TY - JOUR A1 - Karrasch, Stefan A1 - Simon, M. A1 - Herbig, Britta A1 - Langner, Jeanette A1 - Seeger, Stefan A1 - Kronseder, A. A1 - Peters, S. A1 - Dietrich-Gümperlein, G. A1 - Schierl, R. A1 - Nowak, D. A1 - Jörres, R.A. ED - Nazaroff, William T1 - Health effects of laser printer emissions: a controlled exposure study N2 - Ultrafine particles emitted from laser printers are suspected to elicit adverse health effects. We performed 75-minute exposures to emissions of laser printing devices (LPDs) in a standardized, randomized, cross- over manner in 23 healthy subjects, 14 mild, stable asthmatics, and 15 persons reporting symptoms associated with LPD emissions. Low-level exposures (LLE) ranged at the particle background (3000 cm−3) and High-level exposures (HLE) at 100 000 cm−3. Examinations before and after exp sures included spirometry, body plethysmography, transfer factors for CO and NO (TLCO, TLNO), bronchial and alveolar NO, cytokines in serum and nasal secretions (IL-1β, IL-5, IL-6, IL-8, GM-CSF, IFNγ, TNFα), serum ECP, and IgE. Across all participants, no statistically significant changes occurred for lung mechanics and NO. There was a decrease in volume-related TLNO that was more pronounced in HLE, but the difference to LLE was not significant. ECP and IgE increased in the same way after exposures. Nasal IL-6 showed a higher increase after LLE. There was no coherent pattern regarding the responses in the participant subgroups or single sets of variables. In conclusion, the experimental acute responses to short but very high-level LPD exposures were small and did not indicate clinically relevant effects compared to low particle number concentrations. KW - Emission KW - Exposure KW - Laser printer KW - Lung function KW - Respiratory health KW - Ultrafine particles PY - 2017 DO - https://doi.org/10.1111/ina.12366 SN - 1600-0668 VL - 27 IS - 4 SP - 753 EP - 765 PB - John Wiley & Sons Ltd. CY - London AN - OPUS4-42593 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reinsch, Stefan A1 - Böcker, Wolfgang D. G. A1 - Bücker, Michael A1 - Seeger, Stefan A1 - Unger, Brita ED - Specht, K. T1 - Development of wood-inorganic composites with enhanced properties and environmental stability T2 - 4th International Wood and Natural Fibre Composites Symposium CY - Kassel, Germany DA - 2002-04-10 PY - 2002 VL - 4 SP - 50-1-50-6 CY - Kassel AN - OPUS4-1365 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Dörfel, Ilona A1 - Steinborn, Gabriele A1 - Langner, Jeanette A1 - Krietsch, Arne A1 - Seeger, Stefan A1 - Österle, Werner A1 - Schmidt, Martin A1 - Bresch, Harald T1 - Dossier on titanium dioxide - Part 1/1 - NM 105 N2 - In November 2007, OECD’s Working Party on Manufactured Nanomaterials (WPMN) launched the Sponsorship Programme for the Testing of Manufactured Nanomaterials (hereafter the Testing Programme). The objective was to conduct specific tests, relevant to human health and environmental safety endpoints, on a variety of manufactured nanomaterials (MN). The outcomes of the Testing Programme were intended to assess the applicability of the existing test guidelines1 to nanomaterials, as well as to provide useful information on any intrinsic properties of MNs, which are different from the same bulk material with greater external dimensions. Understanding the properties of NMs is crucial to choose appropriate strategies for hazard identification, risk assessment or risk management measures. The Testing Programme involved delegations from OECD member countries, some non-member economies and other stakeholders. The broad international representation, from a range of delegations enabled the programme to pool expertise and resources without which this programme would not have been possible. KW - Nanomaterial KW - Nanoparticle KW - Sponsorship programme KW - Nano characterization PY - 2015 UR - http://www.oecd.org/env/ehs/nanosafety/dossier-on-silver-nanoparticles-part1-1.htm IS - 54 SP - 27 CY - Paris AN - OPUS4-35430 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bucar, K. A1 - Malet, J. A1 - Stabile, L. A1 - Pražnikar, J. A1 - Seeger, Stefan A1 - Žitnik, M. T1 - Statistics of a Sharp GP2Y Low-Cost Aerosol PM Sensor Output Signals N2 - In this work, we characterise the performance of a Sharp optical aerosol sensor model GP2Y1010AU0F. The sensor was exposed to different environments: to a clean room, to a controlled atmosphere with known aerosol size distribution and to the ambient atmosphere on a busy city street. During the exposure, the output waveforms of the sensor pulses were digitised, saved and a following offline analysis enabled us to study the behaviour of the sensor pulse-by-pulse. A linear response of the sensor on number concentration of the monosized dispersed PSL particles was shown together with an almost linear dependence on particle diameters in the 0.4 to 4 micrometer range. The gathered data about the sensor were used to predict its response to an ambient atmosphere, which was observed simultaneously with a calibrated optical particle counter. KW - Aerosol KW - Partikel KW - Aerosolsensor KW - Luftgüte KW - Umweltmessung PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517466 DO - https://doi.org/10.3390/s20236707 SN - 1424-8220 VL - 20 IS - 23 SP - 6707 PB - MDPI CY - Basel, Schweiz AN - OPUS4-51746 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kayser, Y. A1 - Gross, A. A1 - Hönicke, P. A1 - Osan, J. A1 - Pollakowski-Herrmann, B. A1 - Seeger, Stefan A1 - Beckhoff, B. T1 - Reliable chemical analysis of aerosols by reference-free X-ray spectrometry for monitoring airborne particulate matter N2 - The physical and chemical analysis of aerosols using reliable and physically traceable methods is important for the thorough investigation of airborne particles to support a better understanding of their origin as well as their health and climate impacts. Within the European Metrology Research AeroMet project,the aim of hysikalisch–Technische Bundesanstalt’s (PTB) X-ray spectrometry group is to develop and establish traceable and reliable X-ray methods to measure the elemental mass deposition per unit area, the elemental composition,and the chemical binding state of particulate matter supported by a flat substrate. This approach can substantially contribute to support quantitative analytical methods during on-site measurement campaigns where portable Instrumentation is employed by qualifying suitable calibration samples for commercial analytical X-ray instruments and by investigating samples collected during the field campaign. KW - AEROMET project KW - X-Ray analysis KW - TXRF KW - Aerosols KW - Particles KW - Air pollution KW - Elemental composition PY - 2020 UR - https://www.spectroscopyonline.com/view/reliable-chemical-analysis-of-aerosols-by-reference-free-x-ray-spectrometry-for-monitoring-airborne-particulate-matter SN - 0887-6703 VL - 35 IS - 10 SP - 42 EP - 46 PB - MJH Life Sciences CY - Cranbury, NJ AN - OPUS4-53357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Element mass concentrations in ambient aerosols, a comparison of results from filter sampling & ICP-MS ans cascade impactor sampling & mobile total reflection X-RAY fluorescence spectroscopy N2 - Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments and required by EU air quality regulations. Typically, airborne particles are sampled on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). Within the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling was combined with on-site total reflection X-ray fluorescence (TXRF) spectroscopy. The study aimed at a proof of principles for this new mobile and on-size tool for the quantification of aerosol element compositions and element mass concentrations within short time intervals of less than 12 h. In a field campaign the method’s technical feasibility could be demonstrated. The TXRF results were traced back to a stationary, reference-free XRS setup in the laboratory of the German national metrology institute PTB at the BESSY II electron storage ring in Berlin, Germany. Simultaneous PM10-filter sampling, followed by standardized lab-based analysis, allowed for a comparison of the field campaign data of both methods. As Fig. 1 shows, the correspondence between PM10 filter sampling and ICP-MS, and on the other hand, cascade impactor sampling and TXRF is quite encouraging. However, for some of the analysed elements, e.g. V and Pb, the observed deviations are higher than expected and this highlights the fact, that spectral deconvolution strategies for TXRF on cascade impactor samples still need some improvement. This work was supported by the EMPIR programme, co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme, through grant agreements 16ENV07 AEROMET and 19ENV08 AEROMET II T2 - 12th International Conference on Instrumental Methods of Analysis (IMA-2021) CY - Athens, Greece DA - 20.09.2021 KW - Aerosol KW - TXRF KW - Reference method KW - Cascade impactor KW - Ambient aerosols KW - Air quality monitoring KW - Element mass concentration KW - Size resolved chemical composition KW - Time resolved chemical composition KW - ICP-MS PY - 2021 AN - OPUS4-53597 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Asbach, C. A1 - Held, A. A1 - Kiendler-Scharr, A. A1 - Scheuch, G. A1 - Schmid, H.-J. A1 - Schmitt, S. A1 - Schumacher, S. A1 - Wehner, B. A1 - Weingartner, E. A1 - Weinzierl, B. A1 - Bresch, Harald A1 - Seeger, Stefan A1 - u.a., T1 - Position paper of the Gesellschaft für Aerosolforschung on understanding the role of aerosol particles in SARS-CoV-2 infection N2 - Many studies have already shown that viruses can spread via aerosol particles. An aerosol is a mixture of air with solid or liquid particles dispersed in it. To understand the role of aerosol particles as a transmission path of SARS-CoV-2, knowledge of the different processes in an Aerosol is therefore of particular importance. With this paper, GAeF would like to contribute to a better understanding of the term “aerosol” and the relevant aerosol processes. In the context of this paper only the essential basics will be discussed. For a deeper understanding of the partly complex processes, please refer to the literature mentioned at the end of the paper. The paper summarises a large number of studies on the formation of virus-laden aerosol particles and their spread. Based on this, it can be concluded that exhaled aerosol particles may play a prominent role in the spread of viruses in the corona pandemic. Finally, this paper discusses possible measures to reduce the spread of aerosol particles. The measures discussed are based on the current public debate including ventilation, air purifiers, HVAC systems and masks. Advice is given on the correct and sensible use of these measures. An aerosol is always dynamic, as particles are newly formed, transported in or with the air, removed from the air or change in the airborne state. Aerosol particles have sizes between approx. 0.001 and several 100 micrometres (and not < 5 μm as currently defined in many publications) and spread relatively quickly with air currents, even over longer distances. Larger aerosol particles sink to the ground, depending on their size and density, while small aerosol particles can remain in the air for a very long time (see Section 3). Every person emits liquid aerosol particles of various sizes through breathing and when speaking, coughing and sneezing (see Section 4). If a person is infected with a virus, such as SARS-CoV-2, these aerosol particles can contain viruses that can be released into the air and inhaled by other people. SARS-CoV-2 has a size of 0.06 to 0.14 micrometres, but the exhaled liquid aerosol particles are larger. The liquid aerosol particles can shrink by evaporation, depending on the ambient conditions (see Section 3.3). Particle size is relevant for particle transport and particle separation. The highest risk of infection exists in closed indoor spaces, as aerosol particles can accumulate there. Here in particular, appropriate measures must be taken to reduce the concentration of aerosol particles (see Section 5). Against the background of aerosol science, the GAeF classifies the current measures to contain the pandemic as follows: • In principle, no measure can work on its own! According to the current state of knowledge, the interaction of the most varied measures is the best way to minimise the risk of infection. • Keeping distance is important, because with increasing distance, directly exhaled viruses are diluted and the probability of infection decreases. The often prescribed minimum distance can be used as a guide, but it should be increased and supplemented by other measures (see below), especially for longer meetings and also indoors with reduced air movement. • Masks help to filter some of the exhaled particles (and viruses). This reduces the concentration of exhaled particles (and viruses) in a room and thus the risk of infection. It should be noted here that the exhaled aerosol particles are relatively large due to adhering moisture and can therefore also be efficiently retained by simple masks. However, since these particles shrink with longer dwell time in the room air, simple mouth-nose masks are less efficient for self-protection. Respiratory masks are required for this purpose, which show a high degree of separation even for fine particles, e.g. of classes FFP2, N95 or KN95. These are efficient for both self-protection and protection of others unless they have an exhalation valve. Masks with an exhalation valve, on the other hand, are only for self-protection and therefore contradict the solidarity concept that fellow human beings are protected by collective mask wearing. Face shields which are used without additional masks are largely useless with regard t• aerosol particles, as the air with particles (and viruses) flows unfiltered around the shields. In everyday clinical practice, facial shields are worn in addition to masks to prevent droplet infection via the mucous membranes of the eyes. Mobile or permanently installed Plexiglas barriers are also largely ineffective against the spread of aerosols indoors. These can only prevent the smallscale spread of an aerosol in the short term, e.g. in the checkout area of a supermarket, but offer no protection in the longer term. Face shields and Plexiglas panels essentially serve as spit and splash protection against large droplets. • Outdoors, there are practically no infections caused by aerosol transmission. However, droplet infections can still occur, especially in crowds, if minimum distances are not observed and/or masks are not worn. In closed rooms, ventilation is essential to replace the exhaled air in a room with fresh air from outside. Frequent airing and cross-ventilation is just as effective as leaving the window open all the time. From an energy point of view, however, it is more efficient to ventilate the room, especially in winter. CO2 monitors can help to monitor indoor air quality. They indicate when it is necessary to ventilate and when the air in a room has been sufficiently changed during ventilation. However, they can only be used as an indicator and even if the proposed CO2 limit concentrations are met, they do not prevent direct infection by people in the immediate vicinity. • Air purifiers can make a useful contribution to reducing the concentration of particles and viruses in a room. When procuring air purifiers, care must be taken to ensure that they are adequately dimensioned for the room and application in question in order to significantly reduce the particle and virus load. The air throughput of the unit is more important than the pure efficiency of the filter. For energy and cost reasons, the use of highly efficient filters can even be counterproductive. Permanently installed ventilation systems can also be useful, provided they filter the air to reduce the particle and virus load in a room. To avoid infections, it is advisable to operate them with 100 % fresh air if possible. From the point of view of the Gesellschaft für Aerosolforschung, there is a considerable need for research, especially at the interdisciplinary borders to research fields of epidemiology, infectiology, virology, ventilation technology and fluid mechanics. The implementation of targeted studies should be made possible at short notice with special funding and research programmes. This paper was written originally in German by members of the Gesellschaft für Aerosolforschung and is supported by a large number of international aerosol experts. Both the English and German version as well as all images in the paper are available for free download at the following link: https://www.info.gaef.de/positionspapier. The “Gesellschaft für Aerosolforschung e. V.” must be named as the source, whenever an image is used. KW - COVID KW - SARS KW - GAeF KW - Aerosol KW - Corona PY - 2021 UR - https://www.info.gaef.de/_files/ugd/fab12b_d8d88393f90240cdbea63c88c09887ef.pdf DO - https://doi.org/10.5281/zenodo.4350494 SP - 1 EP - 48 PB - Association for Aerosol Research CY - Köln AN - OPUS4-53955 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Osan, J. A1 - Czömpöly, O. A1 - Gross, A. A1 - Stosnach, H. A1 - Stabile, L. A1 - Ochsenkuehn-Petropoulou, M. A1 - Tsakanika, L. A1 - Lymperopoulou, T. A1 - Goddard, S. A1 - Fiebig, M. A1 - Gaie-Levrel, F. A1 - Kayser, Y. A1 - Beckhoff, B. T1 - Quantification of Element Mass Concentrations in Ambient Aerosols by Combination of Cascade Impactor Sampling and Mobile Total Reflection X-ray Fluorescence Spectroscopy N2 - Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing EU air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). During the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling is combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution only a few hours and with good size resolution in the PM10 range. The study investigates the proof of principles of this methodological approach. Acrylic discs and silicon wafers are shown to be suitable impactor carriers with sufficiently smooth and clean surfaces, and a non-destructive elemental mass concentration measurement with a lower limit of detection around 10 pg/m3 could be achieved. We demonstrate the traceability of field TXRF measurements to a radiometrically calibrated TXRF reference, and the results from both analytical methods correspond satisfactorily. KW - TXRF KW - Reference method KW - Cascade impactor KW - Ambient aerosols KW - Particles KW - Air quality monitoring KW - Element mass concentration KW - Size resolved chemical composition KW - Time resolved chemical composition KW - ICP-MS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521860 UR - http://www.aerometproject.com/ DO - https://doi.org/10.3390/atmos12030309 SN - 2073-4433 VL - 12 IS - 3 SP - 309 EP - 337 PB - MDPI CY - Basel, Schweiz AN - OPUS4-52186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horender, S. A1 - Auderset, K. A1 - Quincey, P. A1 - Seeger, Stefan A1 - Skov, S. N. A1 - Dierschel, K. A1 - Smith, T. O.M. A1 - Williams, K. A1 - Aegerter, C. C. A1 - Kalbermatter, D. M. A1 - Gaie-Levrel, F. A1 - Vasilatou, K. T1 - Facility for production of ambient-like model aerosols (PALMA) inthe laboratory: application in the intercomparison of automated PMmonitors with the reference gravimetric method N2 - A new facility has been developed which allows for a stable and reproducible production of ambient-like model aerosols (PALMA) in the laboratory. The set-up consists of multiple aerosol generators, a custom-made flow tube homogeniser, isokinetic sampling probes, and a system to control aerosol temperature and humidity. Model aerosols containing elemental carbon, secondary organic matter from the ozonolysis of α-pinene, inorganic salts such as ammonium sulfate and ammonium nitrate, mineral dust particles,and water were generated under different environmental conditions and at different number and mass concentrations. The aerosol physical and chemical properties were characterised with an array of experimental methods, including scanning mobility particle sizing, ion chromatography, total reflection X-ray fluorescence spectroscopy and thermo-optical analysis. The facility is very versatile and can find applications in the calibration and performance characterisation of aerosol instruments monitoring ambient air. In this study, we performed, as proof of concept, an intercomparison of three different commercial PM (particulate matter) monitors (TEOM1405, DustTrak DRX 8533 and Fidas Frog) with the gravimetric reference method under three simulated environmental scenarios. The results are presented and compared to previous field studies. We believe that the laboratory-based method for simulating ambient aerosols presented here could provide in the future a useful alternative to time-consuming and expensive field campaigns, which are often required for instrument certification and calibration. KW - Model aerosols KW - Intercomparison KW - PM monitors KW - Aerosol gravimetry PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521342 DO - https://doi.org/10.5194/amt-14-1225-2021 VL - 14 IS - 2 SP - 1225 EP - 1238 PB - Copernicus Publications AN - OPUS4-52134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ahlawat, A. A1 - Seeger, Stefan A1 - Gottschalk, Martin A1 - Tuch, T. A1 - Wiedensohler, A. T1 - Observation of systematic deviations between Faraday cup aerosol electrometers for varying particle sizes and flow rates - results of the AEROMET FCAE workshop N2 - Condensation particle counters (CPCs) are widely used for the measurement of aerosol particle number concentrations in the size range from approximately 3 nm to 3 μm. For an SI-traceable calibration of the size-dependent counting efficiency, which is advisable on a regular basis and required in several applications, Faraday cup aerosol electrometers (FCAEs) are considered to be a suitable SI-traceable reference.While the volumetric aerosol inlet flowrate and the electrical current measurement in FCAEs can be related to respective SI references, inter-comparison exercises for FCAEs are still performed on a regular basis to establish reliable uncertainty budgets and to further investigate the influences of designs and operational parameters on comparability. This is strongly demanded in the international community of metrological institutes and aerosol calibration facilities around the world, which provide CPC calibrations. In the present study, the performance of FCAEs was investigated,using Ag test aerosol particles with a 30 nm particle diameter by varying the inlet flowrates from 0.5 l min−1 to 4 l min−1. From our experimental results, significant deviations were observed in FCAE currents at sample flowrates smaller than 1.5 l min−1. It is recommended that these discrepancies should be quantified before an FCAE is used for CPC calibration at low sample flowrates and small particle sizes in the sub-30 nm size range. KW - Faraday cup aerosol electrometer KW - CPC calibration KW - Inter-comparison KW - Aerosol measurement instruments PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-531315 DO - https://doi.org/10.1088/1681-7575/ac0710 SN - 1681-7575 SN - 0026-1394 VL - 58 IS - 5 SP - 1 EP - 8 PB - Institute of Physics (IOP) CY - Bristol, UK AN - OPUS4-53131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tang, Chi-Long A1 - Seeger, Stefan T1 - Systematic ranking of filaments regarding their particulate emissions during fused filament fabrication 3D printing by means of a proposed standard test method N2 - The diversity of fused filament fabrication (FFF) filaments continues to grow rapidly as the popularity of FFF-3D desktop printers for the use as home fabrication devices has been greatly increased in the past decade. Potential harmful emissions and associated health risks when operating indoors have induced many emission studies. However, the lack of standardization of measurements impeded an objectifiable comparison of research findings. Therefore, we designed a chamber-based standard method, i.e., the strand printing method (SPM), which provides a standardized printing procedure and quantifies systematically the particle emission released from individual FFF-3D filaments under controlled conditions. Forty-four marketable filament products were tested. The total number of emitted particles (TP) varied by approximately four orders of magnitude (1E9 ≤ TP ≤ 1E13), indicating that origin of polymers, manufacturer-specific additives, and undeclared impurities have a strong influence. Our results suggest that TP characterizes an individual filament product and particle emissions cannot be categorized by the polymer type (e.g., PLA or ABS) alone. The user's choice of a filament product is therefore decisive for the exposure to released particles during operation. Thus, choosing a filament product awarded for low emissions seems to be an easily achievable preemptive measure to prevent health hazards. KW - Emission test method KW - FFF-printing KW - Particle emission KW - Indoor air quality KW - FFF-filament PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-545087 DO - https://doi.org/https://doi.org/10.1111/ina.13010 SN - 1600-0668 VL - 32 IS - 3 SP - 1 EP - 12 PB - Wiley CY - Hoboken, New Jersey, USA AN - OPUS4-54508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vigna, L. A1 - Gottschalk, Martin A1 - Cacocciola, N. A1 - Verna, A. A1 - Marasso, S. L. A1 - Seeger, Stefan A1 - Pirri, C.F. A1 - Cocuzza, M. T1 - Flexible and reusable parylene C mask technology for applications in cascade impactor air quality monitoring systems N2 - The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates. KW - AEROMET II KW - Aerosol KW - Parylene C KW - Reference samples KW - Flexible shadow masks KW - Cascade impactor KW - Air quality monitoring KW - Micropatterning KW - Mask fabrication KW - Elemental aerosol analysis KW - TXRF PY - 2022 DO - https://doi.org/10.1016/j.mne.2022.100108 SN - 2590-0072 VL - 14 SP - 1 EP - 19 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-54252 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tang, Chi-Long A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Kalus, Sabine A1 - Erdmann, Kerstin T1 - Chemical characterization of ultrafine particles released from 3D printers N2 - Previous studies have shown that desktop 3D printers (Fused Filament Fabrication) emit high numbers of particulate matter, mainly as ultrafine particles (UFP, particle diameter less than 100 nm). However, the chemical composition of emitted particles has been less extensively investigated. In this study, we therefore focused on the chemical composition of particles emitted from 3D printing. The measurements were conducted in a 1 m³ emission test chamber. Emitted particles were sampled by a 13-stage low-pressure cascade impactor onto aluminum foils and then analyzed by TD-GC/MS to identify their organic compounds. Nine commercial filaments made from basic polymers such as Acrylonitrile Butadiene Styrene (ABS), Acrylonitrile Styrene Acrylate (ASA), Polycarbonate (PC), Poly(methyl methacrylate) (PMMA), Nylon, High Performance Polystyrene (HIPS) and a copper-filled Polylactide (PLA) were investigated. The results show that the organic components of the particles are primarily plastic additives such as plasticizer, antioxidant agents, lubricants, UV-absorbers and UV-stabilizers from the filaments. T2 - 17th International Conference Healthy Buildings Europe 2021 CY - Online Meeting DA - 21.06.2021 KW - Chemical characterization KW - FFF-3D-Printer KW - UFP KW - Chamber measurement PY - 2021 SP - 251 EP - 252 AN - OPUS4-54255 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Analysis of air pollutants in ambient and indoor aerosolsby TXRF - application examples N2 - Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). Within the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling was combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution of only a few hours and with good size resolution in the PM10 range. A proof of principles of this methodological approach and the comparison to standard methods within the scope of a field campaign will be presented. Secondly, aerosol sampling and TXRF analysis seems suitable for the quantification of elements in indoor aerosols as well and may provide an important enhancement of existing methods for the analysis of organic species in aerosols (such as sampling and TD-GC/MS). As an example, the TXRF analysis of particles emitted from laser printers under controlled conditions in an environmental test chamber will be presented. T2 - TXRF Journal ClubB CY - Online meeeting DA - 24.02.2022 KW - Aerosol KW - TXRF KW - Cascade impactor KW - ICP-MS KW - Particles KW - Air quality monitoring KW - Element mass concentration PY - 2022 AN - OPUS4-54418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Erdmann, Kerstin A1 - Rasch, Fabian T1 - Chemical characterization of ultra-fine particles released from laser printers N2 - 11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers. T2 - Indoor Air Conference 2022 CY - Kuopio, Finland DA - 12.06.2022 KW - UFP KW - Thermal extraction KW - Cascade impactor PY - 2022 SP - 1 EP - 4 AN - OPUS4-55106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Herbig, B. A1 - Jörres, R. A. A1 - Schierl, R. A1 - Simon, M. A1 - Langner, Jeanette A1 - Seeger, Stefan A1 - Nowak, D. A1 - Karrasch, S. T1 - Psychological and cognitive effects of laser printer emissions: A controlled exposure study N2 - The possible impact of ultrafine particles from laser printers on human health is controversially discussed although there are persons reporting substantial symptoms in relation to these emissions. A randomized, single-blinded, cross-over experimental design with two exposure conditions (high-level and low-level exposure) was conducted with 23 healthy subjects, 14 subjects with mild asthma, and 15 persons reporting symptoms associated with laser printer emissions. To separate physiological and psychological effects, a secondary physiologically based categorization of susceptibility to particle effects was used. In line with results from physiological and biochemical assessments, we found no coherent, differential, or clinically relevant effects of different exposure conditions on subjective complaints and cognitive performance in terms of attention, short-term memory, and psychomotor performance. However, results regarding the psychological characteristics of participants and their situational perception confirm differences between the participants groups: Subjects reporting symptoms associated with laser printer emissions showed a higher psychological susceptibility for adverse reactions in line with previous results on persons with multiple chemical sensitivity or idiopathic environmental intolerance. In conclusion, acute psychological and cognitive effects of laser printer emissions were small and could be attributed only to different participant groups but not to differences in exposure conditions in terms of particle number concentrations. KW - Cognitive performance KW - Exposure KW - Idiopathic environmental intolerance KW - Laser printer emission KW - Multiple chemical sensitivity KW - Subjective complaints PY - 2018 DO - https://doi.org/10.1111/ina.12429 SN - 1600-0668 SN - 0905-6947 VL - 28 IS - 1 SP - 112 EP - 124 PB - John Wiley & Sons, Inc. CY - 111 RIVER ST, HOBOKEN 07030-5774, NJ USA AN - OPUS4-43945 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Brödner, Doris A1 - Jacobi, T. A1 - Rasch, Fabian A1 - Rothhardt, Monika A1 - Wilke, Olaf T1 - Emissions of fine and ultrafine particles and volatile organic compounds from different filament materials operated on a low-cost 3D printer T1 - Emissionen feiner und ultrafeiner Partikel sowie flüchtiger organischer Verbindungen beim Einsatz verschiedener Filamentmaterialien in einem „low-cost“-3D-Drucker N2 - 3D-printing or additive manufacturing has many promising and unique advantages. Especially low cost molten polymer Deposition Printers are increasingly populär in the private and educational sector. Their environmental friendliness can be questioned due to recently reported ultrafine particle and suspected VOC emissions, To further investigate 3D-printing as a potential indoor air pollution source we characterized fine and ultrafine particle emissions from a molten polymer deposition printer producing a 3D object with ten marketable polymer filament materials under controlled conditions in a test chamber. VOC emissions from the filaments have also been compared. Using a straightforward emission model time dependent and averaged particle emission rates were determined. The results indicate that under comparable conditions some filament materials produce mainly ultrafine particles up to an average rate of 1013 per minute. This value is in the upper ränge of typical indoor ultrafine particle sources (e.g. Smoking, frying, candle light, laser printer). The observed material-specific rates differ by five Orders of magnitude. Filament-specific gaseous emissions of organic compounds such as bisphenol A, styrene and others were also detected. Our results suggest a detailed evaluation of related risks and considering protective measures such as housing and filtering. N2 - 3D-Druck oder additive Herstellungsverfahren haben eine Menge vielversprechender und einzigartiger Vorteile. Insbesondere günstige 3D-Drucker für Polymere werden im privaten und ausbildenden Bereich zunehmend beliebter. Ihre Umweltfreundlichkeit kann aufgrund jüngst berichteter Emissionen ultrafeiner Partikel und vermuteter VOC-Emissionen infrage gestellt werden. Um 3D-Drucker für Polymere als mögliche Quelle von Innenraumluftverunreinigungen weiter zu untersuchen, charakterisierten wir die Emissionen feiner und ultrafeiner Partikel bei der Herstellung eines 3D-Objekts unter Verwendung zehn marktgängiger Polymerfilamente unter kontrollierten Bedingungen in einer Emissionsprüfkammer. Die VOC-Emissionen der verschiedenen Filamente wurden ebenfalls verglichen. Die zeitabhängigen und gemittelten Partikelemissionsraten wurden durch Anwendung eines einfachen Emissionsmodells bestimmt. Die Ergebnisse zeigen, dass unter vergleichbaren Bedingungen einige Filamente mit einer mittleren Rate von 10 KW - Emission KW - Ultrafine particles KW - VOC KW - 3D printer PY - 2018 SN - 0949-8036 SN - 0039-0771 VL - 78 IS - 3 SP - 79 EP - 87 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-44954 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan T1 - New VOC compounds in the indoor environment from thermoplastic filaments for 3D printing N2 - A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A )arge number of unexpected compounds were detected that might affect the user's health and have an impact on indoor air chemistry. T2 - HB 2015 - 1st North American regional conference Healthy Buildings 2015 America CY - Boulder, Colorado, USA DA - 17.09.2015 KW - VOC KW - Emission KW - 3D printer PY - 2015 SP - 281 EP - 282 AN - OPUS4-34941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Österle, Werner A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Fink, C. A1 - Giese, A. A1 - Prietzel, Claudia A1 - Seeger, Stefan A1 - Walter, J. T1 - Examination of airborne brake dust T2 - JEF 2010 - 6th European conference on braking CY - Lille, France DA - 2010-11-24 KW - Brake dust KW - Nanoparticles KW - Size-distribution PY - 2010 SP - 1 EP - 6(?) AN - OPUS4-22655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Seeger, Stefan A1 - Kurth, Lutz T1 - Towards the reaction products of indoor fireworks T2 - 11th International symposium on fireworks CY - Puerto Vallarta, México DA - 2009-04-20 KW - Reaction products KW - Particles KW - Smoke gases KW - FTIR PY - 2009 SN - 978-0-9734123-8-3 SP - 66 EP - 79 AN - OPUS4-19384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Österle, Werner A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Prietzel, Claudia A1 - Seeger, Stefan A1 - Fink, C. A1 - Giese, A. A1 - Walter, J. T1 - Surface film formation and dust generation during brake performance tests T2 - Braking 2009 CY - York, UK DA - 2009-06-09 KW - Bremse KW - Dritter Körper KW - Verschleiß KW - Reibung KW - Nanocharakterisierung KW - Aerosol PY - 2009 SN - 978-1-84334-559-6 IS - C672/028/09 SP - 29 EP - 38 PB - Woodhead Publishing Ltd AN - OPUS4-19574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mitropetros, Constantinos A1 - Fomine, Pavel A1 - Seeger, Hansjörg A1 - Bender, Josef A1 - Seifert, Stefan A1 - Steinbach, J. A1 - Plewinsky, B. A1 - Hieronymus, Hartmut T1 - Detonation Wave Impact on the Surface of a Chemically Active Organic Bubbly Liquid T2 - Plasma Physics and Short Time Scale Physics Spring Meeting CY - Aachen, Germany DA - 2003-03-24 PY - 2003 SN - 0420-0195 SN - 0372-5448 SN - 0343-9216 VL - 38-4 IS - K 5.8 SP - 22 CY - Bad Honnef AN - OPUS4-2742 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mitropetros, Constantinos A1 - Fomine, Pavel A1 - Seeger, Hansjörg A1 - Bender, Josef A1 - Seifert, Stefan A1 - Steinbach, J. A1 - Plewinsky, B. A1 - Hieronymus, Hartmut T1 - Shock induced bubble explosion in a monodispersed organic liquid T2 - Plasma Physics and Short Time Scale Physics Spring Meeting CY - Aachen, Germany DA - 2003-03-24 PY - 2003 SN - 0420-0195 SN - 0372-5448 SN - 0343-9216 VL - 38-4 IS - K 5.9 SP - 22 CY - Bad Honnef AN - OPUS4-2743 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mitropetros, Constantinos A1 - Fomine, Pavel A1 - Seeger, Hansjörg A1 - Bender, Josef A1 - Seifert, Stefan A1 - Steinbach, J. A1 - Plewinsky, B. A1 - Hieronymus, Hartmut T1 - Cavitation after shock wave propagation inside a chemically active organic bubbly liquid T2 - Plasma Physics and Short Time Scale Physics Spring Meeting CY - Aachen, Germany DA - 2003-03-24 PY - 2003 SN - 0420-0195 SN - 0372-5448 SN - 0343-9216 VL - 38-4 IS - K 5.10 SP - 22 CY - Bad Honnef AN - OPUS4-2744 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Werner A1 - Seeger, Stefan A1 - Thies, Martina A1 - Gerloff, Constantin ED - Floss, R. T1 - Long-Term Shear Strength of Multilayer Geosynthetics T2 - 3rd European Geosynthetics Conference "EuroGeo 3" - Geotechnical Engineering with Geosynthetics CY - Munich, Germany DA - 2004-03-01 PY - 2004 SN - 3-00-013305-4 VL - II SP - 429 EP - 434 PB - Deutsche Gesellschaft für Geotechnik CY - München AN - OPUS4-3326 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Ling term tensile testing of polyolefin fibers in geotextiles T2 - Workshop Creep and Durability, Seventh International Conference on Geosynthetic - 7 ICG, International Geosynthetic Society CY - Nice, France DA - 2002-09-22 PY - 2002 AN - OPUS4-6004 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Lüders, Günter A1 - Seeger, Stefan ED - Holzlöhner, U. ED - August, H. ED - Meggyes, T. T1 - Geotextile protective layer systems for geomembranes PY - 1997 SN - 0-7277-2590-4 SP - 77 EP - 83 PB - Thomas Telford Publishing CY - London AN - OPUS4-7577 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Long term waste containment - A challenge to geotextiles and geomembranes made of plastic materials T2 - International Symposium On Advanced Materials For Functional Manifestation of Frontier And Environmental Consciousness CY - Tokyo, Japan DA - 1997-09-01 PY - 1997 SP - 1(?) EP - 8(?) AN - OPUS4-7581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Seeger, Stefan T1 - Granta CES Web Software Helps Promote Natural Fibre Eco-Materials N2 - Dr. Stefan Seeger of the German Federal Institute for Materials Research and Testing (Bundesanstalt für Materialforschung und -prüfung - BAM) tells of his successful experience using Granta's CES software to make an eco-materials knowledge resource for automotive, construction, and other industries in the Berlin region. T2 - Abfallwirtschaft für Wien CY - Wien, Österreich DA - 2004-06-24 PY - 2005 SP - 1 EP - 2 PB - Granta CY - Cambridge AN - OPUS4-7582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Holzlöhner, Ulrich A1 - Meggyes, Tamás A1 - Seeger, Stefan T1 - Landfill Technology in Germany PY - 1999 SN - 0967-0513 VL - 7 IS - 2 SP - 14 pages PB - EPP Publ. CY - Richmond AN - OPUS4-7585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Müller, Werner ED - de Groot, M. T1 - Limits of stress and strain: Design criteria for protective layers for geomembranes in landfill liner systems T2 - 1st European Geosynthetics Conference (EUROGEO 1) CY - Maastricht, The Netherlands DA - 1996-09-30 PY - 1996 SN - 90-5410-836-3 SP - 153 EP - 157 PB - Balkema CY - Rotterdam AN - OPUS4-7575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Müller, Wolfgang ED - Dixon, N. T1 - Theoretical approach to designing protection - Selecting a geomembrane strain criterion T2 - 1st IGS UK Chapter National Geosynthetics Symposium CY - Nottingham, England, UK DA - 2003-06-17 PY - 2003 SN - 0-7277-3234-X SP - 137 EP - 151 PB - Telford CY - London AN - OPUS4-2564 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Theoretical Approach to Designing Protection: Selecting a Geomembrane Strain Criterion Geosynthetics: Protecting the Environment T2 - 1st IGS UK Chapter National Geosynthetics Symposium CY - Nottingham, England DA - 2003-06-17 PY - 2003 AN - OPUS4-5409 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - A new measurement method to evaluate length related properties of natural fibres T2 - International Congress on Particle Technology, PARTEC 2007 CY - Nuremberg, Germany DA - 2007-03-27 PY - 2007 AN - OPUS4-15024 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan A1 - Gusovius, H.-J. A1 - Wallot, G. ED - Peukert, W. ED - Schreglmann, C. T1 - A new measurement method to evaluate length related properties of natural bast fibres T2 - PARTEC 2007 - International Congress on Particle Technology CY - Nuremberg, Germany DA - 2007-03-27 KW - Bast fibres KW - Natural fibres KW - Fibre length distribution KW - Image analysis PY - 2007 SP - 1 EP - 4 PB - Nürnberg Messe CY - Nürnberg AN - OPUS4-16099 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Jakob, Ines A1 - Seeger, Stefan A1 - Tatzky-Gerth, Renate T1 - Long-term shear strength of geosynthetic clay liners N2 - Geosynthetic clay liners (GCLs) often have a sandwich-like multilayer structure, e.g. bentonite encased between two geotextile layers connected by fibers or yarns, either by needle-punching or stitch-bonding. Therefore, the internal shear strength of the GCL depends on the strength of reinforcing fiber bundles or yarns and their anchoring strength in the cover and carrier geotextiles. When used on long and steep slopes and covered with thick soil layers, the GCL is permanently exposed to a combined action of compressive and shear stress. Such load conditions are characteristic for landfill covers and the slope stability of the overall cover system in the long run strongly depends on the long-term internal shear strength of the GCL. A new test method was developed to study this long-term shear behavior. The focus was not only on creep, as it is normally done, but on aging effects. The shear test devices allow the measurement of creep curves and times-to-failure at elevated temperatures in different media (tap water and de-ionized water). In this publication, the main findings of the experiments on needle-punched GCLs with and without thermal treatment are summarized. Tap water as a test medium was essential to ensure sodium to calcium ion exchange in the bentonite layer. Under this condition extremely long test durations without failure were achieved. Sliding failure occurred when de-ionized water was used. Two failure modes were observed: brittle failure of the GCLs with thermal treatment and slow disentanglement of fiber bundles for untreated GCLs. Short-term shear strength (e.g. peel strength) is unrelated to the actual long-term shear strength, i.e. to the times-to-failure achieved in long-term shear strength test. Hence, short-term shear strength alone will not provide reliable dimensioning data for product design and choice of resins. Therefore, the often suggested approach, namely, restriction to short-term tests only and application of factors of safety, is challenged by these results. KW - Geosynthetic clay liner KW - Shear strength KW - Oxidative resistance KW - Test methods KW - Long-term testing PY - 2008 DO - https://doi.org/10.1016/j.geotexmem.2007.08.001 SN - 0266-1144 VL - 26 IS - 2 SP - 130 EP - 144 PB - Elsevier CY - Amsterdam AN - OPUS4-16710 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Steinborn, Gabriele A1 - Krietsch, Arne A1 - Langner, Jeanette A1 - Schmidt, Martin A1 - Österle, Werner A1 - Seeger, Stefan T1 - Physical-chemical characterization of NM105(P25) N2 - NM 105, Ti02 (P25) could not be ignited as dust layer and dispersed in air as dust/air-mixture as well. This dust is not dust explosible and the burning behaviour corresponds to Burning Class 1 (no Ignition). The results have shown that the tested sample is thus not combustible at all, because it is already oxidized completely. KW - OECD KW - WPMN KW - TiO2 KW - NM105 KW - P25 KW - Sponsorship programme PY - 2012 SP - 1 EP - 18 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-27322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Measurement of fine and ultrafine particles from office devices during printing in order to develop a test method for the Blue Angel ecolabel for office-based printing devices N2 - The research project on which this report is based focuses on the measurement of particulate emissions in the area of fine and ultrafine particles from laser printing devices. Against the backdrop of a public debate about possible hazards related to these emissions, ⁠UBA⁠ has commissioned BAM to develop a measurement method for these emissions, to expand the existing awarding criteria for the "Blue Angel" ecolabel by the aspect of particle emissions and to physically and chemically analyse particulate emissions. The resulting awarding criteria will be submitted to RAL later this year. ⁠Emission⁠ characteristics of laser printing devices, conclusions on awarding criteria and interim results of the project were discussed in three sessions of a project-related expert group. KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/measurement-of-fine-ultrafine-particles-from-office SN - 1862-4804 VL - 75 IS - UBA-FBNr: 001743/E / FKZ: 3708 95 301 SP - 1-142, Suppl.RAL-UZ-122 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Barthel, Mathias A1 - Pedan, Vasilisa A1 - Hahn, Oliver A1 - Rothhardt, Monika A1 - Bresch, Harald A1 - Jann, Oliver A1 - Seeger, Stefan T1 - XRF-Analysis of fine and ultrafine particles emitted from laser printing devices N2 - In this work, the elemental composition of fine and ultrafine particles emitted by ten different laser printing devices (LPD) is examined. The particle number concentration time series was measured as well as the particle size distributions. In parallel, emitted particles were size-selectively sampled with a cascade impactor and subsequently analyzed by the means of XRF. In order to identify potential sources for the aerosol's elemental composition, materials involved in the printing process such as toner, paper, and structural components of the printer were also analyzed. While the majority of particle emissions from laser printers are known to consist of recondensated semi volatile organic compounds, elemental analysis identifies Si, S, Cl, Ca, Ti, Cr, and Fe as well as traces of Ni and Zn in different size fractions of the aerosols. These elements can mainly be assigned to contributions from toner and paper. The detection of elements that are likely to be present in inorganic compounds is in good agreement with the measurement of nonvolatile particles. Quantitative measurements of solid particles at 400 °C resulted in residues of 1.6 × 109 and 1.5 × 1010 particles per print job, representing fractions of 0.2% and 1.9% of the total number of emitted particles at room temperature. In combination with the XRF results it is concluded that solid inorganic particles contribute to LPD emissions in measurable quantities. Furthermore, for the first time Br was detected in significant concentrations in the aerosol emitted from two LPD. The analysis of several possible sources identified the plastic housings of the fuser units as main sources due to substantial Br concentrations related to brominated flame retardants. KW - Particulate emissions KW - UFP KW - FP KW - Laser printers KW - XRF PY - 2011 DO - https://doi.org/10.1021/es201590q SN - 0013-936X SN - 1520-5851 VL - 45 IS - 18 SP - 7819 EP - 7825 PB - ACS Publ. CY - Washington, DC AN - OPUS4-24393 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Traub, Heike A1 - Bresch, Harald A1 - Seeger, Stefan A1 - Recknagel, Sebastian A1 - Kipphardt, Heinrich T1 - Effort on calibration of infrared spark ablation of copper with synthetic copper standards N2 - Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored. KW - Calibration KW - Spark ablation KW - Synthetic standard KW - Particle size distribution KW - Fractionation KW - Laser ablation KW - ICP-MS PY - 2011 DO - https://doi.org/10.1016/j.sab.2011.04.005 SN - 0584-8547 SN - 0038-6987 VL - 66 IS - 6 SP - 432 EP - 438 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24065 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan A1 - Böhm, Hans A1 - Söhring, Guido A1 - Müller, Werner ED - Cancelli, A. T1 - Long term testing of geomembranes and geotextiles under shear stress T2 - 2nd European Geosynthetics Conference ; 2nd EuroGeo 2000 CY - Bologna, Italy DA - 2000-10-15 KW - Geomembranes KW - Geotextiles PY - 2000 SN - 88-555-2560-3 VL - 2 SP - 607 EP - 612 PB - Pàtron CY - Bologna AN - OPUS4-854 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tang, Chi-Long A1 - Seeger, Stefan T1 - Measurement of sub-4 nm particle emission from FFF-3D printing with the TSI Nano Enhancer and the Airmodus Particle Size Magnifier N2 - The emission of ultrafine particles from small desktop Fused Filament Fabrication (FFF) 3D printers has been frequently investigated in the past years. However, the vast majority of FFF emission and exposure studies have not considered the possible occurrence of particles below the typical detection limit of Condensation Particle Counters and could have systematically underestimated the total particle emission as well as the related exposure risks. Therefore, we comparatively measured particle number concentrations and size distributions of sub-4 nm particles with two commercially available diethylene glycol-based instruments – the TSI 3757 Nano Enhancer and the Airmodus A10 Particle Size Magnifier. Both instruments were evaluated for their suitability of measuring FFF-3D printing emissions in the sub-4 nm size range while operated as a particle counter or as a particle size spectrometer. For particle counting, both instruments match best when the Airmodus system was adjusted to a cut-off of 1.5 nm. For size spectroscopy, both instruments show limitations due to either the fast dynamics or rather low levels of particle emissions from FFF-3D printing in this range. The effects are discussed in detail in this article. The findings could be used to implement sub-4 nm particle measurement in future emission or exposure studies, but also for the development of standard test protocols for FFF-3D printing emissions. KW - Air pollution KW - Ultrafine particles KW - Sub-4nm particles KW - FFF-3D printing KW - Emission testing PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-595952 DO - https://doi.org/10.1080/02786826.2024.2320430 SN - 0278-6826 VL - 58 IS - 6 SP - 644 EP - 656 PB - Taylor & Francis CY - London AN - OPUS4-59595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tang, Chi-Long A1 - Seeger, Stefan A1 - Röllig, Mathias T1 - Improving the comparability of FFF-3D printing emission data by adjustment of the set extruder temperature N2 - Fused filament fabrication (FFF) is a material extrusion-based technique often used in desktop 3D printers. Polymeric filaments are melted and are extruded through a heated nozzle to form a 3D object in layers. The extruder temperature is therefore a key parameter for a successful print job but also one of the main emission driving factors as harmful pollutants (e.g., ultrafine particles) are formed by thermal polymer degradation. The awareness of potential health risks has increased the number of emission studies in the past years. However, studies usually refer their calculated emission data to the printer set extruder temperature for comparison purposes. In this study, we used a thermocouple and an infrared camera to measure the actual extruder temperature and found significant temperature deviations to the displayed set temperature among printer models. Our result shows that printing the same filament feedstocks with three different printer models and with identical printer set temperature resulted in a variation in particle emission of around two orders of magnitude. A temperature adjustment has reduced the variation to approx. one order of magnitude. Thus, it is necessary to refer the measured emission data to the actual extruder temperature as it poses a more accurate comparison parameter for evaluation of the indoor air quality in user scenarios or for health risk assessments. KW - Ultrafine particles KW - Infrared thermography KW - Thermocouple KW - Indoor air quality KW - FFF-3D printer PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-572842 DO - https://doi.org/10.1016/j.aeaoa.2023.100217 VL - 18 SP - 100217 PB - Elsevier Ltd. CY - Amsterdam, Niederlande AN - OPUS4-57284 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Kurth, Lutz A1 - Seeger, Stefan A1 - Barthel, Mathias A1 - Panne, Ulrich T1 - Aerosol emissions from outdoor firework displays N2 - The results of investigations on the emission of particulate matter from three outdoor firework displays are presented. During these events, possibly harmful and toxic aerosol emissions were measured. Aerosols in the size range from 30 to 450 nm were detected. The maxima in the observed particle size distribution were between 80 and 175 nm, and the highest value determined was ~1.3 · 106 particles per cm³, while the highest mass concentration was approximately 1.8 mg m–3. The time-averaged particle mass concentration did, however, not exceed 0.7 mg m–3 (over 15 min). KW - Firework display KW - Particle size range KW - Particulate matter KW - Threshold values PY - 2011 DO - https://doi.org/10.1002/ceat.201100080 SN - 0930-7516 SN - 1521-4125 VL - 34 IS - 12 SP - 2044 EP - 2050 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-24929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Dutschke, Andreas A1 - Lohrer, Christian A1 - Seeger, Stefan A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Kaiser, Michael A1 - Stattaus, Kim A1 - Panne, Ulrich T1 - Determination of reaction products during a large firework display in Germany T2 - 11th International symposium on fireworks CY - Puerto Vallarta, México DA - 2009-04-20 KW - Firework display KW - Reaction products KW - Particles KW - Sound pressure PY - 2009 SN - 978-0-9734123-8-3 SP - 50 EP - 63 AN - OPUS4-19383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dutschke, Andreas A1 - Seeger, Stefan A1 - Kurth, Lutz A1 - Panne, Ulrich A1 - Lohrer, Christian T1 - Emissions of reaction products and sound from outdoor and indoor firework displays N2 - This work presents results of investigations towards the emission of chemical reaction products and sound pressure during an outdoor and an indoor firework display. Potentially harmful and toxic gases, and aerosols, were measured as well as sound pressures. Aerosols were measured with a Differential Mobility Analyzer (DMA) as well as a Laser Particle Counter. The focus was on particles with diameters between 11 nm and 20 µm. A transportable Fourier Transform Infrared (FTIR) spectroscopy detector registered the concentrations of emitted reaction gases, simultaneously. During the outdoor firework display, peak particle concentrations of >550000 particles cm-3, equivalent to a mass concentration of approximately 3.95 mg m-3, were detected, revealing a concentration maximum at approximately 175 nm particle diameter. The time-averaged particle mass concentration did not exceed 1.58 mg m-3 over 15 minutes. Due to the large distances (110 m) to the firing points, no significant harmful or toxic gas concentrations were measured during the entire firework display. In contrast, concentrations of sulphur dioxide (SO2) rose after an indoor firework display in a large event hall. On two days, more than 23000 particles cm-3 (which equates to a mass concentration of approximately 0.41 mg m-3) were detected when the hall ventilation was turned off, and more than 11000 particles cm-3 (which equates to a mass concentration of approximately 1.18 mg m-3) when the hall ventilation was activated. Concentration maxima appeared at approximately 300 nm particle diameter. The time-averaged particle concentrations in this case did not exceed 0.56 mg m-3 (over 15 minutes). KW - Pyrotechnic articles KW - Aerosols KW - Combustion gases PY - 2009 SN - 1082-3999 IS - 28 SP - 78 EP - 93 CY - Whitewater, Colo. AN - OPUS4-20796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Wilke, Olaf A1 - Bücker, Michael A1 - Jann, Oliver T1 - Time- and Size-Resolved Characterization of Particle Emissions from Office Machines with Printing Function T2 - Healthy Buildings 2006 CY - Lisboa, Portugal DA - 2006-06-04 KW - Hard copy devices KW - Laserprinters KW - Toner KW - Particle emissions KW - Particles KW - Aerosols PY - 2006 SN - 978-989-95067-1-8 VL - 2 SP - 447 EP - 450 CY - Lissabon AN - OPUS4-14522 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Müller, Werner T1 - Requirements and Testing of Protective Layer Systems for Geomembranes N2 - Geomembranes used in basal liner systems of landfills must not be damaged by the coarse gravel of the standard drainage layer. Therefore, the geomembrane must be protected against mechanical damage and strain by means of a suitable protective layer. The main requirements for this protective layer as well as the long-term durability of the mineral and geotextile components are compiled in the guideline recently released by German authorities. An overview is given on the existing types of protective layer systems with the state-of-the-art testing, the requirements and selected results of related research programs. PY - 1996 SN - 0266-1144 VL - 14 IS - 7-8 SP - 365 EP - 376 PB - Elsevier CY - Amsterdam AN - OPUS4-7583 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan A1 - Müller, Werner T1 - Requirements and testing of protective layer systems for geomembranes T2 - 9th GRI Conference, Geosynthetics in Infrastructure - Enhancement and Remediation CY - Philadelphia, PA, USA DA - 1995-12-12 PY - 1995 SP - 175 EP - 184 CY - Philadelphia AN - OPUS4-7578 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Thies, Martina A1 - Gerloff, Constantin A1 - Müller, Werner A1 - Seeger, Stefan ED - Koerner, R. ED - Gartung, E. ED - Zanzinger, H. T1 - Long-term shear testing of geosynthetic clay liners T2 - International Symposium [on Clay Geosynthetic Barriers] IS CY - Nuremberg, Germany DA - 2002-04-16 PY - 2002 SN - 90-5809-380-8 SP - 97 EP - 104 PB - Balkema CY - Lisse AN - OPUS4-1362 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Seeger, Stefan A1 - Müller, Werner A1 - Mohr, Kerstin ED - Delmas, P. T1 - Long term tensile testing of polyolefin fibers in geotextiles T2 - 7th International Conference on Geosynthetics (ICG) CY - Nice, France DA - 2002-09-22 PY - 2002 SN - 90-5809-529-0 VL - 4 SP - 1459 EP - 1462 PB - Balkema CY - Lisse AN - OPUS4-1532 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Werner A1 - Seeger, Stefan T1 - Requirements for Leak Monitoring Systems for HDPE Geomembrane Landfill Liners KW - Electric leak monitoring system KW - Landfill lining KW - HDPE geomembrane KW - Leaks and holes PY - 2002 DO - https://doi.org/10.2462/09670513.610 SN - 0967-0513 VL - 10 IS - 2 SP - 91 EP - 99 PB - EPP Publ. CY - Richmond AN - OPUS4-1473 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan A1 - Barthel, Mathias T1 - Particle emission from laser printing devices - Analysis and problem treatment within the German Blue Angel ecolabel for office machines N2 - There is a continuous public debate on possible adverse health effects of particle emissions from laser printing devices (LPD). LPD do not emit toner particles, which have diameters > 1 μm, but particles in the size range below 300 nm. The German Federal Environment Agency (UBA) initiated the further development of an existing emission test scheme for awarding the Blue Angel ecolabel to LPD. The proposed new test scheme includes the quantification of emitted particles by number and the quantitative comparison of LPD emissions. Size resolved aerosol sampling and chemical analysis by combination of XRF and TDGC/ MS identified organic and inorganic substances which could be attributed to sources such as paper, LPD plastic parts and toner components. The results show that particle emissions from LPD do not have a monocausal explanation. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.012 KW - Ultrafine particle sources KW - Ultrafine particle emission KW - Health effects KW - Product safety KW - Standards PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 6 (4F.1) AN - OPUS4-27524 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hilgenberg, Kai A1 - Daum, Werner A1 - Maierhofer, Christiane A1 - Altenburg, Simon A1 - Bruno, Giovanni A1 - Heckel, Thomas A1 - Skrotzki, Birgit A1 - Zerbst, Uwe A1 - Kranzmann, Axel A1 - Bettge, Dirk A1 - Sommer, Konstantin A1 - Seeger, Stefan A1 - Nitsche, Michael A1 - Günster, Jens A1 - Evans, Alexander T1 - Additive manufacturing at the BAM: We focus on Safety N2 - In Germany, the Federal Institute for Materials Research and Testing (BAM) is addressing challenges in the implementation of additive manufacturing on the industrial landscape for safety-critical applications. KW - Process development KW - Additive Manufacturing KW - In-situ Process Monitoring KW - Non-destructive Materials KW - Characterisation KW - Safety KW - Fatigue KW - Environment KW - Standardisation PY - 2019 UR - https://static.asminternational.org/amp/201910/22/ SN - 0882-7958 VL - 177 IS - 7 SP - 22 EP - 26 PB - ASM International CY - Materials Park, OH, USA AN - OPUS4-49780 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Beck, Oliver A1 - Wilke, Olaf A1 - Pyza, Lars A1 - Seeger, Stefan T1 - Test procedure for the evaluation of adsorptive building materials N2 - Construction materials working on the basis of physisorption or chemisorptions are considered as an additional means to improve indoor air quality. Some manufacturers promise a complete demineralisation of VOCs into C02 and water being not possible for most of typical indoor air pollutants. On the contrary, sometimes new substances are generated due to surface reactions, e.g. formaldehyde (Salthammer and Fuhrmann, 2007). For evaluating such products a testing system was built up at BAM enabling testing under defined, reproducible and realistic conditions. Tue VOC test gas is provided by a gas mixing system (GMS) developed at our institute (Richter, 2010). VOC gas mixtures with retraceable concentrations between 1 µg m·3 up to 1.5 mg m·3 can be produced. A gypsum board promoted as an 'air cleaner' was put in a 1 m3 emission test chamber connected with the GMS. The board was exposed to a gas mixture of four VOCs - ethyl acetate, hexanal, (+)-a-pinene and R-(+)-limonene - with gas concentrations between 600 µg m·3 and 1,440 µg m·3 for a period of 14 days. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Air cleaning KW - Sorptive construction materials KW - Test procedure KW - Volatile organic compound KW - Test gas generation KW - Healthy homes and buildings KW - Material and construction KW - Product safety KW - Risk assessment PY - 2012 SN - 978-1-921897-40-5 SP - 43 EP - 44 (Session 4B) AN - OPUS4-27558 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mohr, Gunther A1 - Seeger, Stefan A1 - Hilgenberg, Kai T1 - Measurement of particle emissions in Laser Powder Bed Fusion (L-PBF) processes and its potential for in-situ process monitoring N2 - Laser Powder Bed Fusion (L-PBF) is a promising additive manufacturing (AM) technology for metal part production especially for complex and lightweight structures or functional designs. In L PBF processes several by-products including welding plume and its condensates, spatter and ejected powder are generated during laser exposure. Investigations of micro- and nano-sized by-products have received little attention in literature. This study focuses on the analysis of particle emissions in L PBF of 316L stainless steel using a scattered light aerosol spectrometer and a fast mobility particle sizer spectrometer during the process which allows for in-situ analysis of particle sizes in the range of 6 nm to 100 µm. A distinct correlation of emission signals to part position can be revealed. In addition, a significant influence of laser scanning vector directions on emission signals is presented. Furthermore, differing powder layer thicknesses can be recognised by deviations in emission signals. T2 - Euro PM 2019 CY - Maastricht, The Netherlands DA - 13.10.2019 KW - Plume KW - Laser Powder Bed Fusion (L-PBF) KW - Additive Manufacturing (AM) KW - Spatter KW - Fume KW - Particle gas emission KW - Aerosol measurements PY - 2019 SP - 1 EP - 7 AN - OPUS4-49388 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - VOC, Fine and Ultrafine Particles Emissions from Additive Manufacturing and 3D-Printers N2 - The presentation gives an overview on Additive Manufacturing techniques and related potential risks from emission of hazardous gases and aerosols, based on emission characterizations in BAM. Voluntary mitigation strategies are presented T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - 3D Printing KW - Additive Manufacturing KW - Particulate emissions KW - Emissions of hazardous gases KW - Filament comparison PY - 2019 AN - OPUS4-47812 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - UBA Projects on Particulate Emissions from Laser Printers N2 - The presentation gives an overview on past and ongoing projects in BAM on laser printer particulate emissions, funded by the German Environment Agency (UBA) in order to further develop award criteria for the Blue Angel ecolabel for office machines T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - Laser Printer KW - Particulate emission KW - Blue Angel ecolabel KW - Office machines PY - 2019 AN - OPUS4-47811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Regulatory Trends in the EU for Chemicals and Nanomaterials N2 - The presentation gives an overview on existing and upcoming REACH regulations in the EU concerning nanomaterials. T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - Nanomaterials KW - REACH KW - EU regulations PY - 2019 AN - OPUS4-47814 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Overview on the EMPIR Project "AEROMET" N2 - Overview on the ongoing EU EMPIR Project "AEROMET" Aerosol Metrology for Atmospheric Science and Air Quality, Overview on preliminary resuilts in Workpackages 3 "Calibration of MPSS and CPCs" and 4 "Quantifying airborne particle compositions in the field" T2 - Meeting des ISO TC24/SC4, Joint session of Working Groups 9 "Single particle light interaction methods" and 12 "Electrical mobility and number concentration analysis for aerosol particles" CY - Graz, Austria DA - 11.04.2019 KW - Ambient air pollution KW - EU EMPIR KW - Chemical analysis KW - Total reflection X-ray spectroscopy KW - Airborne Particles PY - 2019 AN - OPUS4-47820 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Instruments for Fine and Ultrafine Particle Emission Characterization N2 - An overview on instruments and methods for the measurement and chemical characterization of particulate emissions from local sources is presented T2 - BAM - JBMIA (Japan Business Machine and Information System Industries Association) Meeting, JBMIA Emissions Working Group Meeting CY - Tokyo, Japan DA - 04.05.2019 KW - Aerosol spectroscopy KW - Particulate emission KW - Chemical analysis KW - Total reflection X-ray spectroscopy KW - Calibration PY - 2019 AN - OPUS4-47816 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - AEROMET - Observation of quickly changing element mass concentrations in an ambient aerosol using portable TXRF N2 - Measurements of aerosol particles are vital for enforcing EU air quality regulations to protect human health, and for research on climate change effects. Although metrics such as PM10 and PM2.5 are currently in use, the level of uncertainty of aerosol metrics is too high and the traceability is insufficient. The project AEROMET, which has been started in June 2017 aims at implementing improvements in a) the uncertainty of particle mass, size and number concentration measurements and b) in the characterization of regulated components in airborne particles. Both are demanded by existing networks within the EU as well as by global atmospheric research. On-site measurement campaigns One of the objects is the application of mobile x-ray spectroscopy techniques combined with aerosol sampling techniques for quantifying particle compositions in the field for real time analysis. During two in-field measurement campaigns in Budapest, Hungary in May 2018 and Cassino, Italy in September 2018 the size dependent mass concentrations of specific elements in ambient aerosols were monitored under dynamic conditions. Typically, airborne particles are sampled on filter substrates. During this project new sampling methods with specially designed substrate holders for an in-situ TXRF analysis were developed and applied for the first time. This approach allows a direct time and size resolved analysis without laborious digestion steps and a reduced risk of contamination. Aerosol particles were sampled in a 13-stage DLPI impactor - size range from 0,03 µm to 10 µm - which was equipped with special adapters for acrylic discs of 30 mm diameter, serving as substrates. TXRF analysis was performed on site with the transportable spectrometer S2 PICOFOX (Bruker Nano GmbH) equipped with a Mo X-ray tube and a 30 mm² Silicon Drift Detector (SDD). Excitation conditions were 50 kV, 600 µA, measurement time 1000 s. Quantification was based on internal standardization using 50 ng of Y in solution, which was pipetted into the centre of the discs prior to sampling. At moderate air pollution levels, i.e. PM10 ~ 20 µg/m³, sampling times of less than 2 hours were enough for the detection of elements in different particle size bins. The in-situ approach and the high sensitivity of TXRF enables the observation of rather quick changes in the quantity and distribution of elements in an ambient aerosol on the day of sampling, as the below example from the Cassino field campaign on 11 Sept. 2018 shows: The analysis of the morning and afternoon sampling shifts reveals the occurrence of the elements Fe, Ca and Si in different size bins as well as their significant temporal change in respective mass concentrations over the day while the distributions of several other elements in the aerosol remain unchanged. The validation of these results by backup measurements is planned. T2 - European Aerosol Conference EAC 2019 CY - Gothenburg, Sweden DA - 25.08.2019 KW - TXRF KW - Ambient air KW - Aerosol KW - Cascade impactor KW - Element analysis PY - 2019 AN - OPUS4-49582 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Seeger, Stefan T1 - Quantification of element mass concentrations in aerosols by combination of cascade impactor sampling and in-situ TXRF Spectroscopy N2 - A mobile Bruker S2 Picofox TXRF spectrometer has been used in two field campaigns within the EMPIR env07 AEROMET project for the on-site analysis of cascade impactor aerosol samples.The results show that even at moderate air pollution levels – i.e.PM10 fairly below 20 μg/m³ - element mass concentrations in air in the range of 100 pg/m³could be measured in up to 13 size bins after sampling times of less than only 0.5 days. T2 - UFP 2019 Ultrafeinstaub in der Atmosphäre und in Innenräumen, 3. Symposium CY - Technische Universität Berlin, Germany DA - 19.09.2019 KW - TXRF ambient air aerosol chemical analysis aerosol element composition KW - Aerosol KW - TXRF KW - Cascade impactor KW - Aerosol element alanysis KW - Aerosol element mass concentration PY - 2019 AN - OPUS4-49580 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiedensohler, A. A1 - Wiesner, A. A1 - Weinhold, K. A1 - Birmili, W. A1 - Herrmann, M. A1 - Merkel, M. A1 - Müller, T. A1 - Pfeifer, S. A1 - Schmidt, A. A1 - Tuch, T. A1 - Velarde, F. A1 - Quincey, P. A1 - Seeger, Stefan A1 - Nowak, A. T1 - Mobility particle size spectrometers: Calibration procedures and measurement uncertainties N2 - Mobility particle size spectrometers (MPSS) belong to the essential instruments in aerosol science that determine the particle number size distribution (PNSD)in the submicrometer size range. Following calibration procedures and target uncertainties against standards and reference instruments are suggested for a complete MPSS quality assurance program: a) calibration of the CPC counting efficiency curve (within 5% for the plateau counting efficiency; within 1 nm for the 50% detection efficiency diameter), b) sizing calibration of the MPSS, using a certified polystyrene latex (PSL) particle size standard at 203 nm (within 3%), c) intercomparison of the PNSD of the MPSS (within 10% and 20% of the dN/dlogDP concentration for the particle size range 20 – 200 nm and 200 to 800 nm, respectively), and d) intercomparison of the integral PNC of the MPSS (within 10%). Furthermore, following measurement uncertainties have been investigated: a) PSL particle size standards in the range from 100-500nm match within 1% after sizing calibration at 203 nm. b) Bipolar diffusion chargers based on the radioactive nuclides Kr85, Am241 and Ni63 and a new ionizer based on corona discharge follow the recommended bipolar charge distribution, while soft X-ray-based charges may alter faster than expected. c) The use of a positive high voltage supply show a 10% better performance than a negative one. d) The intercomparison of the integral PNC of an MPSS against the total number concentration is still within the target uncertainty at an ambient pressure of approximately 500 hPa. KW - Measurement uncertainties KW - Mobility particle size spectrometer (MPPS) KW - Condensation particle counter (CPC) KW - Calibration PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-425060 DO - https://doi.org/10.1080/02786826.2017.1387229 SN - 1521-7388 VL - 52 IS - 2 SP - 146 EP - 164 PB - Tailor & Francis CY - USA AN - OPUS4-42506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Roß, Marcel A1 - Severin, Stefanie A1 - Hildebrandt, Jana A1 - Erdmann, Kerstin A1 - Miaskiewicz, Aleksandra A1 - Škorjanc, Viktor A1 - Bernardes de Araujo, Wander Max A1 - Leyden, Matthew A1 - Korte, Lars A1 - Seeger, Stefan A1 - Dallmann, André A1 - Albrecht, Steve T1 - Compositional Analysis of Metal Halide Perovskites: Insight into the Coevaporation Process via Nuclear Magnetic Resonance and X-ray Fluorescence Spectroscopy N2 - Lead halide perovskites have emerged as a highly promising class of materials for solar cells. Nevertheless, suitable procedures to analyze the exact composition of the perovskite films are rare and are not generally applicable. Here we show a simple and fast method to determine the absolute composition of mixed metal halide perovskites through a combination of nuclear magnetic resonance and total reflection X-ray fluorescence spectroscopy. The method is validated on powder mixtures and applied to thin film samples prepared by coevaporation of formamidinium iodide (FAI), CsI, PbI2 and PbBr2, allowing correlation between film composition and solar cell performance. We show that the rates of the individual precursors do not always translate linearly into film composition and that the preparation of the hole transport layer MeO-2PACz strongly influences the incorporation of FAI. Our work highlights the importance of compositional analysis and demonstrates how the developed method provides new insights into the complex coevaporation process in perovskite solar cells. KW - e‑ray Fluorescence Spectroscopy KW - Metal Halide Perovskites KW - CoevaporationP rocess KW - Nuclear Magnetic Resonance PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656932 DO - https://doi.org/10.1021/acsenergylett.5c03689 SN - 2380-8195 VL - 11 IS - 2 SP - 1935 EP - 1943 PB - American Chemical Society (ACS) AN - OPUS4-65693 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -