TY - RPRT A1 - Antoni, S. A1 - Clemens, J. A1 - Kunath, K. A1 - Rabe, J. A1 - Simon, K. A1 - Uhlig, S. A1 - Wehrstedt, Klaus-Dieter T1 - Evaluation of the 3rd round robin on solid oxidizer test (UN O.1) with calcium peroxide, sodium nitrate, sodium perborate monohydrate N2 - The classification of solid oxidizers according to the regulations on the transport of dangerous goods (based on the UN Recommendations/Model Regulations and accepted by all international organisations for the transport of dangerous goods as ADR, IMO, IATA) and in future also according to the GHS (Globally Harmonized System of Classification and Labelling of Chemicals) is performed on the basis of the results of the UN test O.1 (UN test O.1 ―Test for oxidizing solids‖ described in chapter 34.4.1 in the Recommendations on the Transport of Dangerous Goods – Manual of Tests and Criteria, see [1]). This test was introduced into the UN Manual of Tests and Criteria in 1995 as a replacement for a similar test from 1986. Even if the UN O.1 test as described in the current 5th revised edition of UN Manual of Tests and Criteria gives some improvements compared to the old test, which had had many deficiencies, there are still some problems left with this test in terms of e.g. repeatability or reproducibility of test results, how to handle compacted or multilayer formulations like tablets, toxicity and partly significantly varying particle size distribution within defined fractions of 150 μm to 300 μm of the reference oxidizer potassium bromate (KBrO3). For this reason the IGUS EOS working group installed an ad-hoc working group in 2002 assigned with the task to propose solutions for the existing problems. The appropriateness of such proposed solutions has to be proved by the method of interlaboratory (round robin) tests before they are presented for the adoption to the UN Committee of Experts on the TDG and on the GHS with a proposal of a completely revised test procedure. KW - Round robin KW - Solid oxidizer test KW - United Nations KW - IGUS KW - EOS KW - Calcium peroxide KW - Sodium nitrate KW - Sodium perborate monohydrate PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-232246 SN - 978-3-9813853-7-3 IS - Final Report, 2009 - 2011 SP - 1 EP - 192 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-23224 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Antoni, S. A1 - Kunath, K. A1 - Lüth, Peter A1 - Simon, K. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test on the method UN O.2 / EC A.21 'Test for oxidizing liquids' 2009 - 2010 N2 - For the classification of chemicals, special standardized test procedures have been developed and are used world-wide. Safe handling and use of these chemicals depend on the correct classification which therefore must be based on the precise and correct execution of the tests and their evaluation. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2009/2010 on the test methods UN O.2 “Test for oxidizing liquids” [1] / EC A.21 “Oxidizing Properties (Liquids)” [2] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. The test methods UN O.2 and EC A.21 are applied to characterize the oxidizing properties of liquid chemical substances or mixtures. To differentiate between chemicals with hazardous / dangerous oxidizing properties and chemicals which are not classified as hazardous / dangerous, the substance’s oxidizing properties are compared to those of a standard reference substance. Since the methods (UN O.2 / EC A.21) were developed and came into force in the early nineties a systematic review concerning the practical application of the test method has not been carried out. KW - Oxidiser KW - Oxidierend KW - Gefahrgut KW - Dangerous goods KW - UN O.2 KW - Prüfmethode KW - Test method PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250904 SN - 978-3-9814634-0-8 SP - 1 EP - 95 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - Final report AN - OPUS4-25090 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Antoni, S. A1 - Kunath, K. A1 - Lüth, Peter A1 - Schlage, R. A1 - Simon, K. A1 - Uhlig, S. A1 - Wildner, W. A1 - Zimmermann, C. T1 - Evaluation of the interlaboratory test on the method UN test O.1 'Test for oxidizing solids' with sodium perborate monohydrate 2005 / 06 N2 - The classification of solid oxidizers according to the GHS (Globally Harmonized System of Classifica-tion and Labelling of Chemicals) and according to regulations on the transport of dangerous goods (based on the UN Recommendations/Model Regulations and implemented in all carrier domains as transport by road, railway, sea, air) is performed on the basis of the results of the UN test O.1 (―Test for oxidizing solids‖ described in chapter 34.4.1 in the Recommendations on the Transport of Danger-ous Goods, Manual of Tests and Criteria, Fifth revised edition, United Nations, New York and Geneva, 2009). This test was introduced into the UN Test Manual in 1995 as a replacement for a similar test from 1986. Even though the O.1 test is much better than the previous one there are still many prob-lems with this test. For this reason the IGUS-EOS working group (international group of experts on the explosion risks of unstable substances – working group: energetic and oxidizing substances) installed an ad-hoc working group in 2002 assigned with the task of proposing solutions for the existing prob-lems. The adequacy of such proposals has to be proven preferably by interlaboratory comparison (interlaboratory test) before they are presented to the UN Sub Committee for adoption into the UN Test Manual. The present report is the evaluation of an interlaboratory test which was designed by the Ad-hoc working group in order to find out whether the current method of comparing combustion times of test mixtures with those of reference mixtures is suitable in principle and whether some approaches for improvement of the method can be identified. KW - Oxidiser KW - Oxidierend KW - Gefahrgut KW - Dangerous goods KW - UN O.1 KW - Prüfmethode KW - Test method PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250919 UR - http://www.bam.de/de/service/publikationen/publikationen_medien/un_test_for_oxidizing_solids_final_report_on_interlab_test.pdf SN - 978-3-9814281-2-4 SP - 1 EP - 65 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - Final report AN - OPUS4-25091 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fricke, F. A1 - Mahmood, S. A1 - Hoffmann, J. A1 - Brandalero, M. A1 - Liehr, Sascha A1 - Kern, Simon A1 - Meyer, Klas A1 - Kowarik, Stefan A1 - Westerdicky, S. A1 - Maiwald, Michael A1 - Hübner, M. T1 - Artificial Intelligence for Mass Spectrometry and Nuclear Magnetic Resonance Spectroscopy N2 - Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control. T2 - 2021 Design, Automation & Test in Europe Conference & Exhibition (DATE) CY - Online meeting DA - 01.02.2021 KW - Industry 4.0 KW - Cyber-Physical Systems KW - Artificial Neural Networks KW - Mass Spectrometry KW - Nuclear Magnetic Resonance Spectroscopy PY - 2021 UR - www.date-conference.com SN - 978-3-9819263-5-4 SP - 615 EP - 620 PB - Research Publishing AN - OPUS4-52180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Oster, Simon A1 - Mann, S. A1 - Sharma, R. A1 - Reisgen, U. T1 - In-situ Identifikation der Schweißnahtgeometrie bei der Anwendung von MSG-Schweißprozessen N2 - Lichtbogenbasierte Schweißverfahren wie das Metallschutzgasschweißen (MSG) zählen zu den Standardverfahren der Fügetechnik und werden in vielen Industriebereichen automatisiert unter Verwendung von Industrierobotern eingesetzt. Dabei können Schweißnahtabweichungen auftreten, die aus Änderungen der Prozessrandbedingungen und der hohen Prozessdynamik resultieren. Hier ist die Kontrolle von Schmelzbad- und Schweißnahtgeometrie für die Sicherung der Nahtqualität bedeutsam. Durch den Einsatz optischer Sensorsysteme können mit hoher zeitlicher Auflösung in-situ Informationen des Prozesszustands ermittelt werden. Dabei stellen die rauen Prozessbedingungen und die hohe Strahlungsintensität des Lichtbogens eine Herausforderung für die optischen Komponenten dar. Forschungsarbeiten am Institut für Schweißtechnik und Fügetechnik der RWTH Aachen haben gezeigt, dass durch den Einsatz einer HDR-Kamera in Kombination mit einer strukturierten Laserbelichtung gezielt geometrische Informationen des Lichtbogens und des Schmelzbads aus den Prozessaufnahmen gewonnen werden können. In dieser Arbeit wird eine parallele Schweißnaht- und Schmelzbadbeobachtung durchgeführt, wobei geometrische Informationen durch die Anwendung von Bildverarbeitungsalgorithmen extrahiert werden. Dabei wird ein nachlaufendes Sensorsystem eingesetzt, welches aus einer HDR-Kamera und einer Laserbeleuchtung besteht. Es werden diffraktive optische Elemente (DOE) zur Erzeugung von verschiedenen Laserprojektionsmustern verwendet, um sowohl eine unidirektionale als auch eine multidirektionale Prozessbeobachtung durchführen zu können. Aus den geometrischen Informationen werden Kenngrößen berechnet, anhand derer der Prozesszustand beurteilt werden kann. Es zeigt sich, dass anhand der Kenngrößenverläufe Abweichungen in der Schweiß- und Schmelzbadgeometrie und Positionierungsfehler des Roboters identifiziert werden können. T2 - Große Schweißtechnische Tagung - DVS CAMPUS CY - Online meeting DA - 14.09.2020 KW - Schweißnahtgeometrie KW - MSG-Schweißen KW - In-situ Monitoring KW - Schmelzbadbeobachtung PY - 2020 SN - 978-3-96144-098-6 VL - 365 SP - 41 EP - 47 PB - DVS Media GmbH CY - Düsseldorf AN - OPUS4-51576 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kalbe, Ute A1 - Witt, K. J. A1 - Simon, Franz-Georg A1 - Prohaska, S. A1 - Slowik, V. T1 - Bedingungen suffosiver Erosionsphänomene in Böden N2 - Für eine detaillierte Analyse der Gefüge- und Porenstruktur weitgestufter Erdstoffe ist es notwendig, diese dreidimensional (3D) zu visualisieren und ihre Kenngrößen zu ermitteln. Dazu wurde an der BAM eine Präparationsmethode entwickelt, die es ermöglicht die Porenstruktur von Probenkörpern aus suffosiven Erdstoffen und definierten Korngrößenverteilungen über CT-Aufnahmen abzubilden. Über eine eigens dafür, in Zusammenarbeit mit dem Zuse-Institut Berlin (ZIB), entwickelte Bildanalysemethode wurden die Strukturdaten visualisiert. Aus dem Bilddatensatz konnte bereits in der Rückwärtsrechnung eine Kornverteilungslinie zur Validierung generiert und mit experimentell ermittelten Sieblinien verglichen werden. Des Weiteren wurden in Säulenexperimenten Kornumlagerungsprozesse unter der Verwendung von CT-Aufnahmen beobachtet. Als eine weitere Möglichkeit zur Beschreibung von Gefüge- und Porenstrukturen wurden Kugelpackungen modelliert und deren Strukturdaten ermittelt. Mit einem an der HTWK entwickelten stochastisch-heuristischen Algorithmus lassen sich wirklichkeitsnahe 3D-Gefügemodelle aus kugelförmigen Feststoffpartikeln generieren. Die Kornverteilung ist dabei wählbar. Für die erstellten Gefügemodelle kann der vollständige Porengraph einschließlich der Porengrößen und Engstellen ermittelt und ausgelesen werden. Ein an der BAM entwickelter und durch die BUW erweiterter Säulenversuch unter Verwendung systematisch veränderter Korngemische von natürlichen Gesteinskörnungen und Glaskugeln ergab weitere Aufschlüsse über die strukturbildenden Fraktionen des Korngerüstes. Die Perkolationstheorie ist eine moderne wahrscheinlichkeitstheoretische Methode, um Fluss- und Transportvorgänge innerhalb poröser Medien zu simulieren. Über Porennetzwerkmodelle werden die komplexen Fließwege in der Porenstruktur vereinfacht abgebildet. An der BUW wurde ein 3D-Bond-Perkolationsmodell auf einem simplen kubischen Gitter realisiert, in dem die Gitterknoten die Poren und die Gitterstäbe die Porenengstellen repräsentieren. Lokale und globale Strukturveränderungen infolge Partikeltransports werden über die Analyse von Porenräumen beschrieben. Mit diesem Perkolationsmodell können Aussagen zur lokalen und globalen Strukturveränderung durch Partikeltransport in definierten Bodenvolumen abgeleitet werden. Die hergeleiteten Zusammenhänge zu den suffosiven Materialtransportbedingungen mit der Perkolationstheorie sind für homogene, isotrope und selbstähnliche Erdstoffgefüge gültig. KW - Wasserbau KW - Bodenmechanik PY - 2012 VL - SI 1382/1-2 SP - 1 EP - 24 AN - OPUS4-52427 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Abis, M. A1 - Bruno, M. A1 - Simon, Franz-Georg A1 - Grönhom, R. A1 - Kuchta, K. A1 - Fiore, S. ED - Medici, F. T1 - A Novel Dry Treatment for Municipal Solid Waste Incineration Bottom Ash for the Reduction of Salts and Potential Toxic Elements N2 - The main obstacle to bottom ash (BA) being used as a recycling aggregate is the content of salts and potential toxic elements (PTEs), concentrated in a layer that coats BA particles. This work presents a dry treatment for the removal of salts and PTEs from BA particles. Two pilotscale abrasion units (with/without the removal of the fine particles) were fed with different BA samples. The performance of the abrasion tests was assessed through the analyses of particle size and moisture, and that of the column leaching tests at solid-to-liquid ratios between 0.3 and 4. The results were: the particle-size distribution of the treated materials was homogeneous (25 wt % had dimensions <6.3 mm) and their moisture halved, as well as the electrical conductivity of the leachates. A significant decrease was observed in the leachates of the treated BA for sulphates (44%), chlorides (26%), and PTEs (53% Cr, 60% Cu and 8% Mo). The statistical analysis revealed good correlations between chloride and sulphate concentrations in the leachates with Ba, Cu, Mo, and Sr, illustrating the consistent behavior of the major and minor components of the layer surrounding BA particles. In conclusion, the tested process could be considered as promising for the improvement of BA valorization. KW - Bottom ash KW - Dry treatment KW - Municipal solid waste PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552161 SN - 978-3-0365-3063-5 DO - https://doi.org/10.3390/ma14113133 SP - 57 EP - 71 PB - MDPI CY - Basel AN - OPUS4-55216 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gottu Mukkula, A. R. A1 - Engell, S. A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Maiwald, Michael T1 - PAT-basierte iterative Optimierung der Fahrweise eines kontinuierlichen organischen Syntheseprozesses N2 - Im Zuge der Digitalisierung der Prozessindustrie werden zunehmend modellbasiere Echtzeitoptimierungsverfahren eingesetzt, sog. „Advanced Process Control“. Mithilfe der sogenannten Modifier-Adaptation ist eine iterative Betriebspunktoptimierung auch mit ungenauen Modellen möglich, sofern zuverlässige Prozessdaten zur Verfügung stehen. Am Beispiel eines smarten Online-NMR-Sensors, der in einem EU-Projekt von der BAM entwickelt wurde, konnte das Konzept in einer modularen Produktionsanlage zur Herstellung eines pharmazeutischen Wirkstoffs erfolgreich getestet werden. T2 - ProcessNet-Jahrestagung und 33. DECHEMA-Jahrestagung der Biotechnologen CY - Aachen, Germany DA - 10.09.2018 KW - Prozessanalytik KW - Echtzeitoptimierungsverfahren KW - Modifier-Adaptation KW - Prozess-Steuerung KW - Betriebspunktoptimierung KW - CONSENS PY - 2018 UR - https://onlinelibrary.wiley.com/doi/abs/10.1002/cite.201855233 DO - https://doi.org/10.1002/cite.201855233 SN - 0009-286X VL - 90 SP - 1237 EP - 1237 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-45902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kern, Simon A1 - Wander, Lukas A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gottu Mukkula, A. R. A1 - Holtkamp, M. A1 - Salge, M. A1 - Fleischer, C. A1 - Weber, N. A1 - Engell, S. A1 - Paul, Andrea A1 - King, R. A1 - Maiwald, Michael T1 - Raw data of pilot plant runs for CONSENS project (Case study 1) N2 - In case study one of the CONSENS project, two aromatic substances were coupled by a lithiation reaction, which is a prominent example in pharmaceutical industry. The two aromatic reactants (Aniline and o-FNB) were mixed with Lithium-base (LiHMDS) in a continuous modular plant to produce the desired product (Li-NDPA) and a salt (LiF). The salt precipitates which leads to the formation of particles. The feed streams were subject to variation to drive the plant to its optimum. The uploaded data comprises the results from four days during continuous plant operation time. Each day is denoted from day 1-4 and represents the dates 2017-09-26, 2017-09-28, 2017-10-10, 2017-10-17. In the following the contents of the files are explained. KW - Process Analytical Technology KW - Multivariate Data Analysis KW - Nuclear Magnetic Resonance KW - Near Infrared Spectroscopy KW - Continuous Manufacturing KW - CONSENS PY - 2018 DO - https://doi.org/10.5281/zenodo.1438233 PB - Zenodo CY - Geneva AN - OPUS4-48063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nusser, A. A1 - Osterloh, Kurt A1 - Freitag, M. A1 - Simon, S. ED - Reiche, I. T1 - Analyse von mit Carbolineum belastetem Kulturgut und modellhafte Erprobung konservatorischer Dekontaminierung N2 - The baroque epitaph Reyer (1704) at the St. Laurentius church in Tönning was treated with carbolineum as a wood preservation agent in 1903. The subsequent constant migration of carbolineum through the layers of paint to the surface has had a detrimental effect on the aesthetic appearance of the epitaph. Carbolineum is an oily, water-insoluble, flammable, dark brown mixture of coal tar oil components. Due to its content of polycyclic aromatic hydrocarbons (PAH), which are classified as carcinogenic and harmful to the environment, the use of carbolineum has been forbidden. The aim of the project is to develop an exemplary Conservation treatment (hat will reduce the toxic contents of the historical wooden object. The new method should be applicable to similar objects that are also contaminated with carbolineum. The historic carbolineum was identified by the GC-MS method and the X-Ray computed tomography revealed the biological wood damage and previous restoration measures. Several decontamination methods such as the extraction with supercritical C02, with dichloromethane vapour/fluids, with 1,3-dioxolane or with petrol ether by vaccum impregnation were investigated. This project is founded by the Deutsche Bundesstiftung Umwelt (DBU). KW - Kulturgut aus Holz KW - Holzschutz KW - Computertomographie PY - 2014 SN - 0344-5089 VL - 22 SP - 77 EP - 82 PB - Rathgen-Forschungslabor CY - Berlin AN - OPUS4-32516 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Simon, Franz-Georg A1 - Ludwig, S. A1 - Meggyes, Tamás A1 - Stewart, D. A1 - Roehl, K. ED - Roehl, K. T1 - Regulatory and economic aspects KW - Groundwater remediation KW - Permeable Reactive Barrier KW - Long-term Performance KW - Elemental Iron KW - Hydroxyapatite PY - 2005 SN - 0-444-51536-4 N1 - Serientitel: Trace metals and other contaminates in the environment – Series title: Trace metals and other contaminates in the environment IS - 7 SP - 311 EP - 321 PB - Elsevier CY - Amsterdam AN - OPUS4-7546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krug, Sonja A1 - Simon, S. ED - Brückle, I. ED - Hahn, O. ED - Bredekamp, H. T1 - Digital image analysis N2 - Comparatiye digital analysis was performed on the five moon drawings from the New York copy of the Sidereus Nuncius and the copperplate etchings printed in the Graz and Florence copies. The sequences of figures for the drawings on pages 8r, 9v and lOv demonstrate the process of digitally enhancing the black material on the drawings, isolating that material and then overlaying it on the etchings. Using an image editing program (Image Pro® Plus by Media Cybernetics) the black material on the drawings and the letterpress-printed text were isolated and segmented from the brown drawing media. As shown in Figs. 4, 6 and 8, the isolation was possible and the black material clearly overlaps the demarcation line in the drawings. To compare the drawn and printed images of each moon, the images were laid on top of each other with Adobe Photoshop® (Adobe Systems). In these images, the printed text was used for alignment and scale. By decreasing the opacity of the image on top, the lines of each image were compared. This technique revealed an almost one-to-one correlation between the demarcation line in the drawing (as indicated by the black material) and that on the etching. In each case, the similarities and concurrences by far outnumbered the minor deviations in line. One precondition of this work was that all the photographs be at the same angle, plane-parallel, so that the drawings could be compared with the etchings. A slight aberration in the plane could distort the geometry of the illustrations. Rectification of the image plane was carried out by means of the program metigo® MAP 2.2 (Fokus GmbH Leipzig). To validate the method, photographs from the same detail of the New York copy taken with different photographic cameras and different Parameters were rectified with metigo® MAP and compared in Adobe Photoshop®. The overlay of these photographs shows a good correlation in the layout of the lettering and moon figures with only small aberrations. The distribution of the black material on the drawings can be followed as clearly in the rectified photographs as in the unrectified photographs, the information is the same. PY - 2011 SN - 978-3-05-005095-9 SP - 94 EP - 97 PB - Akademie Verlag GmbH CY - Berlin AN - OPUS4-27538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kunath, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test 2010-2011 on the method DIN EN15188:2007 'Determination of the spontaneous ignition behaviour of dust accumulations' N2 - For the classification and safe handling and use of the chemicals, special standardized testing proce-dures have been developed and are used world-wide. Safety experts must be able to fully rely on the precise execution of the respective laboratory tests and assessments. In this context interlaboratory tests (round robin tests, interlaboratory comparisons / intercomparisons) are a crucial element of a laboratory's quality system. Participation in interlaboratory tests is explicitly recommended by the standard ISO/IEC 17025. The present document reports on the results of the interlaboratory test 2010/2011 on the test method DIN EN 15188:2007 “Determination of the spontaneous ignition behaviour of dust accumulations” [1] which was organized by the Center for Quality Assurance for Testing of Dangerous Goods and Haz-ardous Substances. The test method DIN EN 15188:2007 is applied to characterize the self-ignition behaviour of combus-tible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the de-termination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially availa-ble ovens. The results thus measured reflect the dependence of self-ignition temperatures upon dust volume [1]. Several internal investigations and interlaboratory comparisons in the past have shown significant differences between the lab-specific results of hot storage tests. Figure 2-1 shows the Pseudo-Arrhenius plot of hot storage tests of eight different laboratories (Round Robin Test 2002, BAM). The dust under this investigation was Lycopodium powder (spores). The par-ticipants of this interlaboratory test used different laboratory ovens (size, ventilation) as well as differ-ent sample baskets (shape, mesh size, single- and double-walled). Figure 2-1 shows clearly that this test failed to produce reasonable reproducibility of the TSI between the different laboratories. As possible reasons for the deviations have been identified lab-specific dif-ferences, e.g.: - oven ventilation (enforced, natural convection), - oven size, - sample baskets, - radiation effects, - measuring precision (temperature difference between tests with ignition and no ignition), - minimum sample size. To reduce the differences between the labs it was necessary to ameliorate the testing method and to improve the execution of the method by the lab. From there, the installation of an inner chamber into the laboratory oven was suggested as experimental set-up in EN 15188:2007 to provide more repro-ducible test conditions. The aappropriateness of this set-up has not been verified yet. The current interlaboratory test 2010-2011 focuses on the use of a special mesh wire screen and spe-cial volumes of the sample baskets (cubes) to normalise/harmonise the test conditions in the different labs. In preparation for the interlaboratory test a joint program between Syngenta and BAM has been initiated in 2009. As a result of these investigations a modified set-up ( chapter 3) has been identi-fied to be probably more appropriate than the suggested set-up in DIN EN-15188:2007. Due to the time-consuming test procedure and to optimize the workflow for the laboratories this in-terlaboratory test should be performed stepwise as a multi-level test ( chapter 5.4) on one typical test sample. KW - Interlaboratory test KW - Self-ignition KW - Spontaneous ignition PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-282978 SN - 978-3-9815748-4-5 IS - Final Report SP - 1 EP - 113 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-28297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - BOOK A1 - Hahn, Oliver A1 - Oesterle, D. A1 - Bretz, S. A1 - Steger, Simon A1 - Stege, H. A1 - Dietemann, P. A1 - Baumer, U. ED - Hahn, Oliver ED - Oesterle, D. ED - Bretz, S. ED - Doil, Thorsten T1 - Hinter Glas gemalt - Geheimnisse einer Technik - Eine Ausstellung im Museum Penzberg – Sammlung Campendonk im Rahmen des Forschungsprojektes "Hinterglasmalerei als Technik der Klassischen Moderne 1905-1955" N2 - Mit der Bezeichnung Hinterglasmalerei wird allgemein der Begriff der Glasmalerei assoziiert. Auch wenn in beiden Fällen Glas das Trägermaterial ist, bezeichnet Hinterglasmalerei jedoch eine völlig andere Technik. Während bei der Glasmalerei die Farben auf den Bildträger eingebrannt werden, handelt es sich bei der Hinterglasmalerei um eine Kaltmalerei. Selbsttrocknende Farben werden auf die Rückseite der Glastafel aufgetragen, zuweilen wird die Malweise durch aufwendige Veredelungstechniken ergänzt. Mehr und mehr rückt diese Technik, die materialtechnologisch zwischen Tafelmalerei und Glasmalerei zu verorten ist, in den Blickwinkel einer interessierten Öffentlichkeit, wie dies eine zunehmende Anzahl verschiedener Ausstellungen zur Hinterglasmalerei belegen. Die vorliegende Publikation beschäftigt sich in erster Linie mit kunsttechnologischen und materialanalytischen Aspekten der Hinterglasmalerei und ermöglicht tiefe Einblicke in die künstlerische Arbeitsweise und in die Verwendung unterschiedlichster Materialien. T2 - Ausstellung Hinterglasmalerei CY - Penzberg, Germany DA - 19.12.2020 KW - Archäometrie KW - Hinterglasmalerei KW - Kunsttechnologie KW - Zerstörungsfreie Prüfung PY - 2021 SN - 2567-1251 VL - 2 SP - VII EP - 103 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-55155 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kern, Simon A1 - Liehr, Sascha A1 - Wander, Lukas A1 - Bornemann-Pfeiffer, Martin A1 - Müller, S. A1 - Maiwald, Michael A1 - Kowarik, Stefan T1 - Training data of quantitative online NMR spectroscopy for artificial neural networks N2 - Data set of low-field NMR spectra of continuous synthesis of nitro-4’-methyldiphenylamine (MNDPA). 1H spectra (43 MHz) were recorded as single scans. Two different approaches for the generation of artificial neural networks training data for the prediction of reactant concentrations were used: (i) Training data based on combinations of measured pure component spectra and (ii) Training data based on a spectral model. Synthetic low-field NMR spectra First 4 columns in MAT-files represent component areas of each reactant within the synthetic mixture spectrum. Xi (“pure component spectra dataset”) Xii (“spectral model dataset”) Experimental low-field NMR spectra from MNDPA-Synthesis This data set represents low-field NMR-spectra recorded during continuous synthesis of nitro-4’-methyldiphenylamine (MNDPA). Reference values from high-field NMR results are included. KW - NMR spectroscopy KW - Real-time process monitoring KW - Artificial neural networks KW - Online NMR spectroscopy KW - Automation KW - Process industry PY - 2020 DO - https://doi.org/10.5281/zenodo.3677139 PB - Zenodo CY - Geneva AN - OPUS4-50456 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krüger, Oliver A1 - Kalbe, Ute A1 - Berger, Wolfgang A1 - Simon, Franz-Georg A1 - López Meza, S. T1 - Leaching experiments on the release of heavy metals and PAH from C&D waste and MSWI bottom ash N2 - Leaching tests are fundamental tools for the assessment of long-term impact of contaminated waste materials on the soil-groundwater pathway. Waste materials should be tested under conditions equal to their actual application in re-use scenarios to achieve reliable results. Since the standards for leaching procedures available on international level so far are either not validated or considered inadequate in respect to coarse grained materials, new standards had to be developed. Therefore column percolation and batch test procedures have been standardized and validated to enable their introduction to new German regulations concerning waste management. Practical aspects of the test procedures as well as the boundary conditions compared to the already existing standards will be described. Examples including round robin test results will be given to justify the selection of the new specifications. T2 - 2nd International conference on hazardous and industrial waste management CY - Chania, Crete, Greece DA - 2010-10-05 KW - Leaching KW - Bioavailability KW - Column tests KW - Batch tests PY - 2010 IS - Session A, A5.1. SP - 1 EP - 8 AN - OPUS4-22128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ziegler, Mathias A1 - Altenburg, Simon A1 - Krankenhagen, Rainer A1 - Maierhofer, Christiane A1 - Scheuschner, Nils A1 - Marquardt, E A1 - Mühlberger, W. A1 - Nagel, F. A1 - Neumann, E. A1 - Rohwetter, P. A1 - Rutz, F. A1 - Schwake, C. A1 - Schramm, S. A1 - Schwaneberg, F. A1 - Taubert, R. D. T1 - Thermografie und Strahlungsthermometrie - Stand und Trends N2 - In vielen Umgebungen, besonders bei hohen Temperaturen, korrosiven Umgebungen oder auf bewegten oder schlecht zugänglichen Flächen, kann die Temperatur nicht oder nur mit nicht akzeptablem Aufwand mit Berührungsthermometern gemessen werden. Diese Umgebungsbedingungen sind unter anderem in der chemischen Industrie, der Lebensmittel-, Metall-, Glas-, Kunststoff- und Papierherstellung sowie bei der Lacktrocknung anzutreffen. In diesen Bereichen kommen Strahlungsthermometer zum Einsatz. Der VDI-Statusreport zeigt typische Anwendungsfelder von nicht radiometrisch kalibrierten Wärmebildkameras und von radiometrisch kalibrierten Thermografiekameras. Um verlässlich mit spezifizierten Messunsicherheiten berührungslos Temperaturen zu messen, müssen die Strahlungsthermometer und Thermografiekameras nicht nur kalibriert, sondern radiometrisch und strahlungsthermometrisch umfassend charakterisiert werden. Auch die optische Materialeigenschaft, der spektrale Emissionsgrad und die Gesamtstrahlungsbilanz (Strahlung des Messobjekts und der Umgebung) sind bei der industriellen Temperaturmessung von großer Bedeutung. In den letzten Jahrzehnten ist dazu ein umfassendes technisches Regelwerk entstanden, das wir Ihnen mit diesem VDI-Statusreport vorstellen. Manche in den Richtlinien beschriebenen Kennwerte mögen abstrakt wirken. In diesem Statusreport zeigen wir an konkreten Beispielen, was diese Kenngrößen für die berührungslose Temperaturmessung bedeuten. Beispiele von Anwendungen zeigen, wo temperaturmessende Thermografiekameras und ausschließlich bildgebende Wärmebildkameras in der Praxis eingesetzt werden. Mit einer Analyse, welche Themen und Anwendungen derzeit besonders intensiv diskutiert werden, versuchen wir Trends für zukünftige Entwicklungen herauszuarbeiten. KW - Thermografie KW - Temperaturmessung PY - 2021 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/thermografie-und-strahlungsthermometrie-stand-und-trends SP - 1 EP - 40 PB - VDI Verein Deutscher Ingenieure e.V. CY - Düsseldorf AN - OPUS4-52904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Frost, K. A1 - Lüth, Peter A1 - Schmidt, Martin A1 - Simon, K. A1 - Uhlig, S. T1 - Interlaboratory test 2023 on the method DIN EN 15188:2021-07 "Determination of the spontaneous ignition behaviour of dust accumulations" - Final report of results N2 - The test method DIN EN 15188:2021-07 “Determination of the spontaneous ignition behaviour of dust accumulations” is applied to characterize the self-ignition behaviour of combustible dusts. The experimental basis for describing the self-ignition behaviour of a given dust is the determination of the self-ignition temperatures (TSI) of differently-sized volumes of the dust sample by isoperibolic hot storage experiments (storage at constant oven temperatures) in commercially available ovens. The results measured this way reflect the dependence of the self-ignition temperatures on the volume of a dust accumulation. Several internal investigations in the past (e.g. interlaboratory tests in 2010-2011 and 2015-2016) have shown significant differences between the lab-specific results of hot storage tests of the former version of the revised DIN EN 15188:2021-07 (DIN EN 15188:2007). Therefore, an improvement of the test method DIN EN 15188:2007 was necessary. After a rather long and extensive series of various improvements (methodological modifications), the interlaboratory test in 2015-2016 demonstrated an acceptable reliability of the test method and a satisfactory measurement uncertainty if the modifications described in the interlaboratory test are taken into account. On the basis of this interlaboratory test in 2015, this subsequently led to a revision of the standard, whereby, in addition to the methodological improvements, the measurement uncertainty to be taken into account could now also be specified for the first time in this standard. The revised DIN EN 15188:2021-07 was published in 2021 and can now be applied by laboratories. This report provides the laboratory results of the first interlaboratory test 2023 on the revised method DIN EN 15188:2021-07 and summarizes the results of the assessment of laboratory performance. KW - DIN EN 15188:2021-07 KW - Spontaneous ignition KW - Interlaboratory test KW - Round robin test KW - Proficiency test KW - Dangerous goods KW - Hazardous substances KW - Measurement uncertainty KW - Gefahrgut KW - Gefahrstoff KW - Qualitätssicherung KW - Ringversuch KW - Selbstentzündung KW - Staub KW - Dust PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614560 SN - 978-3-9818564-6-0 DO - https://doi.org/10.26272/opus4-61456 SP - 1 EP - 51 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin ET - 1. AN - OPUS4-61456 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Wander, Lukas A1 - Meyer, Klas A1 - Guhl, Svetlana A1 - Gottu Mukkula, A. R. A1 - Holtkamp, M. A1 - Salge, M. A1 - Fleischer, C. A1 - Weber, N. A1 - King, R. A1 - Engell, S. A1 - Paul, Andrea A1 - Pereira Remelhe, M. A1 - Maiwald, Michael T1 - Flexible Automation with compact NMR instruments N2 - Modular plants using intensified continuous processes represent an appealing concept to produce pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes, and it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and includes a compact Nuclear Magnetic Resonance (NMR) spectrometer for online quality monitoring as well as a new model-based control approach. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including ro-bust evaluation of sensor data. Here, we present alternatives for the quantitative determination of the analytes using modular, physically motivated models. These models can be adapted to new substances solely by the use of their corresponding pure component spectra, which can either be derived from experimental spectra as well as from quantum mechanical models or NMR predictors. Modular means that spec-tral models can simply be exchanged together with alternate reagents and products. Beyond that, we comprehensively calibrated an NIR spectrometer based on online NMR process data for the first time within an industrial plant. The integrated solution was developed for a metal organic reac-tion running on a commercial-scale modular pilot plant and it was tested under industrial conditions. T2 - 7th Annual PANIC Conference CY - Hilton Head Island, South Carolina, USA DA - 03.03.2019 KW - Online NMR Spectroscopy PY - 2019 AN - OPUS4-47715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mundra, S. A1 - Furcas, F. E. A1 - Huthwelker, T. A1 - Simon, Sebastian A1 - Borca, C. N. A1 - Provis, J. L. A1 - Gluth, Gregor T1 - Kinetics of Sulfide Oxidation in alkaline solutions studied by X-ray absorption near-edge structure spectroscopy N2 - The oxidation of sulfur in aqueous solutions is an important process in several geochemical and industrial contexts. In concrete technology, it is particularly relevant for the protection of steel reinforcement in slag cement-based concretes, as the presence of sulfides affects the passivation of the steel and corrosion initiation in the presence of chlorides. However, the knowledge about the kinetics of sulfide oxidation in alkaline solutions, such as concrete pore solutions, is incomplete. To address this issue, we prepared solutions with 0.80 M NaOH, and nominally 10, 100 and 350 mM HS−, respectively, and followed the evolution of the sulfur species during bubbling with oxygen-containing gas (concentration 100% or 22%) using X-ray absorption near-edge structure (XANES) spectroscopy at the sulfur K-edge. Polysulfide, thiosulfate, sulfite and sulfate were identified and quantified via linear combination fitting of the spectra, using previously measured standards. A preliminary analysis of the results shows that the initial rate constant of sulfide oxidation depends strongly on the HS− concentration, while it less strongly depending on the oxygen concentration, in line with previous results for lower pH values. Approaches to fit the data to obtain the rate constants of all relevant reactions will be discussed. T2 - 41st Cement & Concrete Science Conference CY - Leeds, Great Britain DA - 12.09.2022 KW - XANES KW - Sulfide oxidation KW - Kinetics PY - 2022 SP - 1 EP - 3 PB - Institute of Materials, Minerals & Mining (IOM3) AN - OPUS4-55650 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brandes, E. A1 - Colson, B. A1 - Frost, K. A1 - Lüth, Peter A1 - Simon, K. A1 - Stolz, T. A1 - Uhlig, S. T1 - Evaluation of the interlaboratory test 2015 – 2016 on the method UN Test L.2 “Sustained combustibility test” / EN ISO 9038:2013 “Determination of sustained combustibility of liquids" N2 - The test methods UN Test L.2 / EN ISO 9038:2013 DIN EN 15188:2007 are applied to characterize the sustained combustibility of liquids i.e. the behaviour of a material under specified test conditions, whereby its vapour can be ignited by an ignition source and sufficient flammable vapour is produced to continue burning for at least 15 s after the source of ignition has been removed. The aims of this interlaboratory test (IT) are the verification and/or the improvement (if necessary) of the verification data (reference material) in Annex B of EN ISO 9038:2013, the assessment of influencing (disturbing) factors (laboratory specific factors, which possibly may have an influence on the test result) and the assessment of the performance of the participating laboratories. It could be demonstrated that the reference materials n-Dodecane, n-Decane and n-Undecane as mentioned in the standard are suitable and the verification shall continue to be valid. Sustained combustibility tests are influenced by several factors like the presence of a draught shield, the experience of the laboratory assistant, verification of the apparatus, calibration of the metering device. Based on the interlaboratory test, the gained experience and the actual results, well-founded measures / actions can be recommended to improve execution of the method. The IT was organized by PTB, BAM and QuoData GmbH in the framework of the co-operation project CEQAT-DGHS Centre for Quality Assurance for Testing of Dangerous Goods and Hazardous Substances. KW - Dangerous goods KW - Hazardous substances KW - Test method KW - Quality assurance KW - Interlaboratory comparison KW - Round robin test KW - Validation KW - Sustained combustibility KW - Reference material KW - Gefahrgut KW - Gefahrstoff KW - Prüfmethode KW - Qualitätssicherung KW - Ringversuch KW - Validierung KW - Selbstunterhaltende Verbrennung KW - Referenzmaterial PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-410270 SN - 978-3-9818270-3-3 SP - 1 EP - 103 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-41027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -