TY - CONF A1 - Simon, Fabian T1 - An improved method for the determination of PFASs using HR CS GFMAS via GaF detection N2 - Introduction Per- and polyfluorinated alkyl substances (PFASs) are a group of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their various chemical and physical properties as well as the high number of compounds. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate realistic PFAS pollution levels. Methods For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. In our study we used high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) which is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L. Results Here, we present an improved method for the determination of PFASs using HR-CS-GFMAS via GaF detection. The optimized method includes a modifier pretreatment step using a mixture of Mg, Pd and Zr and a correction measurement using perfluorooctanoic acid. The combination of both resulted in increased accuracy and precision as well as overall lower detection limits. Furthermore, during optimization the influence of species-specific responses during HR-CS-GFMAS analysis was reduced resulting in a more accurate determination of PFAS sum parameters. To test the applicability of the improved method, we analysed soil samples from a former fire-fighting training area combining the improved method for detection with our previously optimized extraction method for extractable organically bound fluorine (EOF) determination in soils. Innovative aspects • Highly sensitive and selective method for fluorine/PFASs analysis based on HR-CS-GFMAS • Increased accuracy for the determination of EOF • Reduction of PFAS species-specific responses by optimized modifier conditions T2 - ANAKON23 CY - Vienna, Austria DA - 11.04.2023 KW - PFAS KW - HR-CS-GFMAS KW - Fluorine PY - 2023 AN - OPUS4-57409 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zweigle, J. A1 - Capitain, C. A1 - Simon, Fabian Michael A1 - Roesch, Philipp A1 - Bugsel, B. A1 - Zwiener, C. T1 - Non-extractable PFAS in functional textiles − Characterization by complementary methods: oxidation, hydrolysis, and fluorine sum parameters N2 - Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles like outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient in detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP assay, PhotoTOP), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, oxidation by dTOP and PhotoTOP and also hydrolysis by the THP are able to capture large fractions of the TF in form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) were much lower (e.g., factor ~25-50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from 84% at all sampling sites. Mass balance approach (ii) showed that the unidentified EOF (uEOF) fraction increased over time from82% (2005) to 99% (2019). Furthermore, along the river courses the uEOF increased. In the combined mass balance approach (iii) using 4 different analytical approaches EOF fractions were further unraveled. The EOF pattern was fully explainable at the sampling sites at Saar and Elbe rivers. For the time resolved analysis, an increased proportion of the EOF was now explainable. However, still 27% of the EOF for the time resolved analysis and 25% of the EOF for the spatial resolved analysis remained unknown. Therefore, in a complementary approach, both the EOF and dTOPA reveal unknown gaps in the PFAS mass balance and are valuable contributions to PFAS risk assessment. Further research is needed to identify organofluorines summarized in the EOF parameter. KW - PFAS KW - HR-CS-GFMAS KW - Fluorine KW - SPM KW - LC-MS/MS PY - 2023 DO - https://doi.org/10.1016/j.scitotenv.2023.163753 SN - 1879-1026 SN - 0048-9697 VL - 885 SP - 1 EP - 12 PB - Elsevier Science CY - Amsterdam AN - OPUS4-57429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Simon, Fabian T1 - Analyse von PFAS mittels (Non-)Target HRMS, dTOPA und EOF in Schwebstoff-Proben aus Zeitreihen der Umweltprobenbank N2 - Per- und polyfluorierte Alkylverbindungen (PFAS) sind eine Substanzklasse bestehend aus mehreren tausenden Einzelverbindungen. Unter PFAS zählen alle Verbindungen, die mindestens eine perfluorierte Methyl- (-CF3) oder Methylen-Gruppe (-CF2-) besitzen.[1] Somit zählt auch ein großer Teil der fluorierten Medikamente, Pflanzenschutzmittel oder Biozide in die PFAS-Substanzklasse. Aufgrund der Persistenz, Bioakkumulation in Nahrungsketten, Toxizität und der ubiquitären Verbreitung von PFAS zählen sie zu den „emerging pollutants“.[2] Die PFAS-Analytik ist wegen ihrer vielfältigen physikalisch-chemischen Eigenschaften und der sehr hohen Anzahl an PFAS eine große Herausforderung. Da es für viele Anwendungen noch ungewiss ist, welche PFAS verwendet werden, wie sie in die Umwelt gelangen und welche Transformations- bzw. Abbauprodukte entstehen, stoßen analytische Ansätze, die nur auf Einzelsubstanzen abzielen, hier an ihre Grenzen. PFAS-Summenparameter-Methoden, die darauf abzielen ein möglichst vollständiges Abbild der PFAS-Belastungssituation widerzuspiegeln, werden daher immer wichtiger. T2 - Wasser 2023 CY - Augsburg, Germany DA - 14.05.2023 KW - PFAS KW - HR-CS-GFMAS KW - Fluorine KW - SPM KW - Schwebstoffe KW - LC-HRMS PY - 2023 AN - OPUS4-57516 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pienkoß, Fabian A1 - Kalbe, Ute A1 - Simon, Franz-Georg T1 - Nassmechanische Aufbereitung von Bauschutt‐Brechsand mit der Setztechnik – ein Schritt auf dem Weg zum Ersatzbaustoff T1 - Wet-Mechanical Processing of Crushed-Sand from Construction-Waste - A First Step Towards a Circular Building Material N2 - Das Recycling von gemischten Baustoffen führt neben der Herstellung von Gesteinskörnungen parallel zu einem stärker schadstoffbelasteten Stoffstrom, der circa ein Drittel der ursprünglichen Masse ausmacht. Dieser sogenannte Brechsand endet derzeit in der Deponierung und wird somit der Kreislaufwirtschaft entzogen. Der vorliegende Beitrag untersucht nun die Aufbereitung dieses Materials unter Verwendung einer Setzmaschine im Pilotmaßstab. Hierbei wird die Eignung dieser Technik evaluiert und das Aufbereitungsprodukt als möglicher Ersatzbaustoff untersucht. N2 - Besides the generation of aggregates, recycling of mixed construction and demolition waste leads to a more polluted side stream accounting for up to one third of the input materials. This so-called crushed sand often ends up in landfills and is hence lost for a circular economy. This article reports about the processing of this material using a pilot plant jig. The suitability of jigging technology is evaluated, and the product is analyzed as possible circular building material. KW - Aufbereitung KW - Ersatzbaustoff KW - Kreislaufwirtschaft KW - Setzmaschine KW - Umweltverträglichkeit PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-585978 DO - https://doi.org/10.1002/cite.202300019 SN - 0009-286X VL - 95 IS - 12 SP - 1916 EP - 1924 PB - Wiley VHC-Verlag AN - OPUS4-58597 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -