TY - CONF A1 - Berchtold, Florian A1 - Thöns, Sebastian A1 - Knaust, Christian A1 - Rogge, Andreas T1 - Review of road tunnel risk assessment - common aspects? N2 - Safety measures like tunnel emergency Ventilation Systems cause high financial costs. Hence, safety measures have to be chosen with the focus on the expected reduction of the consequences like fatalities or damage on structures and in conjunction with the investments. Since 2004, the European directive EU 2004/54/EC proposes therefore the application of risk assessments. Because the EU directive provides only few legal requirements on risk assessments, the methodologies developed on this basis have large differences. After one decade of intensive research, the comparative study now highlights common aspects and differences of several methodologies. T2 - 6th International symposium on tunnel safety and security CY - Marseille, France DA - 12.03.2014 KW - Tunnel KW - System KW - Risk assessment KW - Fire KW - Safety KW - Comparative study PY - 2014 SP - 669 EP - 670 AN - OPUS4-31256 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Faber, M.H. A1 - Thöns, Sebastian ED - Miraglia, S. ED - Vrouwenvelder, A.C.W.M. ED - Steenbergen, R.D.J.M. ED - Van Gelder, P.H.A.J.M. T1 - On the value of structural health monitoring T2 - 22nd ESREL conference - Safety, reliability and risk analysis: Beyond the horizon CY - Amsterdam, The Netherlands DA - 2013-09-29 PY - 2014 SN - 978-1-138-00123-7 SP - 2535 EP - 2544 PB - Taylor & Francis AN - OPUS4-29894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hu, Wei-Hua A1 - Thöns, Sebastian A1 - Said, Samir A1 - Rücker, Werner ED - Cunha, A. ED - Caetano, E. ED - Ribeiro, P. ED - Müller, G. T1 - Resonance phenomenon in a wind turbine system under operational conditions N2 - A prototype of wind turbines in 5 megawatt dass was built and tested at the first German offshore wind energy test fteld in the North Sea. In order to investigate dynamic behaviors under a complex state of loads, a continuous dynamic monitoring System was implemented by Federal Institute for Material Research and Testing (BAM). It recorded structural responses and environmental/operational variables from November 2007 to October 2009. This paper presents significant resonance phenomenon due to the interaction in the tower-nacelle System under operational conditions. Modal parameters are automatically estimated by the poly reference Least Square Complex Frequency domain (p-LSCF) method. Campbell plot demonstrates that a three-blade passage frequency and its multiples f3n match with the natural frequencies of the wind turbine System in several modal Orders. The damping estimates decrease and the Vibration amplitude increase significantly. A control System is necessary to minimize the excessive vibrations. T2 - EURODYN 2014 - 9th International conference on structural dynamics CY - Porto, Portugal DA - 30.06.2014 KW - Wind turbine KW - Tower-nacelle system KW - Resonance KW - Continuous dynamic monitoring KW - Automated operational modal analysis PY - 2014 SN - 978-972-752-165-4 SN - 2311-9020 SP - 3619 EP - 3626 AN - OPUS4-32970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -