TY - CONF A1 - Dorgerloh, Ute T1 - Vorstellung analytischer Verfahren zur Bestimmung organischer Inhaltsstoffe in Trink- und Abwasser T2 - Lehrerweiterbildung Bundesanstalt für Materialforschung und -prüfung CY - Berlin, Germany DA - 1998-07-03 PY - 1998 AN - OPUS4-5687 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Volatile hydrocarbons in contaminated soil: Robustness of fractional quantification using headspace gas chromatography-mass-spectrometry N2 - Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed. KW - Gasoline KW - Contaminated site KW - Equivalent carbon number KW - Fuel KW - Static headspace PY - 2018 DO - https://doi.org/10.1080/15320383.2018.1418287 SN - 1532-0383 SN - 1549-7887 VL - 27 IS - 1 SP - 1 EP - 12 PB - Taylor & Francis AN - OPUS4-43889 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Validierungsringversuch DIN 38407 F43: Volatile Organic Compounds (VOC) in ground water T2 - NAW, I.3, AK5 und AK20 CY - Mülheim an der Ruhr, Germany DA - 2013-05-22 PY - 2013 AN - OPUS4-28278 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - Trace analysis of organic contaminant in groundwater: Specific requirements for analyte stabilization during success monitoring of remediation efforts T2 - ICEI 2013 CY - Trier, Germany DA - 2013-09-16 PY - 2013 AN - OPUS4-28745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - The quantification of hydrogen and methane in contaminated groundwater: validation of robust procedures for sampling and quantification N2 - A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM. PY - 2010 DO - https://doi.org/10.1039/c0em00091d SN - 1464-0325 SN - 1464-0333 VL - 12 IS - 10 SP - 1876 EP - 1884 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-22176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mueller, Axel A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Simon, Franz-Georg A1 - Braun, Ulrike T1 - The effect of polymer aging on the uptake of fuel aromatics and ethers by microplastics N2 - Microplastics are increasingly entering marine, limnic and terrestrial ecosystems worldwide, where they sorb hydrophobic organic contaminants. Here, the sorption behavior of the fuel-related water contaminants benzene, toluene, ethyl benzene and xylene (BTEX) and four tertiary butyl ethers to virgin and via UV radiation aged polypropylene (PP) and polystyrene (PS) pellets was investigated. Changes in material properties due to aging were recorded using appropriate polymer characterization methods, such as differential scanning calorimetry, Fourier transform infrared spectroscopy, gel permeation chromatography, X-ray photoelectron spectroscopy, and microscopy. Pellets were exposed to water containing BTEX and the ethers at 130-190 mg/L for up to two weeks. Aqueous sorbate concentrations were determined by headspace gas chromatography. Sorption to the polymers was correlated with the sorbate's Kow and was significant for BTEX and marginal for the ethers. Due to substantially lower glass transition temperatures, PP showed higher sorption than PS. Aging had no effect on the sorption behavior of PP. PS sorbed less BTEX after aging due to an oxidized surface layer. KW - BTEX KW - Polypropylene KW - Polystyrene KW - Sorption KW - Degradation PY - 2018 DO - https://doi.org/10.1016/j.envpol.2018.04.127 SN - 0269-7491 VL - 240 SP - 639 EP - 646 PB - Elsevier CY - Amsterdam AN - OPUS4-44990 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. T1 - Standortauswahl und Feldversuche zur Bestimmung organischer Schadstoffe in Grundwasserproben T2 - Stabilisierung von Grundwasserproben zur Bestimmung organischer Schadstoffe - LFP Projekt B4.11 CY - Berlin, Germany DA - 2012-01-26 PY - 2012 AN - OPUS4-25841 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Nehls, Irene T1 - Stabillisierung von Grundwasserproben zur Bestimmung organischer Inhaltsstoffe T2 - Altlastensymposium 2014 CY - Fulda, Germany DA - 2014-03-19 PY - 2014 AN - OPUS4-30286 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - Stabilization of groundwater samples for determination of volatile organics T2 - ICEI 2013 CY - Trier, Germany DA - 2013-09-16 PY - 2013 AN - OPUS4-28746 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. T1 - Stabilisierung von Proben im Bereich der in-situ-Sanierung aktivierter Grundwasserproben T2 - Stabilisierung von Grundwasserproben zur Bestimmung organischer Schadstoffe - LFP Projekt B4.11 CY - Berlin, Germany DA - 2012-10-26 PY - 2012 AN - OPUS4-27063 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene A1 - Theißen, H. A1 - Hilbert, S. T1 - Stabilisierung von Grundwasserproben für die Wasseranalytik T2 - DECHEMA Jahrestagung "Sanierung" CY - Frankfurt am Main, Germany DA - 2012-11-26 PY - 2012 AN - OPUS4-26442 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. T1 - Stabilisierung von Grundwasserproben T2 - Altlastenausschuss (ALA) CY - Dresden, Germany DA - 2013-06-18 PY - 2013 AN - OPUS4-28277 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Nehls, Irene T1 - Stabilisation of groundwater samples for the quantification of organic trace pollutants N2 - The concentration of contaminants in groundwater samples can be decreased by degradation in the time course between field sampling and quantification in the laboratory, especially in samples from sites where degradation activity is enhanced by remediation measures. The sampling sites covered a variety of priority organic pollutants such as volatile aromatic and chlorinated compounds, phenols and petroleum hydrocarbons and different remediation strategies such as anaerobic and aerobic microbial in situ degradation, in situ chemical oxidation, and on-site purification with biological treatment. The stability of the contaminants' concentration was investigated over a time range of several hours without cooling in the autosampler of the analytical equipment (short term) and over several days of storage until analysis (long term). A number of stabilisation techniques suggested in international standards ISO 5667-3:2013 and ASTM D6517:2000 were compared both with regard to short term and long term stabilisation of the contaminants and their practicability for field sampling campaigns. Long term storage turned out to be problematic for most compound groups even under cooling. Short term stability was problematic also for volatiles such as benzenic aromates, naphthalene and volatile organic halogenated compounds to be analysed by headspace gas chromatography. Acidification (pH <2) was sufficient to prevent degradation of benzenic aromates, naphthalene, phenols and petrol hydrocarbons for up to seven days. The use of acids was not applicable to stabilise volatiles in waters rich in carbonates and sulphides due to stripping of the volatiles with the liberated gases. The addition of sodium azide was successfully used for stabilisation of volatile organic halogenated compounds. KW - Groundwater KW - Sampling KW - Organic pollutants KW - Stabilisation KW - Analysis PY - 2013 DO - https://doi.org/10.1039/c3em00332a SN - 2050-7887 SN - 2050-7895 VL - 15 IS - 12 SP - 2329 EP - 2337 PB - RSC Publ. CY - CambridgeRSC Publ. AN - OPUS4-29689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Short-chain perfluoroalkyl acids: TFA and DFA N2 - Analysis in environmental media and discussion for method standardization in NAW T2 - Normausschuss Wasserwesen CY - Frankfurt a.M., Germany DA - 28.03.2019 KW - TFA KW - DFA PY - 2019 AN - OPUS4-47742 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Robustheitsstudie zur ISO 16558-1: Bestimmung von leichtflüchtigen Kohlenwasserstoffen in Boden T2 - Jahrestagung Altlastenausschuss (ALA) CY - Frankfurt am Main DA - 2015-11-12 PY - 2015 AN - OPUS4-34670 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene A1 - Brodsky, J. T1 - Robustheitsstudie ISO 16558-1: Leichtflüchtige Kohlenwasserstoffe in Boden T2 - Altlastensymposium CY - Frankfurt am Main DA - 2015-11-30 PY - 2015 AN - OPUS4-34669 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Ringversuche: Präparation mineralölkohlenwasserstoffhaltiger Wasserproben T2 - GDCh Jahrestagung, Wasserchemische Gesellschaft CY - Trier, Germany DA - 2008-04-28 PY - 2008 AN - OPUS4-16731 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Ringversuche: Präparation mineralölkohlenwasserstoffhaltiger Abwasserproben KW - Analytik KW - Ringversuch KW - Abwasser KW - Mineralölkohlenwasserstoff KW - Probe KW - Qualitätssicherung KW - Chemical analysis KW - Interlaboratory comparison KW - Wastewater KW - Mineral oil KW - Sample KW - Quality assurance PY - 2008 SN - 0083-6915 VL - 106 IS - 3 SP - 7 EP - 8 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-18289 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Nehls, Irene A1 - Erhardt, Ulla A1 - Walther, Wolfgang T1 - Ringversuch zur Bestimmung von LHKW in Grundwasser T2 - GDCh Tagung CY - Halle (Saale), Germany DA - 2006-10-04 PY - 2006 AN - OPUS4-12685 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Erhardt, Ulla A1 - Schmieder, Rosmarie A1 - Walter, W. A1 - Win, Tin A1 - Hilbert, S. A1 - Mechler, M. A1 - Nehls, Irene T1 - Ringversuch zur Bestimmung von leichtflüchtigen halogenierten Kohlenwasserstoffen (LHKW), Vinylchlorid (VC) und Fluorchlorkohlenwasserstoffen (FCKW) in Grundwasser KW - Analytik KW - Grundwasser KW - Leichtflüchtige halogenierte Kohlenwasserstoffe (LHKW) KW - Vinylchlorid (VC) KW - Fluorchlorkohlenwasserstoffe (FCKW) KW - Ringversuch KW - Analytics KW - Groundwater KW - Highly volatile halogenated hydrocarbons (VHHC) KW - Vinyl chloride (VC) KW - Chlorofluorocarbons (CFC) KW - Interlaboratory comparison PY - 2004 SN - 0083-6915 VL - 102 IS - 2 SP - 12 EP - 16 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-4126 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Sauer, Andreas A1 - Hofmann, Andrea T1 - Quality control in extended measurement campaigns: selection of contract laboratories by proficiency testing exemplified for the trace analysis of anilines in groundwater N2 - An interlaboratory comparison for the determination of aniline, nine methylated anilines and chlorinated anilines in contaminated groundwater (each compound between 1 µg L-1 and 750 µg L-1) was conducted as proficiency test for the selection of contract laboratories for a groundwater monitoring campaign. For the 13 participants, two different test sample series were prepared from a stabilized real case groundwater. Series A was the groundwater as sampled in the field and series B was prepared from series A by spiking with selected anilines. Homogeneity and stability investigations revealed that contaminated groundwater provides a viable basis for the preparation of ring test samples for the determination of anilines. Analytical procedures were limited to the standardized liquid–liquid extraction or solid-phase extraction in combination with gas chromatography/mass spectrometry (DIN 38407-16:1999). The robust consensus values were evaluated according to the standardized protocol of DIN 38402-45:2013. Robust reproducibility standard deviations ranged largely between 20?% and 60?% depending on the analyte. The proficiency assessment of individual participants combined the qualitative aspect of correct peak identification with the quantitative determination of individual concentrations within set limits in a unified approach. It could be shown that the accreditation status of laboratory and the existence of a standardized analytical procedure do not substitute a problem-related proficiency assessment of potential contractors. KW - Aniline KW - Chloroanilines KW - Methylanilines KW - Groundwater KW - Interlaboratory comparison KW - Proficiency test PY - 2014 DO - https://doi.org/10.1007/s00769-014-1072-5 SN - 0949-1775 SN - 1432-0517 N1 - Geburtsname von Sauer, Andreas: Buchholz, A. - Birth name of Sauer, Andreas: Buchholz, A. VL - 19 IS - 5 SP - 371 EP - 376 PB - Springer CY - Berlin AN - OPUS4-31756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Theissen, H. A1 - Becker, Roland A1 - Hilbert, S. A1 - Nehls, Irene T1 - Probennahme und Quantifizierung von LHKW, Ethen und Methan in Grundwasser N2 - Der Einsatz aktiver (Pumpprobennahme, Schöpfprobennahme) und passiver (Diffusionsprobennahme) Probennahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probennahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Das gaschromatographische Verfahren für Vinylchlorid mittels Dampfraumtechnik wird um die Quantifizierung von Methan und Ethen erweitert. Dabei werden für die Bewertung von Altlasten relevante Bestimmungsgrenzen von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan) erreicht. Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probennahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring- Ergebnissen sollten von Ingenieurbüros und zuständigen Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden. KW - Passive sampling KW - Active sampling KW - Groundwater KW - Trichloroethene KW - Vinyl chloride KW - Methane PY - 2010 DO - https://doi.org/10.1007/s00767-010-0144-7 SN - 1430-483X VL - 15 IS - 4 SP - 231 EP - 239 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-22617 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Nehls, Irene T1 - Probenahme von LHKW in Grundwasser: Vergleich von aktiver und passiver Probenahme KW - Grundwasser KW - Probenahme KW - LHKW KW - Pumpprobe KW - Diffusionsprobe KW - PDB PY - 2009 SN - 1618-3258 SN - 1617-5301 VL - 15 IS - 4 SP - 85 EP - 87 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-20624 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. T1 - Probenahme und Analytik für Zwischen- und Endprodukte von anaeroben Stoffverwertungsprozessen von LCKW in Grundwasser: Wasserstoff, Methan, Ethen und Vinylchlorid T2 - DECHEMA Jahrestagung CY - Frankfurt am Main, Germany DA - 2009-11-23 PY - 2009 AN - OPUS4-19883 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. T1 - Probenahme LHKW in Grundwasser: Vergleich aktive und passive Probenahme T2 - Ökotox CY - Trier, Germany DA - 2009-09-23 PY - 2009 AN - OPUS4-19881 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. T1 - Probenahme gelöster Gase in Grundwasser: Wasserstoff, Methan, Ethen und Vinylchlorid T2 - Ökotox CY - Trier, Germany DA - 2009-09-23 PY - 2009 AN - OPUS4-19880 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. T1 - Probenahme gelöster Gase in Grundwasser: Wasserstoff, Methan, Ethen und Vinylchlorid T2 - DECHEMA Jahrestagung CY - Frankfurt am Main, Germany DA - 2009-11-23 PY - 2009 AN - OPUS4-19882 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Walther, Wolfgang A1 - Becker, Roland A1 - Nehls, Irene A1 - Lehmann, Andreas A1 - Redlich, Christel A1 - Flemig, Sabine A1 - Dorgerloh, Ute A1 - Win, Tin A1 - Buge, Hans-Gerhard T1 - Pentchlorophenol (PCP) in Soil - Certified Reference Materials for Environmental Analysis T2 - Analytica Conference 2002 CY - Munich, Germany DA - 2002-04-23 PY - 2002 SP - 1(?) AN - OPUS4-1389 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Möglichkeiten und Grenzen der praktischen Umsetzung externer Qualitätssicherungsmaßnahmen in analytischen Laboratorien T2 - Fachtagung 10 Jahre Ökologisches Großprojekt Berlin CY - Berlin, Germany DA - 2003-06-26 PY - 2003 AN - OPUS4-5864 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Choteau, T. A1 - Daireaux, A. A1 - Stoppacher, N. A1 - Wielgosz, R. A1 - Davies, S. A1 - do Rego, E. A1 - Wollinger, W. A1 - Garrido, B. A1 - Fernandes, J. A1 - Lima, J. A1 - Oliveira, R. A1 - de Sena, R. A1 - Windust, A. A1 - Huang, T. A1 - Dai, X. A1 - Quan, C. A1 - He, H. A1 - Zhang, W. A1 - Wei, C. A1 - Li, N. A1 - Gao, D. A1 - Liu, Z. A1 - Lo, M. A1 - Wong, W. A1 - Pfeifer, Dietmar A1 - Koch, Matthias A1 - Dorgerloh, Ute A1 - Rothe, Robert A1 - Philipp, Rosemarie A1 - Hanari, N. A1 - Rezali, M. A1 - Arzate, C. A1 - Berenice, M. A1 - Caballero, V. A1 - Osuna, M. A1 - Krylov, A. A1 - Kharitonov, S. A1 - Lopushanskaya, E. A1 - Liu, Q. A1 - Lin, T. A1 - Fernandes-Whaley, M. A1 - Quinn, L. A1 - Nhlapo, N. A1 - Prevoo-Franzsen, D. A1 - Archer, M. A1 - Kim, B. A1 - Baek, S. A1 - Lee, S. A1 - Lee, J. A1 - Marbumrung, S. A1 - Kankaew, P. A1 - Chaorenpornpukdee, K. A1 - Chaipet, T. A1 - Shearman, K. A1 - Gören, A. A1 - Gündüz, S. A1 - Yilmaz, H. A1 - Un, I. A1 - Bilsel, G. A1 - Clarkson, C. A1 - Bedner, M. A1 - Camara, J. A1 - Lang, B. A1 - Lippa, K. A1 - Nelson, M. A1 - Toman, B. A1 - Yu, L. T1 - Mass fraction assignment of folic acid in a high purity material - CCQM-K55.d (Folic acid) Final Report N2 - The comparison required the assignment of the mass fraction of folic acid present as the main component in the comparison sample. Performance in the comparison is representative of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molecular weight range 300–500] and high polarity (pKOW < −2). Methods used by the eighteen participating NMIs or DIs were based on a mass balance (summation of impurities) or qNMR approach, or the combination of data obtained using both methods. The qNMR results tended to give slightly lower values for the content of folic acid, albeit with larger associated uncertainties, compared with the results obtained by mass balance procedures. Possible reasons for this divergence are discussed in the report, without reaching a definitive conclusion as to their origin. The comparison demonstrates that for a structurally complex polar organic compound containing a high water content and presenting a number of additional analytical challenges, the assignment of the mass fraction content property value of the main component can reasonably be achieved with an associated relative standard uncertainty in the assigned value of 0.5% KW - CCQM key comparison KW - Purity assessment KW - Folic acid PY - 2018 UR - https://www.bipm.org/utils/common/pdf/final_reports/QM/K55/CCQM-K55.d.pdf DO - https://doi.org/10.1088/0026-1394/55/1A/08013 VL - 55 IS - Technical Supplement, 2018 SP - 08013, 1 EP - 38 PB - Institute of Physics Publishing (IOP) ; Bureau International des Poids et Mesures AN - OPUS4-44999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Martos, G. A1 - Josephs, R. A1 - Choteau, T. A1 - Wielgosz, R. A1 - Davies, S. A1 - Moawad, M. A1 - Tarrant, G. A1 - Chan, B. A1 - Alamgir, M. A1 - de Rego, E. A1 - Wollinger, W. A1 - Garrido, B. A1 - Fernandes, J. A1 - de Sena, R. A1 - Oliveira, R. A1 - Melanson, J. A1 - Bates, J. A1 - Mai Le, P. A1 - Meija, J. A1 - Quan, C. A1 - Huang, T. A1 - Zhang, W. A1 - Ma, R. A1 - Zhang, S. A1 - Hao, Y. A1 - He, Y. A1 - Song, S. A1 - Wang, H. A1 - Su, F. A1 - Zhang, T. A1 - Li, H. A1 - Lam, W. A1 - Wong, W. A1 - Fung, W. A1 - Philipp, Rosemarie A1 - Dorgerloh, Ute A1 - Meyer, Klas A1 - Piechotta, Christian A1 - Riedel, Juliane A1 - Westphalen, Tanja A1 - Giannikopoulou, P. A1 - Alexopoulos, Ch. A1 - Kakoulides, E. A1 - Kitamaki, Y. A1 - Yamazaki, T. A1 - Shimizu, Y. A1 - Kuroe, M. A1 - Numata, M. A1 - Pérez-Castorena, A. A1 - Balderas-Escamilla, M. A1 - Garcia-Escalante, J. A1 - Krylov, A. A1 - Mikheeva, A. A1 - Beliakov, M. A1 - Palagina, M. A1 - Tkachenko, I. A1 - Spirin, S. A1 - Smirnov, V. A1 - Tang Lin, T. A1 - Pui Sze, C. A1 - Juan, W. A1 - Lingkai, W. A1 - Ting, L. A1 - Quinde, L. A1 - Yizhao, C. A1 - Lay Peng, S. A1 - Fernandes-Whaley, M. A1 - Prevoo-Franzsen, D. A1 - Quinn, L. A1 - Nhlapo, N. A1 - Mkhize, D. A1 - Marajh, D. A1 - Chamane, S. A1 - Ahn, S. A1 - Choi, K. A1 - Lee, S. A1 - Han, J. A1 - Baek, S. A1 - Kim, B. A1 - Marbumrung, S. A1 - Jongmesuk, P. A1 - Shearman, K. A1 - Boonyakong, C. A1 - Bilsel, M. A1 - Gündüz, S. A1 - Ün, I. A1 - Yilmaz, H. A1 - Bilsel, G. A1 - Gökçen, T. A1 - Clarkson, C. A1 - Warren, J. A1 - Achtar, E. T1 - Mass fraction assignment of Bisphenol-A high purity material N2 - The CCQM-K148.a comparison was coordinated by the BIPM on behalf of the CCQM Organic Analysis Working Group for NMIs and DIs which provide measurement services in organic analysis under the CIPM MRA. It was undertaken as a "Track A" comparison within the OAWG strategic plan. CCQM-K148.a demonstrates capabilities for assigning the mass fraction content of a solid organic compound having moderate molecular complexity, where the compound has a molar mass in the range (75 - 500) g/mol and is non-polar (pKow < −2), when present as the primary organic component in a neat organic solid and where the mass fraction content of the primary component in the material is in excess of 950 mg/g. Participants were required to report the mass fraction of Bisphenol A present in one supplied unit of the comparison material. Participants using a mass balance method for the assignment were also required to report their assignments of the impurity components present in the material. Methods used by the seventeen participating NMIs or DIs were predominantly based on either stand-alone mass balance (summation of impurities) or qNMR approaches, or the combination of data obtained using both methods. The results obtained using thermal methods based on freezing-point depression methods were also reported by a limited number of participants. There was excellent agreement between assignments obtained using all three approaches to assign the BPA content. The assignment of the values for the mass fraction content of BPA consistent with the KCRV was achieved by most of the comparison participants with an associated relative standard uncertainty in the assigned value in the range (0.1 - 0.5)%. KW - Bisphenol-A KW - Purity assessment KW - Interlaboratory key comparison KW - Metrology PY - 2021 DO - https://doi.org/10.1088/0026-1394/58/1A/08015 VL - 58 IS - 1A SP - 08015 PB - IOP Publishing AN - OPUS4-54188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Koch, Matthias T1 - Interlaboratory test for the determaination of mineral oil content in synthetic wastewater T2 - BERM-7 CY - Antwerp, Belgium DA - 1997-04-21 PY - 1997 AN - OPUS4-7513 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Nehls, Irene A1 - Dorgerloh, Ute T1 - Interlaboratory comparisons - demonstrating degree of equivalence N2 - The role of matrix reference materials in the process of demonstrating the degree of equivalence of measurement results obtained from intercomparisons is outlined, reviewing exemplary selected experience gained at BAM regarding the determination of organic contaminants in environmental matrices. The specific characteristics of reference materials employed in the process of demonstrating equivalence between laboratories in the course of proficiency testing as well as the development, comparison and validation of methods are elaborated. The demand is for series of appropriately characterised samples which are fit for the purpose and it is seen from representative examples that the utilisation of such tailor-made RM designed to tackle the specific need of an analytical problem dominates over certified matrix reference materials in this context. Concluding, the role of certified matrix reference materials in quality assurance is briefly looked at both from the user’s and providers’ points of view. KW - Certification KW - Equivalence KW - Method development KW - Proficiency testing KW - Reference materials PY - 2003 DO - https://doi.org/10.1007/s00769-003-0580-5 SN - 0949-1775 SN - 1432-0517 VL - 8 SP - 150 EP - 155 PB - Springer CY - Berlin AN - OPUS4-2848 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland T1 - Interlaboratory Comparison for the determination of MTBE and TAME in Water T2 - BERM 9 - 9th International Symposium on Biological and Environmental Reference Materials CY - Berlin, Germany DA - 2003-06-15 PY - 2003 AN - OPUS4-4792 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Erhardt, Ulla A1 - Nehls, Irene A1 - Win, Tin A1 - Hilbert, S. T1 - Instruments of Quality Assurance at Ground Water Monitoring T2 - BERM-8 CY - Bethesda, MD, USA DA - 2000-09-17 PY - 2000 AN - OPUS4-5740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Erhardt, Ulla A1 - Nehls, Irene A1 - Win, Tin A1 - Hilbert, S. T1 - Instruments of qualitiy assurance at ground water monitoring T2 - "Tag der Chemie", FU Berlin CY - Berlin, Germany DA - 2001-11-07 PY - 2001 AN - OPUS4-5829 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Helmis, M. A1 - Mumme, J. A1 - Diakité, M. A1 - Nehls, Irene T1 - Hydrothermally carbonized plant materials: Patterns of volatile organic compounds detected by gas chromatography N2 - The nature and concentrations of volatile organic compounds (VOCs) in chars generated by hydrothermal carbonization (HTC) is of concern considering their application as soil amendment. Therefore, the presence of VOCs in solid HTC products obtained from wheat straw, biogas digestate and four woody materials was investigated using headspace gas chromatography. A variety of potentially harmful benzenic, phenolic and furanic volatiles along with various aldehydes and ketones were identified in feedstock- and temperature-specific patterns. The total amount of VOCs observed after equilibration between headspace and char samples produced at 270 °C ranged between 2000 and 16,000 µg/g (0.2–1.6 wt.%). Depending on feedstock 50–9000 µg/g of benzenes and 300–1800 µg/g of phenols were observed. Substances potentially harmful to soil ecology such as benzofurans (200–800 µg/g) and p-cymene (up to 6000 µg/g in pine wood char) exhibited concentrations that suggest restrained application of fresh hydrochar as soil amendment or for water purification. KW - Hydrochar KW - Mass spectrometry KW - Flame ionization detection KW - Phenols KW - Benzenes PY - 2013 DO - https://doi.org/10.1016/j.biortech.2012.12.102 SN - 0960-8524 SN - 1873-2976 VL - 130 SP - 621 EP - 628 PB - Elsevier Applied Science CY - Barking, Essex AN - OPUS4-27616 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Paulke, E. A1 - Mumme, J. A1 - Nehls, Irene T1 - Hydrothermal carbonization of biomass: Major organic components of the aqueous phase N2 - Process waters obtained from hydrothermal carbonization (HTC) of wheat straw, a biogas digestate derived thereof, and four woody biomass feedstocks were quantified regarding the total organic carbon (TOC) and selected organic compounds. HTC runs revealed that TOC loads were largely unaffected by process severity or type of feedstock whereas the C2–C6 fatty acids, determined by GC, displayed clear effects of temperature and feedstock. HPLC demonstrated simultaneously the initial increase and subsequent consumption of cellulose-derived furfural and 5-hydroxymethylfurfural as well as the increase of the lignin-derived 2-methoxyphenol. 2-Methylbenzofuran, an example for a substance potentially harmful to aquatic biota, was observed in high concentration in the HTC liquor from wheat straw-based feedstocks. KW - Furfurals KW - Gas chromatography KW - Liquid chromatography KW - Phenols KW - Process water KW - Total organic carbon PY - 2014 DO - https://doi.org/10.1002/ceat.201300401 SN - 0930-7516 SN - 1521-4125 VL - 37 IS - 3 SP - 511 EP - 518 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-30333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Lutz, A. A1 - Bremser, Wolfram A1 - Hilbert, S. A1 - Nehls, Irene T1 - How to improve reliability in groundwater analysis: over a decade of experience with external quality control in field campaigns on volatile halogenated compounds N2 - The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached. KW - Groundwater monitoring KW - External quality management KW - QM KW - VOC PY - 2012 DO - https://doi.org/10.1039/c1em10460h SN - 1464-0325 SN - 1464-0333 VL - 14 IS - 1 SP - 217 EP - 223 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-25288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Becker, Roland T1 - Flüchtige Kohlenwasserstoffe in Boden - Stand der Technik und seine Grenzen N2 - Die inhalative Aufnahme (Wirkungspfad Boden – Mensch) von MKW bestimmt aus toxikologischer Sicht die Festlegung von Prüfwerten. Somit müssen die leichtflüchtigen Fraktionen quantifiziert werden. Die durchgeführte Robustheitsstudie des genormten Verfahrens umfasst die Ermittlung der Kenndaten der Probenahme, der Probenaufarbeitung und der Instrumentalanalytik. T2 - DECHEMA - Symposium Strategien zur Sanierung von Boden und Grundwasser CY - Frankfurt a.M., Germany DA - 20.11.2017 KW - Flüchtige Kohlenwasserstoffe KW - Kohlenwasserstofffraktionen KW - Bodenanalytik PY - 2017 AN - OPUS4-42943 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Westwood, S. A1 - Josephs, R. A1 - Choteau, T. A1 - Daireaux, A. A1 - Wielgosz, R. A1 - Davies, S. A1 - Moad, M. A1 - Chan, B. A1 - Munoz, A. A1 - Conneely, P. A1 - Ricci, M. A1 - Do Rego, E.C.P. A1 - Garrido, B.C. A1 - Violante, F.G.M. A1 - Windust, A. A1 - Dai, X. A1 - Huang, T. A1 - Zhang, W. A1 - Su, F. A1 - Quan, C. A1 - Wang, H. A1 - Lo, M. A1 - Wong, W. A1 - Gantois, F. A1 - Lalerle, B. A1 - Dorgerloh, Ute A1 - Koch, Matthias A1 - Klyk-Seitz, Urszula-Anna A1 - Pfeifer, Dietmar A1 - Philipp, Rosemarie A1 - Piechotta, Christian A1 - Recknagel, Sebastian A1 - Rothe, Robert A1 - Yamazaki, T. A1 - Zakaria, O. B. A1 - Castro, E. A1 - Balderas, M. A1 - González, N. A1 - Salazar, C. A1 - Regalado, L. A1 - Valle, E. A1 - Rodríguez, L. A1 - Laguna, L.Á.. A1 - Ramírez, P. A1 - Avila, M. A1 - Ibarra, J. A1 - Valle, L. A1 - Arce, M. A1 - Mitani, Y. A1 - Konopelko, L. A1 - Krylov, A. A1 - Lopushanskaya, E. A1 - Lin, T.T. A1 - Liu, Q. A1 - Kooi, L.T. A1 - Fernandes-Whaley, M. A1 - Prevoo-Franzsen, D. A1 - Nhlapo, N. A1 - Visser, R. A1 - Kim, B. A1 - Lee, H. A1 - Kankaew, P. A1 - Pookrod, P. A1 - Sudsiri, N. A1 - Shearman, K. A1 - Gören, A.C. A1 - Bilsel, G. A1 - Yilmaz, H. A1 - Bilsel, M. A1 - Cergel, M. A1 - Coskun, F.G. A1 - Uysal, E. A1 - Gündüz, S. A1 - Ün, I. A1 - Warren, J. A1 - Bearden, D.W. A1 - Bedner, M. A1 - Duewer, D.L. A1 - Lang, B.E. A1 - Lippa, K.A. A1 - Schantz, M.M. A1 - Sieber, J.R. T1 - Final report on key comparison CCQM-K55.c (L-(+)-Valine): Characterization of organic substances for chemical purity N2 - KEY COMPARISON Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.c, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2012. Twenty National Measurement Institutes or Designated Institutes and the BIPM participated. Participants were required to assign the mass fraction of valine present as the main component in the comparison sample for CCQM-K55.c. The comparison samples were prepared from analytical grade L-valine purchased from a commercial supplier and used as provided without further treatment or purification. Valine was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of low structural complexity [molecular weight range 100–300] and high polarity (pKOW > –2). The KCRV for the valine content of the material was 992.0 mg/g with a combined standard uncertainty of 0.3 mg/g. The key comparison reference value (KCRV) was assigned by combination of KCRVs assigned from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 1 mg/g to 6 mg/g when using mass balance based approaches alone, 2 mg/g to 7 mg/g using quantitative 1H NMR (qNMR) based approaches and from 1 mg/g to 2.5 mg/g when a result obtained by a mass balance method was combined with a separate qNMR result. The material provided several analytical challenges. In addition to the need to identify and quantify various related amino acid impurities including leucine, isoleucine, alanine and a-amino butyrate, care was required to select appropriate conditions for performing Karl Fischer titration assay for water content to avoid bias due to in situ formation of water by self-condensation under the assay conditions. It also proved to be a challenging compound for purity assignment by qNMR techniques. There was overall excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content, residual solvent and total non-volatile content of the sample. Appropriate technical justifications were developed to rationalise observed discrepancies in the limited cases where methodology differences led to inconsistent results. The comparison demonstrated that to perform a qNMR purity assignment the selection of appropriate parameters and an understanding of their potential influence on the assigned value is critical for reliable implementation of the method, particularly when one or more of the peaks to be quantified consist of complex multiplet signals. PY - 2014 DO - https://doi.org/10.1088/0026-1394/51/1A/08010 SN - 0026-1394 SN - 1681-7575 VL - 51 SP - 08010, 1 EP - 44 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-31072 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Hilbert, S. A1 - Nehls, Irene T1 - Externe Qualitätssicherung im Grundwassermonitoring in analytischen Laboratorien T2 - DECHEMA Jahrestagung CY - Frankfurt am Main, Germany DA - 2010-11-22 PY - 2010 AN - OPUS4-21850 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Externe Qualitätssicherung im Grundwassermonitoring T2 - Weiterbildungsveranstaltung der Mitarbeiter der Umweltämter, Verwaltungsakademie des Landes Berlin CY - Berlin, Germany DA - 2004-03-02 PY - 2004 AN - OPUS4-4799 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Kaiser, M. T1 - Evidence for the formation of difluoroacetic acid in chlorofluorocarbon-contaminated ground water N2 - The concentrations of difluoroacetic acid (DFA) and trifluoroacetic acid (TFA) in rainwater and surface water from Berlin, Germany resembled those reported for similar urban areas, and the TFA/DFA ratio in rainwater of 10:1 was in accordance with the literature. In contrast, nearby ground water historically contaminated with 1,1,2-trichloro-1,2,2-trifluoroethane (R113) displayed a TFA/DFA ratio of 1:3. This observation is discussed versus the inventory of microbial Degradation products present in this ground water along with the parent R113 itself. A microbial Transformation of chlorotrifluoroethylene (R1113) to DFA so far has not been reported for environmental media, and is suggested based on well-established mammalian metabolic pathways. KW - Fluoroacetic acid KW - DFA KW - TFA KW - Rainwater KW - Ground water KW - Degradation of refrigerants PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-475569 DO - https://doi.org/10.3390/molecules24061039 SN - 1420-3049 VL - 24 IS - 6 SP - 1039, 1 EP - 6 PB - MDPI CY - Basel AN - OPUS4-47556 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Erfahrungen und Probleme bei der Herstellung und Analytik wäßriger Referenzmaterialien auf der Basis realer Abwasser T2 - Abteilungsseminar Bundesanstalt für Materialforschung und -prüfung CY - Berlin, Germany DA - 1998-07-03 PY - 1998 AN - OPUS4-5686 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Axel A1 - Becker, Roland A1 - Braun, Ulrike A1 - Dorgerloh, Ute T1 - Einfluss der Alterung auf das Sorptionsverhalten von Mikroplastik, eine Laborstudie mit BTEX und Etherverbindungen N2 - Die Präsenz von Mikroplastik in aquatischen Ökosystemen ist ein globales Problem und steht zunehmend im Fokus der Öffentlichkeit. In mehreren Studien konnten Anreicherungen hydrophober, organischer Schadstoffe an MP nachgewiesen werden. Der Einfluss des Alterungszustandes der MP-Partikel auf das Sorptionsverhalten von hydrophoben organischen Substanzen ist nicht hinreichend geklärt. Ziel der vorliegenden Arbeit war die Untersuchung des Sorptionsverhaltens von Schadstoffen mit Bedeutung für limnische Gewässer an künstlich gealterten Partikeln relevanter Polymere. Das Modell verwendete die Aromaten Benzol, Toluol, Ethylbenzol und Xylol (BTEX) sowie Etherverbindungen. Diese Substanzen sind oder waren Bestandteile in unterschiedlichen Kraftstoffen und finden sich daher in vielen aquatischen Ökosystemen weltweit. Als Sorbentien kamen teilkristallines Polypropylen (PP) und amorphes Polystyrol (PS) in Form von Industriepellets zum Einsatz. Die Pellets wurden jeweils sowohl unbehandelt als auch mittels UV-Bestrahlung künstlich gealtert verwendet und mikroskopisch sowie mittels XPS, FTIR und DSC charakterisiert. Die Alterung führte bei PS zu einer verringerten Sorptionskapazität, während bei PP keine Veränderung im Sorptionsverhalten beobachtet wurde. T2 - Wasser 2017 - Jahrestagung der Wasserchemischen Gesellschaft CY - Donaueschingen, Germany DA - 22.05.2017 KW - Mikroplastik KW - Organische Schadstoffe KW - Sorption KW - Polypropylen Polystyrol PY - 2017 SN - 978-3-947197-01-9 SP - 1 EP - 606 PB - Gesellschaft Dt. Chemiker AN - OPUS4-40447 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schultze, Karin A1 - Philipp, Rosemarie A1 - Redlich, Christel A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Win, Tin A1 - Nehls, Irene T1 - Development, preparation and certification of a reference material for the determination of chlorinated pesticides in soil T2 - Symposium "Reference Materials for Technologies in the New Millenium" CY - Berlin, BAM, Germany DA - 2000-05-22 PY - 2000 SP - 1(?) EP - 4(?) AN - OPUS4-1313 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Determination of volatile organic sulfur compounds in contaminated groundwater N2 - A practical method for the quantification of total purgeable organic sulfur (POS) in highly contaminated groundwater is described. Volatile organic sulfur compounds (VOSC) are purged from the water samples by a stream of oxygen and combusted. The emerging sulfur dioxide is absorbed in H2O2 and converted to sulfate which is quantified by ion chromatography and reported as mass sulfur equivalent. The overall limit of quantification is 0.03 mg l–1. The content of POS is balanced with the total VOSC determined by GC-AED after liquid–liquid extraction. Separate determination of the non-volatile organic sulfur compounds by direct combustion of the water sample and adsorption to charcoal yielded a mass balance of the total sulfur content. Semi-quantitative GC-MS after purge & trap accumulation revealed that the VOSC mixture is composed of C1–C4 alkyl sulfides. The implementation of the developed methodology for the quantification of VOSC as potential catalyst poison in a cleaning plant for groundwater contaminated with volatile haloorganics (VOX) is presented. KW - Contamination KW - Remediation KW - Summation parameter KW - Combustion KW - Ion chromatography KW - GC-AED KW - GC-MS PY - 2008 UR - http://www.springerlink.com/content/8612g42hwj7130g8/fulltext.pdf DO - https://doi.org/10.1007/s10311-007-0117-y SN - 1610-3653 SN - 1610-3661 VL - 6 IS - 2 SP - 101 EP - 106 PB - Springer CY - Berlin AN - OPUS4-16360 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Nehls, Irene T1 - Das Problem löst sich von selbst: Stabilisierung von Grundwasserproben zur Bestimmung organischer Inhaltsstoffe N2 - Als Folge der industriellen Produktion und der vielfältigen industriellen Nutzung von organischen Lösungsmitteln sind eine Vielzahl von Edukten, Zwischen- und Endprodukten in die Umwelt eingetragen worden und führen zu massiven Verunreinigungen des Bodens und des Grundwassers. Die Untersuchung und Sanierung des Grundwassers stellt einen aktuellen Schwerpunkt in der Altlastenbearbeitung dar. Vielfach werden klassische pump & treat-Verfahren zur Grundwassersanierung verwendet. Diese aktiven Sicherungs- und Sanierungsmaßnahmen werden jedoch unter dem Gesichtspunkt der Verhältnismäßigkeit häufig als ineffizient eingeschätzt. Als Alternative sollen die natürlichen Abbauprozesse im Grundwasserleiter genutzt oder gezielt verstärkt werden, um auf diesem Weg eine in-situ-Sanierung des Grundwasserleiters zu erreichen. In den letzten Jahren haben sich verschiedene Sanierungsverfahren etabliert, bei denen durch die Zugabe von Hilfsstoffen die mikrobiologische Aktivität des Aquifers erhöht wird bzw. Stoffe zugeführt werden, die mit den Schadstoffen reagieren (in-situ chemische Oxidation bzw. Reduktion, ISCO). An ausgewählten Standorten ist auch die aktive Sanierung (pump & treat, on-site- Sanierung) mit biologischem Schadstoffabbau (Bio-Filter) kombiniert worden. Um den Sanierungsverlauf zu verfolgen und zu optimieren, ist die Beprobung von Grundwasser aus dem Grundwasserleiter oder aus laufenden Anlagen erforderlich. In Fällen der gesteigerten mikrobiologischen Aktivität des Grundwassers treten gehäuft Probleme bei der Stabilisierung der Wasserproben auf. Die forcierten Abbauprozesse der Schadstoffe gehen nach der Probenahme in der Probenflasche weiter, bis die Energiebasis der Mikrobiologie aufgebraucht ist. Durch eine geringe Temperaturerhöhung beschleunigen sich diese Prozesse zusätzlich. In der Folge können die Schadstoffgehalte teilweise innerhalb weniger Stunden stark reduziert werden. Im Analysenlabor wird dann ein Schadstoffgehalt nachgewiesen, der nicht mehr die Verhältnisse im Aquifer bzw. im Ablauf der Reinigungsstufen widerspiegelt. Eine Einschätzung des Sanierungsfortschritts oder der Reinigungsleistung ist unter diesen Bedingungen stark fehlerbehaftet und kann zu groben Fehlinterpretationen führen. Grundwasserproben, die einem Aquifer mit hoher natürlicher oder initiierter mikrobiologischer Abbauaktivität entstammen, müssen daher zusätzlich stabilisiert werden, um den Ist-Zustand zum Zeitpunkt der Probenahme zu erfassen. Die Konservierung von Wasserproben bei der Probenahme von Grundwasser ist in der Normung umfangreich beschrieben: Die EN ISO 5667-3 von 2004 ist im Normausschuss (NA 119-01-03-01-01) überarbeitet und 2012 als Norm verabschiedet worden (EN ISO 5667-3, 03.12, deutsche Fassung DIN EN ISO 5667-3, 03-2013) [1], In Einzelfällen hat sie sich nicht als ausreichend erwiesen, um die Stabilität der organischen Schadstoffe in den oben beschriebenen Wasserproben zu gewährleisten. T2 - Altlastensymposium 2014 CY - Fulda, Germany DA - 20.03.2014 KW - Grundwasser KW - In-situ-Sanierung KW - Probenahme KW - Stabilisierung PY - 2014 SP - 76 EP - 85 AN - OPUS4-30480 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Darstellung der Aktivitäten der BAM auf dem Gebiet der Wasseranalytik T2 - Resortforschungseinrichtungen, AG "Wasser", Themencluster 4, Qualitätssicherung in der Analytik CY - Braunschweig, Germany DA - 2012-09-10 PY - 2012 AN - OPUS4-26443 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Riedel, Juliane A1 - Hofmann, Andrea T1 - Comparison of gas- and liquid chromatography-mass spectrometry for trace analysis of anilines in groundwater N2 - Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines. KW - Interlaboratory comparison KW - Aniline KW - Chloroanilines KW - Methylanilines KW - Groundwater KW - GC/MS KW - GC/MS-MS KW - LC/MS-MS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-535793 DO - https://doi.org/10.1080/03067319.2021.1987423 VL - 103 IS - 19 SP - 8465 EP - 8477 PB - Taylor & Francis CY - London AN - OPUS4-53579 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Dorgerloh, Ute A1 - Win, Tin A1 - Erhardt, Ulla A1 - Hofmann, Andrea A1 - Nehls, Irene A1 - Kuhnhardt, Claus A1 - Schultze, Karin A1 - Witt, Angelika T1 - Bilanzierung der Schwefelbelastung im Grundwasser an einem ausgewählten Industriestandort, Berlin N2 - Die Bundesanstalt für Materialforschung und -prüfung (BAM) ist vom Senat für Stadtentwicklung, Berlin, und von der Bundesanstalt für vereinigungsbedingte Sonderaufgaben (BvS) beauftragt worden, die Bilanzierung der Schwefelkomponenten für ein bis drei ausgewählte Grundwasserproben an einem Berliner Industriestandort vorzunehmen. Es handelt sich bei den Boden- und Grundwasserkontaminationen ausnahmslos um industrielle Altlasten. Da der Gehalt an organisch gebundenen Schwefelverbindungen, kolloidalem Schwefel und gelösten Sulfiden für die Dimensionierung von Grundwasseraufbereitungsanlagen (Aktivkohle, Katalysator) von großer Bedeutung ist und am Standort teilweise sehr hohe Schwefelkontaminationen auftreten, sollen vor einem erneuten Ausschreibungsverfahren zur Grundwassersanierung an drei sehr unterschiedlichen, aber für den Standort typischen Grundwassermessstellen entsprechende Bilanzen für die Schwefelbelastung erstellt werden. Dabei sind sowohl die summarischen Kenngrößen wie Summe Gesamtschwefel, ausblasbare (POS) und extrahierbare leicht- und schwerflüchtige organische Schwefelverbindungen und an Aktivkohle adsorbierbare Schwefelverbindungen (AOS) von Interesse, als auch eine Zuordnung der Hauptkontaminationen über ein halbquantitatives GC-MS-Screening. Im Artikel werden die angewendeten Verfahren vorgestellt. Die Ergebnisse werden diskutiert, gegenübergestellt und ihre Belastbarkeit eingeschätzt. T3 - BAM Forschungsberichtreihe - 265 PY - 2004 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1865 SN - 978-3-86509-182-2 SN - 0938-5533 VL - 265 SP - 1 EP - 20 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-186 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute T1 - Bilanz über 5 Jahre VGS-Ringversuche-organische Parameter in synthetischen Abwasserproben KW - Ringversuche KW - Indirekteinleiter KW - Abwasseranalytik KW - Sollwertgebung KW - Verfahrenskenndaten PY - 2001 SN - 0083-6915 N1 - Sprachen: Deutsch/Englisch - Languages: German/English IS - 96 SP - 63 EP - 70 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-1084 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. T1 - Bestimmung von Wasserstoff, Methan, Ethen und LCKW in Grundwasser: Probenahme und Analytik aus behördlicher Sicht T2 - Informations- und Weiterbildungsveranstaltung des Senats Berlin für Mitarbeiter der Umweltbehörden der Bezirksämter und des Senats, Senat Berlin, SenGUV CY - Berlin, Germany DA - 2009-11-30 PY - 2009 AN - OPUS4-20319 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Kaminski, Katja A1 - Nehls, Irene T1 - Bestimmung von extrem leicht flüchtigen Komponenten in Grundwasser T2 - GDCh Jahrestagung CY - Osnabrück, Germany DA - 2007-09-26 PY - 2007 AN - OPUS4-15876 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Kaminski, Katja T1 - Bestimmung extrem leicht flüchtiger Komponenten in Grundwasser T2 - GDCh-Tagung, Wasserchemische Gesellschaft CY - Passau, Germany DA - 2007-05-14 PY - 2007 AN - OPUS4-14483 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Witt, Angelika A1 - Nehls, Irene A1 - Bernstorff, A. T1 - Bestimmung der ausblasbaren Schwefelkomponenten (POS) in belastetem Grundwasser T2 - GDCh Tagung CY - Halle (Saale), Germany DA - 2006-10-04 PY - 2006 AN - OPUS4-12686 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Witt, Angelika A1 - Nehls, Irene A1 - Bernstorff, A. T1 - Bestimmung der ausblasbaren Schwefelkomponenten (POS) in belastetem Grundwasser T2 - IGAS Jahrestagung CY - Berlin, Germany DA - 2005-11-08 PY - 2005 AN - OPUS4-10981 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Witt, Angelika A1 - Nehls, Irene A1 - Bernstorff, A. T1 - Bestimmung der ausblasbaren Schwefelkomponenten (POS) in belastetem Grundwasser T2 - Tag der Chemie 2005, Freie Universität Berlin CY - Berlin, Germany DA - 2005-06-08 PY - 2005 AN - OPUS4-7517 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Witt, Angelika A1 - Nehls, Irene T1 - Bestimmung der ausblasbaren Schwefelkomponenten (POS) in belastetem Grundwasser T2 - ANAKON 2005 CY - Regensburg, Germany DA - 2005-03-15 PY - 2005 AN - OPUS4-5878 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Theißen, H. T1 - Besteht auf Normungsebene Bedarf zur Stabilisierung von Grundwasser? T2 - Stabilisierung von Grundwasserproben zur Bestimmung organischer Schadstoffe CY - Berlin, Germany DA - 2013-02-22 PY - 2013 AN - OPUS4-27712 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Fritz, Thomas A1 - Schmieder, Rosmarie T1 - BAM-Ringversuch zur Bestimmung von leichtflüchtigen halogenierten Kohlenwasserstoffen in synthetischen Abwasserproben T2 - Umwelttagung GDCh CY - Ulm, Germany DA - 1996-10-07 PY - 1996 AN - OPUS4-5668 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Lutz, A. T1 - BAM Ringversuch Aniline 2018 Qualitätssicherung Grundwassermonitoring ÖGP N2 - Im Rahmen des Ökologischen Großprojekts "Industriegebiet Spree" der Senatsverwaltung für Umwelt, Verkehr und Klimaschutz (SenUVK), Berlin, wurde als Überwachungssystem für laufende Gefahrenabwehr- und Sanierungsmaßnahmen ein Grundwasser-Monitoring eingerichtet. Die Maßnahmen zur externen Qualitätssicherung der Laborarbeiten im Monitoring werden zusammenfassend dargestellt. Um einen vergleichbaren und hohen Qualitätsstandard der Analytik zu gewährleisten, ist die Ausschreibung der analytischen Leistungen in diesem Projekt direkt an die Teilnahme an einem Ringversuch zur Bestimmung von Anilin und Anilinderivaten in Wasser gekoppelt. Die Ergebnisse des Ringversuchs werden im Einzelnen vorgestellt. T2 - Informationsveranstaltung CY - Berlin, Germany DA - 08.03.18 KW - Ringversuch KW - Aniline KW - Grundwasser PY - 2018 AN - OPUS4-44422 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Auswirkungen der externen Qualitätssicherung auf die Altlastenbearbeitung im Land Berlin T2 - Altlastensymposium 2013 CY - Berlin, Germany DA - 2013-06-29 KW - Grundwassermonitoring KW - Qualitätssicherung KW - Ökologisches Großprojekt Berlin PY - 2013 SP - 99 EP - 107 CY - Berlin AN - OPUS4-29138 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Auswirkungen der analytischen Qualitätssicherung auf die Altlastenbearbeitung im Land Berlin T2 - Altlastensymposium Berlin 2013 CY - Berlin, Germany DA - 2013-08-29 PY - 2013 AN - OPUS4-28279 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Auswertungsveranstaltung zum 19. und 20. VGS-Ringversuch "Organische Parameter" T2 - BAM/DAP CY - Berlin, Germany DA - 2000-03-16 PY - 2000 AN - OPUS4-5751 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Auswertung des 15. und 16. VGS-Ringversuhces - Organische Parameter T2 - Bundesanstalt für Materialforschung und /-Prüfung CY - Berlin, Germany DA - 1998-03-12 PY - 1998 AN - OPUS4-5685 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute T1 - Auswertung 17. und 18. VGS-Ringversuch; Organische Parameter T2 - BAM/DAP CY - Berlin, Germany DA - 1999-03-10 PY - 1999 AN - OPUS4-5709 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Win, Tin T1 - Ableitung validierter Probenahme und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von Leichtflüchtigen Chlorierten Kohlenwasserstoffen (LCKW) im Grundwasser im Rahmen von Altlastenuntersuchungen N2 - Im vorliegenden Forschungsbericht werden die Ergebnisse zum LFP Projekt „Ableitung validierter Probenahme- und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von LCKW im Grundwasser im Rahmen von Altlastenuntersuchungen“ (Länderfinanzierungsprogramm, Projekt B2/08, Laufzeit vom 01.09.2008 – 31.08.2009) zusammengefasst. Es werden verschiedene Verfahren der Probenahme und Analytik zur Bestimmung von Wasserstoff, Methan, Ethen und Vinylchlorid (VC) im Grundwasser untersucht und validiert. Für die Probenahme werden folgende Ansätze beschrieben und diskutiert: i. aktive Probenahme: Pumpprobe und Probenahme von in Grundwasser gelösten Gasen in Gasbeprobungsrohren (Gasmaus) ii. passive Probenahme: Diffusionsprobenahme in Polyethylenbeuteln (PDB) und Kunststoffspritzen als Diffusionssammler für gelöste Gase Der Einsatz aktiver (Pumpprobenahme, Schöpfprobenahme) und passiver (Diffusionsprobenahme) Probenahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probenahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probenahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Die chromatographischen Verfahren zur Bestimmung der Analyte werden umfänglich validiert und mit anderen geeigneten Analysenverfahren verglichen: I. Headspace-GC-FID zur Bestimmung von Methan, Ethen und VC aus der wässrigen Probenmatrix der Pumpprobe (i.) und des PDB (ii.) II. Direktinjektion-GC-PDD zur Bestimmung von Wasserstoff aus den gesammelten Gasproben der Gasmaus (i.) und der Kunststoffspritzen (ii.) Für die Bestimmung von Ethen und VC in Grundwasserproben (I.) werden Bestimmungsgrenzen von 0,1 μg/L erreicht. Methan kann aus wässrigen Proben nur ab 5 μg/L quantifiziert werden. Mit den Verfahren zur Bestimmung von Methan aus der Gasmaus (i.-II.) werden 0,1 μg/L im Grundwasser erreicht. Die Bestimmung von im Grundwasser gelösten Wasserstoff (II.) ist bis zu einer Konzentration von 1 nM möglich. Die Reproduzierbarkeit für die Bestimmung von Wasserstoff in Grundwasser liegt konzentrationsabhängig zwischen 10 bis 20% bei der aktiven Probenahme (i.-II.) und 10 bis 70% bei der passiven Probenahme (ii.-II.). Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probenahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring-Ergebnissen sollten von Ingenieurbüros und zuständige Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden. T3 - BAM Forschungsberichtreihe - 290 PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1610 SN - 978-3-9813346-5-4 SN - 0938-5533 VL - 290 SP - 1 EP - 121 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-161 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -