TY - RPRT A1 - Ballach, F. A1 - Bartscher, M. A1 - Bellon, Carsten A1 - Borges de Oliveira, F. A1 - Braun, M. A1 - Dennerlein, F. A1 - Flessner, M. A1 - Fuchs, P. A1 - Günnewig, O. A1 - Hausotte, T. A1 - Hess, J. A1 - Kasperl, S. A1 - Kirschbaum, K. A1 - Li, K. A1 - Maass, N. A1 - Mayer, T. A1 - Orth, Anthony A1 - Reuter, T. A1 - Suppes, A. A1 - von Schmid, M. A1 - Weiß, D. T1 - Realistische Simulation realer Röntgencomputertomografie-Systeme mit basisqualifizierter Simulationssoftware – CTSimU2 BT - Abschlussbericht N2 - Das Förderprojekt CTSimU2 baute auf den Ergebnissen des Projektes CTSimU auf. Dieses Vorprojekt erarbeitete ein (Basis-)Qualifizierungsframework für Simulationssoftwares zur Anwendung bei der Röntgen-CT für dimensionelle Messungen. Dabei stand die ausreichende physikalische Korrektheit der Durchstrahlungssimulation im Vordergrund. Für die realitätsnahe Simulation einer CT-Anlage in einer Simulationssoftware (Digitales Modell) ist jedoch nicht nur die Korrektheit der Simulationssoftware selbst, sondern auch die Güte der Parametrisierung des realen CT-Systems in der Simulationssoftware entscheidend – dies stellte den Ausgangspunkt dar. Die Parametrisierung eines CT-Systems in einer Simulationssoftware lässt sich in vier Schritte unterteilen: nach der Datenaufnahme am realen CT-System folgt die Auswertung der aufgenommenen Daten für die Generierung allgemeiner Parameterangaben. Als letztes folgte die Übertragung der Parameter in die spezifischen Simulationssoftwares und die Validierung der resultierenden Simulationsparameter. Die Methodik der Datenaufnahme am CT und die Auswertung der Daten wurde in einem Werkzeugkasten allgemein beschrieben. Der dritte Schritt, die Umsetzung der Parameter, war softwarespezifisch und wurde beispielhaft mit den vorhandenen Simulationssoftwares durchgeführt. Die Validierung der Parameter war standardisierbar und konnte durch den entwickelten Test geleistet werden, auf dessen Basis die ausreichend korrekte Simulation einer realen Anlage beurteilt werden konnte. Endresultat des Projektes war ein Richtlinienentwurf (z. B. VDI/VDE 2630) zu diesem Test, der einen informativen Annex zum Stand der Technik bezüglich der Möglichkeiten zur Parameterbestimmung enthält. Mit einer Simulationssoftware, die die Basisqualifizierung aus CTSimU bestanden hat und einen Parameterdatensatz für ein reales CT-System enthält, der den Test aus CTSimU2 bestanden hat, können realistische Simulationen dieses CT-Systems möglich sein. KW - Computertomografie KW - Simulation KW - Dimensionelles Messen PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-641719 DO - https://doi.org/10.34657/21602 N1 - Dieses Projekt wurde durch die Förderrichtlinie WIPANO gefördert und durch das Bundesministerium für Wirtschaft und Klimaschutz (2022 -2025) finanziert. Der Projektträger Jülich verwaltet die Projekte der Förderrichtlinie WIPANO. SP - 1 EP - 22 PB - TIB Technische Informationsbibliothek CY - Hannover AN - OPUS4-64171 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Angst, U. A1 - Brem, M. A1 - Dauberschmidt, C. A1 - Ebell, Gino A1 - Eichler, T. A1 - Hariri, K. A1 - Harnisch, J. A1 - Keßler, S. A1 - Kosalla, M. A1 - Mayer, T. F. A1 - Mietz, Jürgen A1 - Pruckner, F. A1 - Sodeikat, C. T1 - Merkblatt B 12 Korrosionsmonitoring bei Stahl- und Spannbetonbauwerken N2 - Das Merkblatt B12 enthält alle gängigen und etablierten Monitoringverfahren für das Korrosionsmonitoring an Stahlbetonbauwerken. KW - Korrosion KW - Monitoring PY - 2018 SN - 978-3-940283-93-1 SP - 1 EP - 58 PB - DGZfP CY - Berlin AN - OPUS4-45235 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ebell, Gino A1 - Achenbach, R. A1 - Angst, U. A1 - Brem, M. A1 - Dauberschmidt, C. A1 - Eichler, T. A1 - Hariri, K. A1 - Harnisch, J. A1 - Keßler, S. A1 - Mayer, T.F. A1 - Mietz, Jürgen A1 - Pruckner, F. T1 - Elektrochmische Potentialmessung zur Detektion von Bewehrungsstahlkorrosion N2 - Die Potentialmessung kann zum Auffinden korrosionsaktiver Bereiche neben Stahlbetonbauwerken auch bei Spannbetonbauwerken angewandt werden, die mit Spannstählen im direkten Verbund hergestellt werden. Bei Vorspannsystemen mit metallischen Hüllrohren im nachträglichen Verbund ist eine Aussage über den Korrosionszustand des Hüllrohrs, nicht aber des Spannstahls möglich. Messungen an Spannbetonbauteilen erfordern grundsätzlich die besonderen Kenntnisse eines Spezialisten. KW - Korrosion KW - Potentialfeldmessung KW - Corrosion KW - Concrete PY - 2021 SN - 978-3-947971-16-9 VL - Merkblatt B 03 SP - 1 EP - 22 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-53091 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ebell, Gino A1 - Achenbach, R. A1 - Angst, U. A1 - Dauberschmidt, C. A1 - Eichler, T. A1 - Hariri, K. A1 - Harnisch, J. A1 - Keßler, S. A1 - Kosalla, M. A1 - Mayer, T.F. A1 - Mietz, Jürgen A1 - Pruckner, F. A1 - Sodeikat, C. T1 - Specification B 12 - Corrosion monitoring in reinforced and prestressed concrete structures N2 - This specification describes how corrosion monitoring is used to check the condition of reinforced and prestressed concrete members. In this specification, the term "corrosion monitoring" covers all methods in which it is possible to continuously track corrosion-relevant variables in the area of stationary, built-in sensors. This specification does not cover other possible methods, such as potential field measurements, involving the use of mobile, portable sensors that are placed temporarily on the membersurface to take measurements. KW - Korrosion KW - Corrosion KW - Monitoring PY - 2021 SN - 978-3-947971-14-5 SP - 1 EP - 55 PB - DGZfP CY - Berlin AN - OPUS4-53092 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mayer, T. F. A1 - Dauberschmidt, C. A1 - Bruns, M. A1 - Eichler, T. A1 - Wiens, U. A1 - Mietz, Jürgen A1 - Gehlen, C. A1 - Ebell, Gino A1 - Gerhard, G. A1 - Osterminski, K. T1 - Das Instandsetzungsprinzip W-Cl N2 - Während das Instandsetzungsprinzip W bei carbonatisierungsinduzierter Korrosion seit vielen Jahren als Standardverfahren etabliert ist, wird seine Anwendbarkeit bei chloridinduzierter Korrosion (W-Cl) in der Fachwelt bis heute kontrovers diskutiert. Zwar ergeben sich aus seiner Anwendung gegenüber anderen Instandsetzungsverfahren auf den ersten Blick u. U. deutliche wirtschaftliche Vorteile, allerdings besteht bei diesem Verfahren ein deutlich höheres Risiko, dass das Instandsetzungsziel nicht erreicht wird. Im vorliegenden Beitrag werden die technischen Grundlagen des Instandsetzungsprinzips W-Cl sowie der aktuelle Kenntnisstand - sowohl für den gerissenen als auch für den ungerissenen Beton - dargestellt und baurechtliche Konsequenzen, die sich aus dem erhöhten Ausführungsrisiko ergeben, diskutiert. Korrosionsmonitoring als Element zum Nachweis des Instandsetzungserfolgs bei Anwendung des Prinzips W-Cl wird vorgestellt. Anhand von Anwendungsbeispielen werden sowohl die Risiken, die mit dem Verfahren verbunden sind, als auch das Potenzial bei erfolgreicher Anwendung veranschaulicht. KW - Korrosion KW - Instandsetzung KW - W-Cl KW - Risse PY - 2020 DO - https://doi.org/10.1002/bate.201900083 SN - 0932-8351 VL - 97 IS - 1 SP - 2 EP - 10 PB - Ernst & Sohn CY - Berlin AN - OPUS4-50246 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - C. Pardo Pérez, L. A1 - Arndt, A. A1 - Stojkovikj, S. A1 - Y. Ahmet, I. A1 - T. Arens,, J. A1 - Dattila, F. A1 - Wendt, R. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Davies, V. A1 - Höflich, K. A1 - Köhnen, E. A1 - Tockhorn, P. A1 - Golnak, R. A1 - Xiao, J. A1 - Schuck, G. A1 - Wollgarten, M. A1 - López, N. A1 - T. Mayer, M. T1 - Determining Structure-Activity Relationships in Oxide Derived CuSn Catalysts During CO2 Electroreduction Using X-Ray Spectroscopy N2 - The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts. KW - Electrochemical CO2 conversion KW - Cu catalysts KW - X-ray absorption spectroscopy PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547116 DO - https://doi.org/10.1002/aenm.202103328 SN - 1614-6832 VL - 12 IS - 5 SP - 2103328 PB - Wiley-VCH GmbH AN - OPUS4-54711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ebell, Gino A1 - Mayer, T. F. A1 - Harnisch, J. A1 - Dauberschmidt, Ch. T1 - Corrosion monitoring of reinforced concrete structures:The DGZfP specification B12 Collaboration N2 - Corrosion monitoring of reinforced or prestressed concrete structures has becomeincreasingly important in recent years. Areas of application include componentsthat are no longer accessible after completion or where potential fieldmeasurements cannot be carried out due to existing coatings. Corrosion monitoringcan also be used to monitor the progress of corrosion in corroding systems, e.g. to prove the success of repair measures according to repair principle 8 in accordancewith EN 1504‐9 or repair method 8.3 in accordance with the DIBt repair guideline.It also could be used to prove the functionality of cathodic corrosion protectionsystems in accordance with ISO 12696. Despite the increasing importance ofcorrosion monitoring, no guidelines orrecommendations existed until 2018. Thisgap was closed by the English version of specification B12,“Corrosion Monitoringof Reinforced and Prestressed Concrete Structures,”of the German Society for Non‐Destructive Testing, which was published in 2021. This article introducesspecification B12 by explaining the basicmeasurement principles and illustratingthe potential of corrosion monitoring in new and existing buildings. KW - Corrosion KW - Monitoring PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580982 DO - https://doi.org/10.1002/maco.202313934 SN - 0947-5117 SP - 1 EP - 9 PB - Wiley VHC-Verlag AN - OPUS4-58098 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mayer, T. F. A1 - Harnisch, J. A1 - Ebell, Gino A1 - Dauberschmidt, C. T1 - Korrosionsmonitoring von Stahlbetonbauwerken - Das DGZfP-Merkblatt B12 T1 - Corrosion monitoring of reinforced concrete structures: The DGZfP leaflet B12 N2 - Korrosionsmonitoring von Stahl- oder Spannbetonbauwerken hat in den vergangenen Jahren als Ergänzung zur herkömmlichen Bauwerksuntersuchung deutlich an Relevanz gewonnen. Einsatzgebiete sind z. B. Bauteile, die nach Fertigstellung nicht mehr zugänglich sind oder an denen aufgrund vorhandener Beschichtungen keine Potentialfeldmessungen durchgeführt werden können. Weiterhin kann Korrosionsmonitoring auch für die Überwachung des Korrosionsfortschritts an korrodierenden Systemen z. B. zum Nachweis des Instandsetzungserfolgs bei Anwendung des Prinzips W-Cl gemäß Instandsetzungsrichtlinie des DAfStb oder zum Funktionsnachweis bei KKS-Installationen nach DIN EN ISO 12696 eingesetzt werden. Trotz zunehmender Bedeutung Existieren für das Korrosionsmonitoring bis dato keine Richtlinien oder Handlungsempfehlungen. Diese Lücke soll das Merkblatt B12 „Korrosionsmonitoring von Stahl- und Spannbetonbauwerken“ der Deutschen Gesellschaft für zerstörungsfreie Prüfung DGZfP füllen, das im Frühjahr 2018 veröffentlicht wurde. In diesem Beitrag werden das Merkblatt B12 vorgestellt, die grundlegenden Messprinzipien erläutert und anhand von Anwendungsbeispielen das Potenzial von Korrosionsmonitoring bei Neubau- und Bestandsobjekten illustriert. KW - Korrosion KW - Monitoring PY - 2018 DO - https://doi.org/10.1002/best.201800026 SN - 1437-1006 SN - 0005-9900 VL - 113 IS - 9 SP - 632 EP - 639 PB - Ernst&Sohn CY - Berlin AN - OPUS4-45420 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ebell, Gino A1 - Mayer, T. F. T1 - Korrosions- und Verbundverhalten bei beschichteten Fugenblechen N2 - Wechselwirkung von feuerverzinkten Fugenblechen und Beton bei Einsatz in WU-Bauwerken. Mögliche Wasserstoffentwicklung an feuerverzinkten Fugenblechen durch Einwirkung hochalkalischer Medien wie Beton kann durch ausreichend großflächigen, kathodisch wirksamen, Betonstahl unterbunden werden. KW - Korrosion KW - Feuerverzinkter Stahl KW - Korrosionsschutz PY - 2023 SP - 1 EP - 6 CY - online DBV AN - OPUS4-57488 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Varga, E. A1 - Glauner, T. A1 - Köppen, Robert A1 - Mayer, K. A1 - Sulyok, M. A1 - Schuhmacher, R. A1 - Krska, R. A1 - Berthiller, F. T1 - Stable isotope dilution assay for the accurate determination of mycotoxins in maize by UHPLC-MS/MS N2 - A fast, easy-to-handle and cost-effective analytical method for 11 mycotoxins currently regulated in maize and other cereal-based food products in Europe was developed and validated for maize. The method is based on two extraction steps using different acidified acetonitrile–water mixtures. Separation is achieved using ultrahigh-performance liquid chromatography (UHPLC) by a linear water–methanol gradient. After electrospray ionisation, tandem mass spectrometric detection is performed in dynamic multiple reaction monitoring mode. Since accurate mass spectrometric quantification is hampered by matrix effects, uniformly [13C]-labelled mycotoxins for each of the 11 compounds were added to the sample extracts prior to UHPLC-MS/MS analysis. Method performance parameters were obtained by spiking blank maize samples with mycotoxins before as well as after extraction on six levels in triplicates. The twofold extraction led to total recoveries of the extraction steps between 97% and 111% for all target analytes, including fumonisins. The [13C]-labelled internal standards efficiently compensated all matrix effects in electrospray ionisation, leading to apparent recoveries between 88% and 105% with reasonable additional costs. The relative standard deviations of the whole method were between 4% and 11% for all analytes. The trueness of the method was verified by the measurement of several maize test materials with well-characterized concentrations. In conclusion, the developed method is capable of determining all regulated mycotoxins in maize and presuming similar matrix effects and extraction recovery also in other cerealbased foods. KW - Mycotoxins KW - Stable isotope dilution assay KW - Multi-target analysis KW - Ultrahigh-performance liquid chromatography KW - Tandem mass spectrometry KW - Maize PY - 2012 DO - https://doi.org/10.1007/s00216-012-5757-5 SN - 1618-2642 SN - 1618-2650 VL - 402 IS - 9 SP - 2675 EP - 2686 PB - Springer CY - Berlin AN - OPUS4-25640 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -