TY - JOUR A1 - Rack, A. A1 - Rack, T. A1 - Stiller, M. A1 - Riesemeier, Heinrich A1 - Zabler, S. A1 - Nelson, K. T1 - In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants N2 - Micro-gap formation at the implant-abutment interface of two-piece dental implants was investigated in vitro using high-resolution radiography in combination with hard X-ray synchrotron radiation. Images were taken with the specimen under different mechanical loads of up to 100 N. The aim of this investigation was to prove the existence of micro-gaps for implants with conical connections as well as to study the mechanical behavior of the mating zone of conical implants during loading. Synchrotron-based radiography in comparison with classical laboratory radiography yields high spatial resolution in combination with high contrast even when exploiting micro-sized features in highly attenuating objects. The first illustration of a micro-gap which was previously indistinguishable by laboratory methods underlines that the complex micro-mechanical behavior of implants requires further in vitro investigations where synchrotron-based micro-imaging is one of the prerequisites. KW - X-ray imaging KW - Dental implants KW - Digital radiography KW - Implant-abutment interface PY - 2010 DO - https://doi.org/10.1107/S0909049510001834 SN - 0909-0495 SN - 1600-5775 VL - 17 IS - 2 SP - 289 EP - 294 PB - Blackwell Publishing CY - Oxford AN - OPUS4-22121 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mechler, S. A1 - Schumacher, G. A1 - Koteski, V. A1 - Riesemeier, Heinrich A1 - Schäfers, F. A1 - Mahnke, H.-E. T1 - Local structure and site substitution in amorphous and quasicrystalline Zr-Ti-Ni-(Cu) alloys N2 - Local structures of amorphous and quasicrystalline phases in Zr–Ti–Ni and Zr–Ti–Ni–Cu alloys have been studied by means of x-ray absorption spectroscopy. The amorphous phases show a high degree of icosahedral short-range order. In all investigated systems local order around Cu and Ni atoms was found to be nearly identical pointing to site substitution of Ni by Cu as the reason for an improved glass forming ability when Ni is partly substituted by Cu. The results strengthen an icosahedral cluster based approach for the structure of metallic glasses and indicate the importance of the medium-range order on glass formation. KW - Copper alloys KW - Frustration KW - Glass structure KW - Metallic glasses KW - X-ray absorption spectra PY - 2010 DO - https://doi.org/10.1063/1.3467265 SN - 0003-6951 SN - 1077-3118 VL - 97 IS - 4 SP - 041914-1 - 041914-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-22122 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zehbe, R. A1 - Haibel, A. A1 - Riesemeier, Heinrich A1 - Gross, U. A1 - Kirkpatrick, C.J. A1 - Schubert, H. A1 - Brochhausen, C. T1 - Going beyond histology. Synchrotron micro-computed tomography as a methodology for biological tissue characterization: from tissue morphology to individual cells N2 - Current light microscopic methods such as serial sectioning, confocal microscopy or multiphoton microscopy are severely limited in their ability to analyse rather opaque biological structures in three dimensions, while electron optical methods offer either a good three-dimensional topographic visualization (scanning electron microscopy) or high-resolution imaging of very thin samples (transmission electron microscopy). However, sample preparation commonly results in a significant alteration and the destruction of the three-dimensional integrity of the specimen. Depending on the selected photon energy, the interaction between X-rays and biological matter provides semi-transparency of the specimen, allowing penetration of even large specimens. Based on the projection-slice theorem, angular projections can be used for tomographic imaging. This method is well developed in medical and materials science for structure sizes down to several micrometres and is considered as being non-destructive. Achieving a spatial and structural resolution that is sufficient for the imaging of cells inside biological tissues is difficult due to several experimental conditions. A major problem that cannot be resolved with conventional X-ray sources are the low differences in density and absorption contrast of cells and the surrounding tissue. Therefore, X-ray monochromatization coupled with a sufficiently high photon flux and coherent beam properties are key requirements and currently only possible with synchrotron-produced X-rays. In this study, we report on the three-dimensional morphological characterization of articular cartilage using synchrotron-generated X-rays demonstrating the spatial distribution of single cells inside the tissue and their quantification, while comparing our findings to conventional histological techniques. KW - Cartilage KW - Chondrocyte KW - Synchrotron micro-computed tomography KW - Histology KW - Scanning electron microscopy KW - Three-dimensional imaging PY - 2010 DO - https://doi.org/10.1098/rsif.2008.0539 SN - 1742-5689 SN - 1742-5662 VL - 7 SP - 49 EP - 59 PB - The Royal Society CY - London AN - OPUS4-22123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich A1 - Wolk, Thomas T1 - Computed tomography experiments at BAMline PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=481 SN - 0179-4159 SP - 481 EP - 482 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Treimer, W. A1 - Feye–Treimer, U. A1 - Radke, C. A1 - Hilger, A. A1 - Neumann, O. A1 - Manke, I. A1 - Haibel, A. A1 - Rack, A. A1 - Riesemeier, Heinrich T1 - Investigations of mamma biopsies by means of µ-tomography PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=452 SN - 0179-4159 SP - 452 EP - 453 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Modregger, P. A1 - Schäfer, P. A1 - Lübbert, D. A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich A1 - Köhler, R. T1 - µ-CT with asymmetric Bragg reflection as magnifying optics PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=479 SN - 0179-4159 SP - 479 EP - 480 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7384 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Haibel, A. A1 - Rack, A. A1 - Weidemann, Gerd A1 - Riesemeier, Heinrich A1 - Goebbels, Jürgen A1 - Banhart, J. T1 - Investigation of pore formation in metallic foams by synchrotron computed tomography PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=324 SN - 0179-4159 SP - 324 EP - 325 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3510 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Haibel, A. A1 - Rack, A. A1 - Bütow, A. A1 - Kropf, H. A1 - Helwig, H.-M. A1 - Banhart, J. A1 - Weidemann, Gerd A1 - Riesemeier, Heinrich A1 - Goebbels, Jürgen T1 - Synchrotron-µ-tomography on complex materials PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=326 SN - 0179-4159 SP - 326 EP - 328 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3511 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Illerhaus, Bernhard A1 - Wolk, Thomas A1 - Riesemeier, Heinrich T1 - Computed tomography experiments at BAMline PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=403 SN - 0179-4159 SP - 403 EP - 404 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3512 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Wolk, Thomas A1 - Riesemeier, Heinrich T1 - Computed tomography experiments at BAMline PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=299 SN - 0179-4159 SP - 299 EP - 300 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2494 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Analytik Röntgenstrahlung in der BAMline T2 - Seminar der Abteilung I, BAM CY - Berlin, Germany DA - 2002-11-11 PY - 2002 AN - OPUS4-3002 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klobes, Peter A1 - Riesemeier, Heinrich A1 - Meyer, Klaus A1 - Goebbels, Jürgen A1 - Hellmuth, k.-H. T1 - Rock porosity determination by combination of X-ray computerized tomography with mercury porosimetry N2 - Abstract First results are described of coupling of mercury porosimetry with X-ray computerized tomography (CT) as a new combination technique for rock porosity studies. This technique is suitable for rock samples with a pronounced mercury intrusion-extrusion hysteresis and includes CT measurements before and after mercury intrusion. The entrapped portion of mercury, when the pressure after the intrusion into the rock sample is reduced to 0.1 MPa, serves as a contrast agent in the porous network to localize spatial distribution of rock porosity by CT. The results obtained show that the mercury intrusion and therefore the porosity were quite different for the separate mineral phases. Therefore the combination of mercury porosimetry and computer tomography can give 3-D data on mineral-specific porosity distributions with additional pore size information. In contrast to mercury porosimetry as a single method, results of the combination technique with CT represent a direct visualization of porosity variation and do not depend on any special pore network model. PY - 1997 SN - 0937-0633 VL - 357 IS - 5 SP - 543 EP - 547 PB - Springer CY - Berlin AN - OPUS4-11970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Klobes, Peter A1 - Riesemeier, Heinrich A1 - Meyer, Klaus A1 - Goebbels, Jürgen A1 - Siitari-Kauppi, M. A1 - Hellmuth, K.-H. ED - Gray, W. T1 - Investigation of rock samples using x-ray-microcomputer-tomography before and after mercury intrusion porosimetry N2 - A new method for the physical characterization of rock matrices for use in site investigations of nuclear waste repositories has been developed. The method can provide information needed in the assessment of the performance of the geosphere working as a natural barrier retarding the migration of radionuclides by diffusion into the rock matrix. Most conventional methods for the physical characterization of rocks give only bulk information. The combination of mercury porosimetry and computer tomography can give 3-D data on mineral-specific porosity distributions with additional pore size information. Additionally, limits for mineral-specific internal surface areas can be estimated, which is essential for the assessment of water-rock interaction and reactive interaction with radionuclides (sorption). Results of measurements on granitic rock (granodiorite) from the Baltic shield are discussed and integrated with results by complementary methods. T2 - 20th Materials Research Society Symposium on the Scientific Basis for Nuclear Waste Management CY - Boston, MA, USA DA - 1996-12-02 PY - 1997 SN - 1-558-99369-X SN - 0272-9172 N1 - Serientitel: Materials Research Society symposium proceedings – Series title: Materials Research Society symposium proceedings IS - 465 SP - 863 EP - 870 PB - Materials Research Society CY - Pittsburgh, Pa. AN - OPUS4-11971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zabler, S. A1 - Riesemeier, Heinrich A1 - Fratzl, P. A1 - Zaslansky, P. T1 - Fresnel-propagated imaging for the study of human tooth dentin by partially coherent x-ray tomography N2 - Recent methods of phase imaging in x-ray tomography allow the visualization of features that are not resolved in conventional absorption microtomography. Of these, the relatively simple setup needed to produce Fresnel-propagated tomograms appears to be well suited to probe tooth-dentin where composition as well as microstructure vary in a graded manner. By adapting analytical propagation approximations we provide predictions of the form of the interference patterns in the 3D images, which we compare to numerical simulations as well as data obtained from measurements of water immersed samples. Our observations reveal details of the tubular structure of dentin, and may be evaluated similarly to conventional absorption tomograms. We believe this exemplifies the power of Fresnel-propagated imaging as a form of 3D microscopy, well suited to quantify gradual microstructural-variations in teeth and similar tissues. KW - Fourier optics KW - Partial coherence in imaging KW - Tomography KW - X-ray imaging KW - Phase modulation KW - Dentistry KW - High resolution Sy-CT KW - Microstructure in human Teeth PY - 2006 DO - https://doi.org/10.1364/OE.14.008584 SN - 1094-4087 VL - 14 IS - 19 SP - 8584 EP - 8597 PB - Optical Society of America CY - Washington, DC AN - OPUS4-13869 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Maier, W. A1 - Arlt, Tobias A1 - Wannek, C. A1 - Manke, I. A1 - Riesemeier, Heinrich A1 - Krüger, P. A1 - Scholta, J. A1 - Lehnert, W. A1 - Banhart, J. A1 - Stolten, D. T1 - In-situ synchrotron X-ray radiography on high temperature polymer electrolyte fuel cells N2 - In contrast to classical low temperature polymer electrolyte fuel cells (LT-PEFCs), the membrane conductivity in high temperature polymer electrolyte fuel cells (HT-PEFCs) (operating temperature ~ 160 °C) is based on proton transport within phosphorus-oxygen acids at different levels of hydration, orthophosphoric acid (H3PO4) being the simplest example. We present for the first time in-situ synchrotron X-ray radiography measurements applied to a HT-PEFC to gain insight into the local composition of the membrane electrode assembly (MEA) under dynamic operating conditions. Transmission changes during the radiographic measurements exhibit a clear influence of the formation of product water on the membrane composition. KW - HT-PEFC KW - Synchrotron x-ray radiography KW - Membrane electrode assembly (MEA) KW - Phosphoric acid PY - 2010 DO - https://doi.org/10.1016/j.elecom.2010.08.002 SN - 1388-2481 VL - 12 IS - 10 SP - 1436 EP - 1438 PB - Elsevier CY - Amsterdam AN - OPUS4-23962 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Müller, K. A1 - Staude, Andreas A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich T1 - Synchrotron radiation and laboratory micro X-ray computed tomography - useful tools for the material identification of prehistoric objects made of ivory, bone or antler N2 - Archaeological bone, ivory and antler, as well as objects manufactured from them, are largely studied to extract as much information as possible from these materials. Among others, one key question in archaeology is the exact identification of the material. Even if the identification of different kinds of osseous material seems to be trivial in many cases, it can be a difficult issue when small, heavily carved and more or less altered ancient objects are concerned. This study was focused on the determination of parameters allowing the distinction of archaeological ivory, bone and antler in order to identify the raw material used for the manufacture of prehistoric objects. The high performance of synchrotron radiation (SR) and laboratory-based micro X-ray computed tomography (microCT), providing highly resolved three-dimensional information on the micromorphology, permitted the establishment of such distinctive features of modern references of ivory, antler, land mammal and whale bones: ivory shows characteristic tubular pores with a diameter of about 1 to 2 µm, bone and antler show typical osteon structures. In our measured references, antler shows on average larger and more elongated shaped pores of the osteons compared to terrestrial mammal bone. This feature however depends very much on the original localization of the studied sample within the antler. Whale bones can be distinguished from the other osseous materials by a cancellous, osteoporotic-like structure with irregularly distributed rounded porosities with diameters reaching up to 500 µm. These characteristics have also been tested on determined Palaeolithic fragments, as diagenetic changes during burial have to be considered and may lead to the modification of the parameters established on the basis of modern bone references. In general, the chemical composition of bone objects can change drastically over time while micromorphological features, as evidenced by microCT, seem to be less susceptible to such alterations. In addition, microCT enables the comparison of inner and possibly less altered parts of the objects, and can be considered as completely non-destructive for small mineralised prehistoric objects. In this study, specific morphological features allowing the distinction of ivory and of whale bone from other bone and antler material were determined, even for altered materials dating back to Palaeolithic periods. Thus, we provide, in addition to archaeozoological, chemical and isotopic markers, a new non-destructive tool to identify some raw materials used for the fabrication of osseous objects ranging from recent to prehistoric periods. PY - 2011 DO - https://doi.org/10.1039/c0ja00246a SN - 0267-9477 SN - 1364-5544 VL - 26 IS - 9 SP - 1802 EP - 1812 PB - Royal Society of Chemistry CY - London AN - OPUS4-24338 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rack, A. A1 - Weitkamp, T. A1 - Zanette, I. A1 - Morawe, C. A1 - Vivo Rommeveaux, A. A1 - Tafforeau, P. A1 - Cloetens, P. A1 - Ziegler, E. A1 - Rack, T. A1 - Cecilia, A. A1 - Vagovic, P. A1 - Harmann, E. A1 - Dietsch, R. A1 - Riesemeier, Heinrich T1 - Coherence preservation and beam flatness of a single-bounce multilayer monochromator (beamline ID19-ESRF) N2 - Larger spectral bandwidth and higher photon flux density are the major advantages of multilayer monochromators over crystal-based devices. Especially for synchrotron-based hard X-ray microimaging applications the increased photon flux density is important in order to achieve high contrast and resolution in space and/or time. However, the modifications on the beam profile induced by reflection on a multilayer are a drawback which can seriously harm the performance of such a monochromator. A recent study [A. Rack, T. Weitkamp, M. Riotte, D. Grigoriev, T. Rack, L. Helfen, T. Baumbach, R. Dietsch, T. Holz, M. Krämer, F. Siewert, M. Meduna, P. Cloetens, E. Ziegler, J. Synchrotron Radiat. 17 (2010) 496–510] has shown that the modifications in terms of beam flatness and coherence preservation can be influenced via the material composition of the multilayer coating. The present article extends this knowledge by studying further material compositions used on a daily basis for hard X-ray monochromatization at the beamline ID19 of the European Synchrotron Radiation Facility. KW - Multilayer mirrors KW - X-rays KW - X-ray optics KW - Coherence KW - X-ray monochromators KW - X-ray imaging KW - X-ray phase contrast KW - Synchrotron radiation PY - 2011 DO - https://doi.org/10.1016/j.nima.2010.11.069 SN - 0168-9002 SN - 0167-5087 VL - 649 IS - 1 SP - 123 EP - 127 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rack, T. A1 - Zabler, S. A1 - Rack, C. A1 - Stiller, M. A1 - Riesemeier, Heinrich A1 - Cecilia, A. A1 - Nelson, K. T1 - Coherent synchrotron-based micro-imaging employed for studies of micro-gap formation in dental implants N2 - Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium-based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro-bacterial leakage, especially when two-piece concepts are used. Synchrotron-based hard x-ray radiography, unlike conventional laboratory radiography, allows high spatial resolution in combination with high contrast even when micro-sized features in such highly attenuating objects are visualized. Therefore, micro-gap formation at interfaces in two-piece dental implants with the sample under different mechanical loads can be studied. We show the existence of micro-gaps in implants with conical connections and study the mechanical behavior of the mating zone of conical implants during loading. The micro-gap is a potential source of implant failure, i.e., bacterial leakage, which can be a stimulus for an inflammatory process. T2 - 10th International conference on X-ray microscopy CY - Chicago, Illinois, USA DA - 15.08.2010 KW - X-ray imaging KW - Dental implants KW - Digital radiography KW - Implant-abutment interface KW - Synchrotron radiation KW - X-ray phase contrast PY - 2011 SN - 978-0-7354-0925-5 DO - https://doi.org/10.1063/1.3625398 N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1365 SP - 445 EP - 448 AN - OPUS4-25347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tötzke, C. A1 - Manke, I. A1 - Hartnig, C. A1 - Kuhn, R. A1 - Riesemeier, Heinrich A1 - Banhart, J. T1 - Investigation of carbon fiber gas diffusion layers by means of synchrotron X-ray tomography N2 - The 3-dimensional spatial distribution of liquid water in different gas diffusion layer (GDL) materials was analyzed using synchrotron X-ray tomography. The capability of the method was demonstrated by virtually separating the GDL components in order to facilitate individual analysis of fiber material, liquid water and gas filled pore spaces. The influence of hydrophobic surface treatment on the water distribution in the GDL was illustrated by analyzing three GDL materials with different degrees of hydrophobicity. In the least hydrophobic sample, liquid water tends to form larger clusters which stretch out about several hundred µm inside the porous GDL. In contrast, only small water clusters were found in the strongly hydrophobic material with high Polytetrafluoroethylene (PTFE)-content as the liquid is partially pressed out of the GDL. Additionally, the influence of fiber orientation on the water distribution in the felt material was demonstrated. KW - Synchrotron X-ray tomography KW - Fuel cell KW - Gas diffusion layer (GDL) materials KW - Analysis of fiber material PY - 2011 DO - https://doi.org/10.1149/1.3635571 SN - 1938-6737 SN - 1938-5862 VL - 41 IS - 1 SP - 379 EP - 386 CY - Pennington, NJ, USA AN - OPUS4-25348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vercoutère, C. A1 - Müller, K. A1 - Chiotti, L. A1 - Nespoulet, R. A1 - Staude, Andreas A1 - Riesemeier, Heinrich A1 - Reiche, I. T1 - Rectangular beads from the final gravettian level of the Abri Pataud: raw material identification and its archaeological implications N2 - The Final Gravettian level (level 2) of the abri Pataud (Dordogne, France) yielded a large assemblage of body ornaments that consists essentially of 85 quite standardized rectangular beads. Some uncertainty remained about the raw material in which these small beads were made: mammoth ivory, reindeer antler or bone? Non-invasive methods were employed in order to determine the raw material. First chemical analyses using microbeam Proton Induced X-ray Emission analysis (microPIXE) did not enable us to conclude definitively. Therefore, synchrotron and laboratory X-ray microtomography (microCT) were applied on eight beads and allowed us to identify ivory for all of them except for one, which shows slightly different morphological features. KW - Abri Pataud KW - Gravettien final KW - Ivoire de mammouth KW - MicroPIXE KW - MicroCT KW - Perles rectangulaires KW - Final Gravettian KW - Mammoth ivory KW - Rectangular beads PY - 2011 SN - 1960-1360 VL - 35 SP - 259 EP - 271 PB - Presses Univ. de Rennes CY - Rennes AN - OPUS4-26250 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arlt, Tobias A1 - Manke, I. A1 - Wippermann, K. A1 - Riesemeier, Heinrich A1 - Mergel, J. A1 - Banhart, J. T1 - Investigation of the local catalyst distribution in an aged direct methanol fuel cell MEA by means of differential synchrotron X-ray absorption edge imaging with high energy resolution N2 - Synchrotron X-ray absorption edge imaging with high energy resolution was applied to study aging of fuel cell catalyst materials. The combination of an imaging and a high X-ray energy resolution set-up allows acquiring spatially resolved XAS (XANES and EXAFS) spectra. We analyzed the two-dimensional distribution of Pt and Ru in fresh and aged fuel cell catalysts. Spatially resolved XAS images were taken at the RuK edge and at the PtL3 edge. Taking radiographs above and below the absorption edges provides quantitative information about the thickness of the catalytic materials and additional chemical information. A strong influence of the flow field channels and the structure of the gas diffusion layers on the thicknesses of the catalytic elements were found: a thinner catalyst layer was found below the ribs of the flow field geometries as well as under crossing points of fiber bundles of the woven gas diffusion layers. KW - XAS KW - X-ray energy edge KW - Membrane electrode assembly KW - Direct methanol fuel cell KW - Aging mechanism KW - X-ray synchrotron radiography PY - 2013 DO - https://doi.org/10.1016/j.jpowsour.2012.08.038 SN - 0378-7753 VL - 221 SP - 210 EP - 216 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-27372 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, G. A1 - Nellesen, J. A1 - Anar, N. B. A1 - Ehrig, Karsten A1 - Riesemeier, Heinrich A1 - Tillmann, W. T1 - 3D analysis of micro-deformation in VHCF-loaded nodular cast iron by µCT N2 - The impact of very high cycle fatigue (VHCF) load conditions on the microstructure of specimens consisting of nodular cast iron is analyzed by means of micro-computed tomography (µCT) utilizing both monochromatic synchrotron radiation and polychromatic X-ray tube radiation. Using 3D µCT, the microstructure in the region of the smallest cross-sections of shouldered round specimens is imaged in different stages of the VHCF loading. By digital image correlation (DIC) of these tomograms strain fields are analyzed three-dimensionally. Strain levels in the range of a few percent were detected. It is proven that a localization of strain allows to predict the site of the crack which precedes and induces the macroscopic failure of the specimens. KW - VHCF (very high cycle fatigue) KW - µCT KW - Micro-computed tomography KW - Strain analysis KW - Nodular cast iron PY - 2013 DO - https://doi.org/10.1016/j.msea.2013.04.057 SN - 0921-5093 SN - 1873-4936 VL - 577 SP - 202 EP - 209 PB - Elsevier CY - Amsterdam AN - OPUS4-28533 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Drastic evolutionary changes in a cave insect's head morphology - First insights from high-resolution synchroton uCT T2 - EUROMAT 2013 CY - Seville, Spain DA - 2013-09-09 PY - 2013 AN - OPUS4-29258 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Coherent synchroton-based micro-imaging employed for quantitative studies of micro-gap formation in dental implants T2 - EUROMAT 2013 CY - Seville, Spain DA - 2013-09-09 PY - 2013 AN - OPUS4-29259 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Wolk, Thomas A1 - Riesemeier, Heinrich T1 - First computed tomography experiments at BAMline PY - 2002 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2001.pdf#page=249 SN - 0179-4159 SP - 249 EP - 250 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1325 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rabe, Torsten A1 - Goebbels, Jürgen A1 - Weidemann, Gerd A1 - Riesemeier, Heinrich A1 - Rudert, Rainer T1 - Green Body Characterization by Computed Tomography with Synchrotron Radiation T2 - Symposium Grünkörpercharakterisierung ; 8. Keramik-Tag der BAM CY - Berlin, Germany DA - 2001-05-28 PY - 2001 SN - 0177-6983 VL - 16 IS - 2 SP - 204 EP - 210 PB - Bauverlag CY - Bad Honnef AN - OPUS4-1835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Rack, A. A1 - Zabler, S. A1 - Riesemeier, Heinrich A1 - Weidemann, Gerd A1 - Müller, Bernd R. A1 - Helfen, L. A1 - Stiller, M. A1 - Knabe, C. A1 - Goebbels, Jürgen A1 - Banhart, J. T1 - Nondestructive 3D insights into foamy metals and bioregenerative ceramics KW - X-ray Computed Tomography KW - Metal foams KW - Bioregenerative ceramics PY - 2008 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/infos/bessy/highlights2007.pdf#page=34 SN - 1611-6127 SP - 34 EP - 35 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-17538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rack, A. A1 - Riesemeier, Heinrich A1 - Zabler, S. A1 - Weitkamp, T. A1 - Müller, Bernd R. A1 - Weidemann, Gerd A1 - Modregger, P. A1 - Banhart, J. A1 - Helfen, L. A1 - Danilewsky, A.N. A1 - Gräber, H.G. A1 - Heldele, R. A1 - Mayzel, B. A1 - Goebbels, Jürgen A1 - Baumbach, T. ED - Stuart R. Stock, T1 - The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA) N2 - The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed. KW - Microtomography KW - Non-destructive evaluation KW - Coherent imaging KW - X-ray refraction KW - X-ray phase contrast KW - Synchrotron-CT KW - Synchrotron instrumentation KW - Scintillator KW - Bragg magnification KW - Holotomography KW - X-ray topography PY - 2008 DO - https://doi.org/10.1117/12.793721 SN - 0277-786X VL - 7078 SP - 70780X-1 - 70780X-9 AN - OPUS4-18296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Goebbels, Jürgen A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Weidemann, Gerd ED - Mazal, P. T1 - Special Solutions for CT-Investigations with Synchrotron Radiation T2 - 2nd International Workshop of NDT Experts CY - Prague, Czech Republic DA - 2003-10-06 KW - Computed Tomography KW - Synchrotron radiation KW - X-ray refraction KW - Metal matrix composites KW - Porosity PY - 2003 SN - 80-2142475-3 SP - 91 EP - 97 PB - Univ. of Technology CY - Brno AN - OPUS4-2876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zehbe, R. A1 - Riesemeier, Heinrich A1 - Kirkpatrick, C.J. A1 - Brochhausen, C. T1 - Imaging of articular cartilage - data matching using X-ray tomography, SEM, FIB slicing and conventional histology N2 - The study was aimed at demonstrating a true cellular resolution for articular cartilage using synchrotron radiation-based X-ray microcomputed tomography (SR-µCT) with a sample-specific optimization of the phase contrast. The generated tomographic data were later used to prepare a matching histological sample from the full volume specimen. We used highly coherent and monochromatic X-rays from a synchrotron source to image a tissue sample of bovine articular cartilage after deparaffinization. Phase contrast enhancement was achieved by using five different sample to detector distances for the same X-ray energy. After tomography, the sample was re-embedded into resin while retaining a dedicated sample orientation for subsequent sectioning and polishing, which was conducted until a previously defined spatial position was achieved. The protocol for resin embedding was developed to inhibit morphological changes during embedding. Giemsa staining was applied for better structural and morphological discrimination. Data from tomography and lightmicroscopy were exactly matched and finally compared to results from FIB/SEM imaging. Image detail was achieved at a single cell resolution. Image detail was achieved at a single cell resolution, which has been estimated to be 0.833 µm/voxel in the tomographic data. SR-µCT with optimized phase contrast properties represents a method to investigate biological tissues in certain areas of interest, where true cellular resolution or enhanced volumetric imaging is needed. In this study, we demonstrate that this method can compete with conventional histology using light microscopy but even surpasses it due to the possibility of retrieving volumetric data. KW - Synchrotron radiation-based µCT KW - Phase contrast KW - FIB/SEM imaging KW - Histology KW - Articular cartilage KW - Data matching PY - 2012 DO - https://doi.org/10.1016/j.micron.2012.05.001 SN - 0047-7206 SN - 0968-4328 VL - 43 IS - 10 SP - 1060 EP - 1067 PB - Pergamon Press CY - Oxford AN - OPUS4-26435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hartnig, C. A1 - Kuhn, R. A1 - Krüger, P. A1 - Manke, I. A1 - Kardjilov, N. A1 - Goebbels, Jürgen A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich T1 - Wassermanagement in Brennstoffzellen - die Bedeutung von hochauflösenden zerstörungsfreien Untersuchungsmethoden N2 - Ein effektives Wassermanagement ist ein wichtiger Aspekt in der Entwicklung von Brennstoffzellen hinsichtlich Langzeitstabilität und Optimierung der Leistungsfähigkeit. Eine zentrale Rolle spielt dabei die Gasdiffusionslage, die für die gleichmäßige Verteilung der Reaktionsgase auf die elektrochemisch aktive Schicht (Katalysator) sorgen soll. In diesem Beitrag werden gemeinsame Forschungsaktivitäten des Helmholtz-Zentrums Berlin für Materialien und Energie (Entwicklung bildgebender Verfahren) sowie des Zentrums für Sonnenenergie- und Wasserstoff-Forschung (ZSW, Entwicklung von Brennstoffzellen) vorgestellt. Im Rahmen dieser Kooperation werden die Entstehung, die Verteilung und der Transport von flüssigem Wasser, kurz das Wassermanagement, unter Betriebsbedingungen untersucht. Mittels Synchrotronradiografie und -tomografie werden kleinste Wassercluster in der Gasdiffusionslage detektiert. Die gewonnenen Erkenntnisse dienen der Modifikation und einer gezielten Auswahl der eingesetzten Materialien. KW - Synchrotronstrahlung KW - Brennstoffzellen KW - Materialcharakterisierung KW - Zerstörungsfrei PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 609 EP - 614 PB - Hanser CY - München AN - OPUS4-18656 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. A1 - Diete, W. A1 - Klein, U. A1 - Frahm, R. T1 - BAMlin - the first hard X-ray beamline at BESSY II N2 - The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications. KW - Double-Multilayer-Monochromator with meridional bender KW - Double-Crystal-Monochromator with sagittal bender KW - X-ray fluorescence analysis KW - Micro-computed tomography KW - X-ray topography KW - Detector calibration KW - Reflectometry PY - 2001 DO - https://doi.org/10.1016/S0168-9002(01)00466-1 SN - 0168-9002 SN - 0167-5087 VL - 467-468 IS - 1 SP - 703 EP - 706 PB - North-Holland CY - Amsterdam AN - OPUS4-1171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - High resolution synchrotron-based radiography and tomography at the Bamline (BESSY) T2 - 9th International Conference on X-Ray Microscopy, XRM2008 CY - Zurich, Switzerland DA - 2008-07-21 PY - 2008 AN - OPUS4-17853 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Perfomance of the BAMline at a BESSY II wavelength shifter T2 - 8th International Conference on Synchrotron Radiation Instrumentation (SRI 2003) CY - San Francisco, CA, USA DA - 2003-08-25 PY - 2003 AN - OPUS4-5051 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Three dimensional analysis, modeling and simulation of microstructures and transport processes in carbon fiber based porous materials T2 - Third Joint BER II and BESSY II Users´ Meeting CY - Berlin, Germany DA - 2011-11-30 PY - 2011 AN - OPUS4-25126 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rack, A. A1 - Zabler, S. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Weidemann, Gerd A1 - Lange, Axel A1 - Goebbels, Jürgen A1 - Hentschel, Manfred P. A1 - Görner, Wolf T1 - High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II) N2 - The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast — dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope — up to 14 mm x 14 mm field of view) to high resolution (microscope — down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science. KW - Microtomography KW - Non-destructive evaluation KW - Synchrotron instrumentation KW - Coherent imaging KW - X-ray refraction KW - Phase contrast KW - Holotomography KW - Synchrotron-CT KW - Scintillator KW - Bragg magnification PY - 2008 DO - https://doi.org/10.1016/j.nima.2007.11.020 SN - 0168-9002 SN - 0167-5087 VL - 586 IS - 2 SP - 327 EP - 344 PB - North-Holland CY - Amsterdam AN - OPUS4-17738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. T1 - The first hard X-rays at the BAMline PY - 2001 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2000.pdf#page=329 SN - 0179-4159 SP - 329 EP - 331 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krüger, P. A1 - Markötter, Henning A1 - Klages, M. A1 - Haußmann, J. A1 - Arlt, Tobias A1 - Riesemeier, Heinrich A1 - Hartnig, C. A1 - Banhart, J. A1 - Manke, I. A1 - Scholta, J. T1 - Dreidimensionale Untersuchung der Wasserverteilung in einer Miniatur-PEM-Brennstoffzelle KW - Resolution neutron-radiography KW - Local current distribution KW - Cells KW - Quantification PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 712 EP - 717 PB - Hanser CY - München AN - OPUS4-23044 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Alink, R. A1 - Haußmann, J. A1 - Dittmann, K. A1 - Arlt, Tobias A1 - Wieder, F. A1 - Tötzke, C. A1 - Klages, M. A1 - Reiter, C. A1 - Riesemeier, Heinrich A1 - Scholta, J. A1 - Gerteisen, D. A1 - Banhart, J. A1 - Manke, I. T1 - Visualization of the water distribution in perforated gas diffusion layers by means of synchrotron X-ray radiography N2 - Perforated gas diffusion layers (GDLs) of polymer electrolyte membrane fuel cells (PEMFCs) were investigated by means of in-situ synchrotron X-ray radiography during operation. We found a strong influence of perforations on the water distribution and transport in the investigated Toray TGP-H-090 GDL. The water occurs mainly around the perforations, while the holes themselves show varying water distributions. Some remain dry, while most of them fill up with liquid water after a certain period or might serve as drainage volume for effective water transport. KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Radiography KW - Synchrotron KW - X-ray imaging KW - Perforated gas diffusion layer (GDL) KW - Water transport PY - 2012 DO - https://doi.org/10.1016/j.ijhydene.2012.01.141 SN - 0360-3199 VL - 37 IS - 9 SP - 7757 EP - 7761 PB - Elsevier CY - Oxford AN - OPUS4-26434 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Williams, S. H. A1 - Hilger, A. A1 - Kardjilov, N. A1 - Manke, I. A1 - Strobl, M. A1 - Douissard, P.A. A1 - Martin, T. A1 - Riesemeier, Heinrich A1 - Banhart, J. T1 - Detection system for microimaging with neutrons N2 - A new high-resolution detector setup for neutron imaging has been developed based on infinity-corrected optics with high light collection, combined with customized mounting hardware. The system can easily be installed, handled and fitted to any existing facility, avoiding the necessity of complex optical systems or further improved electronics (CCD). This is the first time optical magnification higher than 1:1 has been used with scintillator-based neutron detectors, as well as the first implementation of infinity corrected optics for neutron imaging, achieving the smallest yet reported effective pixel size of 3.375 µm. A novel transparent crystal scintillator (GGG crystal) has been implemented with neutrons for the first time to overcome limitations of traditional powder scintillators (Li6/ZnS, Gadox). The standardized procedure for resolution measurements with the Modulation Transfer Function (MTF) is summarized to facilitate comparison between instruments and facilities. Using this new detector setup, a resolution of 14.8 µm with a field of view of 6 mm × 6 mm has been achieved while maintaining reasonable count times. These advances open a wide range of new possible research applications and allow the potential for additional future developments. KW - Instrumentation for neutron sources KW - Neutron radiography KW - Neutron detectors (cold, thermal, fast neutrons) PY - 2012 DO - https://doi.org/10.1088/1748-0221/7/02/P02014 SN - 1748-0221 VL - 7 IS - P02014 SP - 1 EP - 26 PB - Inst. of Physics Publ. CY - London AN - OPUS4-26433 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schott, M. A1 - Szczerba, Wojciech A1 - Posset, U. A1 - Vuk, A.S. A1 - Beck, M. A1 - Riesemeier, Heinrich A1 - Thünemann, Andreas A1 - Kurth, D. G. T1 - In operando XAFS experiments on flexible electrochromic devices based on Fe(II)-metallo-supramolecular polyelectrolytes and vanadium oxides N2 - Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved. KW - Metallo-supramolecular polyelectrolytes KW - Vanadium oxide KW - Electrochromism KW - Electrochromic device KW - Cyclic voltammetry KW - XAFS PY - 2016 DO - https://doi.org/10.1016/j.solmat.2015.10.015 SN - 0927-0248 VL - 147 SP - 61 EP - 67 PB - Elsevier B.V. CY - Amsterdam [u.a.] AN - OPUS4-35251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Manke, I. A1 - Haußmann, J. A1 - Arlt, Tobias A1 - Klages, M. A1 - Krüger, P. A1 - Hartnig, C. A1 - Scholta, J. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Banhart, J. T1 - Combined synchrotron X-ray radiography and tomography study of water transport in gas diffusion layers N2 - Synchrotron X-ray radiography and tomography investigations of a custom-made polymer electrolyte membrane fuel cell optimised for visualisation purposes are presented. The 3D water distribution and transport pathways in the porous carbon fibre gas diffusion layers (GDLs) were investigated. The authors found that water is not only moving from the GDL into the channel, but can also take the opposite way, that is, from the channel into free pore space of the GDL. Such movement of water into the opposite direction has been subject of speculations but has so far not yet been reported and might bring new insights into the general water transport behaviour, which might give new aspects to the general description of water transport processes and influence modelling assumptions to describe the process taking place in the GDL. KW - Synchrotron radiography KW - Synchrotron tomography KW - Gas diffusion layers KW - Water transport PY - 2012 DO - https://doi.org/10.1049/mnl.2012.0410 SN - 1750-0443 VL - 7 IS - 7 SP - 689 EP - 692 PB - IET CY - London AN - OPUS4-26282 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vincze, L. A1 - Reuter, Dirk T1 - X-ray scattering in X-ray fluorescence spectra with X-ray monochromatic, polarised excitation - modelling, experiment, and Monte-Carlo simulation N2 - A systematic series of measurements has been carried out with monochromatic X-ray excitation with synchrotron radiation in order to check a physical model on X-ray scattering. The model has recently been successfully tested for the case of polychromatic, unpolarised excitation emitted by an X-ray tube. Our main purpose is the modelling of a physical background in X-ray fluorescence spectra, so that improved quantitative results can be achieved especially for strongly scattering specimens. The model includes single Rayleigh and Compton scattering in the specimen, the effect of bound electrons, the challenging Compton broadening and the polarisation degree. Representative specimens, measurement geometries and excitation energies have been selected with synchrotron monochromatic light at BAMline/BESSY II. Monte-Carlo simulations have been also carried out in order to evaluate the quality of the results achieved with the model. KW - X-ray scattering KW - Monochromatic excitation KW - Polarisation KW - Modelling KW - Monte-Carlo simulation PY - 2011 DO - https://doi.org/10.1016/j.nimb.2011.04.009 SN - 0168-583X SN - 1872-9584 VL - 269 IS - 13 SP - 1493 EP - 1498 PB - Elsevier CY - Amsterdam AN - OPUS4-23765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Alrwashdeh, S. S. A1 - Markötter, Henning A1 - Haußmann, J. A1 - Hilger, A. A1 - Klages, M. A1 - Müller, Bernd R. A1 - Kupsch, Andreas A1 - Riesemeier, Heinrich A1 - Scholta, J. A1 - Manke, I. T1 - Investigation of water transport in newly developed micro porous layers for polymer electrolyte membrane fuel cells N2 - In this investigation, synchrotron X-ray imaging was used to investigate the water distribution inside newly developed gas diffusion media in polymer electrolyte membrane fuel cells. In-situ radiography was used to reveal the relationship between the structure of the microporous layer (MPL) and the water flow in a newly developed MPL equipped with randomly arranged holes. A strong influence of these holes on the overall water transport was found. This contribution provides a brief overview to some of our recent activities on this research field. KW - Polymer electrolyte membrane fuel cell KW - Microporous layer KW - Water distribution KW - Radiography KW - Synchrotron X-ray imaging PY - 2017 DO - https://doi.org/10.9729/AM.2017.47.3.101 SN - 2287-4445 SN - 2287-5123 VL - 47 IS - 3 SP - 101 EP - 104 AN - OPUS4-43356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - De Samber, B. A1 - Scharf, Oliver A1 - Buzanich, Günter A1 - Garrevoet, J. A1 - Tack, P. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Evens, R. A1 - De Schamphelaere, K. A1 - Falkenberg, G. A1 - Janssen, C. A1 - Vincze, L. T1 - Three-dimensional X-ray fluorescence imaging modes for biological specimens using a full-field energy dispersive CCD camera N2 - Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany). KW - CXC KW - BAMline KW - Maia detector KW - Synchrotron PY - 2019 DO - https://doi.org/10.1039/c9ja00198k VL - 34 IS - 10 SP - 2083 EP - 2093 PB - Royal Society of Chemistry CY - Cambridge, United Kingdom AN - OPUS4-49359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Haußmann, J. A1 - Alink, R. A1 - Dittmann, K. A1 - Tötzke, C. A1 - Krüger, P. A1 - Klages, M. A1 - Arlt, Tobias A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Scholta, J. A1 - Gerteisen, D. A1 - Manke, I. A1 - Banhart, J. T1 - Investigation of fuel cell materials and liquid water transport by means of synchrotron imaging N2 - Synchrotron imaging allows addressing various important issues in fuel cell research, for example water distribution and transport. The water distribution in polymer electrolyte membrane fuel cells (PEMFCs) was observed quasi in-situ directly after operation by means of synchrotron tomography. The 3D data set was compared with the tomogram of a dry cell in order to separate the water distribution from cell materials. Engineered transport pathways realized by perforating holes through the gas diffusion layer (GDL) are a recent approach to optimize water transport and cell performance. For some parameter sets a cell performance increase and an improvement of stabilization have already been proven. We present high resolution investigations of the water distribution in perforated GDLs of operating PEMFCs by means of in-situ synchrotron radiography. The surrounding areas of the holes exhibited a distinct hydrophilic character. KW - Gas-diffusion layers KW - Resolution neutron-radiography KW - X-ray radiography KW - Visualization KW - PEMFC PY - 2013 DO - https://doi.org/10.1149/04529.0195ecst SN - 1938-6737 SN - 1938-5862 VL - 45 IS - 29 SP - 195 EP - 202 CY - Pennington, NJ, USA AN - OPUS4-30545 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Manke, I. A1 - Krüger, P. A1 - Arlt, Tobias A1 - Huassmann, J. A1 - Klages, M. A1 - Riesemeier, Heinrich A1 - Hartnig, C. A1 - Scholta, J. A1 - Banhart, J. T1 - Investigation of 3D water transport paths in gas diffusion layers by combined in-situ synchrotron X-ray radiography and tomography N2 - The three-dimensional water distribution and water transport paths in the gas diffusion layer (GDL) and the adjacent micro-porous layer (MPL) of a polymer electrolyte membrane fuel cell (PEMFC) were analyzed during cell operation. The technique of quasi in-situ X-ray tomography was used for a 3D visualization of the water distribution and the structure of the GDL at different operating conditions. Based on findings from in-situ radiographic measurements water transport paths were detected and subsequently examined by tomography. The combination of these 2D and 3D techniques allows for a fully three-dimensionally resolved visualization of transport paths through the GDL. KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Radiography KW - Tomography KW - Synchrotron X-ray imaging KW - Gas diffusion layer (GDL) KW - Water transport paths PY - 2011 DO - https://doi.org/10.1016/j.elecom.2011.06.023 SN - 1388-2481 VL - 13 IS - 9 SP - 1001 EP - 1004 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Arlt, Tobias A1 - Manke, I. A1 - Wippermann, K. A1 - Tötzke, C. A1 - Markötter, Henning A1 - Riesemeier, Heinrich A1 - Mergel, J. A1 - Banhart, J. T1 - Investigation of the three-dimensional ruthenium distribution in fresh and aged membrane electrode assemblies with synchrotron X-ray absorption edge tomography N2 - Synchrotron X-ray absorption edge imaging was used to investigate the ruthenium distribution in both fresh and aged Pt/Ru-based membrane electrode assemblies (MEA) of direct methanol fuel cells. MEAs aged in different ways were analyzed: artificially aged by MeOH depletion and aged for 1700 h in an operating fuel cell stack. An element sensitive tomographic technique – differential X-ray absorption edge tomography – was applied allowing for a 3D-visualization of the ruthenium distribution within the MEA. We found a markedly changed Ru distribution after aging which is correlated to the GDL structure, the flow field geometry, and CO2 transport in the methanol solution. KW - Edge tomography KW - Ruthenium distribution KW - Direct methanol fuel cells KW - Synchrotron X-ray KW - PtRu corrosion PY - 2011 DO - https://doi.org/10.1016/j.elecom.2011.05.013 SN - 1388-2481 VL - 13 IS - 8 SP - 826 EP - 829 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25243 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Manke, I. A1 - Hartnig, C. A1 - Krüger, P. A1 - Wippermann, K. A1 - Arlt, Tobias A1 - Choinka, G. A1 - Riesemeier, Heinrich A1 - Banhart, J. T1 - Hochauflösende Synchrotron-Radiografie KW - PEM Fuel-cells KW - Local current distribution KW - Neutron imaging technique KW - Water transport PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 698 EP - 704 PB - Hanser CY - München AN - OPUS4-23046 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, Henning A1 - Haußmann, J. A1 - Alink, R. A1 - Tötzke, C. A1 - Arlt, Tobias A1 - Klages, M. A1 - Riesemeier, Heinrich A1 - Scholta, J. A1 - Gerteisen, D. A1 - Banhart, J. A1 - Manke, I. T1 - Influence of cracks in the microporous layer on the water distribution in a PEM fuel cell investigated by synchrotron radiography N2 - Water evolution in the gas diffusion layer of a polymer electrolyte membrane fuel cell was visualized in situ by means of synchrotron X-ray radiography. Cracks in the microporous layer were identified as start points of efficient liquid water transfer paths through the gas diffusion layer. Quantitative analysis of the water flow rate through those arbitrarily distributed cracks into the gas channel revealed that they have a strong influence on the overall liquid water transport. This could find entry into future material design and simulation. KW - Polymer electrolyte membrane fuel cell (PEMFC) KW - Radiography KW - Synchrotron X-ray imaging KW - Microporous layer (MPL) KW - Water transport KW - Liquid water flow rate PY - 2013 DO - https://doi.org/10.1016/j.elecom.2013.04.006 SN - 1388-2481 VL - 34 SP - 22 EP - 24 PB - Elsevier CY - Amsterdam AN - OPUS4-30548 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riesemeier, Heinrich T1 - Combined synchrotron X-ray and neutron imaging for the characterization of fuel cells T2 - Third Joint BER II and BESSY II Users´ Meeting CY - Berlin, Germany DA - 2011-11-30 PY - 2011 AN - OPUS4-25125 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -