TY - CONF A1 - Staude, Andreas T1 - Evidencing the hierachical structure of archaeological ivory at micro and nanoscale and its evolution over time by means of combined µ-SAXS/WAXS, µPIXE and µ-CT T2 - Gordon Research Conference: Scientific Methods in Cultural Heritage CY - Mount Snow Resort, West Dover, VT, USA DA - 2012-07-29 PY - 2012 AN - OPUS4-27877 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas T1 - Non-Sexual Abdominal Appendages in Adult Insects Challenge a 300 Million Year Old Bauplan T2 - HZB Users Meeting 2013 CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29676 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas T1 - Properties of the inner structure of ammonium nitrate prills T2 - HZB Users Meeting 2013 CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29677 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Recknagel, Christoph A1 - Staude, Andreas T1 - Leiser Straßenverkehr - Leise Straßenbeläge KW - Infrastruktur KW - Strukturaufklärung KW - Leise Fahrbahnbeläge PY - 2014 UR - http://www.strassenforschung.de/ SP - 1 EP - 44(?) AN - OPUS4-31452 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schulze, M. A1 - Staude, Andreas A1 - Neukamm, M. A1 - Neuschaefer-Rube, U. A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Bellon, Carsten A1 - Hilpert, U. ED - Weckenmann, A. T1 - Hochgenaue Geometriebestimmung von Mikrobauteilen mit Computertomographie (CT) N2 - Ziel des Vorhabens ist die hochgenaue und vollständige Erfassung innerer und äußerer Geometrien von Mikrobauteilen mittels Mikro-Computertomographie (µCT). Industriell wichtige Mikrobauteile sind z.B. Einspritzsysteme, Festplattenkomponenten oder Instrumente für die minimal-invasive Chirurgie. Typische Bauteilgrößen liegen hier im Bereich 0,1 mm - 100mm; typische zu messende Strukturen haben Größen von 0,5 µm - 500 µm. Mit klassischen Methoden der Messtechnik ist eine schnelle und hochgenaue Erfassung der gesamten Oberfläche von Mikrobauteilen bisher kaum möglich. Innenstrukturen von Mikrobauteilen können mit keiner optischen oder taktilen Messtechnik zerstörungsfrei gemessen werden. Diese Einschränkungen sollen mittels hochgenauer µCT überwunden werden. Hierzu soll der Messprozess simuliert werden, um die Anwendung von Korrekturverfahren zur Genauigkeitssteigerung zu ermöglichen. CT-Messungen an kalibrierten Mikroprüfkörpern sollen die Korrekturverfahren verifizieren. Für die Kalibrierung der Prüfkörper sollen Multisensor-Verfahren entwickelt und getestet werden. Diese sollen es erlauben, Prüfkörper gleichzeitig hochgenau und mit großer Messpunktdichte zu kalibrieren. Es ist geplant, die an Prüfkörpern erreichten Messunsicherheiten und Auflösungen zum Projektabschluss an realen, industriellen Mikrobauteilen (z.B. Mikrozahnrädern) messtechnisch nachzuweisen. T2 - Abschlusskolloquium DFG Schwerpunktprogramm 1159 - Neue Strategien der Mess- und Prüftechnik für die Produktion von Mikrosystemen und Nanostrukturen CY - Erlangen, Deutschland DA - 06.10.2010 PY - 2011 SN - 978-3-8440-0358-1 SN - 0945-0769 SP - 36 EP - 52 PB - Shaker Verlag GmbH AN - OPUS4-24875 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rifai, Haifa A1 - Staude, Andreas A1 - Meinel, Dietmar A1 - Illerhaus, Bernhard A1 - Bruno, Giovanni T1 - In-situ pore size investigations of loaded porous concrete with non-destructive methods N2 - Subject of this investigation is the in-situ evolution of pore volume and pore size distribution in Ytong (a porous concrete material) under increasing pressure with two different non-destructive analytical methods: Nuclear Magnetic Resonance (NMR) and X-ray Computed Tomography (CT). For both methods special strain devices to apply external pressure were constructed. The results from the two techniques yield complementary information on the pore size distribution and allows covering different pore size regions. KW - Pore size KW - Porous concrete KW - Computed tomography KW - Nuclear magnetic resonance PY - 2018 DO - https://doi.org/10.1016/j.cemconres.2018.06.008 SN - 0008-8846 SN - 1873-3948 VL - 111 SP - 72 EP - 80 PB - Elsevier Ltd. AN - OPUS4-45617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zocca, Andrea A1 - Wirth, Cynthia A1 - Staude, Andreas A1 - Bernardo, E. A1 - Günster, Jens A1 - Colombo, P. T1 - SiOC ceramics with ordered porosity by 3 D-printing of a preceramic polymer N2 - Ceramic parts possessing an ordered porosity were produced for the first time by powder-based three-dimensional printing of a preceramic polymer followed by pyrolysis in an inert atmosphere. The main parameters involved in the process were investigated, and the precision of the printed and ceramized parts was assessed by means of scanning electron microscopy and micro computed tomography. The influence of two different printing solvents was investigated and the use of a mixture of 1-hexanol and hexylacetate in particular allowed the production of parts with a relative density of 80% both in the polymeric and in the ceramic state. The mixing of a cross-linking catalyst directly with the printing liquid greatly simplified the process, minimizing the necessity of preprocessing the starting powder. Three-dimensional printing of a preceramic polymer not containing any inert or active fillers was proved to be a feasible, convenient and precise process for the production of porous ceramic possessing a complex, ordered structure, such as stretch-dominated lattices. KW - Polymer KW - Ceramic KW - Cellular PY - 2013 DO - https://doi.org/10.1557/jmr.2013.129 SN - 0884-2914 N1 - Geburtsname von Wirth, Cynthia: Gomes, C. M. - Birth name of Wirth, Cynthia: Gomes, C. M. VL - 28 IS - 17 SP - 2243 EP - 2252 PB - Materials Research Society CY - Warrendale, Pa. AN - OPUS4-29441 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Ritter, Z. A1 - Staude, Andreas A1 - Prohaska, S. A1 - Felsenberg, D. ED - Naik, G. R. T1 - Osteocytes characterization using synchrotron radiation CT and finite element analysis N2 - Since a correlation between osteocyte number and their morphology with bone aging or its response to pharmacological treatment appears to exist, a methodology to characterize osteocytes from bone biopsies becomes important. In this chapter, the usage of synchrotron measurements, algorithms for image analysis (Amira, ZIB), and the finite element method using parallelized computational resources for topological analysis of osteocytes is explained and discussed. Different routines normally applied for material characterization of network-like structures (skeletonization) have been adapted to visualize osteocytes along bone cement lines at high resolution (2.174 µm). The different steps concerning to counting osteocytes and analyzing the mechanical behavior of bones are illustrated with an example. Our findings showed a clear alignment of the osteocytes along the cement lines. Interestingly, at the regions near the bone surface with reduced mineralization grade, osteocytes were mainly aligned along the close to high mineralized region. Apparently, not only osteocytes number is reduced with aging but their size increases and they become sparely distributed in comparison with the healthy bone samples from the human mandible. Automatic tetrahedron mesh generation using the "tetragen" tool from Amira worked adequately for meshing the biopsies with a resolution of 20 µm, but meshing biopsies with osteocytes embedded on the bone matrix from the SR-CT samples consumes an enormous amount of time, due to necessary adjustments for avoiding intersections and conserving model closeness. KW - CT KW - Finite element analysis KW - Osteocytes characterization KW - Synchrotron radiation PY - 2012 SN - 978-953-51-0412-4 DO - https://doi.org/10.5772/35242 SP - 165 EP - 190 PB - InTech CY - Rijeka AN - OPUS4-25845 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scholtz, G. A1 - Staude, Andreas A1 - Dunlop, J.A. T1 - Trilobite compound eyes with crystalline cones and rhabdoms show mandibulate affinities N2 - Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata. KW - Trilobite compound eyes KW - Computed Tomography PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-510784 DO - https://doi.org/10.1038/s41467-019-10459-8 SN - 2041-1723 VL - 10 SP - 2503 PB - Nature AN - OPUS4-51078 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartscher, M. A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Ramsey, A. T1 - The influence of data filtering on dimensional measurements with CT N2 - Data processing is an essential part of the evaluation of measurement results, e.g. in X-ray computed tomography (CT). Some of these calculations are denoted as "filtering". Filtering is always a trade-off between an enhancement of data quality and a loss of information. The standard reconstruction technique for CT data is the filtered back-projection. Additionally to the high-pass filter inherent to this technique, a suppression of high-frequency noise is in most cases also necessary. Many different possible filter algorithms are found in the literature. Although their effect on the signal-to-noise ratio and the spatial resolution is well-studied, it is not obvious how the different filters affect the determination of the object's surface in the reconstructed data and, thus, the results of dimensional CT measurements. We compare the results of industrial dimensional CT measurements obtained at the same data set of a calibrated reference standard – a calotte cube – when using different filters and discuss the implications. Filters under investigation are mainly median filters on projections and as well filters during filtered backprojection and filters on the reconstructed volume. T2 - 18th WCNDT - World Conference on Non-Destructive Testing CY - Durban, South Africa DA - 16.04.2012 KW - Computed tomography (CT) KW - Dimensional measurement KW - Data filtering KW - Resolution PY - 2012 UR - http://www.ndt.net/?id=12600 SN - 978-0-620-52872-6 SP - 1 EP - 13 PB - South-African Institute for Non-Destructive Testing (SAINT) CY - Lynnwood Ridge AN - OPUS4-26252 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas T1 - The Influence of data filtering on dimensional measurements with CT T2 - 18th WCNDT - World Conference on Non-Destructive Testing CY - Durban, South Africa DA - 16.04.2012 PY - 2012 AN - OPUS4-26126 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Staude, Andreas A1 - Scholtz, G. A1 - Dunlop, J. A. T1 - Trilobite compound eyes with crystalline cones and rhabdoms show mandibulate affinities N2 - Most knowledge about the structure, function, and evolution of early compound eyes is based on investigations in trilobites. However, these studies dealt mainly with the cuticular lenses and little was known about internal anatomy. Only recently some data on crystalline cones and retinula cells were reported for a Cambrian trilobite species. Here, we describe internal eye structures of two other trilobite genera. The Ordovician Asaphus sp. reveals preserved crystalline cones situated underneath the cuticular lenses. The same is true for the Devonian species Archegonus (Waribole) warsteinensis, which in addition shows the fine structure of the rhabdom in the retinula cells. These results suggest that an apposition eye with a crystalline cone is ancestral for Trilobita. The overall similarity of trilobite eyes to those of myriapods, crustaceans, and hexapods corroborates views of a phylogenetic position of trilobites in the stem lineage of Mandibulata. KW - Coputed tomography KW - Crystalline cones PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-483889 DO - https://doi.org/10.1038/s41467-019-10459-8 SN - 2041-1723 VL - 10 SP - 2503, 1 EP - 7 PB - Nature AN - OPUS4-48388 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Staude, Andreas A1 - Meinel, Dietmar A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. ED - Grellmann, W. ED - Frenz, H. T1 - Moderne bildgebende hochauflösende Röntgenverfahren für die Materialcharakterisierung N2 - Die Computertomographie (CT) ist in der Medizin als Standardtechnik etabliert, in der zerstörungsfreien Prüfung wird sie zunehmend angewendet, in einzelnen Fällen sogar als Referenzverfahren eingesetzt. Gegenwärtig ist eine starke Zunahme von Anwendungen der CT in der Materialcharakterisierung zu verzeichnen. Zudem werden weitere moderne 3D-Techniken für werkstoffwissenschaftliche Fragestellungen genutzt, um die Mikrostruktur - auch in situ (z.B. Druck, Temperatur) - aufzuklären. Hier werden neben der konventionellen Absorptions-CT auch die Potenziale der Refraktions-CT zur Beantwortung prozesstechnischer sowie werkstofflicher Fragestellungen aufgezeigt, die ein „ganzheitliches Bild“ des jeweiligen Werkstoffs zum Ziel haben. T2 - Tagung Werkstoffprüfung 2014 - Fortschritte in der Werkstoffprüfung für Forschung und Praxis - Werkstoffeinsatz, Qualitätssicherung und Schadensanalyse CY - Berlin, Germany DA - 04.12.2014 KW - Computer tomography KW - X-ray refraction KW - Ceramics KW - Concrete KW - Inhomogeneous materials KW - Computertomographie KW - Röntgenrefraktion KW - Keramik KW - Beton KW - Mehrphasige Materialien PY - 2014 SN - 978-3-9814516-8-9 SN - 1861-8154 SP - 1 EP - 12 AN - OPUS4-32565 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas A1 - Goebbels, Jürgen T1 - Ortsauflösung in der Computertomographie - Vergleich von MTF und Linienpaarstrukturen N2 - Anhand von Messungen an geeigneten Prüfkörpern werden die beiden etablierten Verfahren zur Bestimmung der räumlichen Auflösung von CTDaten (MTF und Kontrast von Linienpaaren), wie in den entsprechenden Normen beschrieben, durchgeführt und ihre Ergebnisse verglichen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-249775 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Mo.3.B.1) SP - 1 EP - 10 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-24977 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Bartscher, M. A1 - Goebbels, Jürgen A1 - Koch, M. A1 - Staude, Andreas T1 - Einfluss von Materialkombinationen auf das dimensionelle Messen mit Mikro-Computertomographie am Beispiel eines werkstücknahen Testkörpers N2 - Die Computertomographie (CT) hat sich als dimensionelle Messmethode in der industriellen Produktion etabliert. Durch Messungen an speziellen Prüfkörpern ist es möglich, quantitative Informationen über die metrologischen Eigenschaften dimensioneller Messungen zu erhalten. In dieser Arbeit wird einen Aluminium-Guss-Prüfkörper (120 mm x 90 mm x 60 mm) benutzt, mit dem – in der vorliegender Form – auch der Einfluss von Materialien unterschiedlicher Schwächung auf dimensionelle CT-Messungen untersucht werden kann. Der Prüfkörper ist in vier Segmente zerteilt, so dass auch innenliegende, raue Gussfreiformflächen der taktilen Koordinatenmessung zugänglich sind. Durch adaptierte Rubinkugeln als Referenzstrukturen können die CT-Messdaten in taktile Referenz-Koordinatensysteme überführt werden. Um den Einfluss von Materialien unterschiedlicher Schwächung auf das dimensionelle Messen mit CT zu untersuchen, wurden stärker schwächende ZTA-Störkugeln (Zirconia Toughened Alumina) mit zur Ausrichtung geeigneter Symmetriebrechung in der Nähe von ausgewählten taktilen Messstellen angebracht. Zur Bewertung der Messabweichungen dienen taktile Referenzmessungen an den ZTA-Kugeln sowie taktile Messungen an den Freiformflächen des Gussteils, wobei durch ein iteratives Antastverfahren eine verbesserte Erfassung der Geometrie auch bei starken lokalen Oberflächenkrümmungen sichergestellt wird. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Mikro-CT KW - Dimensionelles Messen KW - Testkörper KW - Multimaterial PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-248878 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Di.1.B.2) SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-24887 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartscher, M. A1 - Ehrig, Karsten A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Neuschaefer-Rube, U. T1 - Application of an industrial CT reference standard for cast freeform shaped workpieces N2 - Industrial computed tomography (CT) today is an important method to analyze defects and to measure the geometry of technical products. The measurement capability of industrial CT often depends on the knowledge of the measurement errors being present. Only with this knowledge, effective corrections are possible by manufacturers, or adapted measurement procedures become possible for the customers. Thus, there is the strong need to have adequate reference standards both for the assessment of general dependencies and for the measurement of task-specific effects. Especially the latter are difficult to assess. This paper shows the application of a versatile dismountable workpiece-near reference body for the use with CT. The reference standard was made from a miniaturized cast aluminium (one-)cylinder head. It can be dismounted into four segments, each featuring reference geometries which enable a registration of CT measured and other reference datasets (e.g. from tactile CMM). The reference standard embodies complex freeform surfaces which are a challenging measurement task for CT and other sensors. Here the application of the reference standard is the study of the influence of material mixes. This is realized by adding pieces of other materials which disturb the mono-material measurement. Results of the application of the reference standard are presented using data from industrial micro-CT systems and CMM reference data. A special emphasis is given on the workflow of the data processing and the data analysis. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Industrial reference standard KW - Computed tomographie KW - Freeform shaped workpieces PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245532 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (We.4.3) SP - 1 EP - 12 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Staude, Andreas A1 - Goebbels, Jürgen T1 - Determining the spatial resolution in computed tomography - comparison of MTF and line-pair structures N2 - According to the relevant standards, measurements of suitable test pieces are analysed with the two established methods to determine the spatial resolution of CT data (MTF and contrast of line-pairs). The results are compared and differences are discussed. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-245544 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Tu.4.1) SP - 1 EP - 9 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Godehardt, M. A1 - Krebs, Holger A1 - Ohser, J. A1 - Staude, Andreas T1 - Analyse der Porengrößenverteilung in einer myCT-Aufnahme eines Sprengstoffes N2 - An der BAMIine von BESSY II wurden durch Mikro-Computertomographie (pCT) 3D-Bilder der Mikrostruktur von drei verschiedenen Explosivstoffen aufgenommen (Probennummern 2075, 2076, 2077), von denen zunächst nur der 3DDatensatz von Probe 2075, eines mit Mikrohohlkugeln sensibilisierten Emulsionssprengstoffes, analysiert wurde. Für die anderen Proben erschien der Aufwand zur Charakterisierung der Mikrostruktur zu hoch bzw. muss die Zielstellung der Analyse noch klarer formuliert werden. PY - 2012 SN - 0941-4584 VL - 34 IS - 1 SP - 3 EP - 4 PB - Deutscher Sprengverband CY - Siegen AN - OPUS4-27976 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -