TY - JOUR A1 - Shelley, J.T. A1 - Stindt, Arne A1 - Riedel, Jens A1 - Engelhard, C. T1 - Time-resolved mass-spectral characterization of ion formation from a low-frequency, low-temperature plasma probe ambient ionization source N2 - New-found interest in the development of ionization sources for mass spectrometry, inspired by the advent of ambient desorption/ionization mass spectrometry, has led to a resurgence in plasma-source development and characterization. Dielectric-barrier discharges, particularly the low-temperature plasma (LTP) probe format, have been at the forefront of this field due to their low power consumption and relatively simple design. However, better fundamental understanding of this desorption/ionization source is needed to improve the analytical capabilities of such a device. Here, we use relatively fast (2.5 ms per spectrum) time-resolved mass spectrometry to characterize the temporal reagent-ion distribution from a low-frequency LTP probe. Different voltage waveforms were found to heavily influence the discharge properties and, consequently, ion production. Ion signals from short discharge pulses, ca. 40 µs, were found to be significantly broadened, ca. 10 ms, prior to extraction into the mass spectrometer. Additionally, higher frequencies of a sine-wave LTP produced the largest flux of reagent ions, which existed for most of the voltage waveforms. Finally, temporal signals for reagent and analyte ions were measured and related to specific ionization processes: proton transfer and charge transfer. KW - Time resolved KW - Mass spectrometry KW - Time of flight KW - Dielectric barrier discharge KW - Plasma KW - Atmospheric-pressure KW - Emission-spectrometry KW - Surface treatment PY - 2014 DO - https://doi.org/10.1039/c3ja50318f SN - 0267-9477 SN - 1364-5544 VL - 29 IS - 2 SP - 359 EP - 366 PB - Royal Society of Chemistry CY - London AN - OPUS4-30404 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - van Wasen, S. A1 - You, Yi A1 - Beck, S. A1 - Riedel, Jens A1 - Volmer, D. A. T1 - Miniaturized Protein Digestion Using Acoustic Levitation with Online High Resolution Mass Spectrometry N2 - The combination of acoustically levitated droplets, mid-IR laser evaporation, and subsequent post-ionization by secondary electrospray ionization was applied for monitoring the enzymatic digestion of various proteins. Acoustically levitated droplets are an ideal, wall-free model reactor, readily allowing compartmentalized microfluidic trypsin digestions. Time-resolved interrogation of the droplets yielded real-time information on the progress of the reaction and thus provided insights into reaction kinetics. After 30 min of digestion in the acoustic levitator, the obtained protein sequence coverages were identical to the reference overnight digestions. Importantly, our results clearly demonstrate that the applied experimental setup can be used for the real-time investigation of chemical reactions. Furthermore, the described methodology only uses a fraction of the typically applied amounts of solvent, analyte, and trypsin. Thus, the results exemplify the use of acoustic levitation as a green analytical chemistry alternative to the currently used batch reactions. KW - Acoustic levitation KW - Protein analysis KW - Mass spectrometry PY - 2023 DO - https://doi.org/10.1021/acs.analchem.2c05334 VL - 95 SP - 4190 EP - 4195 PB - ACS Publications AN - OPUS4-57053 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Alcalde-Vasquez, R. A1 - Moreno-Pedraza, A. A1 - Rosas-Román, I. A1 - Guillén-Alonso, H. A1 - Riedel, Jens A1 - Partida-Martínez, L. P. A1 - Winkler, R. T1 - MoBiMS: A Modular Miniature Mass Analyzer for the Real-Time 2 Monitoring of Gases and Volatile Compounds in Biological Systems N2 - Living organisms constantly interact with their environment, including through the exchange of gases. Respiration and the release and uptake of volatile organic compounds (VOCs) create dynamic microenvironments in biological systems. Studying the kinetics of volatiles in biological systems requires expensive instruments, and data analysis is challenging. Therefore, we aimed to design a minimal analytical device for measuring the composition of gaseous mixtures in realtime. We built the ‘Modular Biological Mass Spectrometer’ (MoBiMS) from 3D-printed parts and custom sensors to fit a wide array of experimental set-ups. We tested the chemical detection range and temporal resolution of the MoBiMS employing pure compounds and complex biological samples. Compounds with a higher than 0.4 mmHg vapor pressure and a molecular weight up to 154 g/mol were reliably sensed within seconds. The generated electron impact (EI) spectra were directly comparable with standard databases like the NIST EI library. Under a direct analysis approach, the MoBiMS identified the characteristic odor of banana (Musa sp.), that is, isoamyl acetate; tracked the dynamics of CO2 release while the Alka-Seltzer® reaction occurred showed the kinetics of the transient production and consumption of carbon dioxide during photosynthesis. MoBiMS also discriminated between volatile compounds ions coming from tobacco (Nicotiana benthamiana) leaves and the surrounding air through untargeted analysis. The small footprint of the MoBiMS and its relatively low energy consumption facilitate in situ analyses, as an additional gas supply is not necessary with EI ionization. The MoBiMS is easy to assemble, and its construction and operation are very cost-efficient compared to commercial devices. The analytical performance of the MoBiMS is suitable for real-time studies of biological systems, environmental monitoring, and medical diagnostics. KW - Mass spectrometry KW - Instrumentation KW - Miniaturization KW - Volatiles PY - 2022 DO - https://doi.org/10.1016/j.microc.2021.107090 SN - 0026-265X VL - 175 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-56528 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Hofmann, J. A1 - Riedel, Jens A1 - Beck, S. A1 - Pagel, K. A1 - Linscheid, M. W. T1 - Charge-induced geometrical reorganization of DNA oligonucleotides studied by tandem mass spectrometry and ion mobility N2 - Mass spectrometry is applied as a tool for the elucidation of molecular structures. This premises that gas-phase structures reflect the original geometry of the analytes, while it requires a thorough understanding and investigation of the forces controlling and affecting the gas-phase structures. However, only little is known about conformational changes of oligonucleotides in the gas phase. In this study, a series of multiply charged DNA oligonucleotides (n¼15–40) has been subjected to a comprehensive tandem mass spectrometric study to unravel transitions between different ionic gas-phase structures. The nucleobase sequence and the chain length were varied to gain insights into their influence on the geometrical oligonucleotide organization. Altogether, 23 oligonucleotides were analyzed using collision-induced fragmentation. All sequences showed comparable correlation regarding the characteristic collision energy. This value that is also a measure for stability, strongly correlates with the net charge density of the precursor ions. With decreasing charge of the oligonucleotides, an increase in the fragmentation energy was observed. At a distinct charge density, a deviation from linearity was observed for all studied species, indicating a structural reorganization. To corroborate the proposed geometrical change, collisional cross-sections of the oligonucleotides at different charge states were determined using ion mobility-mass spectrometry. The results clearly indicate that an increase in charge density and thus Coulomb repulsion results in the transition from a folded, compact form to elongated structures of the precursor ions. Our data show this structural transition to depend mainly on the charge density, whereas sequence and size do not have an influence. KW - Ion mobility KW - Collision-induced dissociation KW - Mass spectrometry KW - Oligonucleotide KW - Fragmentation KW - Tandem-MS PY - 2018 DO - https://doi.org/10.1177/1469066717746896 SN - 1469-0667 SN - 1751-6838 VL - 24 IS - 2 SP - 225 EP - 230 PB - Sage AN - OPUS4-44429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Airborne laser spark ionization N2 - A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities. The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions. For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highly-excited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization. These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event. T2 - SCIX 2017 CY - Reno, Nevada, USA DA - 08.10.2017 KW - Ambient ionization KW - Mass spectrometry KW - Laser KW - Plasma PY - 2017 UR - https://www.scixconference.org/program/final-program?symposium=17ACS01&p=8810/#session AN - OPUS4-42609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Airborne laser spark ionization N2 - A novel ionization scheme for ambient mass spectrometry is presented and discussed. Desorption and ionization are achieved by a quasi-continuous laser induced plasma (LIP) ignited in front of the atmospheric pressure interface of a time-of-flight mass spectrometer. This setup comprises the advantages of i) an ambient probe, ii) electro neutrality, iii) low power consumption, iv) a sufficient duty cycle, v) a ubiquitous plasma medium (air) and vi) high sensitivity caused by the high electron number densities. The plasma properties and operating conditions are investigated to understand the processes that lead to the formation of molecular ions. Comprehensive studies include optical emission spectroscopy, shadowgraphic shockwave visualization and time-of-flight mass spectrometry investigations. The observed MS signal (including reagent-ion signal, as well as analyte spectra) closely resembles the ionization behavior of other electrically-driven plasma-based ionization sources, such as DBD, LTP or DART. Conversely that means that although LIPs are commonly known to have temperatures way above 10.000 K and thus efficiently atomize and ionize molecules, MS spectra were obtained that showed the formation of intact molecular ions. For an insight into the LIP properties the optical emission of the LIP is examined and exhibits a pronounced degree of dissociation into atomic and ionic species, which reflects the higher temperature and electron density inside a LIP. Accordingly, rather elemental (ICP-type) than molecular spectra should be expected. However due to the absence of such ions, we conclude that the analyte does not enter the hot center of the plasma itself. Moreover, the initial, highlyexcited plasma species react cascade-like to lower energetic species via reactive collision with the surrounding atmosphere, which can then subsequently ionize molecules of interest. The concept potentially involves charge transfer, proton transfer, electron impact and photoionization. These assumptions are confirmed via the shadowgraphs of the expanding shockwave around the LIP. An effective spatial separation between the two regions is maintained by concentrically expanding pressure waves resulting in a strongly unidirectional diffusion. Additionally, the strictly outbound matter transport suggests a rarefaction inside the plasma region for each plasma event. T2 - IPOIMS CY - Menorca, Spain DA - 16.10.2017 KW - Laser KW - Ambient ionization KW - Plasma KW - Mass spectrometry PY - 2017 UR - http://ipoims.com/downloads/Abstracts_IPOIMS_10102017.pdf AN - OPUS4-42610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stindt, Arne A1 - Warschat, Carsten A1 - Bierstedt, Andreas A1 - Panne, Ulrich A1 - Riedel, Jens T1 - Characterisation of an inexpensive sonic spray ionisation source using laser induced fluorescence imaging and mass spectrometry N2 - A commercially available airbrush gun as a new source for spray ionization is presented. It is best operated employing moderate stagnation pressures, resulting in a sonic gas flow. A mass spectrometric investigation on the amino acid lysine and several peptides reveals that this inexpensive approach results in reproducible mass spectra. The ion patterns strongly resemble the results from other studies obtained with custom made sonic spray vaporizers. The patterns as well resemble the mass spectra recorded with electrospray devices. For a better understanding of the vaporization process, the mass spectrometry experiments are accompanied by laser induced fluorescence experiments. Inverse Abel transform of the obtained fluorescence maps allows the determination of the full 3D distribution of the spray cone. Furthermore, via exploitation of the solvatochromism of the used dye the solvation state distribution can be visualized. In addition, expansion parameters like droplet size and velocity are obtained by laser stroboscopy. The experiments demonstrate that the analyte is hardly desolvated throughout the expansion. This indicates a subsequent vaporization of the residual solvent in the intermediate pressure region of the mass spectrometer. KW - Sonic spray ionization KW - Mass spectrometry KW - Solvatochromism KW - Inverse Abel Transform KW - Sonic spray KW - Airbrush KW - Laser induced fluorescence PY - 2014 DO - https://doi.org/10.1255/ejms.1242 SN - 1469-0667 SN - 1356-1049 SN - 1365-0718 VL - 20 IS - 1 SP - 21 EP - 29 PB - IM Publications CY - Chichester AN - OPUS4-30403 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Yi A1 - Danischewski, Julia A1 - Molnar, Brian A1 - Riedel, Jens A1 - Shelley, Jacob T1 - Manipulation of Gaseous Ions with Acoustic Fields at Atmospheric Pressure N2 - The ability to controllably move gaseous ions is an essential aspect of ion-based spectrometry (e.g., mass spectrometry and ion mobility spectrometry) as well as materials processing. At higher pressures, ion motion is largely governed by diffusion and multiple collisions with neutral gas molecules. Thus, high-pressure ion optics based on electrostatics require large fields, radio frequency drives, complicated geometries, and/or partially transmissive grids that become contaminated. Here, we demonstrate that low-power standing acoustic waves can be used to guide, block, focus, and separate beams of ions akin to electrostatic ion optics. Ions preferentially travel through the static-pressure regions (“nodes”) while neutral gas does not appear to be impacted by the acoustic field structure and continues along a straight trajectory. This acoustic ion manipulation (AIM) approach has broad implications for ion manipulation techniques at high pressure, while expanding our fundamental understanding of the behavior of ions in gases. KW - Ion mobility spectrometry KW - Acoustic KW - Mass spectrometry PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-600704 DO - https://doi.org/10.1021/jacs.4c01224 SP - 1 EP - 6 PB - ACS Publications AN - OPUS4-60070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - van Wasen, S. A1 - You, Yi A1 - Beck, S. A1 - Riedel, Jens A1 - Volmer, D. A. T1 - Laser Ablation Secondary Electrospray Ionization for In Situ Mass Spectrometric Interrogation of Acoustically-Levitated Droplets N2 - The composition of acoustically levitated droplets was probed by a novel combination of mid-IR laser evaporation and subsequent postionization via secondary electrospray ionization. The combination of microliter samples and subnanoliter sampling provided time-resolved interrogation of droplets and allowed for a kinetic investigation of the laser-induced release of the analyte, which was found to strongly depend on the analytes. The observed substancespecific delayed release of the analytes permitted baseline-separated discrimination of the analytes, ideal for the study of complex samples. The additionally applied postionization scheme was found to enable efficient detection of small volatile compounds as well as peptides. The detection of small molecules and peptides occurred under very different sampling geometries, pointing to two distinct underlying ionization mechanisms. Overall, our results suggest that the experimental setup presented in this study can serve as a widely applicable platform to study chemical reactions in acoustically levitated droplets as model reactors. KW - Acoustic levitation KW - Mass spectrometry KW - Electrospray KW - Laser ablation PY - 2022 DO - https://doi.org/10.1021/acs.analchem.2c03800 SN - 0003-2700 VL - 2022 SP - 1 EP - 5 PB - ACS Publications CY - Washington AN - OPUS4-56531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Beck, S. A1 - Linscheid, M. A1 - Riedel, Jens T1 - VUV Photodissociation Induced by a Deuterium Lamp in an Ion Trap N2 - Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability. KW - Fragmentation activation KW - Vacuum ultraviolet (VUV) light KW - Mass spectrometry KW - Tandem MS PY - 2019 DO - https://doi.org/10.1007/s13361-019-02282-8 SN - 1044-0305 VL - 30 IS - 10 SP - 2114 EP - 2122 PB - Springer Nature CY - Heidelberg AN - OPUS4-48756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Riedel, Jens T1 - Acoustic Ion Manipulation: Electric-field-free Approach to Gate, Focus, and Separate Ions at Atmospheric Pressure N2 - Approaches to control the motion and direction of ionized particles and mole-cules are an essential aspect of ion-based spectrometries, such as mass spec-trometry (MS) and ion mobility spectrometry (IMS). A wide variety of ion optics exist to reflect, focus, separate, gate, and filter ions based on physical proper-ties. Notably all rely on electric and magnetic fields to alter the trajectory of ionized atoms and molecules. While these optics are quite efficient at low pressures due to the large mean free path, diffusion and electrostatic repulsion between ions dominate at higher pressures. Conventional ion optics, that use electric or magnetic fields, can guide ions at atmospheric pressure (AP), but require high field strengths to overcome the dominating aerodynamic effects. Here, we describe a remarkable phenomenon whereby low-power acoustic fields are used to move, shape, gate, and separate beams of gaseous ions at atmospheric pressure. We refer to this approach as Acoustic Ion Manipulation (AIM). Gaseous ions at AP are directed towards and separated by the presence of the acoustic field. To better understand the phenomenon, an ion-detector array provided a measure of bulk ion movement, while mass spectrometry (MS) offered chemical-specific information. As one example of an AIM setup, a standing acoustic wave was formed with two ultrasonic speakers and placed between an ionization source and ion detector. Ion beams preferentially travel through regions of stable pressure gradients (i.e. nodes) and deflect from un-stable regions (i.e. antinodes). Shadowgraphy revealed that the ions are sepa-rated from a neutral gas stream. Specific examples of ion focusing, gating, and separation (based on ion size) will be shown. In addition, experimental findings will be used to postulate a theory to develop a better understand of the behav-ior of gas-phase ions in acoustic fields. This discovery could have profound im-pacts in IMS/MS instrumentation as well as materials processing and charac-terization. T2 - 56. Jahrestagung der DGMS CY - Göttingen, Germany DA - 04.03.2025 KW - Acoustic Ion Manipulation KW - Mass spectrometry KW - Ultrasound PY - 2025 AN - OPUS4-64208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -