TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Jegielka, Dennis A1 - Aloysius, Allen A1 - Recknagel, Sebastian T1 - SI-traceable total analysis of nitrate and nitrite by isotope dilution optical spectroscopy and its application to Berlin surface waters N2 - Accurate nitrate and nitrite data support water-quality regulation, yet routine methods rely on external calibration and rarely achieve SI traceability. We report a calibration-free determination of nitrate and nitrite by combining isotope dilution with high-resolution continuum-source graphite furnace molecular absorption spectrometry (ID-HR-CS-GF-MAS). A 15N-enriched nitrate spike (its concentration verified by reverse isotope dilution against the standard reference material NIST 3185) provides the SI link, and it is gravimetrically added to samples; nitrate and residual nitrite are converted in situ to nitric oxide (NO), whose 215 nm band is recorded at a pixel resolution of λ/Δλ ≈ 140 000. The 0.2127 nm shift between 14NO and 15NO electronic spectra is resolved, and a three-latent-variable partial least squares regression model yields the 15N/14N ratio with 0.3% precision. Instrumental LoD values of 4.8 ng (14N) and 3.2 ng (15N) translate to a method LoD of 4.8 ng of nitrogen (equivalent to 1.05 mg L−1 NO3− for a 20 μL aliquot). The furnace program allows for successive drying/pyrolysis loops, so additional 20 μL aliquots can be layered onto the graphite platform. Alternatively, a 10 mL anion-exchange solid-phase extraction step concentrates nitrate and nitrite fivefold, allowing for the analysis of even lower sample concentrations. Results for four certified reference materials (2.9 to 1000 mg L−1 NO3−) agreed with certified values, giving relative expanded uncertainties of 2 to 4%. Analysis of twenty Berlin surface-water samples revealed concentrations ranging from 0.10 to 7.3 mg L−1 NO3−, indicating that the Panke River and Teltow Canal are the primary sources of nitrogen. ID-HR-CS-GF-MAS thus delivers ID-MS-level accuracy in a few minutes per run with bench-top optics, and, with optional on-platform or SPE pre-concentration, extends SI-traceable nitrate/nitrite monitoring into the low-ng regime. KW - Isotope dilution KW - Nitrate and nitrite determination KW - SI-traceable quantification KW - Calibration-free analysis KW - Water quality KW - Berlin surface waters KW - NO molecular absorption bands PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643785 DO - https://doi.org/10.1039/D5JA00252D SN - 0267-9477 VL - 40 IS - 10 SP - 2692 EP - 2701 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Morcillo, Dalia A1 - Oelze, Marcus A1 - Seena Prem, Pranav A1 - de Oliveira Guilherme Buzanich, Ana A1 - Emmerling, Franziska A1 - Recknagel, Sebastian A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Lithium isotope fractionation as an early indicator of degradation mechanisms in lithium-ion batteries N2 - Aging in lithium-ion batteries (LIBs) degrades performance and hinders sustainability, demanding advanced diagnostics for early failure prediction. We investigate lithium isotope fractionation (LIF) as an innovative probe of degradation in lithium cobalt oxide (LCO) coin cells aged over 0−700 cycles. High-precision multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) quantified δ7Li variations across cell stages: non-cycled (0 cycles), newly formed (5 cycles), semi-aged (250 cycles), and fully aged (700 cycles). During early cycling (≤ 45 cycles), chemical processes drive 7Li enrichment at the anode (δ7Li vs LSVEC = +12 ‰) through solid electrolyte interphase (SEI) formation, while the cathode depletes in 7Li (δ7Li vs LSVEC = −0.7 ‰). Beyond 45 cycles, electric field-induced migration predominates, promoting 6Li intercalation into the anode and increasing the δ7Li of the cathode by 8.1 ‰. Mass balance verifies isotope conservation, attributing shifts to redistribution and trapping. Complementary electrochemical impedance spectroscopy (EIS) and X-ray absorption spectroscopy and diffraction confirm SEI expansion, cobalt oxidation, lattice shrinkage, and changes in electrode structure, corroborating LIF trends. Notably, a δ7Li inflection at approximately 270 cycles anticipates end-of-life by 70 cycles, surpassing traditional methods in sensitivity. LIF emerges as a predictive indicator of aging mechanisms, informing optimized designs for durable LIBs. KW - Lithium isotope fractionation KW - Lithium-ion batteries KW - Degradation mechanisms KW - LiCoO2 cathodes KW - LCO KW - Isotopic tracing KW - Lithium isotopes PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650945 DO - https://doi.org/10.26434/chemrxiv-2025-16lvq SP - 1 EP - 19 AN - OPUS4-65094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Battistella, Beatrice A1 - Revill, Adam A1 - Venzago, Cornel A1 - Hoffmann, Volker A1 - Agudo Jácome, Leonardo A1 - Al-Sabbagh, Dominik A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Depth-Resolved Lithium Isotope Fractionation as a Diagnostic of Interphase Evolution and Degradation in Lithium Ion Batteries N2 - Lithium isotopic fractionation is well-established in dynamic geochemical systems; however, its role in lithium-ion batteries (LIBs) remains uninvestigated. Herein, we report the first depth-resolved demonstration that isotopic separation occurs during Li-ion cell operation whose magnitude depends on the cycling history. Using depth-resolved glow discharge mass spectrometry, we monitored the 7Li/6Li ratio in LiNi0.333Mn0.333Co0.333O2 (NMC111)||graphite coin cell electrodes at defined life-cycle stages. Different charging rates were examined to get mechanistic insight into kinetic and thermodynamic control in the fractionation process. Although pristine electrodes exhibit a uniform isotopic ratio, cycled electrodes show a distinct 7Li enrichment in the positive electrode and a corresponding accumulation of 6Li at the surface of the negative electrode. The degree of isotopic separation varies with the charging rate. Isotopic signatures correlate with capacity fading, indicating lithium isotope mapping as a sensitive diagnostic tool for tracking electrode degradation and the evolution of the electrode–electrolyte interphases in LIBs. KW - Li-ion batteries KW - Lithium isotopes KW - Post-mortem analysis KW - GD-MS KW - Depth profile KW - Mass spectrometry PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651287 DO - https://doi.org/10.26434/chemrxiv-2025-5rvlk SP - 1 EP - 19 AN - OPUS4-65128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Battistella, Beatrice A1 - Revill, Adam A1 - Venzago, Cornel A1 - Hoffmann, Volker A1 - Agudo Jácome, Leonardo A1 - Al-Sabbagh, Dominik A1 - Recknagel, Sebastian A1 - Abad, Carlos T1 - Depth-Resolved Lithium Isotope Fractionation as a Diagnostic of Interphase Evolution and Degradation in Lithium-Ion Batteries N2 - Lithium isotopic fractionation is well-established in dynamic geochemical systems; however, its role in lithium-ion batteries (LIBs) remains uninvestigated. Herein, we report the first depth-resolved demonstration that isotopic separation occurs during Li-ion cell operation whose magnitude depends on the cycling history. Using depth-resolved glow discharge mass spectrometry, we monitored the 7Li/6Li ratio in LiNi0.333Mn0.333Co0.333O2 (NMC111)||graphite coin cell electrodes at defined life-cycle stages. Different charging rates were examined to get mechanistic insight into kinetic and thermodynamic control in the fractionation process. Although pristine electrodes exhibit a uniform isotopic ratio, cycled electrodes show a distinct 7Li enrichment in the positive electrode and a corresponding accumulation of 6Li at the surface of the negative electrode. The degree of isotopic separation varies with the charging rate. Isotopic signatures correlate with capacity fading, indicating lithium isotope mapping as a sensitive diagnostic tool for tracking electrode degradation and the evolution of the electrode–electrolyte interphases in LIBs. KW - Lithium-Ion Battery KW - Li Isotopes KW - Glow Discharge Mass Spectrometry GD-MS PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657229 DO - https://doi.org/10.1021/acsenergylett.5c0413737 SN - 2380-8195 VL - 11 IS - 3 SP - 2851 EP - 2857 PB - ACS Publications AN - OPUS4-65722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - The digital reference material document - how to get standards into instruments N2 - Activities of BAm on the transfer of paper-based RM-certificates into machine readable XML-documents, based on the digital calibration certificate are described and highlighted with examples T2 - 2026 European Chemistry Meeting - Jernkontoret TO 45 CY - Stockholm, Sweden DA - 18.03.2026 KW - Reference material KW - Digital reference material document PY - 2026 AN - OPUS4-65737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -