TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 18. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - MKW KW - PAK KW - Gesamtcyanid KW - Spurenelemente KW - Proficiency testing KW - Soil KW - TPH KW - PAH KW - Total cyanide KW - Trace elements PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-357399 SP - 1 EP - 226 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35739 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Becker, Roland A1 - Koch, Matthias A1 - Buge, Hans-Georg A1 - Nehls, Irene T1 - Entwicklung eines Referenzverfahrens zur Quantifizierung von polychlorierten Biphenylen (PCB) in Kunststoffgranulaten N2 - Im Rahmen eines vom Bundesministerium für Wirtschaft und Arbeit (BMWA) geförderten Projektes wird in Kooperation mit dem Verband deutscher Metallhändler (VDM) ein Verfahren zur Quantifizierung der PCB-Kongenere 28, 52, 101, 138, 153, 180 im Gehaltsbereich von 0,1 bis 20 mg in Kunststoffabfällen aus dem Altkabelrecycling entwickelt und validiert. Dazu werden repräsentative Referenzmaterialien für die Laboranalytik aus Granulaten verschiedener Kabelzerlegeprozesse hergestellt und charakterisiert. Die Methodenentwicklung umfasst mahl-, sieb- und schüttguttechnologische Aspekte sowie den Vergleich unterschiedlicher Extraktionsverfahren und chromatographischer Bedingungen. Das validierte Verfahren sieht die Mahlung der technischen Probe auf eine Kornobergrenze von 0,50 mm gefolgt von Extraktion mit einem unpolaren Lösungsmittel bei einer Einwaage von 4 g und gaschromatographischer Bestimmung vor. Die Bestimmungsgrenzen liegen zwischen 0,01 und 0,08 mg/kg. Bei sorgfältiger Wahl der chromatographischen Bedingungen sind Elektroneneinfang- und massenselektive Detektion (MS) gleichwertig. In Gegenwart größerer Mengen bestimmter Komponenten, die in einigen Kabeln enthalten sind, kann der Einsatz eines MS von Vorteil sein. Drei Referenzmaterialien mit Gehalten der genannten Kongenere zwischen 0,1 bis 5 mg/kg werden in einem abschließenden Ringversuch zur Validierung dieser Methode mit 23 ausgewählten Laboratorien eingesetzt. Dabei ergeben sich für die Quantifizierung dieser Kongenere relative Vergleichsstandardabweichungen zwischen 15 und 33 %. Das Verfahren wird in die europäische Normung (CEN 292 „Characterisation of Waste“) eingebracht. T3 - BAM Forschungsberichtreihe - 270 PY - 2005 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1810 SN - 978-3-86509-320-5 SN - 0938-5533 VL - 270 SP - 1 EP - 107 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-181 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Buttler, Sabine A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 23. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polyzyklische aromatische Kohlenwasserstoffe (PAK) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Sediment und Gesamtcyanid in Boden. KW - Gesamtcyanid KW - Boden KW - Eignungsprüfung KW - MKW KW - PAK KW - Schwermetalle PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-473403 SP - 1 EP - 261 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-47340 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 21. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - PAK KW - MKW KW - Spurenelemente KW - Gesamtcyanid KW - Proficiency testing KW - Soil KW - PAH KW - TPH KW - Trace elements KW - Total cyanide PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355586 SP - 1 EP - 234 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35558 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Win, Tin T1 - Ableitung validierter Probenahme und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von Leichtflüchtigen Chlorierten Kohlenwasserstoffen (LCKW) im Grundwasser im Rahmen von Altlastenuntersuchungen N2 - Im vorliegenden Forschungsbericht werden die Ergebnisse zum LFP Projekt „Ableitung validierter Probenahme- und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von LCKW im Grundwasser im Rahmen von Altlastenuntersuchungen“ (Länderfinanzierungsprogramm, Projekt B2/08, Laufzeit vom 01.09.2008 – 31.08.2009) zusammengefasst. Es werden verschiedene Verfahren der Probenahme und Analytik zur Bestimmung von Wasserstoff, Methan, Ethen und Vinylchlorid (VC) im Grundwasser untersucht und validiert. Für die Probenahme werden folgende Ansätze beschrieben und diskutiert: i. aktive Probenahme: Pumpprobe und Probenahme von in Grundwasser gelösten Gasen in Gasbeprobungsrohren (Gasmaus) ii. passive Probenahme: Diffusionsprobenahme in Polyethylenbeuteln (PDB) und Kunststoffspritzen als Diffusionssammler für gelöste Gase Der Einsatz aktiver (Pumpprobenahme, Schöpfprobenahme) und passiver (Diffusionsprobenahme) Probenahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probenahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probenahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Die chromatographischen Verfahren zur Bestimmung der Analyte werden umfänglich validiert und mit anderen geeigneten Analysenverfahren verglichen: I. Headspace-GC-FID zur Bestimmung von Methan, Ethen und VC aus der wässrigen Probenmatrix der Pumpprobe (i.) und des PDB (ii.) II. Direktinjektion-GC-PDD zur Bestimmung von Wasserstoff aus den gesammelten Gasproben der Gasmaus (i.) und der Kunststoffspritzen (ii.) Für die Bestimmung von Ethen und VC in Grundwasserproben (I.) werden Bestimmungsgrenzen von 0,1 μg/L erreicht. Methan kann aus wässrigen Proben nur ab 5 μg/L quantifiziert werden. Mit den Verfahren zur Bestimmung von Methan aus der Gasmaus (i.-II.) werden 0,1 μg/L im Grundwasser erreicht. Die Bestimmung von im Grundwasser gelösten Wasserstoff (II.) ist bis zu einer Konzentration von 1 nM möglich. Die Reproduzierbarkeit für die Bestimmung von Wasserstoff in Grundwasser liegt konzentrationsabhängig zwischen 10 bis 20% bei der aktiven Probenahme (i.-II.) und 10 bis 70% bei der passiven Probenahme (ii.-II.). Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probenahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring-Ergebnissen sollten von Ingenieurbüros und zuständige Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden. T3 - BAM Forschungsberichtreihe - 290 PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1610 SN - 978-3-9813346-5-4 SN - 0938-5533 VL - 290 SP - 1 EP - 121 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-161 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scholz, Philipp A1 - Wachtendorf, Volker A1 - Elert, Anna Maria A1 - Falkenhagen, Jana A1 - Becker, Roland A1 - Hoffmann, Katrin A1 - Resch-Genger, Ute A1 - Tschiche, Harald A1 - Reinsch, Stefan A1 - Weidner, Steffen ED - Scholz, Philipp T1 - Analytical toolset to characterize polyurethanes after exposure to artificial weathering under systematically varied moisture conditions N2 - Polyether and -ester urethanes (PU) were exposed to artificial weathering at 40 °C and artificial UV radiation in a weathering chamber. In 3 parallel exposures, humidity was varied between dry, humid, and wet conditions. Material alteration was investigated by various analytical techniques like size exclusion chromatography (SEC), liquid chromatography-infrared spectroscopy (LC-FTIR), thermal-desorption gas chromatography-mass spectrometry (TD-GC-MS), fluorescence mapping and dynamic mechanical analysis (DMA). Our results show that depending on the weathering conditions, different degradation effects can be observed. By means of SEC an initial strong decrease of the molar masses and a broadening of the mass distributions was found. After a material dependent time span this was followed by a plateau where molar mass changes were less significant. A minor moisture-dependent degradation effect was only found for polyester PU. Fluorescence measurements on two materials revealed an increase in the luminescence intensity upon weathering process reaching a saturation level after about 500 h. The changes in the optical properties observed after different exposure conditions and times were very similar. The TD-GC-MS data showed the fate of the stabilizers and antioxidant in the course of weathering. LC-FTIR measurements revealed a change in peak intensities and the ratio of urethane and carbonyl bands. KW - Polyurethane KW - Artificial weathering KW - Moisture KW - Crosslinking KW - Degradation PY - 2019 UR - https://www.sciencedirect.com/science/article/pii/S0142941819303708 DO - https://doi.org/10.1016/j.polymertesting.2019.105996 SN - 0142-9418 VL - 78 SP - 105996, 1 EP - 9 PB - Elsevier CY - Amsterdam AN - OPUS4-48625 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Maul, Ronald A1 - Nehls, Irene T1 - Hexabromocyclododecane enantiomers: microsomal degradation and patterns of hydroxylated metabolites N2 - The degradation of the enantiomers of α-, β-, and γ-hexabromocyclododecane (HBCD) by phase I metabolism was investigated using induced rat liver microsomes. HBCD isomers were quantified using HPLC-MS/MS (ESI-) after separation on a combination of a reversed phase and a chiral analytical column. The degradation of all six isomers followed first-order kinetics and the estimated half-lives ranged from 6.3 min for both β-HBCD enantiomers to 32.3 min in case of (+)-γ-HBCD. (+)-α- and (–)-γ-HBCD displayed significantly shorter half-lives than their corresponding antipodes. It could be shown that this degradation led to a significant enrichment of the first eluting enantiomers (–)-α- and (+)-γ-HBCD. Individual patterns of mono- and dihydroxylated derivatives obtained from each α- and γ-HBCD enantiomer were seen to be distinctly characteristic. The patterns of monohydroxylated HBCD derivatives detected in liver and muscle tissues of pollack, mackerel and in herring gull eggs were largely similar to those observed in the in vitro experiments with rat liver microsomes. This enabled individual hydroxy-HBCDs to be assigned to their respective parent HBCD enantiomers. KW - Brominated flame retardant KW - Cytochromes KW - Phase I metabolism KW - Hydroxylation KW - HPLC-MS/MS PY - 2011 DO - https://doi.org/10.1021/es1039584 SN - 0013-936X SN - 1520-5851 VL - 45 IS - 9 SP - 3938 EP - 3944 PB - ACS Publ. CY - Washington, DC AN - OPUS4-23837 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Nehls, Irene A1 - Leschber, G. A1 - Frese, S. A1 - Walles, T. A1 - Neudecker, J. T1 - Comparison of volatile organic compounds from lung cancer patients and healthy controls—challenges and limitations of an observational study N2 - The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates. KW - Breath KW - Volatile organic compounds KW - Marker KW - Cancer KW - Gas chromatography KW - Solid phase microextraction KW - Volatilome PY - 2016 DO - https://doi.org/10.1088/1752-7155/10/4/046007 SN - 1752-7155 SN - 1752-7163 VL - 10 IS - 4 SP - Article 046007, 1 EP - 17 PB - IOP Publishing AN - OPUS4-37801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Schwarzer, Martin A1 - Becker, Roland A1 - Kuhnhardt, Claus A1 - Nehls, Irene T1 - Methodenvergleich zur Bestimmung von extrahierbaren organischem Halogen (EOX) in Bodenproben N2 - Ziel der vorliegenden Untersuchungen, die im Rahmen einer Diplomarbeit der Fachhochschule Lausitz/Senftenberg an der BAM durchgeführt wurden, war ein Vergleich unterschiedlicher Extraktionsverfahren für die Bestimmung von extrahierbarem organischem Halogen (EOX) in Bodenproben. EOX ist ein für die rasche Bewertung der Organochlor- Belastung kontaminationsverdächtiger Flächen wertvoller Summenparameter, der sämtliche mit organischen Lösungsmittel extrahierbare Organohalogenverbindungen erfasst. Gegenwärtig existiert jedoch kein für die Bodenanalytik genormtes Verfahren für die Durchführung von EOX-Bestimmungen. Daher wird in der Praxis auf das für Schlämme und Sedimente entwickelte Verfahren nach DIN 38414 S17 (1990) zurückgegriffen, so auch in der Bundesbodenschutz- und Altlasten-Verordung (BBodSchV). Literaturangaben und Erfahrungen mit der Wiederfindungsrate polarer Extraktionsmittel und moderner Extraktionsverfahren bei Organochlorpestiziden, die eine bedeutende Quelle für EOX in Schlämmen und Böden darstellen, lassen vermuten, dass das genannte Normverfahren systematisch zu Unterbefunden neigen könnte. Für die Untersuchungen wurden an der BAM entwickelte Boden-Referenzmaterialien mit "natürlicher", über jahrzehntelangen Eintrag entstandener DDT- und Lindan-Belastung verwendet. Neben den klassischen Extraktionsverfahren nach Soxhlet kamen die ultraschallunterstützte Extraktion, die Mikrowellen- und die beschleunigte Lösungsmittelextraktion (ASE) jeweils mit Lösungsmitteln unterschiedlicher Polarität zum Einsatz. Extraktionsausbeuten und Wiederholpräzision der einzelnen Varianten wurden verglichen und vor dem Hintergrund der Ergebnisse unabhängiger Verfahren wie der gaschromatographischen Bestimmung der einzelnen Organochlorverbindungen bewertet. Die Polarität des Extraktionsmittels weist auch bei trockenen Böden den größten Einfluss auf die Extraktionsausbeuten der in den untersuchten Proben enthaltenen Organochlorverbindungen auf. Die Mischung Hexan/Aceton (1:1), die sich für die Extraktion verschiedener organischer Parameter bewährt hat, ist hinsichtlich der EOX-Analytik der existierenden Norm überlegen. T3 - BAM Forschungsberichtreihe - 263 PY - 2003 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1884 SN - 978-3-86509-083-4 SN - 0938-5533 VL - 263 SP - 1 EP - 64 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Müller-Belecke, A. A1 - Bremser, Wolfram A1 - Jung, Christian A1 - Nehls, Irene T1 - HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers KW - Enantiomer-specific determination KW - HPLC-MS/MS KW - Brominated flame retardant KW - Fish feeding experiment KW - Enantiomer fraction KW - Bioisomerization PY - 2010 DO - https://doi.org/10.1021/jf101469q SN - 0021-8561 SN - 1520-5118 VL - 58 IS - 17 SP - 9705 EP - 9710 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-23173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Walther, Wolfgang A1 - Becker, Roland A1 - Nehls, Irene A1 - Lehmann, Andreas A1 - Redlich, Christel A1 - Flemig, Sabine A1 - Dorgerloh, Ute A1 - Win, Tin A1 - Buge, Hans-Gerhard T1 - Pentchlorophenol (PCP) in Soil - Certified Reference Materials for Environmental Analysis T2 - Analytica Conference 2002 CY - Munich, Germany DA - 2002-04-23 PY - 2002 SP - 1(?) AN - OPUS4-1389 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reck, Günter A1 - Becker, Roland T1 - Bis­[N-n-butyl-N-(3,5-di-tert-butyl-2-hydroxy­benzyl)­di­thio­carbamato-Kappa²S,S']zinc(II) N2 - Both zinc di­thio­carbamates and sterically hindered phenols are known to exhibit antioxidant activity. As part of an investigation on the effect of both moieties being combined in one mol­ecule, the title compound, [Zn(C17H26NOS2)2], has been prepared and its crystal structure determined. PY - 2003 DO - https://doi.org/10.1107/S1600536803007372 SN - 1600-5368 VL - 59 IS - 5 SP - m234 EP - m235 PB - Munksgaard CY - Copenhagen AN - OPUS4-2464 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Traub, Heike A1 - Win, Tin A1 - Lück, Detlef A1 - Koch, Matthias A1 - Becker, Roland T1 - Evaluation and Development of Methods for the Analysis of Soils according to § 8 of the German Federal Soil Protection Act T2 - 7th International FZK/TNO Conference on Contaminated Soil ; 7th ConSoil 2000 CY - Leipzig, Germany DA - 2000-09-18 KW - Soil KW - Heavy metals KW - Cyanide KW - Chromium KW - Organic contaminants KW - Analytical methods KW - Standardization KW - National law PY - 2000 SN - 0-7277-2954-3 VL - 2 SP - 904 EP - 905 PB - Telford CY - London AN - OPUS4-876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Scharf, Holger A1 - Becker, Roland ED - Gills, T. T1 - Soil samples prepared for a proficiency testing scheme operated by BAM T2 - 8th International Symposium on Biological and Environmental Reference Materials ; 8th BERM CY - Bethesda, MD, USA DA - 2000-09-17 PY - 2001 SN - 1618-2642 VL - 370 IS - 2-3 SP - 174 PB - Springer CY - Berlin AN - OPUS4-944 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schultze, Karin A1 - Becker, Roland A1 - Win, Tin A1 - Nehls, Irene T1 - Entwicklung, Herstellung und Zertifizierung eines Referenzmaterials zur Bestimmung von "Organochlorpestiziden in Boden" T2 - Tagung "Tag der Chemie" CY - Potsdam, Deutschland DA - 2000-11-08 PY - 2000 AN - OPUS4-1001 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene A1 - Wachholz, Sigrid A1 - Lehnik-Habrink, Petra A1 - Becker, Roland A1 - Win, Tin T1 - Neue Referenzmaterialien für die organische Analytik als Instrumente der Qualitätssicherung T2 - Tagung "Tag der Chemie" CY - Potsdam, Deutschland DA - 2000-11-08 PY - 2000 AN - OPUS4-1000 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Scharf, Holger A1 - Reich, Peter T1 - BAM-Ringversuche "Altlasten" - eine Bilanz PY - 2001 SN - 0942-3818 SN - 1864-8371 IS - 4 SP - 191 EP - 197 PB - Schmidt CY - Berlin AN - OPUS4-1143 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Nehls, Irene A1 - Buge, Hans-Gerhard T1 - Referenzmaterialien für Umweltanalysen PY - 2001 SN - 0016-3538 IS - 45 SP - 1089 EP - 1091 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-1186 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Becker, Roland A1 - Nehls, Irene T1 - The preparation and characterization of solid matrix reference materials for the trace analysis of organic environmental pollutants - relevant aspects of quality management N2 - Feste Referenzmaterialien für die Spurenanalytik umweltrelevanter organischer Schadstoffe erfordern aufgrund der geringen thermischen Belastbarkeit der Analyten besondere Aufarbeitungsstrategien für die Herstellung repräsentativer Teilproben. Das in der Fachgruppe I.2 seit 1994 für diesen Zweck systematisch aufgebaute technologische Instrumentarium wird vorgestellt, und das im Laufe der Jahre angesammelte Know How wird anhand von Beispielen vermittelt. Das im Laboratorium I.21 entwickelte Qualitätssystem für eine optimale Logistik der Arbeitsabläufe der Probenherstellung und -verwaltung sowie für eine bedarfsgerechte Charakterisierung der Materialien wird ausführlich erläutert. Bezüglich der Verwendung der Referenzmaterialien wird herausgestellt, daß es zwei gleichberechtigte Anwendungsrichtungen gibt: die interne Qualitätskontrolle mit zertifizierten Referenzmaterialien (ZRM, z.B. für die Methodenvalidierung) und die externe Qualitätskontrolle (Proficiency Testing = Kompetenzbewertung von Prüflaboratorien). Referenzmaterialien für das Proficiency Testing, die im Umweltbereich in viel größeren Stückzahlen umgesetzt werden können als ZRM, weisen bezüglich Homogenität und Charakterisierung die gleichen Qualitätskriterien wie ZRM auf. Diese Materialien haben - auch im internationalen Maßstab - stark an Bedeutung gewonnen. Ein englisches Abstract gibt es nicht, aber eine Grobgliederung zur Vortragsankündigung: This lecture includes: · the technological and logistical aspects of reference material preparation and sub-sampling and subsequent sample management, · appropriate measurement strategies for homogeneity and stability studies, · the use of relevant statistical tests to evaluate those measurement data, · the organisation of interlaboratory studies based on traceable measurements T2 - CENAM CY - Querétaro, Mexico DA - 2002-03-01 PY - 2002 AN - OPUS4-1612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Koch, Matthias A1 - Wachholz, Sigrid A1 - Win, Tin T1 - Quantification of total petrol hydrocarbons (TPH) in soil by IR-spectrometry and gas chromatography - conclusions from three proficiency testing rounds N2 - Due to the utilisation of 1,1,2-trichlorotrifluoroethane (CFE) as extraction solvent the IR-spectrometric determination of total petrol hydrocarbon (TPH) in soil according to ISO/TR 11046 has been replaced by gas chromatography/flame ionisation detection (GC/FID) after extraction with a halogen-free solvent according to ISO/DIS 16703:2001. The results obtained with both methods by field laboratories in three proficiency testing (PT) rounds are compared. The consensus means obtained with GC/FID are typically 10%-20% (ranging between 0% and 25%) higher than those found with IR-spectroscopy. On the contrary, coefficients of variation (CV) are roughly double in case of GC/FID and are briefly discussed against the background of the Horwitz equation. KW - Hydrocarbons KW - Soil KW - IR spectrometry KW - Gas chromatography KW - Interlaboratory comparison PY - 2002 DO - https://doi.org/10.1007/s00769-002-0476-9 SN - 0949-1775 SN - 1432-0517 VL - 7 IS - 7 SP - 286 EP - 289 PB - Springer CY - Berlin AN - OPUS4-1627 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -