TY - CONF A1 - Roesch, Philipp T1 - Investigation of PFAS Contaminated Solid Matrices by Combustion Ion Chromatography (CIC) - Development of EOF and AOF as Sum Parameters in Environmental Analysis N2 - Per- and polyfluoralkyl surfactants (PFAS) are industrially produced surface chemicals used in daily applications that have gained public and political attention due their unnaturally high appearance in drinking water, nourishments and soils.[1] Their chemical structures exhibit both lipophilic and hydrophilic properties, leading to a highly inert and persistent character.[2] Various PFAS have shown to be bioaccumulative in plants and animals, and some have been characterized as highly toxic when ingested.[3] When exposed to the environment, PFAS slowly get mobilized by natural water resources, leading to contamination of large areas of soil and natural water sources.[4] While PFAS contamination of drinking water has been investigated intensively, perfluoralkyl contamination of soils has been rarely examined as of yet. At the same time, an increasing amount of PFAS contamination sites are being discovered worldwide, calling for a sophisticated strategy towards analytical characterization.[5] Since the number of known PFAS already exceeds 4700, the established sum parameters like extractable organic fluorine (EOF) and adsorbable organic fluorine (AOF) are key elements to fully survey the impact of exposure.[6] Simultaneously, innovative soil remediation strategies are required to contain environmental destruction and to minimize further spreading of contaminants.[7] Addressing these challenges requires suitable analytical devices that are capable of mobilizing PFAS in the solid as well as in the liquid phase. The use of combustion ion chromatography (CIC) enables analysis of both immobile and volatile PFAS and allows the detection of both total fluorine (TF) and EOF or AOF of a given soil or aqueous sample. Based on preliminary results, the clean-up of a PFAS contaminated matrix is monitored via EOF detection over time. Additionally, we tested the effectiveness of urea (CH₄N₂O) as fluoride scavenger with the aim to improve the separation of inorganic and organic fluorine and therefore, to improve AOF accuracy. The presented findings can be contributive with regard to future AOF/EOF sum parameter development and application. T2 - Eurosoil 2021 CY - Online meeting DA - 23.08.2021 KW - PFAS KW - Sum parameter analyis KW - Combustion ion chromatography PY - 2021 AN - OPUS4-53195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp T1 - Current challenges on PFAS analytics N2 - Several thousand PFAS are in circulation and the current challenge lies in detection of these compounds. Wheter environmental contamination occurs via industrial emission or direct PFAS exposure, as through the use of AFFF fire fighting foams. Wheter PFAS need to be detected in consumer products or agricultral soil, or wheter human and wildlife exposure to PFSA needs to be evaluated, suitable analytical methods are required to identifiy the target class within a hugh variety of matrices. At the same time it is critical to detect trace amounts of compounds within various matrices, we want to make sure that we consider very volatile and mobile species, simultaneously want to assure that we do not overlook less and insoluble compounds. We require methods that allow both single and multi target analysis and want to have an ideal overview with the help of sum parameters. T2 - Workshop - Advancements of Analytical Techniques for Per- and Polyfluoroalkyl Substances (PFAS) CY - Online meeting DA - 01.09.2021 KW - PFAS KW - PFAS analytics KW - EOF/AOF PY - 2021 AN - OPUS4-53196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simon, Fabian A1 - Gehrenkemper, Lennart A1 - von der Au, Marcus A1 - Wittwer, Phillip A1 - Roesch, Philipp A1 - Pfeifer, Jens A1 - Cossmer, Antje A1 - Meermann, Björn T1 - A fast and simple PFAS extraction method utilizing HR–CS–GFMAS for soil samples N2 - Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution. KW - Per- and polyfluorinated alkly substances (PFASs) KW - High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) KW - Soils KW - Solid phase extraction (SPE) KW - Extractable organically bound fluorine (EOF) KW - Solid-liquid extraction PY - 2022 DO - https://doi.org/10.1016/j.chemosphere.2022.133922 VL - 295 SP - 1 EP - 9 PB - Elsevier Ltd. AN - OPUS4-54359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Roesch, Philipp T1 - Analysis of PFAS in Environmental Samples and Materials - Different Approaches via Fluorine K-Edge XANES Spectroscopy and Combustion Ion Chromatography N2 - Per- and polyfluoroalkyl substances (PFAS) have emerged over the course of the last twenty years as a global pollution issue. Altogether, there are currently more than 4700 known but only partly characterized fluorinated compounds identified by the Organization for Economic Cooperation and Development (OECD), as shown by a recently published classification proposal. The ongoing production of new, yet unrestricted PFAS alternatives has become a major challenge for environmental routine analytics, since the state-of-the-art method LC-MS/MS relies on structural information and availability of isotope standards of the targeted compound. First reported by Miyake et al., fluorine sum parameters like adsorbable organic fluorine (AOF), extractable organic fluorine (EOF) and total fluorine (TF) can be applied to survey and detect the presence of large amounts of unidentified organofluorine compounds in environmental matrices. Today fluorine sum parameters have been established as a useful supplement to classic target-analytical approaches of PFAS and were implemented for the first time as a sum value “PFAS-total” in the recently revised Drinking Water Directive (2020/2184) by the European Commission. In contrast, X-ray absorption near-edge structure (XANES) spectroscopy has been widely applied to identify low concentration of element-specific contamination without pre-treatment in environmental samples in the past. The XANES approach enables a penetration depth of approx. 1 µm (at fluorine K-edge energy; depending on the matrix) which is significantly deeper than for X-ray photoelectron spectroscopy (XPS; penetration depth approx. 10 nm). Furthermore, the method is fast, non-destructive and only simple preparation of the samples is required. In our work, we combined both F-XANES spectroscopy and combustion ion chromatography (CIC) in order to present a new analytical perspective on the investigation of PFAS in environmental media and material samples. T2 - SETAC Europe 2022 - 32nd Annual Meeting CY - Kopenhagen, Dänemark DA - 15.05.2022 KW - Sum parameter analysis KW - EOF KW - CIC KW - Fluor XANES KW - PFAS analysis PY - 2022 AN - OPUS4-54884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zweigle, J. A1 - Capitain, C. A1 - Simon, Fabian Michael A1 - Roesch, Philipp A1 - Bugsel, B. A1 - Zwiener, C. T1 - Non-extractable PFAS in functional textiles − Characterization by complementary methods: oxidation, hydrolysis, and fluorine sum parameters N2 - Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles like outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient in detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP assay, PhotoTOP), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, oxidation by dTOP and PhotoTOP and also hydrolysis by the THP are able to capture large fractions of the TF in form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) were much lower (e.g., factor ~25-50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from