TY - CONF A1 - Simon, Fabian T1 - A fast and simple PFAS extraction method for soil sample analysis using HR-CS-GFMAS N2 - Per- and polyfluorinated alkyl substances (PFASs) are a substance class of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their different chemical and physical properties as well as the high number of target substances. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate a realistic PFAS pollution level. PFAS sum parameters compromise the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for indirect fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L. Here, we describe a fast and simple extraction method for the determination of the EOF using HR-CS-GFMAS in soil samples. Common approaches for the EOF determination use solid phase extraction (SPE). To omit the bias of this time consuming and expensive step we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol. Comparison of the method with and without an SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. In the next step, the applicability of our method was tested for other solid matrices. In view of steadily increasing numbers of PFASs, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFASs in the future. T2 - Analytica conference CY - München, Germany DA - 21.06.2022 KW - PFAS KW - HR-CS-GFMAS KW - Soil KW - Fluorine KW - SPE PY - 2022 AN - OPUS4-55124 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Simon, Fabian T1 - Development of multi-layer SPE approaches for PFAS determination in surface water samples utilizing HR-CS-GFMAS N2 - Per- and polyfluoroalkyl substances (PFAS) have received global public attention because of their wide distribution in aquatic environments and potential adverse effects to humans and wildlife. Due to the lack of analytical standards and the enormous numbers of these compounds, current target-based methods (e.g., LC-MS/MS) are not suitable for the analysis of new/unknown PFAS and transformation products. Therefore, PFAS sum parameter analysis is becoming increasingly important. For PFAS determination of surface waters, solid phase extraction (SPE) is commonly implemented for clean-up and pre-concentration of samples. Thus, within this work, single-layer SPE methods (based on Strata™-X, Strata™-X-AW, Strata™-NH2 and Oasis-HLB) were investigated for maximum PFAS coverage utilizing extractable organically bound fluorine (EOF) analysis. Thereby, the optimization procedure relied on the analysis of 3 surface water samples in Berlin, Germany, which were affected by the effluent discharge of wastewater treatment plants. To analyse the SPE elution profiles for EOF and inorganic fluorine, high resolution-continuum source-graphite furnace molecular absorption spectroscopy (HR-CS-GFMAS) and ion chromatography (IC) were used, respectively. Highest EOF concentrations were achieved by using Strata-X/Strata-XAW as SPE sorbents and methanol as eluent. Furthermore, combinations of the most promising SPE sorbents were selected (X/XAW, XAW/X, HLB/X and WAX/GCB) to extract a wider range of PFASs. By comparing multi-layer SPE methods, lower EOF concentrations were obtained for all investigated combination phases compared to the analysed single phases. For the commercially available combination phase Strata-PFAS (WAX/GCB) for all three river water samples, lower EOF concentrations (1.5 times lower) were determined compared to Strata-X. The results have shown that single-layer SPE systems are currently superior compared to combination phases for PFAS sum parameter analysis. The multi-layer SPE methods need further optimization regarding appropriate sorbent combinations, loading volumes and elution conditions. The developed single-layer SPE methods can help to elucidate pollutions hotspots and discharge routes. T2 - Analytica Conference 2024 CY - Munich, Germany DA - 09.04.2024 KW - PFAS KW - HR-CS-GFMAS KW - Fluorine KW - SPE PY - 2024 AN - OPUS4-59890 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Simon, Fabian T1 - HR-CS-GFMAS a new screening tool for per- and polyfluoroalkyl substances (PFAS) in the environment N2 - Per- and polyfluorinated alkyl substances (PFASs) are a large group of anthropogenic contaminates. Concerning are especially their persistent, bioaccumulative and toxic properties. Mostly, target-based approaches (e.g., LC-MS/MS) are utilized for the analysis of PFASs in the environment. But these approaches are limited to the availability of analytical grade standards and therefore drastically underestimate the total PFAS burden. Analytical approaches based on total fluorine for PFAS sum parameter analysis become increasingly important to indicate realistic PFAS pollution levels. PFAS sum parameters display the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. Besides combustion ion chromatography (CIC), high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification in the low µg F L-1 range. Here, we present a comparison of total fluorine analysis methods – AOF vs. EOF and HR-CS-GFMAS vs. CIC. Therefore, surface water samples from the Spree River in Berlin, Germany were analyzed at 10 locations for total fluorine (TF), AOF and EOF. The AOF made up 0.14–0.81% of TF and the EOF 0.04–0.28% of TF while AOF concentrations were systematically higher. For the instrumental comparison, HR-CS-GFMAS was the more sensitive and precise method for fluorine analysis compared to CIC. T2 - ICOBTE / ICHMET 2023 CY - Wuppertal, Germany DA - 06.09.2023 KW - PFAS KW - HR-CS-GFMAS KW - Fluorine KW - WWTP KW - SPE PY - 2023 AN - OPUS4-58245 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -