TY - CHAP A1 - Ballio, F. A1 - Chatzi, E. A1 - Cigada, A. A1 - Darò, P. A1 - Elfgren, L. A1 - Gentile, C. A1 - Górski, M. A1 - Küttenbaum, Stefan A1 - Limongelli, M. P. A1 - Mancini, G. A1 - Oliveira, S. A1 - Rasol, M. A1 - Schmidt, F. A1 - Shan, J. A1 - Sousa, H. A1 - Torrent, R. A1 - Ueda, T. A1 - Verstrynge, E. T1 - Chapter 6: Case studies N2 - This chapter contains a selection of case studies that show the implementation of the methods and tools that have been described in the previous chaprters of fib Bulletin 109 on actual large-scale structures. KW - Structural engineering KW - Structural Health Monitoring KW - Non-destructive testing KW - Static and dynamic reassessment KW - Existing structures PY - 2023 SN - 978-2-88394-172-4 DO - https://doi.org/10.35789/fib.BULL.0109.Ch06 SN - 1562-3610 VL - fib Bulletin 109 SP - 104 EP - 126 PB - Fédération internationale du béton (fib) CY - Lausanne AN - OPUS4-59341 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Henning, L. M. A1 - Müller, J. T. A1 - Smales, Glen Jacob A1 - Pauw, Brian Richard A1 - Schmidt, J. A1 - Bekheet, M. F. A1 - Gurlo, A. A1 - Simon, U. T1 - Hierarchically porous and mechanically stable monoliths from ordered mesoporous silica and their water filtration potential N2 - Mechanically stable structures with interconnected hierarchical porosity combine the benefits of both small and large pores, such as high surface area, pore volume, and good mass transport capabilities. Hence, lightweight micro-/meso-/macroporous monoliths are prepared from ordered mesoporous silica COK-12 by means of spark plasma sintering (SPS, S-sintering) and compared to conventionally (C-) sintered monoliths. A multi-scale model is developed to fit the small angle X-ray scattering data and obtain information on the hexagonal lattice parameters, pore sizes from the macro to the micro range, as well as the dimensions of the silica population. For both sintering techniques, the overall mesoporosity, hexagonal pore ordering, and amorphous character are preserved. The monoliths' porosity (77–49%), mesopore size (6.2–5.2 nm), pore volume (0.50–0.22 g cm-3 ), and specific surface area (451–180 m2 g-1) decrease with increasing processing temperature and pressure. While the difference in porosity is enhanced, the structural parameters between the C-and S-sintered monoliths are largely converging at 900 C, except for the mesopore size and lattice parameter, whose dimensions are more extensively preserved in the S-sintered monoliths, however, coming along with larger deviations from the theoretical lattice. Their higher mechanical properties (biaxial strength up to 49 MPa, 724 MPa HV 9.807 N) at comparable porosities and ability to withstand ultrasonic treatment and dead-end filtration up to 7 bar allow S-sintered monoliths to reach a high permeance (2634 L m-2 h-1 bar-1), permeability (1.25 x 10^-14 m2), and ability to reduce the chemical oxygen demand by 90% during filtration of a surfactant-stabilized oil in water emulsion, while indicating reasonable resistance towards fouling. KW - SAXS KW - Hierarchically porous KW - Silica KW - Water filtration PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-555928 DO - https://doi.org/10.1039/D2NA00368F SN - 2516-0230 SP - 1 EP - 17 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-55592 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Baytekin, H.T. A1 - Wirth, Thomas A1 - Gross, Thomas A1 - Treu, Dieter A1 - Sahre, Mario A1 - Theisen, J. A1 - Schmidt, M. A1 - Unger, Wolfgang T1 - Determination of wettability of surface-modified hot-embossed polycarbonate wafers used in microfluidic device fabrication via XPS and ToF-SIMS N2 - The wettability of the surfaces inside the microchannels of a microfluidic device is an important property considering a liquid flows through them. Contact angle measurements usually applied to test the wettability of surfaces cannot be used for an analysis of microchannel walls within microfluidic devices. A workaround is the use of surface analytical methods, which are able to reach points of interest in microchannels and may provide information on the surface chemistry established there. In calibrating these methods by using flat polymer wafers, where the contact angle can be measured as usual, data measured in real microchannels can be evaluated in terms of wetting properties. Reference wafers of bisphenol-A polycarbonate, a polymeric material that is often used in fluidic microdevice fabrication, were treated under different oxygen plasma conditions. The modified surfaces were characterized by using XPS, time of flight (ToF)-SIMS and atomic force microscope (AFM). Surface chemistry and surface topography have been correlated with contact angle measurements. In addition, effects of ageing or rinsing after plasma treatment have also been investigated. KW - Oxygen plasma KW - Polycarbonate KW - XPS KW - ToF-SIMS KW - Principal component analysis PY - 2008 DO - https://doi.org/10.1002/sia.2724 SN - 0142-2421 SN - 1096-9918 VL - 40 IS - 3-4 SP - 358 EP - 363 PB - Wiley CY - Chichester AN - OPUS4-17340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Dirk A1 - T., Heidermann T1 - Ergebnisse der experimentellen Untersuchungen zur Visualisierung der Wirksamkeit von Deflagrationsrohrsicherungen in einer PVC-U Rohrleitung N2 - Deflagrationsrohrsicherungen sind Sicherheitseinrichtungen, die den Durchfluss von brennbaren Gasen und Dämpfen brennbarer Flüssigkeiten ermöglichen, den Flammendurchschlag und eine weitere Explosionsausbreitung nach der Zündung von explosionsfähigen Gas-/Dampf-Luftgemischen jedoch verhindern sollen. Die Einbaubedingungen sind dabei von besonderer Bedeutung für die Wirksamkeit der Deflagrationsrohrsicherungen. Oft lassen sich aus betrieblichen bzw. verfahrenstechnischen Gründen entsprechende Einbaubedingungen nur schwer oder nicht realisieren. So können beispielsweise Rohrleitungsverzweigungen zusätzliche Turbulenzen induzieren und dadurch zu erhöhten Flammenausbreitungsgeschwindigkeiten und Explosionsdrücken und ggf. zum Versagen der Deflagrationsrohrsicherung führen. Neben den „klassischen“ Untersuchungsmethoden dieser Belastungssituationen von Deflagrationsrohrsicherungen, wie die Erfassung des Explosionsdruckes und der Flammenausbreitungsgeschwindigkeiten, werden in diesem Beitrag die Ergebnisse der visuellen Beobachtungen des Reaktionsverlaufes sowie die Belastungen der Flammendurchschlagsicherung bei unterschiedlichen Einbaubedingungen in den Vordergrund gestellt. Gegenübergestellt wird die Belastungssituation der Flammensperre in einer geraden und einer verzweigten Rohrleitung. Verwendet wurde dafür eine speziell gefertigte Deflagrationsrohrsicherung, die eine Beobachtung des Reaktionsverlaufs im Bereich der spiralförmig gewickelten Metallbändern erlaubt. Zusätzlich wurde im geschützten Bereich in der Rohrleitung eine Kamera installiert, die die Belastungssituation bei den einzelnen Versuchen dokumentierte. Die Ergebnisse bestätigen sehr eindrucksvoll, dass die Belastungssituation der Deflagrationsrohrsicherung sich in Abhängigkeit von der Konfiguration der Rohrleitung entscheidend ändert T2 - 15. BAM/PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Brunswick, Germany DA - 21.05.2019 KW - Flammendurchschlagsicherungen KW - Rohrleitungen KW - Deflagrationen PY - 2019 DO - https://doi.org/10.7795/210.20190521A VL - 15. SP - 1 EP - 10 PB - PTB CY - Braunschweig AN - OPUS4-48084 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -