TY - CONF A1 - Schultze, Karin A1 - Nehls, Irene A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Win, Tin T1 - Zertifiziertes Referenzmaterial "BAM-U007" - Organochlorpestizide in Boden T2 - ANAKON 2001 CY - Konstanz, Germany DA - 2001-04-04 PY - 2001 SP - 1(?) AN - OPUS4-1314 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Win, Tin T1 - Determination of pentachlorphenol (PCP) in waste wood - method comparison by a collaborative trial N2 - Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground “real life” starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.5–20 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of not, vert, similar19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation. KW - Extraction KW - Derivatisation KW - Sonication KW - Analysis KW - Gas chromatography KW - Regulation PY - 2002 DO - https://doi.org/10.1016/S0045-6535(02)00004-8 SN - 0045-6535 SN - 0366-7111 VL - 47 SP - 1001 EP - 1006 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-1628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Becker, Roland A1 - Nehls, Irene T1 - The preparation and characterization of solid matrix reference materials for the trace analysis of organic environmental pollutants - relevant aspects of quality management N2 - Feste Referenzmaterialien für die Spurenanalytik umweltrelevanter organischer Schadstoffe erfordern aufgrund der geringen thermischen Belastbarkeit der Analyten besondere Aufarbeitungsstrategien für die Herstellung repräsentativer Teilproben. Das in der Fachgruppe I.2 seit 1994 für diesen Zweck systematisch aufgebaute technologische Instrumentarium wird vorgestellt, und das im Laufe der Jahre angesammelte Know How wird anhand von Beispielen vermittelt. Das im Laboratorium I.21 entwickelte Qualitätssystem für eine optimale Logistik der Arbeitsabläufe der Probenherstellung und -verwaltung sowie für eine bedarfsgerechte Charakterisierung der Materialien wird ausführlich erläutert. Bezüglich der Verwendung der Referenzmaterialien wird herausgestellt, daß es zwei gleichberechtigte Anwendungsrichtungen gibt: die interne Qualitätskontrolle mit zertifizierten Referenzmaterialien (ZRM, z.B. für die Methodenvalidierung) und die externe Qualitätskontrolle (Proficiency Testing = Kompetenzbewertung von Prüflaboratorien). Referenzmaterialien für das Proficiency Testing, die im Umweltbereich in viel größeren Stückzahlen umgesetzt werden können als ZRM, weisen bezüglich Homogenität und Charakterisierung die gleichen Qualitätskriterien wie ZRM auf. Diese Materialien haben - auch im internationalen Maßstab - stark an Bedeutung gewonnen. Ein englisches Abstract gibt es nicht, aber eine Grobgliederung zur Vortragsankündigung: This lecture includes: · the technological and logistical aspects of reference material preparation and sub-sampling and subsequent sample management, · appropriate measurement strategies for homogeneity and stability studies, · the use of relevant statistical tests to evaluate those measurement data, · the organisation of interlaboratory studies based on traceable measurements T2 - CENAM CY - Querétaro, Mexico DA - 2002-03-01 PY - 2002 AN - OPUS4-1612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene A1 - Wachholz, Sigrid A1 - Lehnik-Habrink, Petra A1 - Becker, Roland A1 - Win, Tin T1 - Neue Referenzmaterialien für die organische Analytik als Instrumente der Qualitätssicherung T2 - Tagung "Tag der Chemie" CY - Potsdam, Deutschland DA - 2000-11-08 PY - 2000 AN - OPUS4-1000 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Scharf, Holger A1 - Becker, Roland ED - Gills, T. T1 - Soil samples prepared for a proficiency testing scheme operated by BAM T2 - 8th International Symposium on Biological and Environmental Reference Materials ; 8th BERM CY - Bethesda, MD, USA DA - 2000-09-17 PY - 2001 SN - 1618-2642 VL - 370 IS - 2-3 SP - 174 PB - Springer CY - Berlin AN - OPUS4-944 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Freeling, Finnian A1 - Scheurer, Marco A1 - Gökçe, Emine A1 - Strack, Katrin A1 - Sommerfeld, Thomas A1 - Sauer, Andreas A1 - Schneider, Jonas A1 - Härtel, Christoph A1 - Valkov, Vassil A1 - Moser, Lukas A1 - Geiß, Sabine A1 - Junginger, Sabine A1 - Schlittenbauer, Linda A1 - Suess, Elke A1 - Ruth, Katinka T1 - Standardising the quantification of trifluoroacetic acid in water: Interlaboratory validation trial using liquid chromatography-mass spectrometric detection (LC–MS/MS) N2 - The concentration of trifluoroacetic acid in surface and groundwaters and drinking water is subject of increasing concern. Since there is no standardised procedure available, German standardisation body DIN has initiated the first draft standard using liquid chromatography with tandem mass spectrometry (LC–MS/MS) after direct injection for the concentration range between ≥ 0.1 and 3 µg/L. Herein, the interlaboratory comparison as final validation step involving 12 expert laboratories from Germany and Switzerland is described. Two groundwaters, two surface waters, a drinking water, a rainwater, and two fortified groundwater samples displayed relative repeatability standard deviations between 3 and 7% and relative reproducibility standard deviation between 6 and 20% and were included in the draft standard DIN 38407-53. KW - TFA Trifluoroacetic acid KW - LC/MS-MS KW - Validation trial PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-632376 DO - https://doi.org/10.1007/s00769-025-01640-2 SN - 0949-1775 SP - 1 EP - 4 PB - Springer CY - Berlin AN - OPUS4-63237 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Kipphardt, Heinrich A1 - Lehnik-Habrink, Petra A1 - Panne, Ulrich A1 - Töpfer, Antje T1 - Stability testing in an integrated scheme N2 - ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment. KW - Certified reference materials KW - Stability KW - Shelf life KW - Arrhenius model KW - ERM PY - 2006 DO - https://doi.org/10.1007/s00769-006-0152-6 SN - 0949-1775 SN - 1432-0517 VL - 11 IS - 10 SP - 489 EP - 495 PB - Springer CY - Berlin AN - OPUS4-14063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Schwarzer, Martin A1 - Becker, Roland A1 - Kuhnhardt, Claus A1 - Nehls, Irene T1 - Methodenvergleich zur Bestimmung von extrahierbaren organischem Halogen (EOX) in Bodenproben N2 - Ziel der vorliegenden Untersuchungen, die im Rahmen einer Diplomarbeit der Fachhochschule Lausitz/Senftenberg an der BAM durchgeführt wurden, war ein Vergleich unterschiedlicher Extraktionsverfahren für die Bestimmung von extrahierbarem organischem Halogen (EOX) in Bodenproben. EOX ist ein für die rasche Bewertung der Organochlor- Belastung kontaminationsverdächtiger Flächen wertvoller Summenparameter, der sämtliche mit organischen Lösungsmittel extrahierbare Organohalogenverbindungen erfasst. Gegenwärtig existiert jedoch kein für die Bodenanalytik genormtes Verfahren für die Durchführung von EOX-Bestimmungen. Daher wird in der Praxis auf das für Schlämme und Sedimente entwickelte Verfahren nach DIN 38414 S17 (1990) zurückgegriffen, so auch in der Bundesbodenschutz- und Altlasten-Verordung (BBodSchV). Literaturangaben und Erfahrungen mit der Wiederfindungsrate polarer Extraktionsmittel und moderner Extraktionsverfahren bei Organochlorpestiziden, die eine bedeutende Quelle für EOX in Schlämmen und Böden darstellen, lassen vermuten, dass das genannte Normverfahren systematisch zu Unterbefunden neigen könnte. Für die Untersuchungen wurden an der BAM entwickelte Boden-Referenzmaterialien mit "natürlicher", über jahrzehntelangen Eintrag entstandener DDT- und Lindan-Belastung verwendet. Neben den klassischen Extraktionsverfahren nach Soxhlet kamen die ultraschallunterstützte Extraktion, die Mikrowellen- und die beschleunigte Lösungsmittelextraktion (ASE) jeweils mit Lösungsmitteln unterschiedlicher Polarität zum Einsatz. Extraktionsausbeuten und Wiederholpräzision der einzelnen Varianten wurden verglichen und vor dem Hintergrund der Ergebnisse unabhängiger Verfahren wie der gaschromatographischen Bestimmung der einzelnen Organochlorverbindungen bewertet. Die Polarität des Extraktionsmittels weist auch bei trockenen Böden den größten Einfluss auf die Extraktionsausbeuten der in den untersuchten Proben enthaltenen Organochlorverbindungen auf. Die Mischung Hexan/Aceton (1:1), die sich für die Extraktion verschiedener organischer Parameter bewährt hat, ist hinsichtlich der EOX-Analytik der existierenden Norm überlegen. T3 - BAM Forschungsberichtreihe - 263 PY - 2003 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1884 SN - 978-3-86509-083-4 SN - 0938-5533 VL - 263 SP - 1 EP - 64 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Win, Tin T1 - Ableitung validierter Probenahme und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von Leichtflüchtigen Chlorierten Kohlenwasserstoffen (LCKW) im Grundwasser im Rahmen von Altlastenuntersuchungen N2 - Im vorliegenden Forschungsbericht werden die Ergebnisse zum LFP Projekt „Ableitung validierter Probenahme- und Analysenmethoden für Zwischen- und Endprodukte der anaeroben Stoffverwertungsprozesse von LCKW im Grundwasser im Rahmen von Altlastenuntersuchungen“ (Länderfinanzierungsprogramm, Projekt B2/08, Laufzeit vom 01.09.2008 – 31.08.2009) zusammengefasst. Es werden verschiedene Verfahren der Probenahme und Analytik zur Bestimmung von Wasserstoff, Methan, Ethen und Vinylchlorid (VC) im Grundwasser untersucht und validiert. Für die Probenahme werden folgende Ansätze beschrieben und diskutiert: i. aktive Probenahme: Pumpprobe und Probenahme von in Grundwasser gelösten Gasen in Gasbeprobungsrohren (Gasmaus) ii. passive Probenahme: Diffusionsprobenahme in Polyethylenbeuteln (PDB) und Kunststoffspritzen als Diffusionssammler für gelöste Gase Der Einsatz aktiver (Pumpprobenahme, Schöpfprobenahme) und passiver (Diffusionsprobenahme) Probenahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probenahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probenahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Die chromatographischen Verfahren zur Bestimmung der Analyte werden umfänglich validiert und mit anderen geeigneten Analysenverfahren verglichen: I. Headspace-GC-FID zur Bestimmung von Methan, Ethen und VC aus der wässrigen Probenmatrix der Pumpprobe (i.) und des PDB (ii.) II. Direktinjektion-GC-PDD zur Bestimmung von Wasserstoff aus den gesammelten Gasproben der Gasmaus (i.) und der Kunststoffspritzen (ii.) Für die Bestimmung von Ethen und VC in Grundwasserproben (I.) werden Bestimmungsgrenzen von 0,1 μg/L erreicht. Methan kann aus wässrigen Proben nur ab 5 μg/L quantifiziert werden. Mit den Verfahren zur Bestimmung von Methan aus der Gasmaus (i.-II.) werden 0,1 μg/L im Grundwasser erreicht. Die Bestimmung von im Grundwasser gelösten Wasserstoff (II.) ist bis zu einer Konzentration von 1 nM möglich. Die Reproduzierbarkeit für die Bestimmung von Wasserstoff in Grundwasser liegt konzentrationsabhängig zwischen 10 bis 20% bei der aktiven Probenahme (i.-II.) und 10 bis 70% bei der passiven Probenahme (ii.-II.). Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probenahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring-Ergebnissen sollten von Ingenieurbüros und zuständige Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden. T3 - BAM Forschungsberichtreihe - 290 PY - 2010 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-1610 SN - 978-3-9813346-5-4 SN - 0938-5533 VL - 290 SP - 1 EP - 121 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-161 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Becker, Roland T1 - Querschnittsthema Referenzmaterialien: Planung Ringversuche N2 - Nach einer Erläuterung der international üblichen Definitionen von Referenzmaterialien und Matrix-Referenzmaterialien erfolgt eine Zusammenfassung der spezifischen Anforderungen bei Herstellung und Charakterisierung. Weiterhin werden die unterschiedlichen Anforderungen an die Durchführung von Ringversuchen im Sinne eines Methodenvergleiches, einer Eignungsprüfung von Laboratorien und der Zertifizierung von Matrix-Referenzmaterialien gegenübergestellt. Für den aktuell geplanten ersten Ringversuch zur Quantifizierung von Mikroplastik in Schwebstoffen mittels thermischer Verfahren werden die konkreten technischen Bedingungen zur Herstellung entsprechender Referenzmaterialien einschließlich der Homogenitätsprüfung ihrer Mikroplastikgehalte dargestellt. Die Besonderheiten des Ringversuches vor dem Hintergrund einer Normung der eingesetzten Verfahren werden diskutiert. T2 - Forschungsschwerpunkt „Plastik in der Umwelt – Quellen • Senken • Lösungsansätze“: 2. Workshop des Querschnittsthemas „Analytik und Referenzmaterialien“ CY - Augsburg, Germany DA - 4.7.2018 KW - Mikroplastik KW - Referenzmaterialien KW - Ringversuche KW - Thermische Verfahren KW - Schwebstoffe KW - Methodenvergleich PY - 2018 AN - OPUS4-45681 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -