TY - JOUR A1 - Scharf, Oliver A1 - Ihle, S. A1 - Ordavo, I. A1 - Arkadiev, V. A1 - Bjeoumikhov, A. A1 - Bjeoumikhova, S. A1 - Buzanich, Günter A1 - Gubzhokov, R. A1 - Günther, A. A1 - Hartmann, R. A1 - Kühbacher, M. A1 - Lang, M. A1 - Langhoff, N. A1 - Liebel, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Soltau, H. A1 - Strüder, L. A1 - Thünemann, Andreas A1 - Wedell, R. T1 - Compact pnCCD-based X-ray camera with high spatial and energy resolution: a color X-ray camera N2 - For many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented. The basic idea behind this so-called 'color X-ray camera' (CXC) is to combine an energy dispersive array detector for X-rays, in this case a pnCCD, with polycapillary optics. Imaging is achieved using multiframe recording of the energy and the point of impact of single photons. The camera was tested using a laboratory 30 µm microfocus X-ray tube and synchrotron radiation from BESSY II at the BAMline facility. These experiments demonstrate the suitability of the camera for X-ray fluorescence analytics. The camera simultaneously records 69696 spectra with an energy resolution of 152 eV for manganese Kα with a spatial resolution of 50 µm over an imaging area of 12.7 × 12.7 mm². It is sensitive to photons in the energy region between 3 and 40 keV, limited by a 50 µm beryllium window, and the sensitive thickness of 450 µm of the chip. Online preview of the sample is possible as the software updates the sums of the counts for certain energy channel ranges during the measurement and displays 2-D false-color maps as well as spectra of selected regions. The complete data cube of 264 × 264 spectra is saved for further qualitative and quantitative processing. KW - Color X-ray camera KW - X-ray fluorescence KW - pnCCD KW - Polycapillary optic KW - Synchrotron radiation PY - 2011 DO - https://doi.org/10.1021/ac102811p SN - 0003-2700 SN - 1520-6882 VL - 83 IS - 7 SP - 2532 EP - 2538 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23948 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Breuckmann, M. A1 - Hampel, S. A1 - Kreyenschmidt, M. A1 - Ke, X. A1 - Beuermann, S. A1 - Schafner, K. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. E. A. T1 - Characterization of Dimeric Vanadium Uptake and Species in Nafion™ and Novel Membranes from Vanadium Redox Flow Batteries Electrolytes N2 - A core component of energy storage systems like vanadium redox flow batteries (VRFB) is the polymer electrolyte membrane (PEM). In this work, the frequently used perfluorosulfonic-acid (PFSA) membrane Nafion™ 117 and a novel poly (vinylidene difluoride) (PVDF)-based Membrane are investigated. A well-known problem in VRFBs is the vanadium permeation through the membrane. The consequence of this so-called vanadium crossover is a severe loss of capacity. For a better understanding of vanadium transport in membranes, the uptake of vanadium ions from electrolytes containing Vdimer(IV–V) and for comparison also V(II), V(III), V(IV), and V(V) by both membranes was studied. UV/VIS spectroscopy, X-ray absorption near edge structure spectroscopy (XANES), total reflection X-ray fluorescence spectroscopy (TXRF), inductively coupled plasma optical emission spectrometry (ICP-OES), and micro X-ray fluorescence spectroscopy (microXRF) were used to determine the vanadium concentrations and the species inside the membrane. The results strongly support that Vdimer(IV–V), a dimer formed from V(IV) and V(V), enters the nanoscopic water-body of Nafion™ 117 as such. This is interesting, because as of now, only the individual ions V(IV) and V(V) were considered to be transported through the membrane. Additionally, it was found that the Vdimer(IV–V) dimer partly dissociates to the individual ions in the novel PVDF-based membrane. The Vdimer(IV–V) dimer concentration in Nafion™ was determined and compared to those of the other species. After three days of equilibration time, the concentration of the dimer is the lowest compared to the monomeric vanadium species. The concentration of vanadium in terms of the relative uptake λ = n(V)/n(SO3 ) are as follows: V(II) [λ = 0.155] > V(III) [λ = 0.137] > V(IV) [λ = 0.124] > V(V) [λ = 0.053] > Vdimer(IV–V) [λ = 0.039]. The results show that the Vdimer(IV–V) dimer Needs to be considered in addition to the other monomeric species to properly describe the transport of vanadium through Nafion™ in VRFBs. KW - MicroXRF KW - VRFB KW - PVDF-based membrane KW - UV/VIS KW - XANES KW - TXRF KW - ICP-OES PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530676 DO - https://doi.org/10.3390/membranes11080576 VL - 11 IS - 8 SP - 576 PB - MDPI AN - OPUS4-53067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Steglich, P. A1 - Mai, C. A1 - Bondarenko, S. A1 - Paul, Martin A1 - Weller, Michael G. A1 - Schrader, S. A1 - Mai, A. T1 - BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching N2 - Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. T2 - ATTRACT online Conference CY - Online meeting DA - 22.09.2020 KW - Silicon Photonics KW - Photonic Sensor KW - Photonic Integrated Circuits KW - Point-Of-Care-Diagnostics KW - CMOS KW - Microfluidics KW - Lab-on-a-chip KW - Ring resonator PY - 2020 UR - https://attract-eu.com/showroom/project/integration-of-biosensors-based-on-photonic-integrated-circuits-by-local-backside-etching-biopic/ SP - 1 EP - 5 AN - OPUS4-51735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lahiri, D. A1 - Sharma, S.M. A1 - Verma, A.K. A1 - Vishwanadh, B. A1 - Dey, G.K. A1 - Schumacher, G. A1 - Scherb, T. A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Banerjee, S. T1 - Investigation of short-range structural order in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 glasses, using X-ray absorption spectroscopy and ab initio molecular dynamics simulations N2 - Short-range order has been investigated in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 metallic glasses using X-ray absorption spectroscopy and ab initio molecular dynamics simulations. While both of these alloys are good glass formers, there is a difference in their glass-forming abilities (Zr41.5Ti41.5Ni17 > Zr69.5Cu12Ni11Al7.5). This difference is explained by inciting the relative importance of strong chemical order, icosahedral content, cluster symmetry and configuration diversity. KW - Multi-component alloy KW - Glass-forming ability KW - XAFS KW - Local structure KW - AIMD simulation PY - 2014 DO - https://doi.org/10.1107/S1600577514017792 SN - 0909-0495 SN - 1600-5775 VL - 21 IS - 6 SP - 1296 EP - 1304 PB - Blackwell Publishing CY - Oxford AN - OPUS4-31837 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martin, Tina A1 - Nordsiek, S. A1 - Weller, Andreas T1 - Low-frequency impedance spectroscopy of wood N2 - The method of low-frequency impedance spectroscopy has been successfully applied in Earth sciences to characterize soils and rocks. The method uses the diagnosing power of complex electrical resistivity in a frequency range between 1 mHz and 1 kHz. In our study, the potential of this method has been explored for the investigation of wood. We observed remarkable differences in the resulting spectra of complex resistivity for different European and Tropical tree species. The data processing of the acquired low-frequency impedance spectra yields integrating parameters. The comparison of the integrating parameters with the mean pore diameter that has been separately determined for the tropical tree species indicates clear correlations. An additional investigation has revealed remarkable difference in the complex resistivity spectra between oil bearing and non-oil bearing sandal wood. This result and the relations between electrical parameters and structural parameters of wood indicate the prospective potential of low-frequency impedance spectroscopy. KW - Holz KW - Spektroskopie KW - ZfP KW - SIP KW - Nondestructive KW - Low-frequency impedance spectroscopy KW - Spectral induced polarization PY - 2015 DO - https://doi.org/10.5171/2015.910447 SP - 1 EP - 9 PB - IBIMA Publ. AN - OPUS4-34811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Babutzka, Martin A1 - Reinemann, S. T1 - Electrochemical investigations regarding the influence of deformation-induced martensite on the corrosion behaviour of austenitic stainless steels N2 - Contents of deformation-induced martensite in the lattice structure of austenitic stainless steels lead to an either beneficial or detrimental change of mechanical and magnetic properties depending on the prospective application. Whereas these changes are well-known and investigated widely the influence of deformation-induced martensite on the corrosion behaviour is frequently an issue of scientific discussions. There are opposing opinions that depend on the type of corrosion mechanism being investigated for example regarding pitting corrosion resistance in Chloride containing media. In it is stated that pitting resistance is not influenced by deformationinduced martensite while in it is discussed that more pitting occurs on martensitic structure. The same conflictive opinions appear regarding active dissolution in acidic media or intergranular corrosion. In addition, when having deeper insight into literature it can be concluded that even the type of test method, i. e. dynamic or static testing, has a big influence on the obtained results concerning the influence of martensite in austenitic stainless steels. T2 - EUROCORR 2015 - European corrosion congress CY - Graz, Austria DA - 06.09.2015 KW - Deformation-induced martensite KW - Stainless steel KW - Electrochemical investigations PY - 2015 SP - paper 5_776 AN - OPUS4-34617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiggenhauser, Herbert A1 - Kind, Thomas A1 - Krause, Martin A1 - Schulze, S. A1 - Taffe, A. A1 - Trela, Christiane A1 - Wöstmann, Jens T1 - Praktische Anwendung zerstörungsfreier Prüfverfahren an Brücken N2 - Die drei Beispiele zerstörungsfreier Prüfungen an Spannbetonbrücken zeigen unterschiedliche Problemstellungen und deren Lösung mit unterschiedlichen Ansätzen. Allen drei Beispielen gemeinsam ist die Verwendung kommerzieller Geräte. Diese werden von verschiedenen Anbietern bereitgestellt. Eine weitere Gemeinsamkeit ist, dass die Grundgeräte durch zusätzliche Maßnahmen ergänzt. Erst dann ist der gewünschte Untersuchungserfolg sicher gestellt. Im ersten Beispiel wurde die vom Auftraggeber geforderte Präzision dadurch erreicht, dass systematische Voruntersuchungen stattfanden. Die Übertragung der Lokalisierung direkt auf die Betonoberfläche stellte sicher, dass keinen Informationsverluste an die nachfolgenden Aufgaben auftraten. Das zweite Beispiel zeigt den Nutzen von Automatisierung und Kombination von Verfahren. Damit können dem Auftraggeber die notwendigen Angaben über Einbauteile mit großer Detaitreue und leicht verständlicher Visualisierung aufbereitet werden. Der abschließende Bericht zeigt, wie vorhandene Auswertungen sinnvoll durch noch in der Forschung befindliche Ansätze bereichert werden. Insgesamt ist die zerstörungsfreie Prüfung in der Lage, an Brücken preisrelevante Fragestellungen zu lösen. Voraussetzung hierfür ist eine sorgfältig geplante Vorgehensweise und ein sicheres Verständnis der Grundlage der eingesetzten Geräte und Auswertungsschritte. T2 - 1. Brückenkolloquium - Beurteilung, Ertüchtigung und Instandsetzung von Brücken CY - Ostfildern/Stuttgart, Germany DA - 24.06.2014 PY - 2014 SP - Paper 00_08, 1 EP - 8 AN - OPUS4-31032 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Günther, Martin A1 - Levchik, S. V. A1 - Schartel, Bernhard T1 - Bubbles and collapses: Fire phenomena of flame-retarded flexible polyurethane foams N2 - Flexible polyurethane foams (FPUF) are easy to ignite and exhibit rapid flame spread. In this paper, the fire phenomena of two standard foam formulations containing tris (1,3-dichloro-2-propyl) phosphate (FR-2) and a halogen-freepoly (ethyl ethylene phosphate) (PNX), respectively, as flame retardants are compared. A multimethodological approach is proposed which combines standard fire tests as well as new investigatory approaches. The thermophysical properties of the foams were determined by thermogravimetric analysis (TG), reaction to small flames was studied by means of the limiting oxygen index (LOI) and UL 94 HBF test, and the burning behavior was investigated with the cone calorimeter. Further, temperature development in burning cone calorimeter samples was monitored using thermocouples, and rheological measurements were performed on pyrolyzed material, delivering insight into the dripping behavior of the foams. This paper gives comprehensive insight into the fire phenomena of flame-retarded FPUFs that are driven by the two-step decomposition behavior of the foams. LOI and UL 94 HBF tests showed a reduced flammability and reduced tendency to drip for the flame-retarded foams. TG and cone calorimeter measurements revealed that the two-step decomposition behavior causes two stages during combustion, namely structural collapse and pool fire. The flame-retardant mode of action was identified to take place primarily during the foam collapse and be based mainly on flame inhibition. However, some condensed-phase action was been measured, leading to significantly increased melt viscosity and improved dripping behavior for foams containing PNX. KW - Burning behavior KW - Flame retardant KW - Flexible PU foam PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-512145 DO - https://doi.org/10.1002/pat.4939 SN - 1042-7147 SN - 1099-1581 VL - 31 IS - 10 SP - 2185 EP - 2198 PB - Wiley Online Libary AN - OPUS4-51214 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vigna, L. A1 - Gottschalk, Martin A1 - Cacocciola, N. A1 - Verna, A. A1 - Marasso, S. L. A1 - Seeger, Stefan A1 - Pirri, C.F. A1 - Cocuzza, M. T1 - Flexible and reusable parylene C mask technology for applications in cascade impactor air quality monitoring systems N2 - The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates. KW - AEROMET II KW - Aerosol KW - Parylene C KW - Reference samples KW - Flexible shadow masks KW - Cascade impactor KW - Air quality monitoring KW - Micropatterning KW - Mask fabrication KW - Elemental aerosol analysis KW - TXRF PY - 2022 DO - https://doi.org/10.1016/j.mne.2022.100108 SN - 2590-0072 VL - 14 SP - 1 EP - 19 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-54252 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Gödde, M. A1 - Salg, S. A1 - Erdt, René T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prag, Czechia DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 SN - 978-88-95608-88-4 DO - https://doi.org/10.3303/CET2290049 SN - 2283-9216 VL - 90 SP - 289 EP - 294 PB - AIDIC AN - OPUS4-55079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, S. T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prague, Czech Republic DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 AN - OPUS4-55080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm der BAM in Kooperation mit QuoData und PTB N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und -prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung abzielen und nicht auf Leistungstests. T2 - 14. Kolloquium zur chemischen und physikalischen Sicherheitstechnik (BAM-PTB-Kolloquium) CY - Berlin, Germany DA - 14.06.2016 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2016 SN - 978-3-9817853-5-7 SN - 0938-5533 SP - 143 EP - 143 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38464 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit – Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - 13. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 16.11.2017 KW - Gefahrgut KW - Gefahrstoff KW - Ringversuch KW - Prüfmethode KW - Validierung KW - Qualitätssicherung PY - 2017 SN - 978-3-96057-032-5 SP - 1 EP - 13 CY - Köthen AN - OPUS4-43299 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Heyn, A. A1 - Rosemann, Paul A1 - Babutzka, Martin A1 - Bender, S. T1 - Electrochemical noise of unalloyed steel in mixtures of water-based binders and pigments N2 - The development of organic coatings for corrosion protection is an elaborate process with a multitude of often interminable investigations and tests of protection properties. Electrochemical methods support the processes of development to a great extent and help to understand mechanisms of action and failure. They are usually carried out on applied coating systems with a completed formulation. An examination possibility is presented in this publication that enables the characterization of waterbased coatings with different formulation variations in the liquid (aqueous) state with the aid of electrochemical noise technique. Thus, selection of binders, pigments, and other additives is supported essentially and made more efficient in a very early Phase of formulation development. The paper shows that a unique insight into the dynamic processes of a metal in contact with an aqueous coating dispersion is possible using the example of the development of zinc-free corrosion-inhibiting pigments for waterbased coatings. In addition, it is presented in which way the results correlate with the performance of applied coatings. KW - Organic coatings KW - Electrochemical noise KW - Corrosion KW - Corrosion protection KW - Corrosion protection pigments PY - 2017 DO - https://doi.org/10.1002/maco.201709671 SN - 0947-5117 SN - 1521-4176 VL - 68 IS - 12 SP - 1295 EP - 1301 PB - Wiley-VCH Verlag CY - Weinheim AN - OPUS4-43319 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - De la Rosa, J. M. A1 - Martin-Sanchez, Pedro Maria A1 - Santiago-Cortes, S. A1 - Hermosin, B. A1 - Knicker, H. A1 - Saiz-Jimenez, C. ED - De la Rosa, J. M. T1 - Structure of melanins from the fungi Ochroconis lascauxensis and Ochroconis anomala contaminating rock art in the Lascaux Cave N2 - Two novel species of the fungal genus Ochroconis, O. lascauxensis and O. anomala have been isolated from the walls of the Lascaux Cave, France. The interest in these fungi and their melanins lies in the formation of black stains on the walls and rock art which threatens the integrity of the paintings. Here we report solid-state cross polarization magic-angle spinning 13C and 15N nuclear magnetic resonance (NMR) spectroscopy and surface-enhanced Raman spectroscopy (SERS) of the melanins extracted from the mycelia of O. lascauxensis and O. anomala in order to known their chemical structure. The melanins from these two species were compared with those from other fungi. The melanins from the Ochroconis species have similar SERS and 13C and 15N NMR spectra. Their chemical structures as suggested by the data are not related to 3,4-dihydroxyphenylalanine, 5,6-dihydroxyindole or 1,8-dihydroxynaphthalene precursors and likely the building blocks from the melanins have to be based on other phenols that react with the N-terminal amino acid of proteins. The analytical pyrolysis of the acid hydrolysed melanin from O. lascauxensis supports this assumption. KW - Microbiology KW - Biodeterioration KW - Melanins KW - Fungi PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-435345 DO - https://doi.org/10.1038/s41598-017-13862-7 SN - 2045-2322 VL - 7 SP - 13441, 1 EP - 13441, 11 PB - Nature AN - OPUS4-43534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gómez-Fernández, S. A1 - Günther, Martin A1 - Schartel, Bernhard A1 - Corcuera, M. A. A1 - Eceiza, A. T1 - Impact of the combined use of layered double hydroxides, lignin and phosphorous polyol on the fire behavior of flexible polyurethane foams N2 - Flexible polyurethane foams with densities of 40 ± 2 kg m−3 were prepared by combining different ecofriendly fillers such as layered double hydroxides (LDH) and kraft lignin (a byproduct of the pulp and paper industry) with a phosphorous polyol (E560) in order to study their effect on the mechanical performance and fire behavior of the foams. Two series of foams were prepared, some containing lignin or LDH separately, and some with a combination of both: one of the series was prepared without E560 (0E foam series) and the other with 5 parts per hundred of E560 polyol (5E series). The use of fillers resulted in increased viscosity of the reactive mixture, requiring higher blowing agent content in order to hold the density of the foams constant. It was observed that urea phase segregation was favored in the series of 0E foams due to their lower viscosity than the 5E series. This had consequent effects on the resilience, compression force deflection and compression set of these foams. In terms of fire behavior it was observed that while the limiting oxygen index decreased, cone calorimeter results showed that the combination of lignin, LDH and E560 decreased the heat release of the foams. In addition, the combination of fillers and E560 contributed to increase the viscosity of the pyrolysis products, preventing the dripping of the molten polymer, which is a key factor in flame propagation towards adjacent objects in fire scenarios. KW - Ligning KW - Foam KW - Flexible polyurethane foam KW - Flame retardant PY - 2018 SN - 0926-6690 VL - 125 SP - 346 EP - 359 PB - Elsevier B.V. AN - OPUS4-45971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Ringversuchsprogramm für die Chemikaliensicherheit -Methodenvalidierung N2 - Bei der Bewertung der Verlässlichkeit der im Labor gewonnenen Prüfergebnisse spielen Ringversuche eine entscheidende Rolle. Die Bundesanstalt für Materialforschung und –prüfung (BAM) unterstützt deshalb den weiteren Ausbau des Ringversuchsprogramms des im Jahr 2007 gegründeten Kompetenzzentrums zur Qualitätssicherung für Prüfungen von Gefahrgütern und Gefahrstoffen auf physikalische Gefahren (Centre for quality assurance for testing of dangerous goods and hazardous substances, CEQAT-DGHS). Bei allen bisher untersuchten Prüfmethoden besteht ein Verbesserungsbedarf. Die RV müssen daher zunächst auf die Methodenentwicklung, -verbesserung und -validierung und auf die Bestimmung der Messunsicherheit der jeweiligen Prüfmethode abzielen und nicht auf Leistungstests. T2 - Behörden-Erfahungsaustausch CY - Berlin, Germany DA - 4. Juni 2018 KW - Prüfmethode KW - Methodenvalidierung KW - Gefahrgut KW - Gefahrstoff KW - Qualitätssicherung PY - 2018 AN - OPUS4-45297 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schnell, A. A1 - Rübner, Katrin A1 - Seher, Julia A1 - Müller, A. A1 - Liebezeit, S. A1 - Fenner, J. A1 - Martin, F. A1 - Pniok, N. T1 - REALight ‐ Leichtgranulate und REA‐Gips aus feinkörnigen sulfatbelasteten Bau‐ und Abbruchabfällen N2 - Ziel des Projekts REALight ist die Entwicklung einer Referenzanlage zur Herstellung von Leichtgranulaten (leichte Gesteinskörnungen) aus Bau‐ und Abbruchabfällen und zur Gipsrückgewinnung. Als Rohstoffe werden bisher ungenutzte oder auf niedrigem Niveau eingesetzte Bau‐ und Abbruchabfälle und industrielle Nebenprodukte verwendet. Als Produkte werden leichte Gesteinskörnungen hergestellt. Die Sulfatabtrennung durch eine thermische Zersetzung bildet die Grundlage für die zusätzliche Gewinnung von Rauchgasentschwefelungs‐Gips (REA‐Gips). Das Projekt wird im Rahmen der Fördermaßnahme „Ressourceneffiziente Kreislaufwirtschaft – Bauen und Mineralische Stoffkreisläufe (ReMin)” gefördert. ReMin ist eine Maßnahme zur Umsetzung des BMBF‐Forschungskonzepts „Ressourceneffiziente Kreislaufwirtschaft” als Teil der BMBF Strategie „Forschung für nachhaltige Entwicklung – FONA”. Ziel der Förderung ist es, den Ausbau der Kreislaufwirtschaft voranzutreiben. Im Mittelpunkt steht dabei die Bauwirtschaft mit ihrer hohen Nachfrage nach Rohstoffen und gleichzeitig großen Mengen an anfallenden mineralischen Abfällen. Am Projekt REALight sind 12 Partner aus verschiedenen Bereichen der Baustoffherstellung und ‐anwendung, Abfallaufbereitung, Verfahrenstechnik sowie Forschung und Entwicklung beteiligt. T2 - 21. Internationale Baustofftagung (ibausil) CY - Weimar, Germany DA - 13.09.2023 KW - Baustoffrecycling KW - Leichtgranulate KW - Gips KW - Leichte Gesteinskörnungen KW - Drehrohrofen KW - Recycling KW - Mauerwerkbruch KW - Infraleichtbeton PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-591708 DO - https://doi.org/10.1002/cepa.2840 SN - 2509-7075 VL - 6 IS - 6 SP - 530 EP - 536 PB - Ernst & Sohn CY - Berlin AN - OPUS4-59170 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hutt, S. A1 - Eisele, G. A1 - Krause, Martin T1 - Ultraschalltransmissionsanalyse am Cottaer Sandstein - Erste messtechnische Tastversuche N2 - Besonders beim Bauen im Bestand und der Bauwerkserhaltung werden zur Bestimmung des Tragvermögens von historischen, oft unter Denkmalschutz stehenden, natursteinernen Bauteilen Materialkennwerte benötigt. Die üblichen Verfahren mittels Probeentnahme am Objekt und Bestimmung der Kennwerte im Labor bedeuten bei Denkmälern einen massiven Eingriff und sollten vermieden werden. Vermehrt wird daher der Einsatz von zerstörungsfreien Untersuchungsmethoden erforscht und angewendet. Eine dieser Methoden stellt die Ultraschallprüfung dar. KW - Ultraschalltransmission KW - Naturstein KW - Uniaxialer Druck PY - 2015 SN - 0933-4017 VL - 2 SP - 22 EP - 29 PB - Callwey CY - München AN - OPUS4-32980 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schulze, S. A1 - Krause, Martin A1 - Mayer, K. A1 - Redmer, Bernhard A1 - Wiggenhauser, Herbert T1 - Grouting defects localized by ultrasonic testing including phase evaluation N2 - Grouting defects, e.g. in post-tensioned structures or piped anchors may be identified by ultrasonic imaging. Since several years experiences are carried out with false color displayed phase values, which enable distinct localization of ungrouted regions. In this contribution we report on progress in localizing grouting defects in tendon ducts, when they are only partly grouted and the unfilled part is not orientated into the direction of the measuring surface. This is frequently the case e.g. for box girder structures. Düring the project specimens containing different types of grouting faults are investigated in Order to optimize measuring and evaluation techniques. A handheld linear array System (commercially available) is applied for fast 2D-measurement and subsequent phase sensitive 3D-imaging (new Software development). In a large concrete wall specimen tendon ducts and real prestressing Systems containing grouting defects were built in. The ducts are partly covered by non prestressed reinforcement bars in order to investigate its disturbing influence. These included objects were investigated afterwards with the described methods. We report on large area measuring results, which were partly verified by y-radiography. In the frame of practical application results of measuring the position and extend of a blockade within a posttensioned structure are presen ted. T2 - SMT 2014 - NDE/NDT for highways and bridges - Structural materials technology CY - Washington, DC, USA DA - 25.08.2014 KW - Ultraschallecho-Verfahren KW - Spannbeton KW - Phasenauswertung PY - 2014 SN - 978-1-57117-342-3 SP - 321 EP - 328 AN - OPUS4-32846 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -