TY - JOUR A1 - Johann, Sergej A1 - Baensch, Franziska A1 - Sturm, Patrick A1 - Tiebe, Carlo A1 - Pötschke, Samuel A1 - Lay, Vera ED - Holl, H. T1 - HF RFID-based measurement comparison for method optimization in M2 concrete and alkali-activated mortars N2 - Monitoring of repositories for radioactive waste requires techniques which can be applied long-term under harsh conditions. In this work, the reliability and suitability of materials and a capacitive sensor for measuring relative humidity are investigated, which are to be embedded in the special concrete components for the closure structures of underground repository. Preliminary tests with accelerated aging of the materials used, validation of the sensors under difficult conditions, investigations of the surfaces after aging by pH 14 solution, defined exposure of the sensors in a climatic chamber and the microscope images are discussed. The results will be used for further development and optimization of the RFID based sensor systems which can be applied to monitor the condition of different building structures without cabling. T2 - 37th Danubia - Adria Symposium on Advances in Experimental Mechanics CY - Linz, Austria DA - 21.09.2021 KW - Alkali-activated mortars KW - Passive sensor interface KW - RFID KW - Structural health monitoring KW - Smart structures PY - 2022 DO - https://doi.org/10.1016/j.matpr.2022.03.465 SN - 2214-7853 VL - 62 IS - 5 SP - 2571 EP - 2576 PB - Elsevier CY - Amsterdam AN - OPUS4-54697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sarif, Raduan A1 - Tiebe, Carlo A1 - Herglotz, Christian T1 - Early Response Prediction for H2 Sensors N2 - Green hydrogen (H2) is essential for the global transition to clean energy; it will significantly reduce emissions from heavy industry and the long-distance transport system. H2 can be used as fuel in fuel cells, storing surplus renewable energy, and as a feedstock in industrial processes. However, H2 faces significant safety challenges during storage and transportation. Accidents due to H2 leakage and explosions raise serious concerns due to its high flammability, rapid diffusion in air, and extremely low ignition energy. To mitigate risks associated with H2 leakages, reliable and automated H2 safety systems are essential for emergency repairs or shutdown. An early response from H2 sensors is crucial for early warning in accidents. The earlier response time of H2 sensors is often constrained by their sensor principle, which is heavily influenced by the sensor material’s properties. This study explores methods for earlier sensor response through predictive algorithms. Specifically, we investigate transient response predictions using a First-Order (FO) model and propose improvements through the First-Order with early response and the First-Order with adapted early response model. Both models can predict the stable value of the H2 sensor response from a small time window, which is 70.89% and 83.72% earlier, respectively, than the time required for the sensor hardware to reach it physically. The model’s performance is evaluated by calculating the fitting error with a 2 % threshold. Our current research lays the groundwork for future advancements in real-time sensor response predictions for hydrogen leakage. T2 - IARIA Congress 2025 : The 2025 IARIA Annual Congress on Frontiers in Science, Technology, Services, and Applications CY - Venice, Italy DA - 06.07.2025 KW - H2 Safety KW - H2 leakage detection KW - First-Order (FO) model KW - H2 Sensor data analysis KW - H2 sensor response predictions PY - 2025 AN - OPUS4-64195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Gawlitza, Kornelia T1 - Gas standards for the calibration of novel fluorescence sensors for ammonia N2 - Ammonia and its conversion product ammonium have a strong negative impact on human health and ecosystems. Most ammonia measurements in ambient air are performed in the molar fraction range (0.5 to 500) nmol/mol. There is a need for reliable traceable ammonia gas standards as well as in situ analytical procedures for the monitoring of ammonia in ambient air. The permeation method is an effective tool for dynamically generating precise gas standards with a low uncertainty in the concentration range of a few nmol/mol to several µmol/mol in an inert carrier gas, e. g. pure nitrogen or purified ambient air. Here, we present our ammonia gas standard generator as well as results of the characterisation of its individual components supporting the uncertainty assessment according to GUM for stable gas concentrations in this range. In order to detect ammonia in the nmol/mol-range, a suitable sensor has to be developed. In this contribution, we therefore additionally present first approaches on the development of such a sensor using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution. Incorporation of a fluorescent dye, which shows fluorescence enhancement in the presence of ammonia, into a polymer matrix allows to reversibly recognize low amounts of ammonia. It can be concluded that fluorescence sensor is a robust tool for measurements of ammonia; however it needs calibration for the planed use. T2 - MetNH3-workshop on the progress in ammonia metrology CY - Braunschweig, Germany DA - 24.02.2016 KW - Ammonia KW - Fluorescence sensor KW - Permeation KW - Test gas generation PY - 2016 AN - OPUS4-35810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Detjens, Marc A1 - Tiebe, Carlo A1 - Banach, Ulrich T1 - Influence of Gas Pressure on Coulometric Trace Humidity Measurement N2 - Planar coulometric sensors were investigated in humidified synthetic air at various absolute gas pressures, i. e. 2 bar, 5, bar, 10 bar, and 15 bar. Humidified gas flow at adjusted gas pressure was split into two flows, one passed a coulometric sensor and the other one passed a reference hygrometer after decompression. Both signals were recorded and then compared after calculation of resulting frost point temperature. Calculation is based on a calibration function obtained at ambient pressure. Comparison showed that an increasing pressure resulted in a higher derivation between sensor signal (calculated frost point temperature) and reference frost point temperature. At an absolute pressure of 2 bar the differences were minor in consideration of the uncertainty, however at 15 bar the differences were 6.77 K. Nevertheless, it was possible to measure the gas humidity at higher pressure with coulometric trace humidity sensors. T2 - 17th International Meeting of Chemical Sensors, IMCS 2018 CY - Vienna, Austria DA - 15.07.2018 KW - Gas pressure influence KW - Coulometric sensors KW - Trace humidity measurement PY - 2018 SN - 978-3-9816876-9-9 DO - https://doi.org/10.5162/IMCS2018/P2EC.7 SP - 715 EP - 716 PB - AMA Service GmbH CY - Wunstorf / Germany AN - OPUS4-45539 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neumann, Patrick P. A1 - Tiebe, Carlo A1 - Bartholmai, Matthias T1 - Airborne Remote Gas Sensing and Mapping N2 - Leaking methane (CH4) from infrastructures, such as pipelines and landfills, is critical for the environment but can also pose a safety risk. To enable a fast detection and localization of these kind of leaks, we developed a novel robotic platform for aerial remote gas sensing. Spectroscopic measurement methods for remote sensing of selected gases lend themselves for use on mini-copters, which offer a number of advantages for inspection and surveillance over traditional methods. No direct contact with the target gas is needed and thus the influence of the aerial platform on the measured gas plume can be kept to a minimum. This allows to overcome one of the major issues with gas-sensitive mini-copters. On the other hand, remote gas sensors, most prominently Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensors have been too bulky given the payload and energy restrictions of mini-copters. Here, we present the Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS), which combines a novel lightweight TDLAS sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile hexacopter. The proposed system can be deployed in scenarios that cannot be addressed by currently available robots and thus constitutes a significant step forward for the field of Mobile Robot Olfaction (MRO). It enables tomographic reconstruction of gas plumes and a localization of gas sources. We also present first results showing its performance under realistic conditions. T2 - Networked Environmental Monitoring – from sensor principles to novel services CY - BAM, Berlin, Germany DA - 06.02.2018 KW - Localization of gas sources KW - Mobile Robot Olfaction KW - Tomographic reconstruction of gas plumes KW - Tunable Diode Laser Absorption Spectroscopy (TDLAS) KW - UAV-REGAS PY - 2018 AN - OPUS4-44085 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Testing of Gas and Humidity Sensors N2 - The testing of gas and humidity sensors is essential for the application of sensing devices. The testing determines properties of an investigated humidity sensor or gas sensor. In testing, the sensor property is the observed response of a sensing system to an input stimulus in comparison to a reference within a test procedure. This tutorial is structured into six chapters. The first chapter is about basics of hygrometry and gas sensing. It includes definitions, sensor classification, overview of application categories, as well as construction and functional principles. The chapter on requirements of deployed sensors focus on stability, response time, cross-sensitivity, electrical and mechanical requirements, and other. The sensing performance is characterised by determinations of parameters like accuracy, repeatability, detection limits (low and high), and response/recovery time. The description of testing signals on specified qualitative and quantitative characteristics, and the adequately estimated measurement uncertainty is the content of the analysis chapter. All chapters contain examples of testing procedures from testing/calibration labs for hygrometers and gas sensors which are essential for implementation into quality management systems. T2 - SMSI 2021 - Sensor and Measurement Science International CY - Online m DA - 03.05.2021 KW - Testing KW - Gas sensor KW - Humidity sensor KW - Tutorial KW - Multi-gas sensor PY - 2021 UR - https://www.smsi-conference.com/tutorials-2/ AN - OPUS4-52645 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Hydrogen sensing - Sensors for safety and process control in Hydrogentechnologies N2 - The success of this energy transition and the efficient utilization of green hydrogen as a pristine energy carrier hinge upon the cultivation of hydrogen readiness, swift market expansion, and the establishment of crucial value chains within national and European contexts. Paramount to these objectives are reliable quality and safety standards, essential for ensuring supply safety, environmental compatibility, and instilling confidence in these technologies. In the realm of safety management systems, gas sensors emerge as vital components for detecting hydrogen. This presentation delves into the imperative role of hydrogen systems, emphasizing their capability to monitor and control operations, issue warnings, signal hazardous conditions, and sound alarms. It explores the intricate landscape of functional safety considerations and addresses the challenges associated with measurement uncertainty in sensor testing. A diverse array of sensors catering to hydrogen, pressure, temperature, and flow are available, each contributing significantly to the safety and efficiency of hydrogen technologies. Applications are envisaged to adhere meticulously to quality infrastructural regulations, codes, and standards, ensuring seamless integration and operation within the broader hydrogen ecosystem. This discussion underscores the ubiquitous presence of sensor systems across various fields within hydrogen technologies, illustrating their multifaceted contributions to safety, reliability, and overall success in realizing the transformative potential of green hydrogen. T2 - Joint European Summer School 2023 on Fuel Cell, Electrolyser, and Battery Technologies CY - Vravrona, Greece DA - 17.09.2023 KW - H2Safety@BAM KW - SensRef KW - Hydrogen KW - KICstartH2 KW - Gas detection KW - Sensor testing KW - Hydrogen gas sensor PY - 2023 AN - OPUS4-59228 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Error Prevention, Damage Prevention, and Safety Management in Hydrogen Technologies N2 - In order to integrate the error prevention and damage prevention strategy into hydrogen technologies, it is important to proactively look out for potential weaknesses in the systems and processes. This includes the implementation of preventive measures as elements of safety management in order to identify and eliminate potential sources of error. In addition, training should be specifically focussed on avoiding errors and the safe use of hydrogen technologies. The principial approach of a gas sensor testing laboratory shows how to ensure reliable results, it is advisable to conduct sensor testing under controlled conditions, focusing on identifying specific properties and quantifying performance criteria. A well thought-out strategy for error prevention makes a significant contribution to preventing accidents and increasing overall safety when using hydrogen. T2 - 5th Germany-Korea Hydrogen Conference CY - Halle (Saale), Germany DA - 22.10.2024 KW - Hydrogen KW - Safety KW - Safety Management KW - Error Prevention KW - Reference Procedure PY - 2024 AN - OPUS4-62563 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Maiwald, Michael A1 - Schukar, Marcus T1 - Beiträge der Prozessanalytik und Sensorik zur Sicherheit in Wasserstofftechnologien N2 - Intelligent sensor systems, certified reference materials and instrumental analytical-chemical methods contribute to safety and functionality in hydrogen technologies. This article gives a brief overview of SensRef activities in the Competence Centre H2Safety@BAM on the issues: Analytical methods for the determination of hydrogen purity, certified reference materials as measurement standards with regard to gas quality (primary calibrators) of BAM, test methods for gas sensor systems to detect hydrogen in air as well as the application of fibre-optic sensor systems to monitor the expansion and ageing behaviour of composite containers in hydrogen technologies. T2 - Berlin Brandenburger Optik-Tag "Einsatz von Sensorik und Mikroelektronik in der Wasserstoffwirtschaft" CY - Online meeting DA - 29.11.2021 KW - H2Safety@BAM KW - SensRef KW - Gas analysis KW - Gas purity KW - Fibre-optic sensors KW - Sensor response KW - Certified reference materials PY - 2021 AN - OPUS4-54138 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nattuveettil, Keerthana A1 - Liebner, Christian A1 - Tiebe, Carlo T1 - Federal Institute for Material Research and Testing: Role in Hydrogen Safety N2 - An introduction to the Federal Institute for Materials Research and Testing (BAM) and its role in hydrogen safety is provided. The study further describes a hydrogen safety experiment in which the detection and monitoring of hydrogen in confined environments were investigated. A sensor network–based approach was implemented to reduce the risk of hazardous mixture formation, with focus placed on sensor placement, data collection, and the resulting safety improvements. T2 - Hybrid Sensor Network Open Forum 2025 CY - Karlsruhe, Germany DA - 26.06.2025 KW - Sensor Network KW - Hydrogen safety KW - QI-Digital PY - 2025 AN - OPUS4-64042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Introduction of H2Safety@BAM N2 - This contribution for the Open Forum of the 8th HSN Symposium introduces the SensRef activities of the Competence Centre H2Safety@BAM. T2 - 8. HSN-Symposium - HybridSensorNet e. V. CY - Online meeting DA - 11.11.2021 KW - H2Safety@BAM KW - SensRef KW - Hydrogen PY - 2021 AN - OPUS4-54137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Hydrogen Sensing - Sensors for Safety and Process Control in Hydrogen Technologies N2 - The success of this energy transition and the efficient utilization of green hydrogen as a pristine energy carrier hinge upon the cultivation of hydrogen readiness, swift market expansion, and the establishment of crucial value chains within national and European contexts. Paramount to these objectives are reliable quality and safety standards, essential for ensuring supply safety, environmental compatibility, and instilling confidence in these technologies. In the realm of safety management systems, gas sensors emerge as vital components for detecting hydrogen. This presentation delves into the imperative role of hydrogen systems, emphasizing their capability to monitor and control operations, issue warnings, signal hazardous conditions, and sound alarms. It explores the intricate landscape of functional safety considerations and addresses the challenges associated with measurement uncertainty in sensor testing. A diverse array of sensors catering to hydrogen, pressure, temperature, and flow are available, each contributing significantly to the safety and efficiency of hydrogen technologies. Applications are envisaged to adhere meticulously to quality infrastructural regulations, codes, and standards, ensuring seamless integration and operation within the broader hydrogen ecosystem. This discussion underscores the ubiquitous presence of sensor systems across various fields within hydrogen technologies, illustrating their multifaceted contributions to safety, reliability, and overall success in realizing the transformative potential of green hydrogen. T2 - Joint European Summer School JESS 2024 CY - Vravrona, Greece DA - 16.09.2024 KW - H2Safety@BAM KW - Hydrogen KW - Sensor KW - Sensor technology KW - Safety KW - Process control PY - 2024 AN - OPUS4-61677 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sarif, Raduan A1 - Tiebe, Carlo A1 - Herglotz, Christian T1 - Analysis of Methods for Predicting H2 Sensor Responses N2 - Hydrogen (H2) is crucial for replacing fossil fuels and achieving net-zero emissions, but its flammability and explosiveness pose safety challenges. Rapid H2 leak detection is essential for triggering emergency accidents. However, H2 sensor response is constrained by material properties and gas flow dynamics, causing response and detection delays. Our current study explores various available algorithms for H2 sensor response prediction from early responses with a small time window, accelerating leakage detection. Our findings identify the most efficient algorithms for real-time implementation, enhancing H2 safety systems. T2 - SMSI 2025 Conference – Sensor and Measurement Science International CY - Nuremberg, Germany DA - 06.05.2025 KW - H2 safety KW - Early H2 leakage detection KW - Prediction algorithms KW - Stable H2 value prediction PY - 2025 AN - OPUS4-64194 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Multigassensoren - Standardisierte Prüfanweisung und Prüfgase für VOC-Detektoren zur Innenraumluftgütemessung N2 - Flüchtige organische Verbindungen (VOC, "Volatile Organic Compounds") sind ein wichtiger Parameter zur Bewertung der Luftqualität speziell in Innenräumen. Deren Bestimmung ist vergleichsweise komplex, da VOC ein Oberbegriff für viele verschiedene Verbindungen ist. Die Richtlinie VDI/VDE 3518 Blatt 4[1] (Entwurf) beschreibt eine vom Messprinzip unabhängige Prüfung sowie sinnvolle Prüfgasmischungen für VOC-Detektoren. Die Richtlinie schafft die Basis für vergleichbare Messungen mit Sensoren und Messsystemen für die Bestimmung von VOC Konzentrationen in Innenräumen. T2 - 22. GMA/ITG- Fachtagung Sensoren und Messsysteme 2024 CY - Nuremberg, Germany DA - 11.06.2024 KW - Richtlinie KW - VOC KW - VOC-Detektion KW - Innenraumluftgüte PY - 2024 AN - OPUS4-61675 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tahri, K. A1 - Tiebe, Carlo A1 - Bougrini, M. A1 - Saidi, T. A1 - El Alami El Hassani, N. A1 - El Bari, N. A1 - Hübert, Thomas A1 - Bouchikhi, B. T1 - Characterization and discrimination of saffron by multisensory systems, SPME-GC-MS and UV-Vis spectrophotometry N2 - Different electronic sensor systems coupled with multivariate data analysis were applied to characterize and classify seven saffron samples and to verify their declared geographical origin. The proposed electronic sensing consists of a low-cost electronic nose (E-nose) based on metal oxide semiconductor sensors and a voltammetric electronic tongue (VE-tongue) based on voltammetric sensors. The ability of multivariable analysis methods such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA) and Support Vector Machines (SVMs) to classify the saffron samples according to their geographical origin have been investigated. Both PCA and HCA have shown an overlapping of E-nose responses. Moreover, the SVM analysis of the E-nose database reached a 66.07% success rate in the recognition of the saffron sample odour. On the other hand, good discrimination has been reached using PCA and HCA in the VE-tongue characterization case, besides a 100% accuracy in the saffron flavour recognition was attained. To validate the proposed electronic sensing systems, analytical chemical methods such as SPME-GC-MS and UV-Vis spectrophotometry were used. These analytical methods could be helpful tools to identify the composition of volatile compounds of the analysed saffron samples. Moreover, UV-Vis spectrophotometry was also used to determine the non-volatile profile of the samples from different geographic origins. It is demonstrated that the electronic sensing systems' findings are in a satisfactory correlation with the analytical methods. In the light of these results, we might say that the electronic systems offer a fast, simple and efficient tool to recognize the declared geographical origin of the saffron samples. KW - Electronic nose KW - Voltammetric electronic tongue KW - SPME-GC-MS KW - UV-vis spectrophotometry KW - Saffron KW - Geographic differentiation KW - Multivariable analysis PY - 2015 DO - https://doi.org/10.1039/C5AY01986A SN - 1759-9660 SN - 1759-9679 VL - 7 IS - 24 SP - 10328 EP - 10338 PB - RSC Publ. CY - Cambridge AN - OPUS4-35174 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Melzer, Michael T1 - Sensors for safety and process control in hydrogen technologies - Part II - Seminar about the expression of uncertainty in measurement N2 - The determination of the measurement uncertainty of quantitative and qualitative results is an important quality management tool, for example to describe measuring equipment, procedures, measurement results and the quality of products. The lecture presents the process description for the determination of the measurement uncertainty according to GUM, the determination of uncertainties in qualitative measurement results and the application of the measurement uncertainty for conformity assessment. T2 - Joint European Summer School 2021 on Fuel Cell, Electrolyser, and Battery Technologies CY - Online meeting DA - 12.09.2021 KW - Quality management tool KW - Measurement uncertainty KW - Quantiative results KW - Qualitative results KW - Conformity assessment PY - 2021 AN - OPUS4-54132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Sensors for safety and process control in hydrogen technologies N2 - Sensor systems are widely used in hydrogen technologies. The lecture presents requirements and properties of sensor systems and shows application examples of these technologies for safety and process control for hydrogen technologies. The focus is on gas sensors as well as sensors for pressure, temperature and gas flow. These systems are applied, among other things, for monitoring and control of operating conditions, indication of hazardous conditions and triggering of alarms. T2 - Joint European Summer School 2021 on Fuel Cell, Electrolyser, and Battery Technologies CY - Online meeting DA - 12.09.2021 KW - Sensor KW - Safety KW - Process control KW - Hydrogen technologies PY - 2021 AN - OPUS4-54131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Development of a device for staged determination of water activity and moisture content N2 - Moisture content and water activity are important parameters of product characterization; thus, an exact determination is necessarily required in a wide range of industrial applications. Moisture content of materials is the content of non-chemically bound water in a solid or liquid. Water activity (aW) is a characteristic/parameter of the non-chemically bound ("free") water in materials and is measured as humidity over a solid/liquid surface at constant temperature (equilibrium moisture content). It is an important parameter to characterize the quality of pharmaceutical and food products. In our contribution, we present a developed device for staged determination of water activity and moisture content of liquid and solid materials. T2 - Eurosensors 2018 CY - Graz, Austria DA - 09.09.2018 KW - Water activity KW - Moisture content KW - Measuring cell KW - Sorption isotherm PY - 2018 AN - OPUS4-45943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo T1 - Fehlervermeidung, Schadenverhütung und Sicherheitsmanagement in der Wasserstofftechnologie N2 - Um den Aspekt der Strategie zur Fehlervermeidung und Schadenprävention in Wasserstofftechnologien zu integrieren, ist es entscheidend, proaktiv auf potenzielle Schwachstellen in den Systemen und Prozessen zu achten. Dies beinhaltet die Implementierung von präventiven Maßnahmen als Elemente des Sicherheitsmanagements, um mögliche Fehlerquellen zu identifizieren und zu eliminieren. Darüber hinaus sollten Schulungen gezielt auf die Vermeidung von Fehlern und die sichere Anwendung von Wasserstofftechnologien ausgerichtet sein. Eine durchdachte Strategie zur Fehlervermeidung trägt wesentlich dazu bei, Unfälle zu verhindern und die Gesamtsicherheit bei der Nutzung von Wasserstoff zu erhöhen. T2 - Forum Schadenverhütung am 12.10.2023 der Arbeitsgemeinschaft Berlin Brandenburg (AGS) in Kooperation mit der AGBB Berlin e.V CY - Berlin, Germany DA - 12.10.2023 KW - H2Safety@BAM KW - Gassensorik KW - Wasserstoff KW - Fehlervermeidung KW - Schadenverhütung KW - Sicherheitsmanagement PY - 2023 AN - OPUS4-59226 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bayat, Mehmet Emin A1 - Nandayapa, Edgar R. A1 - Tiebe, Carlo A1 - Unger, Eva L. A1 - List-Kratochvil, Emil J. W. T1 - Raw data from: "An operando spectroscopic examination of the influence of trace humidity on interdigital back contact metal halide perovskite solar cells" N2 - Controlling trace humidity is vital for both the fabrication and long-term stability of metal halide perovskite (MHP) solar cells. Relevant humidity levels are typically below 10 ppmV, especially in glovebox-based processing and in well-encapsulated devices. Even minute amounts during fabrication can influence crystallization, introducing defects and lowering efficiency. Over time, humidity accelerates degradation of the perovskite layer and internal interfaces, ultimately reducing operational lifetime. Probing these effects at low concentrations under operando conditions is therefore essential for advancing device performance and durability. In this work, we employed a high-precision transfer standard dew point hygrometer to investigate humidity levels between 5 and 35 ppmV in non-encapsulated MHP solar cells. To permit unobstructed water migration during operation, we fabricated interdigital back contact devices. Operando measurements revealed water transport through the perovskite layer and enabled quantification of outgassing. Under trace-humidified conditions, devices exhibited initial charge-carrier quenching, followed by gradual recovery. Notably, the photocurrent response to humidified nitrogen demonstrated that the MHP layer behaves fully reversibly within the explored timescale and across the investigated humidity levels and conditions. These findings establish a systematic operando framework for examining extrinsic stressors in perovskites and highlight opportunities for assessing passivation strategies. KW - Metal halide perovskite PY - 2026 DO - https://doi.org/10.5281/zenodo.18600851 PB - Zenodo CY - Geneva AN - OPUS4-65757 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bayat, Mehmet Emin A1 - Nandayapa, Edgar R. A1 - Tiebe, Carlo A1 - Unger, Eva L. A1 - List-Kratochvil, Emil J. W. T1 - An operando spectroscopic examination of the influence of trace humidity on interdigital back contact metal halide perovskite solar cells N2 - Controlling trace humidity is vital for both the fabrication and long-term stability of metal halide perovskite (MHP) solar cells. Relevant humidity levels are typically below 10 ppmV, especially in glovebox-based processing and in well-encapsulated devices. Even minute amounts during fabrication can influence crystallization, introducing defects and lowering efficiency. Over time, humidity accelerates degradation of the perovskite layer and internal interfaces, ultimately reducing operational lifetime. Probing these effects at low concentrations under operando conditions is therefore essential for advancing device performance and durability. In this work, we employed a high-precision transfer standard dew point hygrometer to investigate humidity levels between 5 and 35 ppmV in non-encapsulated MHP solar cells. To permit unobstructed water migration during operation, we fabricated interdigital back contact devices. Operando measurements revealed water transport through the perovskite layer and enabled quantification of outgassing. Under trace-humidified conditions, devices exhibited initial charge-carrier quenching, followed by gradual recovery. Notably, the photocurrent response to humidified nitrogen demonstrated that the MHP layer behaves fully reversibly within the explored timescale and across the investigated humidity levels and conditions. These findings establish a systematic operando framework for examining extrinsic stressors in perovskites and highlight opportunities for assessing passivation strategies. KW - Metal halide perovskite KW - IBC solar cells KW - In operando KW - Extrinsic stressors KW - Fabrication and encapsulation KW - Trace humidity KW - Two-site Stern-Volmer KW - Charge-carrier quenching PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657560 DO - https://doi.org/10.1039/D6TA01295G SP - 1 EP - 16 PB - The Royal Society of Chemistry CY - London AN - OPUS4-65756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -