TY - JOUR A1 - Göbel, M. A1 - Kirsch, S. A1 - Schwarze, L: A1 - Schmidt, L. A1 - Scholz, H. A1 - Haußmann, J. A1 - Klages, M. A1 - Scholta, J. A1 - Markötter, Henning A1 - Alrwashdeh, S. A1 - Manke, I. A1 - Müller, Bernd R. T1 - Transient limiting current measurements for characterization of gas diffusion layers N2 - The water management in proton exchange membrane fuel cells (PEMFC) is strongly influenced by the design of the gas diffusion layers (GDL). Limiting current measurements in small-scale cells operating at high stoichiometries are useful to determine the oxygen transport resistance. The oxygen transport resistance increases, once water condenses inside the GDL. In this study a new electrochemical method for voltage loss estimation of GDL induced oxygen transport losses are presented. This new method, referred to as “transient limiting current” (TLC), is compared with the literature method. TLC allows a direct estimation of oxygen transport resistance at an arbitrarily conditioned state. This study also presents a case study of liquid water visualization of a PEM fuel cell with varying GDLs types. With the help of quasi in-situ synchrotron X-ray computed tomography and time resolved radiography measurements we investigate appearance and distribution of liquid water inside the GDLs under limiting current conditions. KW - In-situ characterization of GDLs KW - In-situ synchrotron X-ray computed tomography KW - In-situ synchrotron X-ray radiography KW - BAMline PY - 2018 DO - https://doi.org/10.1016/j.jpowsour.2018.09.003 SN - 0378-7753 SN - 1873-2755 VL - 402 SP - 237 EP - 245 PB - Elsevier B.V. AN - OPUS4-46552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit - Schlussfolgerungen N2 - Die Ursachen für Chemikalienunfälle können vielfältig sein. Prävention beginnt bereits im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2019 UR - https://www.ptb.de/cms/index.php?id=18763 DO - https://doi.org/10.7795/210.20190521M SP - 1 EP - 8 PB - Physikalisch-Technische Bundesanstalt (PTB) CY - Braunschweig AN - OPUS4-49489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Entwicklung von Verfahren zur Verifizierung der Prüfapparatur am Beispiel der Prüfmethode UN Test N.5 N2 - Prävention beginnt im Prüflabor, wenn Chemikalien auf ihre gefährlichen Eigenschaften getestet werden. Dazu sind Prüfmethoden entwickelt und veröffentlicht worden, die heute weltweit Anwendung finden. Auf die Validität der Prüfmethode und richtige Durchführung der Prüfung im Laboratorium müssen sich Sicherheitsfachkräfte, Transporteure oder Händler verlassen können. Anhand der in den letzten 10 Jahren im Rahmen des CEQAT-DGHS von BAM und PTB durchgeführten Ringversuche (RV) wird gezeigt, dass bei allen bisher untersuchten Prüfmethoden ein Verbesserungsbedarf besteht. Die RV müssen daher zunächst auf die Methodenverbesserung und -validierung abzielen und nicht auf Leistungstests. Das Labormanagement und die praktische Durchführung der Prüfung sind in vielen Laboratorien verbesserungsbedürftig. Der Begriff „Erfahrung der Prüfer“ ist kritisch zu sehen: Eine „lange Erfahrung mit vielen Prüfungen“ ist nicht unbedingt ein Garant für richtige Ergebnisse. Bei der Prüfung der gefährlichen Eigenschaften von Chemikalien sind Referenzmaterialen auf Grund der Instabilität in der Regel nicht verfügbar. Für Prüflaboratorien sind RV daher eine Alternative bei der Qualitätssicherung. RV sind jedoch aufwendig und können nur in relativ großen Zeitabständen durchgeführt werden. Es sind deshalb Verfahren zur Verifizierung z. B. der in den Laboratorien verwendeten Prüfapparaturen zu entwickeln. Die Entwicklung von Verifizierungsverfahren wird am Bespiel der Prüfmethode UN Test N.5 demonstriert. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Braunschweig, Germany DA - 21.05.2019 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung KW - Verifizierung PY - 2019 UR - https://www.ptb.de/cms/index.php?id=18763 DO - https://doi.org/10.7795/210.20190521E SP - 1 EP - 10 CY - Braunschweig AN - OPUS4-49495 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lüth, Peter A1 - Frost, K. A1 - Kurth, Lutz A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Schulte, Petra A1 - Uhlig, S. A1 - Zakel, S. T1 - CEQAT-DGHS Interlaboratory Test Programme for Chemical Safety - Need of Test Methods Validation N2 - Safety experts, manufacturers, suppliers, importers, employers or consumers must be able to rely on the validity of safety-related test methods and on correct test results and assessments in the laboratory. Via the eChemPortal lots of data from the REACH registration dossiers are available. However, the quality and correctness of the information remains in the responsibility of the data submitter. Unfortunately, we found more or less appropriate information on physicochemical properties and concluded that more quality or adequacy of any data submitted will be needed. Interlaboratory tests play a decisive role in assessing the reliability of test results. Interlaboratory tests on different test methods have been performed by Bundesanstalt für Materialforschung und –prüfung (BAM) and Physikalisch-Technische Bundesanstalt (PTB) in collaboration with the QuoData GmbH during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory tests. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method. In view of the interlaboratory test results the following conclusions can be drawn: • To avoid any discrepancy on classification and labelling of chemicals it should become state of the art to use validated test methods and the results accompanied by the measurement uncertainty. • A need for improvement is demonstrated for all examined test methods. Thus, interlaboratory tests shall initially aim at the development, improvement and validation of the test methods and not on proficiency tests. • The laboratory management and the practical execution of the tests need to be improved in many laboratories. • The term "experience of the examiner" must be seen critically: A "long experience with many tests" is not necessarily a guarantee for correct results. T2 - 16th International Symposium on Loss Prevention and Safety Promotion in the Process Industries and accompanying exhibition. Loss prevention 2019 CY - Delft, The Netherlands DA - 16.06.2019 KW - Dangerous goods KW - Hazardous substances KW - Round robin test KW - Interlaboratory comparison KW - Test method KW - Validation KW - Quality assurance PY - 2019 UR - https://www.aidic.it/cet/19/77/001.pdf SN - 978-88-95608-74-7 DO - https://doi.org/10.3303/CET1977001 SN - 2283-9216 VL - 77 SP - 1 EP - 6 PB - Italian Association of Chemical Engineering AN - OPUS4-49496 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ganose, Alex M. A1 - Sahasrabuddhe, Hrushikesh A1 - Asta, Mark A1 - Beck, Kevin A1 - Biswas, Tathagata A1 - Bonkowski, Alexander A1 - Bustamante, Joana A1 - Chen, Xin A1 - Chiang, Yuan A1 - Chrzan, Daryl C. A1 - Clary, Jacob A1 - Cohen, Orion A. A1 - Ertural, Christina A1 - Gallant, Max C. A1 - George, Janine A1 - Gerits, Sophie A1 - Goodall, Rhys E. A. A1 - Guha, Rishabh D. A1 - Hautier, Geoffroy A1 - Horton, Matthew A1 - Inizan, T. J. A1 - Kaplan, Aaron D. A1 - Kingsbury, Ryan S. A1 - Kuner, Matthew C. A1 - Li, Bryant A1 - Linn, Xavier A1 - McDermott, Matthew J. A1 - Mohanakrishnan, Rohith Srinivaas A1 - Naik, Aakash A. A1 - Neaton, Jeffrey B. A1 - Parmar, Shehan M. A1 - Persson, Kristin A. A1 - Petretto, Guido A1 - Purcell, Thomas A. R. A1 - Ricci, Francesco A1 - Rich, Benjamin A1 - Riebesell, Janosh A1 - Rignanese, Gian-Marco A1 - Rosen, Andrew S. A1 - Scheffler, Matthias A1 - Schmidt, Jonathan A1 - Shen, Jimmy-Xuan A1 - Sobolev, Andrei A1 - Sundararaman, Ravishankar A1 - Tezak, Cooper A1 - Trinquet, Victor A1 - Varley, Joel B. A1 - Vigil-Fowler, Derek A1 - Wang, Duo A1 - Waroquiers, David A1 - Wen, Mingjian A1 - Yang, Han A1 - Zheng, Hui A1 - Zheng, Jiongzhi A1 - Zhu, Zhuoying A1 - Jain, Anubhav T1 - Atomate2: Modular workflows for materials science N2 - High-throughput density functional theory (DFT) calculations have become a vital element of computational materials science, enabling materials screening, property database generation, and training of “universal” machine learning models. While several software frameworks have emerged to support these computational efforts, new developments such as machine learned force fields have increased demands for more flexible and programmable workflow solutions. This manuscript introduces atomate2, a comprehensive evolution of our original atomate framework, designed to address existing limitations in computational materials research infrastructure. Key features include the support for multiple electronic structure packages and interoperability between them, along with generalizable workflows that can be written in an abstract form irrespective of the DFT package or machine learning force field used within them. Our hope is that atomate2's improved usability and extensibility can reduce technical barriers for high-throughput research workflows and facilitate the rapid adoption of emerging methods in computational material science. KW - Automation KW - Materials design KW - DFT workflows KW - Phonons KW - Thermal conductivity KW - Bonding analysis PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635759 DO - https://doi.org/10.1039/d5dd00019j SN - 2635-098X SP - 1 EP - 30 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-63575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ganose, Alex M. A1 - Sahasrabuddhe, Hrushikesh A1 - Asta, Mark A1 - Beck, Kevin A1 - Biswas, Tathagata A1 - Bonkowski, Alexander A1 - Bustamante, Joana A1 - Chen, Xin A1 - Chiang, Yuan A1 - Chrzan, Daryl C. A1 - Clary, Jacob A1 - Cohen, Orion A. A1 - Ertural, Christina A1 - Gallant, Max C. A1 - George, Janine A1 - Gerits, Sophie A1 - Goodall, Rhys E. A. A1 - Guha, Rishabh D. A1 - Hautier, Geoffroy A1 - Horton, Matthew A1 - Inizan, T. J. A1 - Kaplan, Aaron D. A1 - Kingsbury, Ryan S. A1 - Kuner, Matthew C. A1 - Li, Bryant A1 - Linn, Xavier A1 - McDermott, Matthew J. A1 - Mohanakrishnan, Rohith Srinivaas A1 - Naik, Aakash A. A1 - Neaton, Jeffrey B. A1 - Parmar, Shehan M. A1 - Persson, Kristin A. A1 - Petretto, Guido A1 - Purcell, Thomas A. R. A1 - Ricci, Francesco A1 - Rich, Benjamin A1 - Riebesell, Janosh A1 - Rignanese, Gian-Marco A1 - Rosen, Andrew S. A1 - Scheffler, Matthias A1 - Schmidt, Jonathan A1 - Shen, Jimmy-Xuan A1 - Sobolev, Andrei A1 - Sundararaman, Ravishankar A1 - Tezak, Cooper A1 - Trinquet, Victor A1 - Varley, Joel B. A1 - Vigil-Fowler, Derek A1 - Wang, Duo A1 - Waroquiers, David A1 - Wen, Mingjian A1 - Yang, Han A1 - Zheng, Hui A1 - Zheng, Jiongzhi A1 - Zhu, Zhuoying A1 - Jain, Anubhav T1 - Correction: Atomate2: Modular workflows for materials science N2 - Correction for “Atomate2: modular workflows for materials science” by Alex M. Ganose et al., Digital Discovery, 2025, 4, 1944–1973, https://doi.org/10.1039/D5DD00019J. PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640297 DO - https://doi.org/10.1039/d5dd90036k SN - 2635-098X SP - 1 EP - 2 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-64029 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, C. A1 - Schierack, P. A1 - Gerber, U. A1 - Schröder, C. A1 - Choi, Youngeun A1 - Bald, Ilko A1 - Lehmann, W. A1 - Rödiger, S. T1 - Streptavidin Homologues for Applications on Solid Surfaces at High Temperatures N2 - One of the most commonly used bonds between two biomolecules is the bond between biotin and streptavidin (SA) or streptavidin homologues (SAHs). A high dissociation constant and the consequent high-temperature stability even allows for its use in nucleic acid detection under polymerase chain reaction (PCR) conditions. There are a number of SAHs available, and for assay design, it is of great interest to determine as to which SAH will perform the best under assay conditions. Although there are numerous single studies on the characterization of SAHs in solution or selected solid phases, there is no systematic study comparing different SAHs for biomolecule-binding, hybridization, and PCR assays on solid phases. We compared streptavidin, core streptavidin, traptavidin, core traptavidin, neutravidin, and monomeric streptavidin on the surface of microbeads (10–15 μm in diameter) and designed multiplex microbead-based experiments and analyzed simultaneously the binding of biotinylated oligonucleotides and the hybridization of oligonucleotides to complementary capture probes. We also bound comparably large DNA origamis to capture probes on the microbead surface. We used a real-time fluorescence microscopy imaging platform, with which it is possible to subject samples to a programmable time and temperature profile and to record binding processes on the microbead surface depending on the time and temperature. With the exception of core traptavidin and monomeric streptavidin, all other SA/SAHs were suitable for our investigations. We found hybridization efficiencies close to 100% for streptavidin, core streptavidin, traptavidin, and neutravidin. These could all be considered equally suitable for hybridization, PCR applications, and melting point analysis. The SA/SAH–biotin bond was temperature-sensitive when the oligonucleotide was mono-biotinylated, with traptavidin being the most stable followed by streptavidin and neutravidin. Mono-biotinylated oligonucleotides can be used in experiments with temperatures up to 70 °C. When oligonucleotides were bis-biotinylated, all SA/SAH–biotin bonds had similar temperature stability under PCR conditions, even if they comprised a streptavidin variant with slower biotin dissociation and increased mechanostability. KW - Biopolymers Probes KW - Hybridization KW - Fluorescence KW - Genetics PY - 2020 DO - https://doi.org/10.1021/acs.langmuir.9b02339 VL - 36 IS - 2 SP - 628 EP - 636 PB - American Chemical Society Publication CY - Washington AN - OPUS4-50357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kondo, M. A1 - Melzer, Michael A1 - Karnaushenko, D. A1 - Uemura, T. A1 - Yoshimoto, S. A1 - Aklyama, M. A1 - Noda, Y. A1 - Araki, T. A1 - Schmidt, O. G. A1 - Sekitani, T. T1 - Imperceptible magnetic sensor matrix system integrated with organic driver and amplifier circuits N2 - Artificial electronic skins (e-skins) comprise an integrated matrix of flexible devices arranged on a soft, reconfigurable surface. These sensors must perceive physical interaction spaces between external objects and robots or humans. Among various types of sensors, flexible magnetic sensors and the matrix configuration are preferable for such position sensing. However, sensor matrices must efficiently map the magnetic field with real-time encoding of the positions and motions of magnetic objects. This paper reports an ultrathin magnetic sensor matrix system comprising a 2 × 4 array of magnetoresistance sensors, a bootstrap organic shift register driving the sensor matrix, and organic signal amplifiers integrated within a single imperceptible platform. The system demonstrates high magnetic sensitivity owing to the use of organic amplifiers. Moreover, the shift register enabled real-time mapping of 2D magnetic field distribution. KW - Imperceptible electronics KW - Magnetic sensor system KW - Electronic skin KW - Organic electronics KW - Giant magnetoresistance PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503855 DO - https://doi.org/10.1126/sciadv.aay6094 SN - 2375-2548 VL - 6 IS - 4 SP - Paper eaay6094, 1 EP - 10 PB - American Association for the Advancement of Science AN - OPUS4-50385 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, Benita A1 - Pergantis, S. A. A1 - Esteban-Fernández, Diego A1 - Jakubowski, Norbert A1 - Günther, D. T1 - Investigation of a combined microdroplet generator and pneumatic nebulization system for rapid quantitative determination of metal-containing nanoparticles using ICP-MS N2 - In this work, a routinely applicable approach is presented to characterize metal NPs. Individual droplets generated from a microdroplet generator (MDG) were merged into an aerosol generated by a pneumatic nebulizer (PN) and introduced into an ICPMS. The MDG offers high transport efficiency of individual and discrete droplets and was therefore used to establish a calibration function for mass quantification of NPs which were introduced through the PN following the single particle procedure as described elsewhere. The major advantages of such a combined configuration include fast processing of large sample volumes, fast exchanges of different sample matrixes, and the calibration of the NP signal using traceable elemental standards, thus avoiding the need to use NP reference materials or other, not always thoroughly characterized, commercially available NPs. The transport efficiency of the sample introduction is calculated based on the fact that 100% of the calibrant reaches the plasma through the MDG, whereas for the PN a NP suspension containing a known number concentration is used. Alternatively, bulk analysis of the NP material allows transport efficiency determination without any additional information from reference NPs. With this method, we could determine the size of standard silver NPs at 60.4 ± 1.0 nm and 80.0 ± 1.4 nm, respectively, which agrees with the size ranges given by the supplier (60.8 ± 6.6 nm and 79.8 ± 5.4 nm). Furthermore, we were also able to determine the NPs number concentration of the sample (Ag/Au) with a deviation of 3.2% the expected value. KW - Nanoparticles KW - ICP-MS KW - Microdroplet generator PY - 2015 DO - https://doi.org/10.1021/acs.analchem.5b01604 SN - 0003-2700 SN - 1520-6882 VL - 87 IS - 17 SP - 8687 EP - 8694 PB - American Chemical Society CY - Washington, DC AN - OPUS4-34803 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, Stephan A1 - Hanelt, S. A1 - Canitz, C. A1 - Hoffmann, Holger A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Entwicklung monoklonaler Antikörper gegen Diclofenac N2 - Diclofenac (DCF) wird als nicht-steroidales, antientzündliches Arzneimittel gegen Fieber, Entzündungen, rheumatische Erkrankungen und Schmerzen eingesetzt. 70 % werden nach Einnahme wieder ausgeschieden. Aufgrund unvollständiger Elimination in den Kläranlagen lassen sich Rückstände im Trinkwasser und im Oberflächengewässer nachweisen. Diclofenac wird in der Umweltanalytik v.a. mittels GC-MS oder LCMS nachgewiesen. Bioanalytische Methoden machen sich die spezifische Antigen-Antikörper-Wechselwirkung zunutze, so z.B. Immunoassays. Die hierfür erforderlichen Antikörper werden durch Immunisierung mit einem Konjugat aus dem Analyten und einem Trägerprotein gewonnen. Die Kopplung kann direkt über die Carboxylfunktion von Diclofenac erfolgen. Um Abschirmungseffekte zu vermeiden, kann zwischen Protein und Analy1 ein Spacer sinnvoll sein. PY - 2015 SN - 1618-3258 SN - 1617-5301 IS - 4 SP - 107 EP - 109 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-35241 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bachmann, H. J. A1 - Bucheli, T. D. A1 - Dieguez-Alonso, A. A1 - Fabbri, D. A1 - Knicker, H. A1 - Schmidt, H.-P. A1 - Ulbricht, A. A1 - Becker, Roland A1 - Buscaroli, A. A1 - Buerge, D. A1 - Cross, A. A1 - Dickinson, D. A1 - Enders, A. A1 - Esteves, V.I. A1 - Evangelou, M. W. H. A1 - Fellet, G. A1 - Friedrich, K. A1 - Gasco Guerrero, G. A1 - Glaser, B. A1 - Hanke, U. M. A1 - Hanley, K. A1 - Hilber, I. A1 - Kalderis, D. A1 - Leifeld, J. A1 - Masek, O. A1 - Mumme, J. A1 - Paneque Carmona, M. A1 - Calvelo Pereira, R. A1 - Rees, F. A1 - Rombola, A. G. A1 - de la Rosa, J. M. A1 - Sakrabani, R. A1 - Sohi, S. A1 - Soja, G. A1 - Valagussa, M. A1 - Verheijen, F. A1 - Zehetner, F. T1 - Towards the standardization of biochar analysis: the COST action TD1107 interlaboratory comparison N2 - Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical–chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future. KW - Biochar KW - Analysis KW - Standardization KW - Ring test KW - Interlaboratory comparison PY - 2016 DO - https://doi.org/10.1021/acs.jafc.5b05055 SN - 0021-8561 SN - 1520-5118 VL - 64 IS - 2 SP - 513 EP - 527 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-35289 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Spallanzani, Roberta A1 - Koga, K. A1 - Cichy, S. A1 - Wiedenbeck, M. A1 - Schmidt, B. A1 - Oelze, Marcus A1 - Wilke, M. T1 - Lithium and boron difusivity and isotopic fractionation in hydrated rhyolitic melts N2 - Lithium and boron are trace components of magmas, released during exsolution of a gas phase during volcanic activity. In this study, we determine the difusivity and isotopic fractionation of Li and B in hydrous silicate melts. Two glasses were synthesized with the same rhyolitic composition (4.2 wt% water), having diferent Li and B contents; these were studied in difusion-couple experiments that were performed using an internally heated pressure vessel, operated at 300 MPa in the temperature range 700–1250 °C for durations from 0 s to 24 h. From this we determined activation energies for Li and B difusion of 57±4 kJ/mol and 152±15 kJ/mol with pre-exponential factors of 1.53 × 10–7 m2/s and 3.80× 10–8 m2 /s, respectively. Lithium isotopic fractionation during difusion gave β values between 0.15 and 0.20, whereas B showed no clear isotopic fractionation. Our Li difusivities and isotopic fractionation results difer somewhat from earlier published values, but overall confrm that Li difusivity increases with water content. Our results on B difusion show that similarly to Li, B mobility increases in the presence of water. By applying the Eyring relation, we confrm that B difusivity is limited by viscous fow in silicate melts. Our results on Li and B difusion present a new tool for understanding degassing-related processes, ofering a potential geospeedometer to measure volcanic ascent rates. KW - Hydrated silicate melts KW - Stable isotopes KW - Diffusion KW - Isotopic fractionation PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-554496 DO - https://doi.org/10.1007/s00410-022-01937-2 VL - 177 IS - 8 SP - 1 EP - 17 PB - Springer AN - OPUS4-55449 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Gödde, M. A1 - Salg, S. A1 - Erdt, René T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prag, Czechia DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 SN - 978-88-95608-88-4 DO - https://doi.org/10.3303/CET2290049 SN - 2283-9216 VL - 90 SP - 289 EP - 294 PB - AIDIC AN - OPUS4-55079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, S. T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prague, Czech Republic DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 AN - OPUS4-55080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -