TY - CONF A1 - Schälike, Stefan T1 - Massenabbrandraten organischer Peroxide und von Kohlewasserstoffen unter besonderer Berücksichtigung multipler Feuer T2 - 13. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 2013-06-18 PY - 2013 AN - OPUS4-28714 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan T1 - Limiting Distance for Flame Merging of Multiple n-Heptane and Di-tert-Butyl Peroxide Pool Fires T2 - 11th International Conference on Chemical & Process Engineering (ICheaP-11) CY - Milan, Italy DA - 2013-06-02 PY - 2013 AN - OPUS4-28715 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan T1 - Validated CFD Simulation of Flame Temperatures of a Multiple N-heptane Pool Fire T2 - 6th European Combustion Meeting (ECM2013) CY - Lund, Sweden DA - 2013-06-25 PY - 2013 AN - OPUS4-28755 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan T1 - Abschätzung des Gefahrenpotentials wechselwirkender Brände in verfahrenstechnischen Anlagen T2 - ProcessNet Arbeitsausschuss "Auswirkungen von Stoff- und Energiefreisetzungen" CY - Frankfurt am Main, Germany DA - 2013-05-29 PY - 2013 AN - OPUS4-28756 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vela-Wallenschus, Iris A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. T1 - Kritische thermische Abstände bei wechselwirkenden KW- und Peroxid-Poolfeuern N2 - In verfahrenstechnischen Anlagen kann es während des Umgangs, des Transports und der Lagerung durch Freisetzung und anschliesender Zündung von brennbaren Flüssigkeiten zu Lachen-, Pool- oder Tankfeuern kommen. Die sich ausbildenden Feuer konnen große Schäden an benachbarten verfahrenstechnischen Anlagen und Personen verursachen. Im Unterschied zu Einzelfeuern sind multiple Pool- und Tankfeuer aufgrund ihrer Wechselwirkungseffekte sicherheitstechnisch von besonderer Bedeutung. Mit Di-tert-butyl-peroxid (DTBP) und n-Heptan als Leitsubstanzen werden Labor- und Feldexperimente (d ≤ 1.5 m) mit wechselwirkenden Poolflammen (N ≤ 9) in einer Matrixanordnung bei relativen horizontalen Abständen D/d zwischen den Pools im Bereich 0.16 ≤ D/d ≤ 4 durchgeführt. Die Phänomene der Flammenverschmelzung (Flammenfusion) in Abhängigkeit vom Poolabstand D/d werden experimentell untersucht und modelliert. T2 - 11. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 07.11.2013 KW - Wechselwirkende Poolfeuer KW - KW-Poolfeuer KW - Peroxid-Poolfeuer KW - Sicherheitsabstände KW - Spezifische Ausstrahlung KW - Bestrahlungsstärke PY - 2013 SN - 978-3-86011-058-4 N1 - Geburtsname von Vela-Wallenschus, Iris: Vela, I. - Birth name of Vela-Wallenschus, Iris: Vela, I. IS - P-06 SP - 1 EP - 17 AN - OPUS4-29549 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan T1 - Kritische thermische Abstände wechselwirkender KW- und Peroxid-Poolfeuer T2 - 11. Fachtagung "Anlagen-, Arbeits- und Umweltsicherheit" CY - Köthen, Germany DA - 2013-11-07 PY - 2013 N1 - Geburtsname von Vela-Wallenschus, Iris: Vela, I. - Birth name of Vela-Wallenschus, Iris: Vela, I. AN - OPUS4-29499 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan A1 - Mishra, Kirti Bhushan A1 - Ziemann, Sylvia A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. ED - Beyer, M. ED - Stolz, T. T1 - Massenabbrandraten organischer Peroxide unter besonderer Berücksichtigung der thermischen Stabilität N2 - Die Flüssigkeitstemperatur Temperatur in der flüssigen Phase unmittelbar im Grenzbereich zur Gasphase während eines Abbrandes organischer Peroxide überschreitet die Onset-Temperatur der beginnenden exothermen Zersetzungsreaktion des Peroxids, so dass diese zu berücksichtigen ist. Für die Peroxide Di-tert-butyl-Peroxid (DTBP) und tert-butyl-peroxybenzoat (TBPB) muss daher bei der Berechnung des Wärmerückstromes ein zusätzlicher Term für die Zersetzung in der Flüssigkeit additiv ergänzt werden. Der Umsatz der Zersetzungsreaktion wird unter den Bedingungen eines CSTR modelliert und erfolgt auf Basis einer Reaktionskinetik 1. Ordnung. Es kann gezeigt werden, dass der Wärmestrom in einem DTBP-Poolfeuer ≈ 40 % und einem TBPB-Poolfeuer ≈ 100 % des Wärmerückstromes durch Wärmestrahlung entspricht. Durch Q-Punkt-d können die vergleichsweise hohen Massenabbrandraten und die relative Unabhängigkeit der Massenabbrandraten vom Pooldurchmesser erklärt werden. Über eine Energiebilanz wird ein Modell basierend auf physikalischen Parametern entwickelt, das die Massenabbrandraten großer Poolfeuer, in sehr guter Übereinstimmung mit den experimentellen Ergebnissen, vorhersagt. T2 - 13. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 18.06.2013 KW - Poolfeuer KW - Massenabbrandrate KW - Organische Peroxide KW - Thermische Stabilität KW - Onset-Temperatur PY - 2013 SN - 978-3-95606-062-5 DO - https://doi.org/10.7795/210.20130801E SN - 1868-5838 SP - 40 EP - 47 AN - OPUS4-29815 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schälike, Stefan A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. ED - Rademaeker, E. D. T1 - Flame heights of di-tert-butyl peroxide pool fires - experimental study and modelling N2 - The flame heights of di-tert-butyl peroxide (DTBP) pool fires with diameters between 0.03 m < d < 3 m are determined by means of visible images obtained by a VHS video recorder. The time-averaged Hav and maximum flame height Hmax were evaluated according to the intermittency criterion. For the relative time-averaged flame heights values in a range of 3.1 < Hav/d < 14.8 are obtained while the relative maximum flame heights are in a range of 3.5 < Hmax/d < 17.6. The experimental measurements were used to establish a new Froude number correlation. T2 - CISAP5 - 5th International Conference on Safety and Environment in Process and Power Industry CY - Milan, Italy DA - 03.06.2012 KW - Pool fire KW - Di-tert-butyl peroxide KW - Flame height KW - Froude number correlation PY - 2012 SN - 978-88-95608-17-4 DO - https://doi.org/10.3303/CET1226061 SN - 1974-9791 N1 - Serientitel: Chemical engineering transactions – Series title: Chemical engineering transactions IS - 26 SP - 363 EP - 368 PB - Assoziatione Italiana di Ingegneria Chimica CY - Milano AN - OPUS4-26012 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Schönbucher, A. A1 - Schälike, Stefan T1 - Pool fires and spill fires N2 - Risk is the possibility of suffering damage. In engineering it may be quantified and is assessed as a combination of the expected frequency of an undesired event, e.g., in case of process plants a fire, an explosion, or a toxic release, and the damage associated with this event. Every possibility to suffer damage is a risk if it is uncertain whether it will become reality. Damage and uncertainty therefore are the two elements which determine a risk. If the Magnitude of damage and the uncertainty of its occurrence can be quantified, then a number may be assigned to the corresponding risk, the risk number. Frequently, this number refers to a which is based on a Gaussian model, Guideline part 2 with its physical modeling backbone will probably remain the Standard German Screening model for a couple of years to come. KW - Pool fires KW - Spill fires KW - Soot KW - Heat transfer KW - Modeling PY - 2012 SN - 978-3527306732 DO - https://doi.org/10.1002/14356007.q20_q05 IS - Chapter 2.3 SP - 47 EP - 60 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim ET - 8th Ed. AN - OPUS4-27635 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Schönbucher, A. A1 - Schälike, Stefan A1 - Vela-Wallenschus, Iris A1 - Wehrstedt, Klaus-Dieter ED - Schmidt, J. T1 - CFD simulation of large hydrocarbon and peroxide pool fires N2 - Accidental fires in process Industries often occur as pool fires, which are hazardous to people and adjacent objects because of thermal radiation, largely sooting plumes and formation of other combustion products [1-3]. In addition to experimental pool fire tests, numerical investigation of these fires using Computational Fluid Dynamics (CFD) codes is becoming more important. In regard to safety, thermal radiation is one ofthe main interests in pool fire research. The Surface Emissive Power (SEP) is a key parameter to characterize thermal radiation emitted by a fire. The derived quantity SEP is usually defined as the heat flux due to thermal radiation in relation to flame surface AF. As well as the SEP, the temperatures Tandirradiances E of pool fires are ofparticular interest. CFD Simulation oflarge pool fires is helpful for abetter understanding of fire dynamics and to reduce the number oflarge-scale experiments. To predict the thermal radiation from the jet engine fuel JP-4 (d = 2, 8,16 and 25 m) and DTBP (di-tert-butyl peroxide, d= 1.12 and 3.4m) pool fires CFD methods are used, and the CFD results are compared with experiments. KW - Pool fire KW - JP 4 KW - Organic peroxide KW - DTBP KW - CFD KW - Surface emissive power KW - Irradiation KW - Safety distances PY - 2012 SN - 978-3-527-33027-0 N1 - Geburtsname von Vela-Wallenschus, Iris: Vela, I. - Birth name of Vela-Wallenschus, Iris: Vela, I. IS - Chapter 9 SP - 139 EP - 157 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-25897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -