TY - JOUR A1 - Andresen, Elina A1 - Islam, Fahima A1 - Prinz, Carsten A1 - Gehrmann, P. A1 - Licha, K. A1 - Roik, Janina A1 - Recknagel, Sebastian A1 - Resch-Genger, Ute T1 - Assessing the reproducibility and up‑scaling of the synthesis of Er,Yb‑doped NaYF4‑based upconverting nanoparticles and control of size, morphology, and optical properties N2 - Lanthanide-based, spectrally shifting, and multi-color luminescent upconverting nanoparticles (UCNPs) have received much attention in the last decades because of their applicability as reporter for bioimaging, super-resolution microscopy, and sensing as well as barcoding and anti-counterfeiting tags. A prerequisite for the broad application of UCNPs in areas such as sensing and encoding are simple, robust, and easily upscalable synthesis protocols that yield large quantities of UCNPs with sizes of 20 nm or more with precisely controlled and tunable physicochemical properties from lowcost reagents with a high reproducibility. In this context, we studied the reproducibility, robustness, and upscalability of the synthesis of β-NaYF4:Yb, Er UCNPs via thermal decomposition. Reaction parameters included solvent, precursor chemical compositions, ratio, and concentration. The resulting UCNPs were then examined regarding their application-relevant physicochemical properties such as size, size distribution, morphology, crystal phase, chemical composition, and photoluminescence. Based on these screening studies, we propose a small volume and high-concentration synthesis approach that can provide UCNPs with different, yet controlled size, an excellent phase purity and tunable morphology in batch sizes of up to at least 5 g which are well suited for the fabrication of sensors, printable barcodes or authentication and recycling tags. KW - Photoluminescence KW - Nano KW - Nanomaterial KW - Synthesis KW - Reproducibility KW - Upconversion nanoparticle KW - Lanthanide PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-570170 DO - https://doi.org/10.1038/s41598-023-28875-8 SN - 2045-2322 VL - 13 IS - 1 SP - 1 EP - 13 AN - OPUS4-57017 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lisec, Jan A1 - Recknagel, Sebastian A1 - Prinz, Carsten A1 - Vogel, Kristin A1 - Koch, Matthias A1 - Becker, Roland T1 - eCerto—versatile software for interlaboratory data evaluation and documentation during reference material production N2 - The statistical tool eCerto was developed for the evaluation of measurement data to assign property values and associated uncertainties of reference materials. The analysis is based on collaborative studies of expert laboratories and was implemented using the R software environment. Emphasis was put on comparability of eCerto with SoftCRM, a statistical tool based on the certification strategy of the former Community Bureau of Reference. Additionally, special attention was directed towards easy usability from data collection through processing, archiving, and reporting. While the effects of outlier removal can be flexibly explored, eCerto always retains the original data set and any manipulation such as outlier removal is (graphically and tabularly) documented adequately in the report. As a major reference materials producer, the Bundesanstalt für Materialforschung und -prüfung (BAM) developed and will maintain a tool to meet the needs of modern data processing, documentation requirements, and emerging fields of RM activity. The main features of eCerto are discussed using previously certified reference materials. KW - Reference material KW - Statistics KW - Software KW - Collaborative trial PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-591851 DO - https://doi.org/10.1007/s00216-023-05099-3 SP - 1 EP - 9 PB - Springer Science and Business Media LLC AN - OPUS4-59185 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Richter, Silke A1 - Hoppe, Marion A1 - Meckelburg, Angela A1 - Prinz, Carsten A1 - Roik, Janina A1 - Abad Andrade, Carlos Enrique T1 - Powering precision: development of a certified reference material for elemental composition analysis of lithium nickel manganese cobalt oxide (Li-NMC) cathode material for lithium-ion batteries N2 - This work presents the development and certification of the world’s first certified reference material (CRM), BAM-S014, for a lithium nickel manganese cobalt oxide (LiNi0.33Mn0.33Co0.33O2 or Li-NMC 111) cathode material—an integral component in high-energy-density lithium-ion batteries that power electric vehicles (EVs), portable electronics, and stationary energy storage systems. By providing certified mass fractions for 11 elements, this CRM addresses a critical need for accurate and traceable elemental analysis, supporting quality control and regulatory compliance in the global battery industry. Ensuring reliable and harmonized measurements supports the efficient use of resources, including the reuse of recycled materials, and ultimately helps maintain product performance and safety. The values were assigned through an interlaboratory comparison involving 16 participating laboratories and various analytical techniques such as inductively coupled plasma optical emission spectrometry (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), X-ray fluorescence (XRF) spectrometry, and combustion analysis. In addition to chemical characterization, the certification process includes homogeneity and stability testing of the candidate material. Details are provided on the analytical methods used for chemical characterization and the calculation of the uncertainties of the certified mass fractions. In addition to detailing the development of the CRMs, this work provides an overview of ongoing standardization activities in Li-component analysis, thereby guiding the calibration of analytical methods and contributing to the establishment of globally accepted standards for evaluating energy storage materials and advancing sustainable mobility and clean energy solutions. KW - Certified reference material KW - Lithium nickel manganese cobalt oxide KW - LNMC KW - Lithium-ion battery KW - Cathode material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643763 DO - https://doi.org/10.1007/s00216-025-05766-7 SN - 1618-2642 VL - 417 IS - 12 SP - 2643 EP - 2653 PB - Springer Nature AN - OPUS4-64376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Florek, S. A1 - Becker-Ross, H. A1 - Huang, M.-D. A1 - Lopez-Linares, F. A1 - Poirier, L. A1 - Jakubowski, Norbert A1 - Recknagel, Sebastian A1 - Panne, Ulrich T1 - Shake, shut, and go – A fast screening of sulfur in heavy crude oils by highresolution continuum source graphite furnace molecular absorption spectrometry via GeS molecule detection N2 - A fast and simple method for sulfur quantification in crude oils was developed by using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). For this, heavy crude oil samples were prepared as microemulsion (shake) and injected into a graphite furnace (shut). Finally, the concentration of sulfur was determined by monitoring in situ the transient molecular spectrum of GeS at wavelength 295.205nm after adding a germanium solution as molecular forming agent (and go). Zirconium dioxide in the form of nanoparticles (45–55nm) was employed as a permanent modifier of the graphite furnace. Calibration was done with an aqueous solution standard of ammonium sulfate, and a characteristic mass (m0) of 7.5ng was achieved. The effectiveness of the proposed method was evaluated analizing, ten heavy crude oil samples with Sulfur amounts ranging between 0.3 and 4.5% as well as two NIST standard reference materials, 1620c and 1622e. Results were compared with those obtained by routine ICP-OES analysis, and no statistical relevant differences were found. KW - Heavy crude oil KW - Sulfur KW - HR-CS-MAS KW - Germanium sulfide KW - Microemulsion PY - 2019 DO - https://doi.org/10.1016/j.sab.2019.105671 SN - 0584-8547 VL - 160 SP - 105671 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-48747 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - ZRM für die Nichtmetall-Analytik N2 - Die Vorgehensweise bei der Zertifizierung von Referenzmaterialien in der BAM entsprechend den Regeln des ISO-Guide 35 wird an Beispielen beschrieben. Darüber hinaus wird ein umfassender Überblick über Referenzmaterialien zur Analyse der Nichtmetalle Sauerstoff, Wasserstoff, Stickstoff, Kohle und Schwefel gegeben. T2 - Expertentreffen anorganische Materialanalyse CY - Langenselbold, Germany DA - 11.09.2019 KW - ZRM KW - Nichtmetall-Analytik KW - ISO-Guide 35 KW - Referenzmaterialien PY - 2019 AN - OPUS4-49091 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - ISO-Guide 35 in der Praxis eines RM-Herstellers N2 - Der ISO-Guide 35 beschreibt die notwendigen Schritte zur Herstellung von zertifizierten Referenzmaterialien. Anhand praktischer Beispiele wird die Umsetzung des Guide 35 in der BAM dokumentiert. T2 - DAkkS-Informationsveranstaltung - Akkreditierung von Referenzmaterialherstellern; Fachbereich Ringversuche / Referenzmaterialien CY - Berlin, Germany DA - 14.02.2019 KW - ZRM KW - ISO-Guide 35 KW - Referenzmaterial-Herstellung PY - 2019 AN - OPUS4-47395 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - Reference materials for non-metal analysis N2 - The procedure for certification of reference materials in BAM in accordance with the rules of ISO Guide 35 is described using examples. In addition, a comprehensive overview of reference materials for the analysis of non-metals oxygen, hydrogen, nitrogen, coal and sulfur is given. T2 - LECO Workshop: CHNOS determination in inorganic (high tec) materials CY - Berlin, Germany DA - 22.10.2019 KW - CRM KW - Non-metal analysis KW - ISO-Guide 35 KW - Reference materials PY - 2019 AN - OPUS4-49458 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - Certified reference material for the determination of hydrolytic resistance of borosilicate glass N2 - The preparation of certified reference material for the determination of hydrolytic resistance of borosilicate glass is described. Certified properties are the acid consumption according to the relevant standard procedures described in ISO 720, USP<660> and Ph.Eur. 3.2.1. T2 - PharmaGlass Workshop CY - Sheffield, UK DA - 09.10.2019 KW - CRM KW - Hydrolytic resistance KW - Borosilicate glass PY - 2019 AN - OPUS4-49466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Florek, S. A1 - Becker-Ross, H. A1 - Huang, M.-D. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Lippitz, Andreas A1 - Hodoroaba, Vasile-Dan A1 - Schmid, Thomas A1 - Heinrich, Hans-Joachim A1 - Recknagel, Sebastian A1 - Jakubowski, Norbert A1 - Panne, Ulrich T1 - Zirconium permanent modifiers for graphite furnaces used in absorption spectrometry: understanding their structure and mechanism of action N2 - The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings. KW - Zirconium KW - HR-CS-MAS KW - Graphite furnace KW - Nanoparticles KW - Xerogel KW - Calcium monofluoride KW - Absorption spectrometry PY - 2018 UR - https://pubs.rsc.org/en/content/articlelanding/2018/ja/c8ja00190a DO - https://doi.org/10.1039/C8JA00190A SN - 0267-9477 VL - 33 IS - 12 SP - 2034 EP - 2042 PB - Royal Society of Chemistry AN - OPUS4-46775 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Koch, Matthias A1 - Wise, S. A. A1 - Panne, Ulrich T1 - Fifteenth international symposium on biological and environmental reference materials (BERM-15) N2 - The 15th International Symposium on Biological and Environmental Reference Materials (BERM-15), organized by BAM, took place at in Berlin in September 2018. An overview on main topics of the conference is given. KW - BERM KW - Reference materials PY - 2019 DO - https://doi.org/10.1007/s00769-019-01377-9 SN - 1432-0517 SN - 0949-1775 VL - 24 IS - 3 SP - 249 EP - 250 PB - Springer Verlag AN - OPUS4-48203 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Morcillo, Dalia A1 - Winckelmann, Alexander A1 - Oelze, Marcus A1 - Leonhardt, Robert A1 - Schmidt, Anita A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Vogl, Jochen A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Exploring Age-Induced Lithium Isotope Fractionation in Lithium-Ion Batteries using Microwave-Induced Cold Nitrogen Plasma Mass Spectrometry N2 - This study explores Microwave-Inductively Coupled Atmospheric-pressure Plasma Mass Spectrometry (MICAP-MS) as a cost-effective alternative to Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) for analyzing lithium isotopic composition in lithium-ion batteries (LIBs). We investigate the performance of MICAP-MS in measuring Li isotope ratios in new and aged commercial lithium cobalt oxide (LCO) batteries. Our results show that MICAP-MS, operating under cold plasma conditions at 800 W with an 8 mm torch position, achieves results metrologically compatible with MC-ICP-MS, with a precision ranging from 0.6‰ to 3.4‰ for δ7Li values. MICAP-MS benefits from a dielectric resonator for uniform plasma, better ion velocity control, and higher energy efficiency. Optimal settings were identified with dwell times of 10 ms for 6Li and 1 ms for 7Li. The study of LIBs revealed that 6Li migrates towards the anode over multiple charge–discharge cycles, causing 7Li to accumulate in the cathode, a fractionation effect that becomes more pronounced with prolonged cycling. MICAP-MS provides a cost-effective, precise alternative to MC-ICP-MS, with lower operational costs and enhanced portability, advancing the study of isotopic fractionation and aging in lithium-ion batteries. KW - MICAP-MS KW - Lithium KW - Battery aging KW - Lithium isotopes KW - Nitrogen plasma KW - Isotope fractionation KW - lithium cobalt oxide KW - LCO PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643777 DO - https://doi.org/10.1039/d4ja00324a SN - 0267-9477 SP - 1 EP - 11 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abad Andrade, Carlos Enrique A1 - Jegielka, Dennis A1 - Aloysius, Allen A1 - Recknagel, Sebastian T1 - SI-traceable total analysis of nitrate and nitrite by isotope dilution optical spectroscopy and its application to Berlin surface waters N2 - Accurate nitrate and nitrite data support water-quality regulation, yet routine methods rely on external calibration and rarely achieve SI traceability. We report a calibration-free determination of nitrate and nitrite by combining isotope dilution with high-resolution continuum-source graphite furnace molecular absorption spectrometry (ID-HR-CS-GF-MAS). A 15N-enriched nitrate spike (its concentration verified by reverse isotope dilution against the standard reference material NIST 3185) provides the SI link, and it is gravimetrically added to samples; nitrate and residual nitrite are converted in situ to nitric oxide (NO), whose 215 nm band is recorded at a pixel resolution of λ/Δλ ≈ 140 000. The 0.2127 nm shift between 14NO and 15NO electronic spectra is resolved, and a three-latent-variable partial least squares regression model yields the 15N/14N ratio with 0.3% precision. Instrumental LoD values of 4.8 ng (14N) and 3.2 ng (15N) translate to a method LoD of 4.8 ng of nitrogen (equivalent to 1.05 mg L−1 NO3− for a 20 μL aliquot). The furnace program allows for successive drying/pyrolysis loops, so additional 20 μL aliquots can be layered onto the graphite platform. Alternatively, a 10 mL anion-exchange solid-phase extraction step concentrates nitrate and nitrite fivefold, allowing for the analysis of even lower sample concentrations. Results for four certified reference materials (2.9 to 1000 mg L−1 NO3−) agreed with certified values, giving relative expanded uncertainties of 2 to 4%. Analysis of twenty Berlin surface-water samples revealed concentrations ranging from 0.10 to 7.3 mg L−1 NO3−, indicating that the Panke River and Teltow Canal are the primary sources of nitrogen. ID-HR-CS-GF-MAS thus delivers ID-MS-level accuracy in a few minutes per run with bench-top optics, and, with optional on-platform or SPE pre-concentration, extends SI-traceable nitrate/nitrite monitoring into the low-ng regime. KW - Isotope dilution KW - Nitrate and nitrite determination KW - SI-traceable quantification KW - Calibration-free analysis KW - Water quality KW - Berlin surface waters KW - NO molecular absorption bands PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-643785 DO - https://doi.org/10.1039/D5JA00252D SN - 0267-9477 VL - 40 IS - 10 SP - 2692 EP - 2701 PB - Royal Society of Chemistry (RSC) AN - OPUS4-64378 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Morcillo, Dalia A1 - Oelze, Marcus A1 - Seena Prem, Pranav A1 - de Oliveira Guilherme Buzanich, Ana A1 - Emmerling, Franziska A1 - Recknagel, Sebastian A1 - Panne, Ulrich A1 - Abad Andrade, Carlos Enrique T1 - Lithium isotope fractionation as an early indicator of degradation mechanisms in lithium-ion batteries N2 - Aging in lithium-ion batteries (LIBs) degrades performance and hinders sustainability, demanding advanced diagnostics for early failure prediction. We investigate lithium isotope fractionation (LIF) as an innovative probe of degradation in lithium cobalt oxide (LCO) coin cells aged over 0−700 cycles. High-precision multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) quantified δ7Li variations across cell stages: non-cycled (0 cycles), newly formed (5 cycles), semi-aged (250 cycles), and fully aged (700 cycles). During early cycling (≤ 45 cycles), chemical processes drive 7Li enrichment at the anode (δ7Li vs LSVEC = +12 ‰) through solid electrolyte interphase (SEI) formation, while the cathode depletes in 7Li (δ7Li vs LSVEC = −0.7 ‰). Beyond 45 cycles, electric field-induced migration predominates, promoting 6Li intercalation into the anode and increasing the δ7Li of the cathode by 8.1 ‰. Mass balance verifies isotope conservation, attributing shifts to redistribution and trapping. Complementary electrochemical impedance spectroscopy (EIS) and X-ray absorption spectroscopy and diffraction confirm SEI expansion, cobalt oxidation, lattice shrinkage, and changes in electrode structure, corroborating LIF trends. Notably, a δ7Li inflection at approximately 270 cycles anticipates end-of-life by 70 cycles, surpassing traditional methods in sensitivity. LIF emerges as a predictive indicator of aging mechanisms, informing optimized designs for durable LIBs. KW - Lithium isotope fractionation KW - Lithium-ion batteries KW - Degradation mechanisms KW - LiCoO2 cathodes KW - LCO KW - Isotopic tracing KW - Lithium isotopes PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650945 DO - https://doi.org/10.26434/chemrxiv-2025-16lvq SP - 1 EP - 19 AN - OPUS4-65094 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Battistella, Beatrice A1 - Revill, Adam A1 - Venzago, Cornel A1 - Hoffmann, Volker A1 - Agudo Jácome, Leonardo A1 - Al-Sabbagh, Dominik A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Depth-Resolved Lithium Isotope Fractionation as a Diagnostic of Interphase Evolution and Degradation in Lithium Ion Batteries N2 - Lithium isotopic fractionation is well-established in dynamic geochemical systems; however, its role in lithium-ion batteries (LIBs) remains uninvestigated. Herein, we report the first depth-resolved demonstration that isotopic separation occurs during Li-ion cell operation whose magnitude depends on the cycling history. Using depth-resolved glow discharge mass spectrometry, we monitored the 7Li/6Li ratio in LiNi0.333Mn0.333Co0.333O2 (NMC111)||graphite coin cell electrodes at defined life-cycle stages. Different charging rates were examined to get mechanistic insight into kinetic and thermodynamic control in the fractionation process. Although pristine electrodes exhibit a uniform isotopic ratio, cycled electrodes show a distinct 7Li enrichment in the positive electrode and a corresponding accumulation of 6Li at the surface of the negative electrode. The degree of isotopic separation varies with the charging rate. Isotopic signatures correlate with capacity fading, indicating lithium isotope mapping as a sensitive diagnostic tool for tracking electrode degradation and the evolution of the electrode–electrolyte interphases in LIBs. KW - Li-ion batteries KW - Lithium isotopes KW - Post-mortem analysis KW - GD-MS KW - Depth profile KW - Mass spectrometry PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651287 DO - https://doi.org/10.26434/chemrxiv-2025-5rvlk SP - 1 EP - 19 AN - OPUS4-65128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Battistella, Beatrice A1 - Revill, Adam A1 - Venzago, Cornel A1 - Hoffmann, Volker A1 - Agudo Jácome, Leonardo A1 - Al-Sabbagh, Dominik A1 - Recknagel, Sebastian A1 - Abad, Carlos T1 - Depth-Resolved Lithium Isotope Fractionation as a Diagnostic of Interphase Evolution and Degradation in Lithium-Ion Batteries N2 - Lithium isotopic fractionation is well-established in dynamic geochemical systems; however, its role in lithium-ion batteries (LIBs) remains uninvestigated. Herein, we report the first depth-resolved demonstration that isotopic separation occurs during Li-ion cell operation whose magnitude depends on the cycling history. Using depth-resolved glow discharge mass spectrometry, we monitored the 7Li/6Li ratio in LiNi0.333Mn0.333Co0.333O2 (NMC111)||graphite coin cell electrodes at defined life-cycle stages. Different charging rates were examined to get mechanistic insight into kinetic and thermodynamic control in the fractionation process. Although pristine electrodes exhibit a uniform isotopic ratio, cycled electrodes show a distinct 7Li enrichment in the positive electrode and a corresponding accumulation of 6Li at the surface of the negative electrode. The degree of isotopic separation varies with the charging rate. Isotopic signatures correlate with capacity fading, indicating lithium isotope mapping as a sensitive diagnostic tool for tracking electrode degradation and the evolution of the electrode–electrolyte interphases in LIBs. KW - Lithium-Ion Battery KW - Li Isotopes KW - Glow Discharge Mass Spectrometry GD-MS PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-657229 DO - https://doi.org/10.1021/acsenergylett.5c0413737 SN - 2380-8195 VL - 11 IS - 3 SP - 2851 EP - 2857 PB - ACS Publications AN - OPUS4-65722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Recknagel, Sebastian T1 - The digital reference material document - how to get standards into instruments N2 - Activities of BAm on the transfer of paper-based RM-certificates into machine readable XML-documents, based on the digital calibration certificate are described and highlighted with examples T2 - 2026 European Chemistry Meeting - Jernkontoret TO 45 CY - Stockholm, Sweden DA - 18.03.2026 KW - Reference material KW - Digital reference material document PY - 2026 AN - OPUS4-65737 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -