TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Sauer, Andreas A1 - Hofmann, Andrea T1 - Quality control in extended measurement campaigns: selection of contract laboratories by proficiency testing exemplified for the trace analysis of anilines in groundwater JF - Accreditation and quality assurance N2 - An interlaboratory comparison for the determination of aniline, nine methylated anilines and chlorinated anilines in contaminated groundwater (each compound between 1 µg L-1 and 750 µg L-1) was conducted as proficiency test for the selection of contract laboratories for a groundwater monitoring campaign. For the 13 participants, two different test sample series were prepared from a stabilized real case groundwater. Series A was the groundwater as sampled in the field and series B was prepared from series A by spiking with selected anilines. Homogeneity and stability investigations revealed that contaminated groundwater provides a viable basis for the preparation of ring test samples for the determination of anilines. Analytical procedures were limited to the standardized liquid–liquid extraction or solid-phase extraction in combination with gas chromatography/mass spectrometry (DIN 38407-16:1999). The robust consensus values were evaluated according to the standardized protocol of DIN 38402-45:2013. Robust reproducibility standard deviations ranged largely between 20?% and 60?% depending on the analyte. The proficiency assessment of individual participants combined the qualitative aspect of correct peak identification with the quantitative determination of individual concentrations within set limits in a unified approach. It could be shown that the accreditation status of laboratory and the existence of a standardized analytical procedure do not substitute a problem-related proficiency assessment of potential contractors. KW - Aniline KW - Chloroanilines KW - Methylanilines KW - Groundwater KW - Interlaboratory comparison KW - Proficiency test PY - 2014 DO - https://doi.org/10.1007/s00769-014-1072-5 SN - 0949-1775 SN - 1432-0517 N1 - Geburtsname von Sauer, Andreas: Buchholz, A. - Birth name of Sauer, Andreas: Buchholz, A. VL - 19 IS - 5 SP - 371 EP - 376 PB - Springer CY - Berlin AN - OPUS4-31756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Riedel, Juliane A1 - Hofmann, Andrea T1 - Comparison of gas- and liquid chromatography-mass spectrometry for trace analysis of anilines in groundwater JF - International Journal of Environmental Analytical Chemistry N2 - Three chromatographic procedures were investigated regarding their potential for the quantification of aniline and 19 of its methylated and chlorinated derivatives in groundwater. These methods were based on liquid-liquid-extraction in combination with gas chromatography and single quadrupole mass spectrometry (GC/MS) according to German standard DIN 38407-16:1999 and its extension using tandem mass spectrometry (GC/MS-MS), both following liquid-liquid extraction, and as third alternative the direct injection of the water sample into a liquid chromatograph coupled to tandem mass spectrometry (LC/MS-MS). Results were compared using fortified water and real-world contaminated groundwater used in an interlaboratory comparison. It could be shown that GC/MS and GC/MS-MS yielded results deviating less than 10% from each other while all three procedure displayed quantification results deviating less than 15% from the intercomparison reference values in case of each analyte in the concentration range between 1 and 45 µg L-1. Though GC/MS-MS displays a ten-fold higher sensitivity than single quadrupole GC/MS, the precision of both methods in the concentration range was similar. LC/MS-MS has the advantage of no further sample preparation due to the direct injection and leads for methylanilines and meta-, para- substituted chloroanilines to results sufficiently equivalent to the standardised GC/MS method. However, LC/MS-MS is not suitable for ortho-chloroaniline derivates due to significantly lower ion yields than meta- and para-substituted chloroanilines. KW - Interlaboratory comparison KW - Aniline KW - Chloroanilines KW - Methylanilines KW - Groundwater KW - GC/MS KW - GC/MS-MS KW - LC/MS-MS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-535793 DO - https://doi.org/10.1080/03067319.2021.1987423 VL - 103 IS - 19 SP - 8465 EP - 8477 PB - Taylor & Francis CY - London AN - OPUS4-53579 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dorgerloh, Ute A1 - Lutz, A. T1 - BAM Ringversuch Aniline 2018 Qualitätssicherung Grundwassermonitoring ÖGP N2 - Im Rahmen des Ökologischen Großprojekts "Industriegebiet Spree" der Senatsverwaltung für Umwelt, Verkehr und Klimaschutz (SenUVK), Berlin, wurde als Überwachungssystem für laufende Gefahrenabwehr- und Sanierungsmaßnahmen ein Grundwasser-Monitoring eingerichtet. Die Maßnahmen zur externen Qualitätssicherung der Laborarbeiten im Monitoring werden zusammenfassend dargestellt. Um einen vergleichbaren und hohen Qualitätsstandard der Analytik zu gewährleisten, ist die Ausschreibung der analytischen Leistungen in diesem Projekt direkt an die Teilnahme an einem Ringversuch zur Bestimmung von Anilin und Anilinderivaten in Wasser gekoppelt. Die Ergebnisse des Ringversuchs werden im Einzelnen vorgestellt. T2 - Informationsveranstaltung CY - Berlin, Germany DA - 08.03.18 KW - Ringversuch KW - Aniline KW - Grundwasser PY - 2018 AN - OPUS4-44422 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -