TY - JOUR A1 - MacLean, J. A1 - Mayanna, S. A1 - Benning, L. G. A1 - Horn, F. A1 - Bartholomäus, A. A1 - Wiesner, Yosri A1 - Wagner, D. A1 - Liebner, S. T1 - The terrestrial plastisphere: Diversity and polymer-colonizing potential of plastic-associated microbial communities in soil N2 - The concept of a ‘plastisphere microbial community’ arose from research on aquatic plastic debris, while the effect of plastics on microbial communities in soils remains poorly understood. Therefore, we examined the inhabiting microbial communities of two plastic debris ecosystems with regard to their diversity and composition relative to plastic-free soils from the same area using 16S rRNA amplicon sequencing. Furthermore, we studied the plastic-colonizing potential of bacteria originating from both study sites as a measure of surface adhesion to UV-weathered polyethylene (PE) using high-magnification field emission scanning electron microscopy (FESEM). The high plastic content of the soils was associated with a reduced alpha diversity and a significantly different structure of the microbial communities. The presence of plastic debris in soils did not specifically enrich bacteria known to degrade plastic, as suggested by earlier studies, but rather shifted the microbial community towards highly abundant autotrophic bacteria potentially tolerant to hydrophobic environments and known to be important for biocrust formation. The bacterial inoculates from both sites formed dense biofilms on the surface and in micrometer-scale surface cracks of the UV-weathered PE chips after 100 days of in vitro incubation with visible threadlike EPS structures and cross-connections enabling surface adhesion. High-resolution FESEM imaging further indicates that the microbial colonization catalyzed some of the surface degradation of PE. In essence, this study suggests the concept of a ‘terrestrial plastisphere’ as a diverse consortium of microorganisms including autotrophs and other pioneering species paving the way for those members of the consortium that may eventually break down the plastic compounds. KW - Soil microbial community KW - Polyethylene colonization KW - Plastic pollution PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542790 DO - https://doi.org/10.3390/microorganisms9091876 VL - 9 IS - 9 SP - 1 EP - 19 PB - MDPI CY - Basel AN - OPUS4-54279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Müller, B. A1 - de Lima Vasconcelos, S. A1 - Plehn, W. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Sattler, M. T1 - Präzisierung der Geruchsprüfung für Bauprodukte nach DIN ISO 16000-28 – Untersuchung von Vergleichsmaßstäben N2 - Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Geruch KW - Emission KW - Bauprodukte KW - VOC KW - Emissionskammer PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 214 EP - 223 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Brozowski, Frank A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte (Teil II): Anwendung eines Adapters und vereinfachtes Bewertungsverfahren T1 - Further Development of the Odour Measurement Method for Building Products (Part II) N2 - Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt. Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes. N2 - For technical improvement of sample presentation an adapter was developed to connect the emission test chamber with the evaluation funnel and thus enabling a more direct measurement. The analytical measurements demonstrate that the air has a very similar composition sampled at the funnel or in the emission test chamber. The results of the olfactory measurements show overall that the intensities determined using the adapter are often reported as lower. Further investigations have shown that air backflow via the funnel into the sample container of the adapter may be the cause. This has to be avoided in future. Another experimental series was carried out to reduce the measurement effort of evaluation of perceived intensity. Here application of the developed ‘greater than, or less than/equal to’ survey could be helpful. The results of the measurements in the air quality lab and in the frame of a round robin test indicate, that the survey leads to the same evaluation as the more complex determination of perceived intensity with standard method. KW - Geruchsmessung KW - VOC-Emission KW - Bauprodukte KW - Bewertungsverfahren PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549875 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 82 IS - 3-4 SP - 83 EP - 89 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-54987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Griebenow, Werner A1 - Werthmann, Barbara A1 - Treu, Dieter A1 - Hörn, K. A1 - Krause, S. T1 - Zur Identifizierung von Tinten auf alten Handschriften PY - 1983 SN - 0025-1445 SN - 0342-3719 VL - 89 IS - 3 SP - 208 EP - 212 PB - Callwey CY - München AN - OPUS4-38963 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stegemann, Bert A1 - Klemm, M. A1 - Horn, S. A1 - Woydt, Mathias T1 - Switching adhesion forces by crossing the metal-insulator transition in Magnéli-type vanadium oxide crystals N2 - Magnéli-type vanadium oxides form the homologous series VnO2n-1 and exhibit a temperature-induced, reversible metal–insulator first order phase transition (MIT). We studied the change of the adhesion force across the transition temperature between the cleavage planes of various vanadium oxide Magnéli phases (n = 3 ... 7) and spherical titanium atomic force microscope (AFM) tips by systematic force–distance measurements with a variable-temperature AFM under ultrahigh vacuum conditions (UHV). The results show, for all investigated samples, that crossing the transition temperatures leads to a distinct change of the adhesion force. Low adhesion corresponds consistently to the metallic state. Accordingly, the ability to modify the electronic structure of the vanadium Magnéli phases while maintaining composition, stoichiometry and crystallographic integrity, allows for relating frictional and electronic material properties at the nano scale. This behavior makes the vanadium Magnéli phases interesting candidates for technology, e.g., as intelligent devices or coatings where switching of adhesion or friction is desired. KW - Adhesion force KW - Atomic force microscopy KW - Magnéli phases KW - Metal-insulator transition KW - Vanadium oxide PY - 2011 DO - https://doi.org/10.3762/bjnano.2.8 SN - 2190-4286 VL - 2 SP - 59 EP - 65 CY - Frankfurt, M. AN - OPUS4-23155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, Birgit A1 - Müller, D. A1 - Horn, Wolfgang A1 - Panasková, J. A1 - Plehn, W. T1 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum T1 - Measurement and evaluation of odour emissions from building products for indoor usage N2 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum gewinnen vor allem durch den zunehmenden Bau energieeffizienter Gebäude an Bedeutung. Intensive und unangenehme Gerüche werden von Bewohnerinnen, Bewohnern und Angestellten nicht akzeptiert und können auf Dauer krank machen. Bislang stand noch kein allgemein anerkanntes Messverfahren zur Verfügung. Dieses wurde nun in Forschungsprojekten entwickelt, wobei auch konkrete Bewertungsvorschläge zur Zumutbarkeit von Gerüchen gemacht wurden. Das Verfahren ist an die Messung der Emissionen flüchtiger organischer Verbindungen aus Bauprodukten gekoppelt und nutzt Probanden, um die Geruchsstärke (Intensität) und den Geruchseindruck (Hedonik) zu ermitteln. In der Praxis wird das Verfahren nun an verschiedenen Stellen erprobt. Die Bewertung der Geruchsemissionen gibt der Industrie die Möglichkeit, geruchsarme Produkte zu gestalten. Die Kennzeichnung geruchsarmer Bauprodukte mit dem Umweltzeichen Blauer Engel erleichtert Verbraucherinnen und Verbrauchern die Orientierung beim Einkauf. N2 - Measuring and evaluating odour emissions from building products used in indoor spaces are becoming increasingly important for the construction of energy-efficient buildings. Intensive and unpleasant smells are not accepted by inhabitants and employees and may lead to negative health effects. Up to now a consistent measuring method for odour emissions has not been available. A measuring method and also concrete standards for the assessment of odours by using reasonableness of smells have now been developed in succeeding research projects. The procedure uses a panel of test persons to determine the strength (intensity) and impression (hedonic appraisal) of odour and is linked to the already well established measurement of the emission of volatile organic compounds from building products. At the Moment the new procedure is tested in practice at different laboratories. Evaluating odour emissions helps manufacturers to develop products with low or very low odour emissions. The labeling of low-odour Building products with the environmental label Blue Angel gives consumers an orientation for purchase. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen PY - 2011 SN - 2190-1120 SN - 2190-1147 VL - 4 SP - 50 EP - 58 PB - BfS CY - Berlin AN - OPUS4-25210 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steger, S. A1 - Horn, Wolfgang A1 - Eggert, G. A1 - Krekel, C. T1 - Are cellulose ethers safe for the conservation of artwork? New insights in their VOC activity by means of Oddy testing N2 - Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde. KW - Cellulose ether KW - Corrosion KW - Oddy test KW - VOC KW - BEMMA PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547591 DO - https://doi.org/10.1186/s40494-022-00688-4 SN - 2050-7445 VL - 10 IS - 1 SP - 1 EP - 12 PB - Springer Open AN - OPUS4-54759 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Further Development of Odour Testing of Building Products – Sample Presentation and Evaluation of Perceived Intensity N2 - Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020. In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results. T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 CY - Online meeting DA - 21.06.2021 KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC KW - Perceived Intensity PY - 2021 SN - 978-82-536-1728-2 VL - 2021 SP - 1 EP - 4 PB - SINTEF Books CY - Oslo, Norwegen AN - OPUS4-54574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - New developments in odour testing: Adapter connects emission test chamber and funnel N2 - Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented. The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test. The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far. T2 - CLIMA 2022 The 14th REHVA HVAC World Congress CY - Rotterdam, The Netherlands DA - 22.05.2022 KW - Perceived Intensity KW - Emissionen KW - Geruch KW - Bauprodukte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556192 DO - https://doi.org/10.34641/clima.2022.168 SP - 1 EP - 5 PB - TU Delft open CY - Delft, Niederlande AN - OPUS4-55619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Odour testing of building products: Examinations for an on-going development of the test standard ISO 16000-28 N2 - VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Building material KW - Odour KW - Perceived intensity KW - VOC KW - Emission test chamber PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580070 SP - 345 EP - 352 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Brandt, S. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Möglichkeiten und Grenzen der Bewertung und Kennzeichnung geruchsarmer Bauprodukte und Einrichtungen T2 - VDI-Tagung CY - Bad Kissingen, Deutschland DA - 2007-11-13 KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Blauer Engel PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 181 EP - 191 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16321 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Däumling, C. A1 - Brenske, K.-R. A1 - Crump, D. A1 - Funch, L. W. A1 - Hansen, K. A1 - Horn, Wolfgang A1 - Kephalopoulos, S. A1 - Maupetit, F. A1 - Saarela, K. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of material emission labelling schemes in the EU T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Labelling scheme KW - Evaluation system KW - Material emission KW - Harmonisation PY - 2008 SP - 1 AN - OPUS4-18046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kirchner, D. A1 - Jann, Oliver A1 - Kemmlein, S. A1 - Kalus, Sabine A1 - Süßmilch, C. T1 - European interlaboratory study for sampling VOC emissions - Step 1 - Liquid samples added on Tenax tubes T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - ISO 16000-6 KW - VOC analysis KW - Interlaboratory study KW - Emission tests KW - Building material PY - 2008 IS - Paper 226 SP - 1 AN - OPUS4-18048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kephalopoulos, S. A1 - Däumling, C. A1 - Crump, D. A1 - Funch, L. W. A1 - Horn, Wolfgang A1 - Maupetit, F. A1 - Saarela, K. A1 - Säteri, J. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of indoor material emission labelling schemes in the EU - VOC workshop T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Labelling schemes KW - Indoor material emissions KW - VOC KW - Framework KW - Harmonisation PY - 2009 IS - Paper 635 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19925 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Howard-Reed, C. A1 - Liu, Z. A1 - Cox, S. A1 - Little, J. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Persily, A. T1 - Inter-laboratory study approach to validate the performance of a prototype reference material for product emissions testing N2 - Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Test method validation KW - Volatile organic compounds KW - Product certification PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, B. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte T1 - Further development of the odour measurement method for building products N2 - Bauprodukte und Einrichtungsgegenstände für Innenräume, wie Bodenbeläge und Wandpaneele, sollen das Wohlbefinden und die Gesundheit der Raumnutzerinnen und -nutzer nicht durch das Ausdünsten von Geruchsstoffen stören. Mit der Geruchsprüfung nach ISO 16000-28 „Innenraumluft - Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ wird der Produktgeruch zu einer messbaren Größe. So kann z. B. die empfundene Intensität, also die Stärke eines Geruchseindruckes, mit Hilfe eines Vergleichsmaßstabes von Probandinnen und Probanden ermittelt werden. Im hier vorgestellten Projekt werden Vorschläge zur Weiterentwicklung der Methode vorgestellt, um im Ergebnis die Reproduzierbarkeit der Messergebnisse weiter zu verbessern. Dabei werden vor allem das Probenpräsentationssystem und die Bewertungsmethodik für die empfundene Intensität bei der Bewertung von Bauprodukten gemäß AgBB-Schema betrachtet, da diese einen wesentlichen Einfluss haben. N2 - Emissions or odours occurring from building products and furnishings for interiors, like floor coverings or wall panels, should not have a negative impact on well-being or health. Odours can be measured applying the standard ISO 16000-28 „Indoor air - Determination of odour emissions from building products using test chambers” It describes among other procedures the assessment of perceived intensi-ty with comparative scale by a group of panellists. In the study presented here, proposals for further technical development of the methodology are discussed to increase the reproducibility of measurement results. The sampling procedure and evaluation method of perceived intensity are investigated in particular because they have a major influence at the assessment of construction products applying the procedure of the Committee for Health Evaluation of Building Products. KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527458 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 81 IS - 3-4 SP - 151 EP - 155 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-52745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lasota, S. A1 - Horn, M. A1 - Noll, M. A1 - Stephan, Ina A1 - Otto, W. T1 - Copper in wood preservatives delayed wood decomposition and shifted soil fungal but not bacterial community composition N2 - Copper-based fungicides are routinely used for wood and plant protection, which can lead to an enrichment of copper-tolerant microbial communities in soil. To investigate the effect of such wood preservatives on the soil fungal and bacterial community compositions, five different vineyard and fruit-growing soil environments were evaluated using incubation studies over time. Pine sapwood specimens were impregnated with either water or different biocide treatment solutions containing a mixture of copper, triazoles, and quaternary ammonium compounds (CuTriQAC), a mixture of triazoles and quaternary ammonium compounds (TriQAC), or copper alone (Cu). Specimens were incubated in soil from each sample site for 8, 16, 24, and 32 weeks. The effects of preservative treatment on the modulus of elasticity (MOE) of the wood specimens and on the soil fungal as well as bacterial community composition at the soil-wood interface were assessed by quantitative PCR and amplicon sequencing of the fungal internal transcribed spacer (ITS) region and bacterial 16S rRNA gene. Specimens impregnated with CuTriQAC and Cu showed decreased MOE and reduced fungal and bacterial copy numbers over time compared to those impregnated with water and TriQAC. Fungal but not bacterial community composition was significantly affected by wood preservative treatment. The relative abundance of members of the family Trichocomaceae compared to other genera increased in the presence of the Cu and CuTriQAC treatments at three sites, suggesting these to be Cu-tolerant fungi. In conclusion, the copper-containing treatments resulted in marginally increased MOE, lowered microbial gene copy numbers compared to those in the TriQAC and water treatments, and thus enhanced wood protection against soil microbial wood degradation KW - 16S rRNA gene KW - ITS region KW - Amplicon sequencing KW - Community composition KW - Copper-based wood preservatives KW - Soil incubation study PY - 2019 DO - https://doi.org/10.1128/AEM.02391-18 SN - 1098-5336 SN - 0099-2240 VL - 85 IS - 4 SP - e02391-18, 1 EP - 13 PB - American Society for Microbiology CY - Washington, DC AN - OPUS4-47370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brosig, L. A1 - Müller, B. A1 - Mertes, A. A1 - de Lima Vasconcelos, S. T1 - Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude – Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht N2 - Menschen, die in der gemäßigten Klimazone leben, verbringen bis zu 90% ihres Lebens in Innenräumen. Deshalb hat das Innenraumklima eine sehr große Bedeutung für deren Wohlergehen, Gesundheit und Leistungsfähigkeit. In Deutschland wird ca. 40% der eingesetzten Primärenergie für das Heizen, Kühlen und Klimatisieren der Innenräume verwendet. Das Forschungsvorhaben hat eine Laufzeit vom Oktober 2013 bis März 2017. Es wird in Kooperation mit der Bundesanstalt für Materialforschung und –prüfung (BAM) und der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) durchgeführt. Die HTW Berlin koordiniert das Projekt. Die Rheinisch-Westfälische Technische Hochschule Aachen (RWTH) wird teilweise über einen Auftrag in das Projekt integriert. Ziel des Projektes ist es Baustoffe auf ihre Geruchsemissionen zu untersuchen, um Bauprodukte mit niedrigen Emissionen und Gerüchen identifizieren zu können. Den Verbraucherinnen und Verbrauchern wird somit die Möglichkeit gegeben emissions- und geruchsarme Baustoffe zu wählen. Die Aufgabenstellung des Projektes ist nachfolgend aufgeführt: Arbeitspaket 1: Geruchsmessung bei Produkten mit dem Blauen Engel (siehe Kapitel 4 und 5); Arbeitspaket 2: Untersuchung von Vergleichsmaßstäben (siehe Kapitel 6); Arbeitspaket 3: Untersuchung der Linearität der Acetonskala (siehe Kapitel 7); Arbeitspaket 4: Erstellung einer Produktdatenbank (siehe Kapitel 8). Die Geruchsuntersuchung ist in den Vergabekriterien für den „Blauen Engel“ für textile Bodenbeläge (RAL UZ-128) eingebunden worden. Aus den weiteren Untersuchungen sind für die Normung wichtige Erkenntnisse erarbeitet worden. KW - VOC Emissionen KW - Geruch KW - Bewertung KW - Innenraumluftqualtität KW - Bodenbeläge PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487223 UR - https://www.umweltbundesamt.de/publikationen/emissions-geruchsarme-bauprodukte-fuer UR - https://www.umweltbundesamt.de/sites/default/files/medien/1410/publikationen/2019-08-20-texte_92-2019_emissionsarme-bauprodukte.pdf SN - 1862-4804 VL - 92 SP - 1 EP - 106 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-48722 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Lima Vasconcelos, S. A1 - Sattler, M. A1 - Müller, B. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The Influence of textile floor coverings on the indoor air quality N2 - Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge). T2 - Clima 2019 Congress CY - Bucharest, Romania DA - 26.05.2019 KW - VOC Emissionen KW - Geruch KW - Bodenbelag KW - AgBB Bewertung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487341 DO - https://doi.org/10.1051/e3sconf/201911102051 SN - 2267-1242 VL - 111 SP - 02051-1 EP - 02051-6 PB - EDP Sciences AN - OPUS4-48734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klinge, A A1 - Mönig, J A1 - Ziegert, C A1 - Richter, Matthias A1 - Kalbe, Ute A1 - Horn, Wolfgang A1 - Röhlen, U A1 - Rauscher, S A1 - Roswag-Klinge, E T1 - upMIN 100 – upcycling of mineral construction and demolition waste to substitute natural aggregates in earthen building materials N2 - The construction sector is one of the most resource-intensive sectors in Germany and is responsible for 40 % of CO2 emissions. Around 517 million tons of mineral raw materials are required annually for the construction of buildings in Germany. At the same time, mineral construction waste was the largest material flow at 229.3 million tons (2020). The rates of construction and demolition waste (CDW) recycling have increased since 2000, especially for mineral waste. Nevertheless, the majority of recycled aggregates are used in technically largely unregulated applications (e.g. road construction). This downcycling leads to a loss of valuable resources for technically and economically valuable applications. The upMIN 100 research project is investigating the question of whether and to what extent recycled CDW is suitable as an additive an binder in earthen building materials. The focus is placed on grain sizes of < 2 mm, which are currently predominantly landfilled, as there are at present no regulations for their use in building products. The soil matrix of earthen building materials however, naturally contains of different grain sizes, whith < 2mm – 0,063 for aggregates and < 0.063 mm as a binder. Therefore, the focused grain sizes (sand, clay and silt) could have a high usage potential. In order to enable the use of CDW, the technical feasibility must be ensured, quality requirements for source materials (e.g. threshold values for pollutants in terms of health and environmental compatibility and hazardous substances) and permissible proportions of recycled aggregates must be defined. Two different building material developments (earth blocks and -plaster)were used to assess both, the technical feasibility as well the pollutant content of the recycled aggregate and its final emissions into the indoor air. For both materials two mixtures could be established, that also meet the mechanical specifications according to the DIN standard, such as the compressive strength. A method was developed to design material mixtures with a high amount of CDW that comply with the defined limit values. The mixtures reached a recycling rate of 28 % with high mechanical properties and 70 % with minimum strength requirements. KW - Mineral waste KW - Upcycling KW - Earthen building product KW - Circular construction PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652831 DO - https://doi.org/10.1088/1755-1315/1554/1/012084 SN - 1755-1307 VL - 1554 IS - 1 SP - 1 EP - 9 PB - IOP Publishing AN - OPUS4-65283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -