TY - JOUR A1 - Riedel, Jens A1 - Hufgard, Josefin A1 - You, Yi T1 - LIBS at high duty-cycles: effect of repetition rate and temporal width on the excitation laser pulses N2 - Laser-induced breakdown spectroscopy (LIBS) is becoming a more mature technology every year with new variants such as laser ablation molecular isotopic spectrometry, reheating by various discharge techniques, and multiple pulse excitation schemes, in which sometimes lasers of different pulse lengths are used. However, lasers with inherent parameters like pulse length and repetition rate are still almost exclusively employed. Recent years have witnessed the advent of novel high-repetition-rate laser concepts for machining processes, like welding, milling, and engraving. Here, a comprehensive study of single-pulse LIBS spectra of a single aluminum target is presented to showcase the applicability of flexible high duty-cycle master oscillator power amplifier (MOPA) lasers. Although traditional flashlamp-pumped Fabry–Pérot lasers only permit a variation in the pulse energy and are operated at very low duty-cycles, MOPA lasers add repetition rate and pulse length as variable parameters. A thorough analysis of the temporal plasma behavior revealed the emission dynamic to closely match the excitation laser pulse pattern. An aluminum sample’s spectral response was shown to be significantly impacted by variations in both rate and length. Although the spectral emission strength of the elemental lines of Al, Sr, and Ca all peaked at slightly different parameter settings, the strongest impact was found on the relative abundance of molecular AlO bands. Unlike in previous laser ablation molecular isotopic spectrometry (LAMIS) publications, the latter could be readily detected with a good intensity and well-resolved spectral features without any temporal gating of the detector. This finding, together with the fact that MOPA lasers are both inexpensive and dependable, makes for a promising combination for future studies including the detection of diatomic band structures. KW - Laser-induced breakdown spectroscopy KW - LIBS PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-583300 DO - https://doi.org/10.3389/fphy.2023.1241533 SN - 2296-424X VL - 11 SP - 1 EP - 8 AN - OPUS4-58330 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - van Wasen, S. A1 - You, Yi A1 - Beck, S. A1 - Riedel, Jens A1 - Volmer, D. A. T1 - Laser Ablation Secondary Electrospray Ionization for In Situ Mass Spectrometric Interrogation of Acoustically-Levitated Droplets N2 - The composition of acoustically levitated droplets was probed by a novel combination of mid-IR laser evaporation and subsequent postionization via secondary electrospray ionization. The combination of microliter samples and subnanoliter sampling provided time-resolved interrogation of droplets and allowed for a kinetic investigation of the laser-induced release of the analyte, which was found to strongly depend on the analytes. The observed substancespecific delayed release of the analytes permitted baseline-separated discrimination of the analytes, ideal for the study of complex samples. The additionally applied postionization scheme was found to enable efficient detection of small volatile compounds as well as peptides. The detection of small molecules and peptides occurred under very different sampling geometries, pointing to two distinct underlying ionization mechanisms. Overall, our results suggest that the experimental setup presented in this study can serve as a widely applicable platform to study chemical reactions in acoustically levitated droplets as model reactors. KW - Acoustic levitation KW - Mass spectrometry KW - Electrospray KW - Laser ablation PY - 2022 DO - https://doi.org/10.1021/acs.analchem.2c03800 SN - 0003-2700 VL - 2022 SP - 1 EP - 5 PB - ACS Publications CY - Washington AN - OPUS4-56531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xue, Boyang A1 - You, Yi A1 - Gornushkin, Igor B. A1 - Zheng, R. A1 - Riedel, Jens T1 - High-throughput underwater elemental analysis by μJ-laser-induced breakdown spectroscopy at kHz repetition rates: part I, ultrasound-enhanced optical emission spectroscopy towards application perspectives N2 - In recent years, laser-induced breakdown spectroscopy (LIBS) has gained significant attention as a means for simple elemental analyses. The suitability of LIBS for contactless analysis allows it to be a perfect candidate for underwater applications. While the majority of LIBS systems still rely upon sub-kHz pulsed lasers, this contribution introduces 10s-kHz low pulse-energy lasers into underwater LIBS to improve the throughput and statistical validity. Interestingly, the spectral component significantly changed above a critical laser repetition-rate threshold. Spectral lines of atomic hydrogen and oxygen stemming from water become visible beyond a ∼10 kHz repetition rate. This observation suggests a different plasma dynamic compared to low repetition rates. When the pulse-to-pulse interval becomes sufficiently short, a cumulative effect begins to be significant. Apparently, the new phenomena occur on a timescale corresponding to a threshold rate of ∼10 kHz, i.e. ∼100 μs. Analytically, the high repetition rates result in improved statistical validity and throughput. More plasma events per unit time allowed the use of low efficiency Echelle spectrometers without compromising on the analytical performance. Meanwhile, the presence of H I and O I out of the water (as the matrix) also offers internal standardization in underwater elemental analysis. Since the laser fluence was on the lower edge of the plasma threshold, an additional ultrasound source was introduced to induce external perturbation, which significantly improved the plasma formation stability. A huge advantage of LIBS is the possibility of detecting almost all elements within a sample simultaneously. Throughout the periodic table, chlorine is one of the most challenging elements. Consequently, Ca2+ and Na+ were used as samples to demonstrate the capability of this high repetition-rate LIBS platform. As an ambitious benchmark for our system, chlorine detection in water was also discussed. KW - High repetition rate KW - Laser-induced breakdown spectroscopy PY - 2020 DO - https://doi.org/10.1039/D0JA00290A VL - 35 IS - 12 SP - 2901 EP - 2911 PB - The Royal Society of Chemistry AN - OPUS4-51564 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xue, Boyang A1 - Wang, Zhangjun A1 - Zhu, Tao A1 - Gu, Yezhen A1 - Sun, Weihong A1 - Chen, Chao A1 - Li, Zhigang A1 - Riedel, Jens A1 - You, Yi T1 - High repetition-rate laser-induced breakdown spectroscopy combined with two-dimensional correlation method for analysis of sea-salt aerosols N2 - Laser-induced breakdown spectroscopy (LIBS) offers a tantalizing glimpse into real-time, on-the-spot aerosol analysis. Yet, the reliance on traditional lasers, with their limitations in energy and frequency, hampers optimal sample handling, dissociation, and excitation. To address those challenges, we propose a novel tactic: utilize a high repetition-rate (rep.-rate) laser with low pulse energy in combination with the two-dimensional correlation (2D-corr.) technique for sea-salt aerosols analyses. By examining the emission patterns from both the laser pulse train and individual pulses, we recognize distinctive analyte-specific rep.-rate responses, which allowed spectral reconstruction of analytes, avoiding background interferences. This discovery enabled the rep.-rate modulation for a 2D-corr. spectroscopy workflow. Consequently, we successfully differentiated between particle-related and air-species-related spectral components, obviating expensive spectrometers or intensified image detectors. For instance, the Na I at 589 nm stemming from aerosols exhibited an entirely different correlation contribution compared to O I at 777 nm, resulting in reconstructed clean aerosol-spectra without spectral peaks originated from air species. This 2D-corr. aerosol LIBS approach shows promising analytical potential streamlining aerosol particle analysis. KW - LIBS KW - Aerosol PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613392 DO - https://doi.org/10.1016/j.sab.2024.107048 SN - 0584-8547 VL - 221 SP - 1 EP - 8 PB - Elsevier AN - OPUS4-61339 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Li, Xunyu A1 - Riedel, Jens A1 - You, Yi T1 - Spectrally resolved lithium isotope quantification through high-resolution spatial heterodyne spectrometry N2 - Isotope ratio determination of lithium is increasingly important in fields ranging from geochemistry to battery diagnostics. While mass spectrometry remains the gold standard, it is costly, cumbersome, and incompatible with portable or inline implementations. Optical emission spectroscopy presents an appealing alternative. However, it is traditionally limited by insufficient spectral resolution or resolving power to separate lithium isotope emissions due to their generalized designs for a wide spectral range; this often requires overly complicated algorithms to overcome the instrumental drawbacks. (79) Results Here, we report a high-resolution optical method for lithium isotope quantification using a custom-built spatial heterodyne spectrometer (SHS) combined with a reduced-pressure glow discharge source. This configuration yielded a resolving power of 189,000 and enabled baseline resolution of lithium d-line emission features even without the need for preliminary data processing. Despite the inherent low sensitivity of SHS, a detection limit of 30 pmol was achieved using a standard industrial camera. To improve quantitative accuracy, we introduced a deconvolution-based spectral lineshape recovery technique alongside a bootstrapping-based error propagation strategy. These methods facilitated robust isotope ratio calibration using both peak-height and peak-area metrics. The SHS platform additionally enabled the determination of relative transition probabilities, suggesting the feasibility of calibration-free operation. This work demonstrates the practical viability of SHS for high-specificity, high-resolution lithium isotope analysis. The approach is compact, potentially field-deployable, and adaptable to other elements with optically resolvable isotope shifts, offering a route toward accessible and calibration-free optical isotopic analyses. KW - SHS KW - Isotope KW - High-resolution spectroscopy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635139 DO - https://doi.org/10.1016/j.aca.2025.344329 SN - 1873-4324 VL - 1368 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-63513 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mohan, M. A1 - Prochazka, D. A1 - You, Yi A1 - Riedel, Jens A1 - Gornushkin, Igor A1 - Rocnakova, I. A1 - Papula, M. A1 - Porízka, P. A1 - Kaizer, J. T1 - Investigating plasma morphology at material boundaries under varying ambient pressures N2 - Laser-Induced Breakdown Spectroscopy (LIBS) is a widely used technique for elemental analysis. The analysis of the obtained LIBS spectra generally assumes plasma homogeneity. However, using focused laser beams for interrogation, LIBS probes materials on the microscale and is, thus, prone to artefacts from sample heterogeneities on the micrometer scale. An ablation at a material boundary of two matrices may result in a significant inhomogeneity in the plasma plume, which can severely impact the accuracy of quantitative analysis. Since this propagation of the surface morphology into the plasma plume is driven by the plasma expansion, its final impact is strongly pressure dependent. This study examines the influence of varying ambient pressures (7–1000 mbar) on plasma morphology, spectral characteristics, and key plasma properties such as electron number density at a well-defined Cu–Sn boundary, in comparison with the results obtained using homogeneous alloys. Several approaches of plasma imaging with bandpass filters, spectroscopy, and Radon transform-based 3D reconstruction were employed to analyze elemental distribution, signal-to-noise (SNR) and signal-to-background (SBR) ratios, as well as electron number densities. The 3D reconstructions revealed a pronounced plasma asymmetry for the ablation at the material boundary, in contrast to the near-axial symmetry observed for the ablation of homogeneous alloys. At lower pressures, this distinct elemental separation in plasma persisted, while higher pressures led to an increased collisional mixing and homogenization. SNR and SBR were consistently lower for ablation at the boundary compared to homogeneous samples. These findings highlight how boundary ablation contributes to plasma inhomogeneities in LIBS analysis of heterogeneous materials and emphasize the need to account for these effects when using LIBS for elemental mapping of fine heterogeneous structures. KW - Laser-induced breakdown spectroscopy KW - Plasma inhomogeneity KW - Plasma tomography KW - Radon transform KW - Material boundaries KW - Ambient pressure effects PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-634777 DO - https://doi.org/10.1016/j.talanta.2025.128377 SN - 1873-3573 VL - 295 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-63477 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bierstedt, Andreas A1 - Warschat, Carsten A1 - You, Yi A1 - Rurack, Knut A1 - Riedel, Jens T1 - Stimulated Raman scattering by intracavity mixing of nanosecond laser excitation and fluorescence in acoustically levitated droplets N2 - Raman spectroscopy is becoming a commonly used, powerful tool for structural elucidation and species identification of small liquid samples, e.g. in droplet-based digital microfluidic devices. Due to the low scattering cross sections and the temporal restrictions dictated by the droplet flow, however, it depends on amplification strategies which often come at a cost. In the case of surface-enhanced Raman scattering (SERS), this can be an enhanced susceptibility towards memory effects and cross talk, whereas resonant and/or stimulated Raman techniques require higher instrumental sophistication, such as tunable lasers or the high electromagnetic field strengths which are typically provided by femtosecond lasers. Here, an alternative instrumental approach is discussed, in which stimulated Raman scattering (SRS) is achieved using the single fixed wavelength output of an inexpensive diode-pumped solid-state (DPSS) nanosecond laser. The required field strengths are realized by an effective light trapping in a resonator mode inside the interrogated droplets, while the resonant light required for the stimulation is provided by the fluorescence signal of an admixed laser dye. To elucidate the underlying optical processes, proof-of-concept experiments are conducted on acoustically levitated droplets, mimicking a highly reproducible and stable digital fluidic system. By using isotope-labeled compounds, the assignment of the emitted radiation as Raman scattering is firmly corroborated. A direct comparison reveals an amplification of the usually weak spontaneous Stokes emission by up to five orders of magnitude. Further investigation of the optical power dependence reveals the resulting gain to depend on the intensity of both, the input laser fluence and the concentration of the admixed fluorophore, leaving SRS as the only feasible amplification mechanism. While in this study stable large droplets have been studied, the underlying principles also hold true for smaller droplets, in which case significantly lower laser pulse energy is required. Since DPSS lasers are readily available with high repetition rates, the presented detection strategy bears a huge potential for fast online identification and characterization routines in digital microfluidic devices. KW - Ultrasonic levitation KW - Stimulated Raman Spectroscopy PY - 2020 DO - https://doi.org/10.1039/D0AY01504K VL - 12 IS - 42 SP - 5046 EP - 5054 PB - Royal Society of Chemistry AN - OPUS4-51566 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - LIBs–trends and developments for recycling applications N2 - Recent years have brought up many challenges for an analytical tracing of material flows. While planetary boundaries force end of life material into circular recycling pathways, geopolitical tension creates demands regarding the origin of raw materials. The analytical demands on any instrumentation to tackle the arising challenges of this scenario are straight forward: No sample preparation, precision in the percentage region, and high throughput at comparably low cost. All these demands make LIBS a perfect candidate, why it is time for a re-evaluation of how it exploits the potential possibilities arising from todays’ technology. While being a relatively young technique, the vast majority of conducted LIBS experiments still relies on well established instrumentation, sometimes ignoring the innovations and breakthroughs in the development of its empowering technology sectors such as battery powered compact high repetition rate lasers with tuneable pulse rate and length, low priced cameras with millions of small sized pixels and extremely fast shutter and readout times, optical modulators, galvonometer scanners, and simple robotics. In this talk we will showcase some examples on how the implantation of all these new tools can lead to extremely affordable and compact instrumentation with unprecedented acquisition speed and a spectral resolution sufficient to resolve atomic isotope lines. T2 - Institute Seminar CY - Rostock, Germany DA - 09.01.2024 KW - LIBS KW - Sorting KW - Automatisation PY - 2024 AN - OPUS4-62136 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Xue, Boyang A1 - You, Yi A1 - Riedel, Jens T1 - High-throughput underwater elemental analysis by μJ-laser-induced breakdown spectroscopy at a kHz repetition rate: part II, understanding the high repetition-rate from a fundamental perspective N2 - The technological advances in lasers enabled the wide application of laser-induced breakdown spectroscopy (LIBS) as a powerful analytical means for elemental analyses. Rather than commonly used lasers that operate at several to several-tens of Hz, the high repetition rate ones that operate at tens of kHz showed superior analytical advantages while implying unique excitation pathways. Specifically, the production of excited atomic hydrogen and oxygen, which can serve as internal standards, is quite different from that in commonly reported double-pulse LIBS. In this part of the work, it was found that the atomic emitters stemming from water are not related to cavitation bubbles. Moreover, the emitter productions of dissolved species, e.g., Na+, and water-related species, e.g., H-α, are two distinctive mechanisms. Towards analytical applications of the high repetition-rate system, the fundamental investigation can provide important guidelines to address real-life challenges. In this part of the work, the high repetition-rate regime of operation is explored from a more kinetic perspective. KW - High repetition rate KW - Laser-induced breakdown spectroscopy PY - 2020 DO - https://doi.org/10.1039/D0JA00291G VL - 35 IS - 12 SP - 2912 EP - 2919 PB - Royal Society of Chemistry AN - OPUS4-51565 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Yi A1 - Xue, Boyang A1 - Riedel, Jens T1 - Enhancement of LIBS plasma in air with organic solvent vapors N2 - Laser-induced breakdown spectroscopy (LIBS) offers versatile, field-deployable elemental analysis; however, compact, high-repetition-rate nanosecond laser systems typically face constraints in power consumption and size, often compromising emission intensity and thus analytical performance. We demonstrate a significant improvement in LIBS signals through the controlled introduction of common organic solvent vapors into a sheath gas, with a diode-pumped solid-state laser (1064 nm, 2–28 kHz repetition rate, 450–600-μJ pulse energy). Optical and acoustic diagnostics reveal up to ca. 40-fold enhancement of the N II emission line at 567 nm when ambient air serves as the analyte. Maximal enhancement occurs at intermediate repetition rates of ca. 15 kHz, particularly at pulse energies approaching the optical breakdown threshold; this observation suggests a viable strategy for operating LIBS at lower pulse energies and higher repetition rates. Enhancement effects scale jointly with both vapor pressure and ionization energy of the organic species, with acetone and toluene markedly outperforming methanol and isopropanol. These findings provide a rational foundation for significantly improving the analytical performance of portable LIBS instruments without exceeding platform-specific constraints. KW - LIBS PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653758 DO - https://doi.org/10.1016/j.sab.2025.107309 SN - 0584-8547 VL - 236 SP - 1 EP - 6 PB - Elsevier B.V. AN - OPUS4-65375 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stindt, Arne A1 - Buurman, Merwe A1 - Panne, Ulrich A1 - Riedel, Jens T1 - CO2 laser ionization of acoustically levitated droplets N2 - For many analytical purposes, direct laser ionization of liquids is desirable. Several studies on supported droplets, free liquid jets, and ballistically dispensed microdroplets have been conducted, yet detailed knowledge of the underlying mechanistics in ion formation is still missing. This contribution introduces a simple combination of IR-MALDI mass spectrometry and an acoustical levitation device for contactless confinement of the liquid sample. The homebuilt ultrasonic levitator supports droplets of several millimeters in diameter. These droplets are vaporized by a carbon dioxide laser in the vicinity of the atmospheric pressure interface of a time of flight mass spectrometer. The evaporation process is studied by high repetition rate shadowgraphy experiments elucidating the ballistic evaporation of the sample and revealing strong confinement of the vapor by the ultrasonic field of the trap. Finally, typical mass spectra for pure glycerol/water matrix and lysine as an analyte are presented with and without the addition of trifluoracetic acid, and the ionization mechanism is briefly discussed. The technique is a promising candidate for a reproducible mass spectrometric detection scheme for the field of microfluidics. KW - Ambient mass spectrometry KW - Levitated droplets KW - IR-MALDI PY - 2013 DO - https://doi.org/10.1007/s00216-012-6500-y SN - 1618-2642 SN - 1618-2650 N1 - Geburtsname von Buurman, Merwe: Albrecht, M. - Birth name of Buurman, Merwe: Albrecht, M. VL - 405 SP - 7005 EP - 7010 PB - Springer CY - Berlin AN - OPUS4-27429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Andrade, M. A. B. A1 - Stindt, Arne A1 - Panne, Ulrich A1 - Riedel, Jens A1 - Adamowski, J. C. T1 - Numerical and experimental determination of the sound pressure distribution in single-axis acoustic levitators N2 - This paper presents a numerical and an experimental procedure to obtain the pressure field in single-axis acoustic levitators. Numerically, the pressure field is determined by a matrix method based on the Rayleigh integral that take into account the multiple wave reflections that occur between the transducer and the reflector. The numerical pressure field is compared with the acoustic pressure measured by an earplug microphone, that is connected to a hollow needle. The tip of the needle is moved by a µm translation stage through the field and the signal is recorded using a lock-in amplifier locked to the levitator frequency. The pressure field obtained numerically show good agreement with that obtained experimentally. T2 - 2012 IEEE International Ultrasonics Symposium (IUS) CY - Dresden, Germany DA - 07.10.2012 KW - Acoustic levitation KW - Matrix method KW - Pressure field PY - 2012 SN - 978-1-4673-4562-0 DO - https://doi.org/10.1109/ULTSYM.2012.0690 SP - 2754 EP - 2757 PB - Institute of Electrical and Electronics Engineers (IEEE) CY - Piscataway, NJ AN - OPUS4-32587 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Michalik-Onichimowska, Aleksandra A1 - Beitz, T. A1 - Panne, Ulrich A1 - Löhmannsröben, H.-G. A1 - Riedel, Jens T1 - Laser ionization ion mobility spectrometric interrogation of acoustically levitated droplets N2 - Acoustically levitated droplets have been suggested as compartmentalized, yet wall-less microreactors for high-throughput reaction optimization purposes. The absence of walls is envisioned to simplify up-scaling of the optimized reaction conditions found in the microliter volumes. A consequent pursuance of high-throughput chemistry calls for a fast, robust and sensitive analysis suited for online interrogation. For reaction optimization, targeted Analysis with relatively low sensitivity suffices, while a fast, robust and automated sampling is paramount. To follow this approach, in this contribution, a direct coupling of levitated droplets to a homebuilt ion mobility spectrometer (IMS) is presented. The sampling, Transfer to the gas phase, as well as the ionization are all performed by a single exposure of the sampling volume to the resonant output of a mid-IR laser. Once formed, the nascent spatially and temporally evolving analyte ion cloud needs to be guided out of the acoustically confined trap into the inlet of the ion mobility spectrometer. Since the IMS is operated at ambient pressure, no fluid dynamic along a pressure Gradient can be employed. Instead, the transfer is achieved by the electrostatic potential gradient inside a dual ring electrode ion optics, guiding the analyte ion cloud into the first stage of the IMS linear drift tube accelerator. The design of the appropriate atmospheric pressure ion optics is based on the original vacuum ion optics design of Wiley and McLaren. The obtained experimental results nicely coincide with ion trajectory calculations based on a collisional model. KW - Ambient pressure laser ionization KW - Ionmobility spectrometry KW - Acoustic levitation KW - ion optics PY - 2019 DO - https://doi.org/10.1007/s00216-019-02167-5 VL - 411 IS - 30 SP - 8053 EP - 8061 PB - Springer CY - Heidelberg AN - OPUS4-50132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Schwaar, Timm A1 - Springer, A. A1 - Grabarics, M. A1 - Riedel, Jens A1 - Beck, S. A1 - Pagel, K. A1 - Linscheid, M. W. T1 - Comparison of the fragmentation behavior of DNA and LNA single strands and duplexes N2 - DNA and locked nucleic acid (LNA) were characterized as single strands, as well as double stranded DNA-DNA duplexes and DNA-LNA hybrids using tandem mass spectrometry with collision-induced dissociation. Additionally, ion mobility spectrometry was carried out on selected species. Oligonucleotide duplexes of different sequences – bearing mismatch positions and abasic sites of complementary DNA 15-mers – were investigated to unravel general trends in their stability in the gas phase. Single stranded LNA oligonucleotides were also investigated with respect to their gas phase behavior and fragmentation upon collision-induced dissociation. In contrast to the collision-induced dissociation of DNA, almost no base loss was observed for LNAs. Here, backbone cleavages were the dominant dissociation pathways. This finding was further underlined by the need for higher activation energies. Base losses from the LNA strand were also absent in fragmentation experiments of the investigated DNA-LNA hybrid duplexes. While DNA-DNA duplexes dissociated easily into single stranded fragments, the high stability of DNA-LNA hybrids resulted in predominant fragmentation of the DNA part rather than the LNA, while base losses were only observed from the DNA single strand of the hybrid. KW - Oligonucleotide fragmentation KW - Locked nucleic acids KW - Collision induced dissociation (CID) KW - Double strands KW - Ion mobility spectrometry PY - 2019 DO - https://doi.org/10.1002/jms.4344 VL - 54 IS - 5 SP - 402 EP - 411 PB - Wiley AN - OPUS4-47485 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Beck, S. A1 - Linscheid, M. A1 - Riedel, Jens T1 - VUV Photodissociation Induced by a Deuterium Lamp in an Ion Trap N2 - Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability. KW - Fragmentation activation KW - Vacuum ultraviolet (VUV) light KW - Mass spectrometry KW - Tandem MS PY - 2019 DO - https://doi.org/10.1007/s13361-019-02282-8 SN - 1044-0305 VL - 30 IS - 10 SP - 2114 EP - 2122 PB - Springer Nature CY - Heidelberg AN - OPUS4-48756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bayerlein, Bernd A1 - Hanke, T. A1 - Muth, Thilo A1 - Riedel, Jens A1 - Schilling, Markus A1 - Schweizer, C. A1 - Skrotzki, Birgit A1 - Todor, A. A1 - Moreno Torres, Benjami A1 - Unger, Jörg F. A1 - Völker, Christoph A1 - Olbricht, Jürgen T1 - A Perspective on Digital Knowledge Representation in Materials Science and Engineering N2 - The amount of data generated worldwide is constantly increasing. These data come from a wide variety of sources and systems, are processed differently, have a multitude of formats, and are stored in an untraceable and unstructured manner, predominantly in natural language in data silos. This problem can be equally applied to the heterogeneous research data from materials science and engineering. In this domain, ways and solutions are increasingly being generated to smartly link material data together with their contextual information in a uniform and well-structured manner on platforms, thus making them discoverable, retrievable, and reusable for research and industry. Ontologies play a key role in this context. They enable the sustainable representation of expert knowledge and the semantically structured filling of databases with computer-processable data triples. In this perspective article, we present the project initiative Materials-open-Laboratory (Mat-o-Lab) that aims to provide a collaborative environment for domain experts to digitize their research results and processes and make them fit for data-driven materials research and development. The overarching challenge is to generate connection points to further link data from other domains to harness the promised potential of big materials data and harvest new knowledge. KW - Data infrastructures KW - Digital representations KW - Digital workflows KW - Knowledge graphs KW - Materials informatics KW - Ontologies KW - Vocabulary providers PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-546729 DO - https://doi.org/10.1002/adem.202101176 SN - 1438-1656 SP - 1 EP - 14 PB - Wiley-VCH GmbH CY - Weinheim AN - OPUS4-54672 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Li, Xunyu A1 - Riedel, Jens A1 - You, Yi T1 - Determination of broadband-light atomic absorption through interferometric spectrometry with a spatial heterodyne spectrometer N2 - A spatial heterodyne spectrometer (SHS) was combined with a flame atomic absorption (FAA) setup to reveal the analytical potential of SHS to be used as a tool for high-resolution atomic absorption studies. Exploiting the advances in modern computational power, the spectral information encoded in the interferograms was extracted and separated. Consequently, unseeable interferometric ingredients corresponding to narrow-band absorption lines could be recognized. Namely, a single SHS absorption interferogram simultaneously contains both illumination background and absorption information, which can be distinguished through a series of computational steps. In the examples given by this work, we demonstrate the construction of Na absorbance spectra from a single image. The described single-image approach can be used to investigate highly dynamic systems, whereby background collections can be obviated. KW - Optical Spectrometry KW - Spatial Heterodyne Spectrometry KW - Atomic Absorption PY - 2023 DO - https://doi.org/10.1039/D2JA00367H VL - 38 IS - 5 SP - 1088 EP - 1096 PB - Royal Society of Chemistry (RSC) AN - OPUS4-58332 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Acoustic Ion Manipulation: Electric-field-free Approach to Gate, Focus, and Separate Ions at Atmospheric Pressure N2 - Approaches to control the motion and direction of ionized particles and mole-cules are an essential aspect of ion-based spectrometries, such as mass spec-trometry (MS) and ion mobility spectrometry (IMS). A wide variety of ion optics exist to reflect, focus, separate, gate, and filter ions based on physical proper-ties. Notably all rely on electric and magnetic fields to alter the trajectory of ionized atoms and molecules. While these optics are quite efficient at low pressures due to the large mean free path, diffusion and electrostatic repulsion between ions dominate at higher pressures. Conventional ion optics, that use electric or magnetic fields, can guide ions at atmospheric pressure (AP), but require high field strengths to overcome the dominating aerodynamic effects. Here, we describe a remarkable phenomenon whereby low-power acoustic fields are used to move, shape, gate, and separate beams of gaseous ions at atmospheric pressure. We refer to this approach as Acoustic Ion Manipulation (AIM). Gaseous ions at AP are directed towards and separated by the presence of the acoustic field. To better understand the phenomenon, an ion-detector array provided a measure of bulk ion movement, while mass spectrometry (MS) offered chemical-specific information. As one example of an AIM setup, a standing acoustic wave was formed with two ultrasonic speakers and placed between an ionization source and ion detector. Ion beams preferentially travel through regions of stable pressure gradients (i.e. nodes) and deflect from un-stable regions (i.e. antinodes). Shadowgraphy revealed that the ions are sepa-rated from a neutral gas stream. Specific examples of ion focusing, gating, and separation (based on ion size) will be shown. In addition, experimental findings will be used to postulate a theory to develop a better understand of the behav-ior of gas-phase ions in acoustic fields. This discovery could have profound im-pacts in IMS/MS instrumentation as well as materials processing and charac-terization. T2 - 56. Jahrestagung der DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - Acoustic Ion Manipulation KW - Mass spectrometry KW - Ultrasound PY - 2025 AN - OPUS4-64208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Danischewski, Julia L. A1 - You, Yi A1 - Bauer, Lauren A1 - Riedel, Jens A1 - Shelley, Jacob T. T1 - Use of Resonant Acoustic Fields as Atmospheric-Pressure Ion Gates N2 - Ion optics are crucial for spectrometric methods such as mass spectrometry (MS) and ion mobility spectrometry (IMS). Among the wide selection of ion optics, temporal ion gates are of particular importance for time-of-flight MS (TOF-MS) and drift-tube IMS. Commonly implemented as electrostatic ion gates, these optics offer a rapid, efficient means to block ion beams and form discrete ion packets for subsequent analysis. Unfortunately, these devices rely on pulsed high voltage sources and are not fully transparent, even in their open state, which can lead to ion losses and contamination. Here, a novel atmospheric-pressure ion gate based on a resonant acoustic field structure is described. This effect was accomplished through the formation of a resonant, standing acoustic wave of alternating nodes and antinodes. Alignment of an atmospheric-pressure gaseous ion beam with an antinode, i.e. a region of transient pressure, of the acoustic structure acted as a gate and blocked ions from impinging on ion-selective detectors, such as a mass spectrometer and a Faraday plate. The velocity of the ion stream and acoustic power were found to be critical parameters for gating efficiency. In the presence of an acoustic field (i.e., a closed gate), ion signals decreased by as much as 99.8% with a response time faster than the readout of the ion-measurement devices used here (ca. 75 ms). This work demonstrates the basis for a low-cost, acoustic ion gate, which is optically transparent and easily constructed with low-power, off-the-shelf components, that could potentially be used with MS and IMS instrumentation. KW - Acoustic Ion Manipulation PY - 2025 DO - https://doi.org/10.1021/acs.analchem.4c05493 SN - 1520-6882 VL - 97 IS - 5 SP - 2890 EP - 2898 PB - American Chemical Society AN - OPUS4-62648 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Airborne Laser-Induced Plasma as an Ambient Desorption/Ionization Source for Mass Spectrometry and its Characterization N2 - Laser-induced plasma (LIP) has drawn significant amount of attentions in the past decades, particular in elemental analyses for solid or liquid samples. Through proper focusing of the highly energetic laser beam, the plasma can also be ignited in the ambient air, where airborne analytes can be ionized. Such an effect enabled the use of airborne LIP as an ambient ionization source for mass spectrometric analyses. In contrast to other ambient desorption/ionization sources, airborne LIP does not require a specific discharge medium or expensive gas stream. Meanwhile, the airborne LIP produces reagent ion species for both proton-transfer and charge-transfer reactions in addition to the vacuum ultraviolent photons that are capable of promoting single photon ionization, which can be utilized to ionize polar and non-polar analytes. In order to gauge the analytical performance of airborne LIP, it is critical to understand the undergoing chemistry and physics during and after the plasma formation. Due to the ambient nature of airborne LIP, the variations of air composition and flow strongly affect the plasma behaviors. Preliminary result suggested the addition of a laminar flow of nitrogen gas favored the formation of protonated species (MH+) against the molecular ones (M+). Although the gas addition approach cannot fully tune the ionization process towards the specific production of pseudo-molecular species versus molecular ones, the alternation of molecular ion formation can be used for analyte recognitions through post processing of the ion patterns. The pulsed character of the used lasers makes the reagent ion equilibrium both transient- and highly fluid-dynamically controlled. The acoustic shock-waves induced by the airborne LIP get affected by an applied gas streams towards the plasma center, influencing the molecular-ion and ion-ion interactions in the near proximity of the plasma. To understand the airborne LIP formation, the temporally and spatially resolved optical emission spectra were recorded. The results will be correlated to time-resolved mass-spectrometric investigations of the ion profile during different stages of the plasma formation. As one example, the formation of pyrylium ion originating from aromatic compounds will be highlighted. T2 - SciX 2018 CY - Atlanta, GA, USA DA - 21.10.2018 KW - Laser-Induced Plasma KW - Ambient Desorption/Ionization KW - Mass Spectrometry KW - Characterization PY - 2018 AN - OPUS4-46376 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bierstedt, Andreas A1 - You, Yi A1 - van Wasen, Sebastian A1 - Bosc-Bierne, Gaby A1 - Weller, Michael G. A1 - Riedel, Jens T1 - Laser-Induced Microplasma as an Ambient Ionization Approach for the Mass-Spectrometric Analysis of Liquid Samples N2 - An airborne high repetition rate laser-induced plasma was applied as a versatile ambient ionization source for mass-spectrometric determinations of polar and nonpolar analytes in solution. The laser plasma was sustained between a home-built pneumatic nebulizer and the inlet capillary of an Orbitrap mass spectrometer. To maintain stable conditions in the droplet-rich spray environment, the plasma was directly fed by the fundamental output (λ = 1064 nm) of a current state-of-the-art diode-pumped solid-state laser. Ionization by the laser-driven plasma resulted in signals of intact analyte ions of several chemical categories. The analyte ions were found to be fully desolvated since no further increase in ion signal was observed upon heating of the inlet capillary. Due to the electroneutrality of the plasma, both positive and negative analyte ions could be formed simultaneously without altering the operational parameters of the ion source. While, typically, polar analytes with pronounced gas phase basicities worked best, nonpolar and amphoteric compounds were also detected. The latter were detected with lower ion signals and were prone to a certain degree of fragmentation induced during the ionization process. All the described attests the laser-induced microplasma by a good performance in terms of stability, robustness, sensitivity, and general applicability as a self-contained ion source for the liquid sample introduction. KW - Laser KW - Laser-induced plasma KW - Ambient ionization KW - Mass Spectrometry PY - 2019 DO - https://doi.org/10.1021/acs.analchem.9b00329 SN - 0003-2700 VL - 91 IS - 9 SP - 5922 EP - 5928 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-47939 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -