TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A. P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.F. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J. L. A1 - Chen, J. A1 - Counsell, J..D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cartazar-Martínez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Shard, A.G. T1 - Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene N2 - We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Intensity scale calibration KW - Reference spectra KW - Low-density polyethylene (LDPE) PY - 2020 DO - https://doi.org/10.1116/6.0000577 VL - 38 IS - 6 SP - 063208 AN - OPUS4-51655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, S.J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A.P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.P. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J.L. A1 - Chen, J. A1 - Counsell, J.D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cortazar-Martinez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Compean-Gonzalez, C.L. A1 - Ceccone, G. A1 - Shard, A.G. T1 - ERRATUM: “Versailles project on advanced materials and standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene” [J. Vac. Sci. Technol. A 38, 063208 (2020)] N2 - The lead authors failed to name two collaborators as co-authors. The authors listed should include: Miss Claudia L. Compean-Gonzalez (ORCID: 0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID: 0000-0003-4637-0771). These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Low-density polyethylene PY - 2021 DO - https://doi.org/10.1116/6.0000907 VL - 39 IS - 2 SP - 027001 PB - American Vacuum Society AN - OPUS4-52380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Belsey, N. A. A1 - Cant, D. J. H. A1 - Minelli, C. A1 - Araujo, J. R. A1 - Bock, B. A1 - Brüner, P. A1 - Castner, D. G. A1 - Ceccone, G. A1 - Counsell, J. D. P. A1 - Dietrich, Paul M. A1 - Engelhardt, M. H. A1 - Fearn, S. A1 - Galhardo, C. E. A1 - Kalbe, H. A1 - Kim, J. W. A1 - Lartundo-Rojas, L. A1 - Luftman, H. S. A1 - Nunney, T. S. A1 - Pseiner, J. A1 - Smith, E. F. A1 - Spampinato, V. A1 - Sturm, J. M. A1 - Thomas, A. G. A1 - Treacy, J. P. W. A1 - Veith, L. A1 - Wagstaffe, M. A1 - Wang, H. A1 - Wang, M. A1 - Wang, Y.-C. A1 - Werner, W. A1 - Yang, L. A1 - Shard, A. G. T1 - Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS N2 - We report the results of a Versailles Project on Advanced Materials and Standards (VAMAS) interlaboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage, or sample preparation resulted in a variability in thickness of 53%. The calculation method chosen by XPS participants contributed a variability of 67%. However, variability of 12% was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors since this contributed a variability of 33%. The results from the LEIS participants were more consistent, with variability of less than 10% in thickness, and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films, and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results. KW - VAMAS KW - Interlaboratory Study KW - Nanoparticle coating KW - XPS KW - LEIS KW - shell thicknss and chemistry PY - 2016 UR - http://pubs.acs.org/doi/pdf/10.1021/acs.jpcc.6b06713 DO - https://doi.org/10.1021/acs.jpcc.6b06713 IS - 120 SP - 24070 EP - 24079 PB - ACS Publications AN - OPUS4-38428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Faghani, A. A1 - Gholami, M. F. A1 - Trunk, M. A1 - Müller, J. A1 - Pachfule, P. A1 - Vogl, S. A1 - Donskyi, Ievgen A1 - Li, M. A1 - Nickl, Philip A1 - Shao, J. A1 - Huang, M. R. S. A1 - Unger, Wolfgang A1 - Arenal, R. A1 - Koch, C. T. A1 - Paulus, B. A1 - Rabe, J. P. A1 - Thomas, A. A1 - Haag, R. A1 - Adeli, M. T1 - Metal-Assisted and Solvent-Mediated Synthesis of Two-Dimensional Triazine Structures on Gram Scale N2 - Covalent triazine frameworks are an emerging material class that have shown promising performance for a range of applications. In this work, we report on a metal-assisted and solvent-mediated reaction between calcium carbide and cyanuric chloride, as cheap and commercially available precursors, to synthesize two-dimensional triazine structures (2DTSs). The reaction between the solvent, dimethylformamide, and cyanuric chloride was promoted by calcium carbide and resulted in dimethylamino-s-triazine intermediates, which in turn undergo nucleophilic substitutions. This reaction was directed into two dimensions by calcium ions derived from calcium carbide and induced the formation of 2DTSs. The role of calcium ions to direct the two-dimensionality of the final structure was simulated using DFT and further proven by synthesizing molecular intermediates. The water content of the reaction medium was found to be a crucial factor that affected the structure of the products dramatically. While 2DTSs were obtained under anhydrous conditions, a mixture of graphitic material/2DTSs or only graphitic material (GM) was obtained in aqueous solutions. Due to the straightforward and gram-scale synthesis of 2DTSs, as well as their photothermal and photodynamic properties, they are promising materials for a wide range of future applications, including bacteria and virus incapacitation. KW - XPS KW - Triazine KW - 2D PY - 2020 DO - https://doi.org/10.1021/jacs.0c02399 VL - 142 IS - 30 SP - 12976 EP - 12986 PB - ACS American Chemical Society AN - OPUS4-51203 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seah, M.P. A1 - Spencer, S.J. A1 - Bensebaa, F. A1 - Vickridge, I. A1 - Danzebrink, H. A1 - Krumrey, M. A1 - Gross, Thomas A1 - Österle, Werner A1 - Wendler, E. A1 - Rheinländer, B. A1 - Azuma, Y. A1 - Kojima, I. A1 - Suzuki, N. A1 - Suzuki, M. A1 - Tanuma, S. A1 - Moon, D.W. A1 - Lee, H.J. A1 - Cho, H.M. A1 - Chen, H.Y. A1 - Wee, A. T. S. A1 - Osipowicz, T. A1 - Pan, J.S. A1 - Jordaan, W.A. A1 - Hauert, R. A1 - Klotz, U. A1 - van der Marel, C. A1 - Verheijen, M. A1 - Tamminga, Y. A1 - Jeynes, C. A1 - Bailey, P. A1 - Biswas, S. A1 - Falke, U. A1 - Nguyen, N.V. A1 - Chandler-Horowitz, D. A1 - Ehrstein, J.R. A1 - Muller, D. A1 - Dura, J.A. T1 - Critical review of the current status of thickness measurements for ultrathin SiO2 on Si - Part V: Results of a CCQM pilot study N2 - Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters. The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy. KW - Calibration KW - Ellipsometry KW - GIXRR KW - Interlaboratory study KW - MEIS KW - Neutron reflectometry KW - NRA KW - RBS KW - Silicon dioxide KW - SIMS KW - XPS PY - 2004 DO - https://doi.org/10.1002/sia.1909 SN - 0142-2421 SN - 1096-9918 VL - 36 IS - 9 SP - 1269 EP - 1303 PB - Wiley CY - Chichester AN - OPUS4-5549 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Seah, M.P. A1 - Spencer, S.J. A1 - Bensebaa, F. A1 - Vickridge, I. A1 - Danzebrink, H. A1 - Krumrey, M. A1 - Gross, Thomas A1 - Österle, Werner A1 - Wendler, E. A1 - Rheinländer, B. A1 - Azuma, Y. A1 - Kojima, I. A1 - Suzuki, N. A1 - Suzuki, M. A1 - Tanuma, S. A1 - Moon, D.W. A1 - Lee, H.J. A1 - Cho, H.M. A1 - Chen, H.Y. A1 - Wee, A. T. S. A1 - Osipowicz, T. A1 - Pan, J.S. A1 - Jordaan, W.A. A1 - Hauert, R. A1 - Klotz, U. A1 - van der Marel, C. A1 - Verheijen, M. A1 - Tamminga, Y. A1 - Jeynes, C. A1 - Bailey, P. A1 - Biswas, S. A1 - Falke, U. A1 - Nguyen, N.V. A1 - Chandler-Horowitz, D. A1 - Ehrstein, J.R. A1 - Muller, D. A1 - Dura, J.A. T1 - Ultra-thin SiO2 on Si, Part V: Results of a CCQM Pilot Study of Thickness Measurements KW - SiO2 KW - Thin films KW - Thickness KW - XPS KW - Ellipsometry KW - TEM PY - 2003 SN - 1473-2734 SP - 57 pages AN - OPUS4-4118 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gradt, Thomas A1 - Schneider, Thomas A1 - Lingertat, J. A1 - Hathiramani, D. A1 - Junghanns, P. A1 - Aßmus, Kristin A1 - Schauer, F. T1 - Cryogenic vacuum tests of scaled down narrow support elements for the W7-X coil system KW - Wendelstein 7-X KW - Magnet system KW - Narrow support elements KW - Friction KW - MoS2 PY - 2009 DO - https://doi.org/10.1016/j.fusengdes.2008.11.075 SN - 0920-3796 VL - 84 IS - 2-6 SP - 840 EP - 843 PB - North-Holland Publ. Co. CY - Amsterdam AN - OPUS4-19662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lingertat, J. A1 - Gradt, Thomas A1 - Hathiramani, D. A1 - Junghanns, P. A1 - Laux, M. A1 - Meine, Kerstin A1 - Schauer, F. A1 - Schneider, Thomas T1 - Tribological performance of MoS2 coatings in liquid helium and at high loads N2 - The main part of a narrow support element (NSE) of the W7-X superconducting coil system is an aluminium bronze pad, PVD coated on its spherical surface with MoS2, which slides against the flat surface of the stainless steel coil housing, coated with MoS2 spray. The operational requirements of the NSEs are: vacuum of p < 10-6 mbar, temperature T ~4 K, maximum load P ~1500 kN, typical displacement ≤5 mm, smooth sliding and no stick-slip events. The paper describes test results obtained with a downscaled NSE at T = 4.2 and 77 K. During the test the NSEs were submerged in liquid helium and nitrogen, respectively. Whereas the LN2 test ran smoothly for up to ~15,000 cycles, the test in LHe showed stick-slip from the very first cycle. The stick-slip disappeared after ~50 cycles. Post mortem analysis of the tested parts revealed that in case of LHe the sprayed MoS2 film was removed during the first 30-100 cycles by blistering and flaking. The reason for the loss of adhesion at LHe temperature is not known, several possible causes are under discussion. Further experiments under vacuum and at T ~4 K are being prepared which are expected to help in clarifying the issue. KW - Stellarator KW - Wendelstein 7-X KW - Mechanical structure KW - Narrow support elements KW - MoS2 KW - Lubrication KW - T=4K PY - 2009 DO - https://doi.org/10.1016/j.fusengdes.2009.01.069 SN - 0920-3796 VL - 84 IS - 7-11 SP - 1192 EP - 1196 PB - North-Holland Publ. Co. CY - Amsterdam AN - OPUS4-19745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thomas, Hans-Martin A1 - Stadthaus, Meinhard A1 - Baugatz, J. A1 - König, W. A1 - Migoun, N. P. A1 - Prokhorenko, P. P. A1 - Gnusin, A. B. T1 - Reproducibility Problem for the Procedure of Type Testing of Liquid Penetrants N2 - Apparently that the type testing procedure should be conducted under the conditions ensuring reproducibility of its outcomes. We investigated various factors effecting upon the reproducibility. To obtain quantitative characteristics of indication’s visibility the image-processing hard-and software were used. It was established that there are two main groups of these factors. The first depends on the differences between various test panels, which are used for type testing. The second one concerns the reproducibility of some stages of penetrant testing procedure (excess penetrant removing and developer application). The recommendations to increase the reproducibility of type testing are developed and illustrated experimentally. The determination of penetrant system sensitivity as a part of type testing should be conducted ensuring reproducibility of the result. We investigated some factors effecting the reproducibility. To obtain quantitative characteristics of indication’s visibility, an image processing system was used [1]. We used 3 different sets of reference blocks (rb1, rb2, rb3) corresponding to type 1 of EN ISO 3452-3 [2]. Two fluorescent penetrants with different sensitivities and the same wet solvent developer were used. It was established that the reproducibility of type testing is influenced by mainly two principal factors. First there are the differences between reference blocks. Second one concerns the reproducibility of penetrant testing procedure, especially excess penetrant removal and developer application. According to EN ISO 3452-3 a reference block for determination of sensitivity level of fluorescent penetrants consists of a set of three nickel-chrome plated panels with 10, 20 and 30 µm plating thickness. Transverse cracks are made in each panel by stretching the panels in the longitudinal direction and width to depth ratio of the cracks should be approximately 1/20. Each panel presents a certain sensitivity level, which is characterised by the level of visibility of the indication. The highest level 3 corresponds to the panel with 10 µm thickness plating. Each panel is cut longitudinally (perpendicular to the crack) so that 2 sheets (panels A and B) with nearly the same cracks will be produced. These panels A and B of a reference block are used for relative evaluation, for example to compare sensitivities of two penetrants. It is considered that the application of the same penetrant to both panels with subsequent adequate development results in the same visibility of the indications on these panels. Quantitative correlations between the abilities of the reference blocks used for determining of the sensitivity were obtained in our investigations. We used the relations between the measured values of light-fluxes from the indications of similar comparing areas on two panels. These indications correspond to certain cracks’ parts of the same total length on both comparing areas. The relations of the steps between the panel are responsible for the definition of the sensitivity groups. From our investigations it follows that the steps of the different sets are different. Besides it was established that the indication‘s visibility for the same penetrant applied on different reference blocks might have a considerable difference depending on the penetrant sensitivity: the higher penetrant’ sensitivity, the smaller is such a difference between the steps 30/20 and 20/10. For example, for rb3 the relations 30/20 and 20/10 for lower sensitive penetrant (I1) reached factor 3 comparing with factor 2 for higher sensitive penetrant (I2). Some results of the comparison between the 3 sets (rb1, rb2, rb3) investigations are summarised in Table 1 with rb1 as a reference. T2 - 8th ECNDT CY - Barcelona, Spain DA - 2002-06-17 PY - 2002 UR - http://www.ndt.net/article/ecndt02/199/199.htm VL - 8 SP - 1(?) EP - 5(?) PB - European Federation for Non-Destructive Testing CY - Barcelona AN - OPUS4-1396 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eschlböck-Fuchs, S. A1 - Huber, N. A1 - Ahamer, C. M. A1 - Hechenberger, J. G. A1 - Kolmhofer, P. J. A1 - Heitz, J. A1 - Rössler, R. A1 - Demidov, Alexander A1 - Schmid, Thomas A1 - Gornushkin, Igor B. A1 - Panne, Ulrich A1 - Pedarnig, J. D. T1 - Application of laser-induced breakdown spectroscopy for the analysis of slags in industrial steel production N2 - Laser-induced breakdown spectroscopy (LIBS) is a fast and versatile technique for (semi) quantitative element analysis of solids, liquids, gases, and particulate matter. The LIBS method is used for optical sensing in various branches of industrial production. In the contribution we review some of our recent results on LIBS analysis of slags from secondary metallurgy in industrial steel making. Major oxides in steel slags are measured at-line and after homogenization using a calibration-free (CF) method. Two approaches for CF analysis based on the Boltzmann plot method and on the calculation of synthetic spectra are compared for the analysis of quaternary oxides. We also present the research in cooperation with our industrial partners in the process-analytical chemistry network PAC. T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Vienna, Austria DA - 30.11.2015 KW - Laser-induced breakdown spectroscopy (LIBS) KW - Process analytical technology KW - Steel slag PY - 2015 PB - Plandruck+ Gesellschaft m.b.H. CY - Wien AN - OPUS4-39005 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abou-Ras, D. A1 - Caballero, R. A1 - Fischer, C.-H. A1 - Kaufmann, C.A. A1 - Lauermann, I. A1 - Mainz, R. A1 - Mönig, H. A1 - Schöpke, A. A1 - Stephan, C. A1 - Streeck, C. A1 - Schorr, S. A1 - Eicke, A. A1 - Döbeli, M. A1 - Gade, B. A1 - Hinrichs, J. A1 - Nunney, T. A1 - Dijkstra, H. A1 - Hoffmann, V. A1 - Klemm, D. A1 - Efimova, V. A1 - Bergmaier, A. A1 - Dollinger, G. A1 - Wirth, Thomas A1 - Unger, Wolfgang A1 - Rockett, A.A. A1 - Perez-Rodriguez, A. A1 - Alvarez-Garcia, J. A1 - Izquierdo-Roca, V. A1 - Schmid, T. A1 - Choi, P.-P. A1 - Müller, M. A1 - Bertram, F. A1 - Christen, J. A1 - Khatri, H. A1 - Collins, R.W. A1 - Marsillac, S. A1 - Kötschau, I. T1 - Comprehensive comparison of various techniques for the analysis of elemental distributions in thin films N2 - The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits. KW - Elemental distributions KW - Comparison KW - Depth profiling KW - Chemical mapping KW - Thin films KW - Solar cells KW - Chalcopyrite-type KW - Cu(In,Ga)Se2 PY - 2011 DO - https://doi.org/10.1017/S1431927611000523 SN - 1431-9276 SN - 1435-8115 VL - 17 IS - 5 SP - 728 EP - 751 PB - Cambridge University Press CY - New York, NY AN - OPUS4-24506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Demidov, Alexandr A1 - Eschlböck-Fuchs, S. A1 - Kazakov, Alexander Ya. A1 - Gornushkin, Igor B. A1 - Kolmhofer, P. J. A1 - Pedarnig, J. D. A1 - Huber, N. A1 - Heitz, J. A1 - Schmid, Thomas A1 - Rössler, R. A1 - Panne, Ulrich T1 - Monte Carlo standardless approach for laser induced breakdown spectroscopy based on massive parallel graphic processing unit computing N2 - The improved Monte-Carlo (MC) method for standard-less analysis in laser induced breakdown spectroscopy (LIBS) is presented. Concentrations in MC LIBS are found by fitting model-generated synthetic spectra to experimental spectra. The current version of MC LIBS is based on the graphic processing unit (GPU) computation and reduces the analysis time down to several seconds per spectrum/sample. The previous version of MC LIBS which was based on the central processing unit (CPU) computation requested unacceptably long analysis times of 10's minutes per spectrum/sample. The reduction of the computational time is achieved through the massively parallel computing on the GPU which embeds thousands of co-processors. It is shown that the number of iterations on the GPU exceeds that on the CPU by a factor > 1000 for the 5-dimentional parameter space and yet requires > 10-fold shorter computational time. The improved GPU-MC LIBS outperforms the CPU-MS LIBS in terms of accuracy, precision, and analysis time. The performance is tested on LIBS-spectra obtained from pelletized powders of metal oxides consisting of CaO, Fe2O3, MgO, and TiO2 that simulated by-products of steel industry, steel slags. It is demonstrated that GPU-based MC LIBS is capable of rapid multi-element analysis with relative error between 1 and 10's percent that is sufficient for industrial applications (e.g. steel slag analysis). The results of the improved GPU-based MC LIBS are positively compared to that of the CPU-based MC LIBS as well as to the results of the standard calibration-free (CF) LIBS based on the Boltzmann plot method. KW - Monte Carlo simulation KW - Parallel computing KW - Calibration-free laser-induced breakdown spectroscopy KW - Post-breakdown laser induced plasma KW - Quaternary oxides PY - 2016 DO - https://doi.org/10.1016/j.sab.2016.09.016 VL - 125 SP - 97 EP - 102 PB - Elsevier B.V. AN - OPUS4-38489 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Füllenbach, L.C. A1 - Perez, J. P. H. A1 - Freeman, H.M. A1 - Thomas, A.N. A1 - Mayanna, S. A1 - Parker, J. E. A1 - Göttlicher, J. A1 - Steininger, R. A1 - Radnik, Jörg A1 - Benning, L.G. A1 - Oelkers, E.H. T1 - Nanoanalytical Identification of Siderite Dissolution-Coupled Pb Removal Mechanisms from Oxic and Anoxic Aqueous Solutions N2 - Lead(II) is a toxic pollutant often found in metalcontaminated soils and wastewaters. In acidic aqueous environments, Pb(II) is highly mobile. Chemical treatment strategies of such systems therefore often include neutralization agents and metal sorbents. Since metal solubility and the retention potential of sorbents depend on the redox state of the aqueous system, we tested the efficiency of the naturally occurring redox-sensitive ferrous iron carbonate mineral siderite to remove Pb(II) from acidic aqueous solutions in batch experiments under oxic and anoxic conditions over a total of 1008 h. Siderite dissolution led to an increase in reactive solution pH from 3 to 5.3 and 6.9, while 90 and 100% of the initial aqueous Pb(II) (0.48 × 10−3 mol kg−1) were removed from the oxic and anoxic systems, respectively. Scanning and transmission electron microscopy, combined with X-ray absorption and photoelectron spectroscopy, indicated that under oxic conditions, Pb(II) was consumed by cerussite precipitation and inner-sphere surface complexation to secondary goethite. Under anoxic conditions, Pb(II) was removed by the rapid precipitation of cerussite. This efficient siderite dissolution-coupled sequestration of Pb(II) into more stable solid phases demonstrates this potential method for contaminated water Treatment regardless of the redox environment. KW - Siderite KW - X-ray absorption spectroscopy KW - X-ray photoelectron spectroscopy KW - Wastewater treatment PY - 2020 DO - https://doi.org/10.1021/acsearthspacechem.0c00180 VL - 4 IS - 11 SP - 1966 EP - 1977 PB - ACS Publication AN - OPUS4-51961 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Boon-Brett, L. A1 - Bousek, J. A1 - Black, G. A1 - Moretto, P. A1 - Castello, P. A1 - Hübert, Thomas A1 - Banach, Ulrich T1 - Identifiying performance gaps in hydrogen safety sensor technology for automotive and stationary applications N2 - A market survey has been performed of commercially available hydrogen safety sensors, resulting in a total sample size of 53 sensors from 21 manufacturers. The technical specifications, as provided by the manufacturer, have been collated and are displayed herein as a function of sensor working principle. These specifications comprise measuring range, response and recovery times, ambient temperature, pressure and relative humidity, power consumption and lifetime. These are then compared against known performance targets for both automotive and stationary applications in order to establish in how far current technology satisfies current requirements of sensor end users. Gaps in the performance of hydrogen sensing technologies are thus identified and areas recommended for future research and development. KW - Hydrogen sensor KW - Hydrogen detection KW - Safety KW - Sensor performance testing KW - Performance specifications KW - Performance targets PY - 2010 DO - https://doi.org/10.1016/j.ijhydene.2009.10.064 SN - 0360-3199 VL - 35 IS - 1 SP - 373 EP - 384 PB - Elsevier CY - Oxford AN - OPUS4-22893 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Almagro, J.-F. A1 - Busch, P. A1 - Gohil, D. D. A1 - Heikinheimo, E. A1 - Karduck, P. A1 - Richter, S. A1 - Sloof, W. G. A1 - Thiot, J.-F. A1 - Wirth, Thomas T1 - Electron-Probe MICROanalysis of LighT Elements - Measurement Methods and Certified Reference Materials (MICROLITE) PY - 2002 IS - 65 SP - 1 EP - 156 PB - National Physical Laboratory CY - Teddington, Middlesex AN - OPUS4-1911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Das, P. A1 - Chakraborty, Gouri A1 - Roeser, J. A1 - Vogl, S. A1 - Rabeah, J. A1 - Thomas, A. T1 - Integrating Bifunctionality and Chemical Stability in Covalent Organic Frameworks via One-Pot Multicomponent Reactions for Solar-Driven H2O2 Production N2 - Multicomponent reactions (MCRs) can be used to introduce different functionalities into highly stable covalent organic frameworks (COFs). In this work, the irreversible three-component Doebner reaction is utilized to synthesize four chemically stable quinoline-4-carboxylic acid DMCR-COFs (DMCR-1−3 and DMCR-1NH) equipped with an acid−base bifunctionality. These DMCR-COFs show superior photocatalytic H2O2 evolution (one of the most important industrial oxidants) compared to the imine COF analogue (Imine-1). This is achieved with sacrificial oxidants but also in pure water and under an oxygen or air atmosphere. Furthermore, the DMCR-COFs show high photostability, durability, and recyclability. MCR-COFs thus provide a viable materials’ platform for solar to chemical energy conversion. KW - Reactions KW - Bifunctionality KW - Postsynthetic modification KW - Multicomponent PY - 2022 DO - https://doi.org/10.1021/jacs.2c11454 SN - 0002-7863 VL - 145 IS - 5 SP - 2975 EP - 2984 PB - ACS Publications AN - OPUS4-56922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Christensen, J. B. A1 - Jørgensen, A. A. A1 - Vandborg, M. H. A1 - Thomas, P. J. A1 - Lu, Xin A1 - Failleau, G. A1 - Eisermann, R. A1 - Grüner-Nielsen, L. A1 - Balslev-Harder, D. A1 - Lassen, M. A1 - Krenek, S. T1 - Fiber-artefact methodology and calibration framework for Brillouin-based fiber sensing N2 - We propose, and demonstrate, the use of a fiber-optical measurement artefact as a metrological tool for traceable distance calibration of distributed optical fiber sensors. The constructed fiber artefact consists of a lead-in fiber coupled to a fiber loop using a 3-dB coupler and is used to calibrate both a home-build Brillouin-OTDR setup and a custom version of a commercial Brillouin-OTDR interrogator build for distributed temperature sensing. For both interrogators, we demonstrate distance calibrations with 1-meter uncertainty (k=1) in the offset length and 0.1 % (1 m/km) uncertainty (k = 1) in the distance scale factor. In addition, it is shown that the fiber artefact can be used to assess undesired distance-dependent measurement biases. KW - Distributed temperature sensing KW - Metrology KW - Distributed optical fiber sensing KW - Brillouin optical time-domain reflectrometry PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-618853 DO - https://doi.org/10.1364/OE.544659 SN - 1094-4087 VL - 32 IS - 26 SP - 45483 EP - 45493 PB - Optica Publishing Group AN - OPUS4-61885 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Almagro, J.-F. A1 - Busch, P. A1 - Gohil, D. D. A1 - Saunders, S. R. J. A1 - Sloof, W. G. A1 - Thiot, J.-F. A1 - Schneider, H. A1 - Whitwood, M. A1 - Wirth, Thomas T1 - Electron-Probe MICROanalysis of LighT Elements - Measurement Methods and Certified Reference Materials (MICROLITE) PY - 2000 IS - 266 SP - 1 EP - 35 PB - National Physical Laboratory CY - Teddington, Middlesex AN - OPUS4-6843 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berthold, J. A1 - Vrana, J. A1 - Heckel, Thomas A1 - Kanzler, D. A1 - Jatzlau, P. A1 - Große, C. T1 - Modellgestützte Bestimmung der Auffindwahrscheinlichkeit (POD) von Reflektoren bei der Ultraschallprüfung großer Schmiedeteile N2 - Bruchmechanische Untersuchungen werden zur Vorhersage der Lebensdauer und der Wartungszyklen benutzt. Dabei wird davon ausgegangen, dass auch Objekte ohne detektierte Anzeigen Materialfehler mit einer Reflektivität kleiner der Nachweisgrenze aufweisen können. Keine detektierte Anzeige bedeutet daher für Bauteilauslegung, dass sie eine konservative Annahme machen müssen: es wird angenommen, dass das Bauteil Materialfehler in Größe der Nachweisgrenze enthält. Dies macht die Nachweisgrenze zu dem die Lebensdauer limitierenden Faktor. Bei probabilistischen Methoden wird zusätzliches Wissen, wie Zuverlässigkeit und Fehlerauffindwahrscheinlichkeiten bei der zerstörungsfreien Prüfung mit in die Berechnung einbezogen, um zu konservative Annahmen zu vermeiden. Ziel ist es eine Model-Assisted-POD aufzubauen mit der die reale volumetrische Ultraschallprüfung großer Schmiedeteile nachgebildet werden kann. Die resultierende POD soll im Weiteren in bruchmechanischen Betrachtungen Verwendung finden. In vorangegangenen Arbeiten [Preißel2015] wurde dazu der Einfluss des Prüfrasters nach der DGZfP-Richtlinie US 07:2014 auf die Fehlerauffindwahrscheinlichkeit (parametrisch) simulativ betrachtet und die Simulationstechnik experimentell validiert. In diesem Paper werden die Ergebnisse von Preißel überprüft und um eine Prüfraster-Summen-POD, die das Szenario der realen Bauteilprüfung beschreibt, erweitert. Zudem wird eine experimentell validierte, simulative, nicht-parametrische POD für schrägliegende Defekte aufgebaut. Schließlich werden erste Untersuchungen zur Defektmorphologie vorgestellt. Diese Arbeit ist im Rahmen eines Studenten-Stipendiums der DGZfP entstanden. T2 - DGZfP DACH Tagung 2019 CY - Friedrichshafen, Germany DA - 27.05.2019 KW - Schmiedeteile KW - POD KW - Ultraschall KW - Zerstörungsfreie Prüfung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-496796 UR - http://www.ndt.net/?id=24529 VL - 24 IS - 8 SP - 1 EP - 12 PB - NDT.net CY - Kirchwald AN - OPUS4-49679 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dumit, Verónica I. A1 - Furxhi, Irini A1 - Nymark, Penny A1 - Afantitis, Antreas A1 - Ammar, Ammar A1 - Amorim, Monica J. B. A1 - Antunes, Dalila A1 - Avramova, Svetlana A1 - Battistelli, Chiara L. A1 - Basei, Gianpietro A1 - Bossa, Cecilia A1 - Cimpan, Emil A1 - Cimpan, Mihaela Roxana A1 - Ciornii, Dmitri A1 - Costa, Anna A1 - Delpivo, Camilla A1 - Dusinska, Maria A1 - Fonseca, Ana Sofia A1 - Friedrichs, Steffi A1 - Hodoroaba, Vasile-Dan A1 - Hristozov, Danail A1 - Isigonis, Panagiotis A1 - Jeliazkova, Nina A1 - Kochev, Nikolay A1 - Kranjc, Eva A1 - Maier, Dieter A1 - Melagraki, Georgia A1 - Papadiamantis, Anastasios G. A1 - Puzyn, Tomasz A1 - Rauscher, Hubert A1 - Reilly, Katie A1 - Jiménez, Araceli Sánchez A1 - Scott‐Fordsmand, Janeck J. A1 - Shandilya, Neeraj A1 - Shin, Hyun Kil A1 - Tancheva, Gergana A1 - van Rijn, Jeaphianne P. M. A1 - Willighagen, Egon L. A1 - Wyrzykowska, Ewelina A1 - Bakker, Martine I. A1 - Drobne, Damjana A1 - Exner, Thomas E. A1 - Himly, Martin A1 - Lynch, Iseult T1 - Challenges and Future Directions in Assessing the Quality and Completeness of Advanced Materials Safety Data for Re‐Usability: A Position Paper From the Nanosafety Community N2 - Ensuring data quality, completeness, and interoperability is crucial for progressing safety research, Safe‐and‐Sustainable‐by‐Design approaches, and regulatory approval of nanoscale and advanced materials. While the FAIR (Findable, Accessible, Interoperable, and Re‐usable) principles aim to promote data re‐use, they do not address data quality, essential for data re‐use for advancing sustainable and safe innovation. Effective quality assurance procedures require (meta)data to conform to community‐agreed standards. Nanosafety data offer a key reference point for developing best practices in data management for advanced materials, as their large‐scale generation coincided with the emergence of dedicated data quality criteria and concepts such as FAIR data. This work highlights frameworks, methodologies, and tools that address the challenges associated with the multidisciplinary nature of nanomaterial safety data. Existing approaches to evaluating the reliability, relevance, and completeness of data are considered in light of their potential for integration into harmonized standards and adaptation to advance material requirements. The goal here is to emphasize the importance of automated tools to reduce manual labor in making (meta)data FAIR, enabling trusted data re‐use and fostering safer, more sustainable innovation of advanced materials. Awareness and prioritization of these challenges are critical for building robust data infrastructures. KW - Advanced materials KW - Safety data KW - Re-usability KW - Nanosafety KW - SSbD KW - FAIR KW - Standardisation PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652918 DO - https://doi.org/10.1002/adsu.202500567 SN - 2366-7486 SP - 1 EP - 18 PB - Wiley-VCH CY - Weinheim AN - OPUS4-65291 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - El Abbassi, Abdelouahad A1 - Krenzer, Julius A1 - Petrov, Eugene P. A1 - Biesen, Lukas A1 - Vasylyeva, Vera A1 - Merzenich, Sarah A1 - Resch-Genger, Ute A1 - Müller, Thomas J. J. T1 - Aroyl-S,N-ketene acetal-triarylamine bichromophores – intramolecular energy transfer and dual emission upon induced aggregation and encapsulation N2 - Aroyl-S,N-ketene acetal-based bichromophores are synthesized by a catalytic aryl amination and their photophysics are studied in the solid state, in ethanol–water mixtures inducing aggregation, and after encapsulation in polystyrene nanoparticles. The dye substitution pattern controls aggregation-induced emission and intramolecular energy transfer efficiency, resulting in single-band or dual fluorescence and a strong increase in fluorescence quantum yield upon particle encapsulation. KW - Fluorescence KW - Dye KW - Aggregation KW - Photophysics KW - Enhancement KW - White light emission KW - Energy transfer KW - Quantum yield PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656700 DO - https://doi.org/10.1039/d5ra09361a SN - 2046-2069 VL - 16 IS - 11 SP - 10255 EP - 10260 PB - Royal Society of Chemistry (RSC) AN - OPUS4-65670 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kim, K.J. A1 - Unger, Wolfgang A1 - Kim, J.W. A1 - Moon, D.W. A1 - Gross, Thomas A1 - Hodoroaba, Vasile-Dan A1 - Schmidt, Dieter A1 - Wirth, Thomas A1 - Jordaan, W. A1 - van Staden, M. A1 - Prins, S. A1 - Zhang, L. A1 - Fujimoto, T. A1 - Song, X.P. A1 - Wang, H. T1 - Inter-laboratory comparison: quantitative surface analysis of thin Fe-Ni alloy films N2 - An international interlaboratory comparison of the measurement capabilities of four National Metrology Institutes (NMIs) and one Designated Institute (DI) in the determination of the chemical composition of thin Fe-Ni alloy films was conducted via a key comparison (K-67) of the Surface Analysis Working Group of the Consultative Committee for Amount of Substance. This comparison was made using XPS (four laboratories) and AES (one laboratory) measurements. The uncertainty budget of the measured chemical composition of a thin alloy film was dominated by the uncertainty of the certified composition of a reference specimen which had been determined by inductively coupled plasma mass spectrometry using the isotope dilution method. Pilot study P-98 showed that the quantification using relative sensitivity factors (RSFs) of Fe and Ni derived from an alloy reference sample results in much more accurate result in comparison to an approach using RSFs derived from pure Fe and Ni films. The individual expanded uncertainties of the participants in the K-67 comparison were found to be between 2.88 and 3.40 atomic %. The uncertainty of the key comparison reference value (KCRV) calculated from individual standard deviations and a coverage factor (k) of 2 was 1.23 atomic %. KW - Quantification KW - Fe-Ni alloy KW - Uncertainty KW - Key comparison KW - Traceability PY - 2012 DO - https://doi.org/10.1002/sia.3795 SN - 0142-2421 SN - 1096-9918 VL - 44 IS - 2 SP - 192 EP - 199 PB - Wiley CY - Chichester AN - OPUS4-24505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -