur CR Long Term Stability wird ebenfalls revidiert. Die Revision soll auch in die ISO 16371-1 eingehen. Dazu ist ein Round Robin-Test geplant. Auch die Standards zur Durchstrahlungsprüfung auf Korrosion und Ablagerungen in Rohren mit Röntgen- und Gammastrahlen (EN 16407-1, -2, 2014) wurden revidiert. Diese Revision wurde als DIN EN ISO 20769-1, -2 2018 veröffentlicht und EN 16407 wird zurückgezogen. Die Revision der Standards EN 12543 und EN 12679 zur Messung der Brennfleckgröße und der Strahlergröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Zur radiographischen Gussteilprüfung wurde der Standard EN 12681 revidiert und 2018 veröffentlicht. Er wurde um Zulässigkeitsgrenzen erweitert und die digitale Radiographie wurde in Teil 2 berücksichtigt. T2 - 17. Seminar der DGZfP "Aktuelle Fragen der Durchstrahlungsprüfung und des Strahlenschutzes" CY - Kassel, Germany DA - 28.03.2019 KW - Digitale Radiographie KW - Standards KW - Bildqualität KW - Klassifizierung PY - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-505371 UR - https://www.ndt.net/search/docs.php3?id=24807 VL - 24 IS - 12 SP - 1 EP - 5 PB - NDT.net CY - Kirchwald AN - OPUS4-50537 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -