TY - JOUR A1 - Meyer, S. A1 - Timmel, S. A1 - Richter, S. A1 - Werner, M. A1 - Gläser, M. A1 - Swatek, S. A1 - Braun, Ulrike A1 - Hagendorf, C. T1 - Silver nanoparticles cause snail trails in photovoltaic modules N2 - After some months of operation, a number of PV modules develop a discolouration defect called 'snail trails', or 'snail traces', which appear as irregular dark stripes across the cells. Whereas these traces were soon identified as discoloured silver contacts along the cell edges or at micro cracks, the chemical and mechanistic reasons for this phenomenon have not yet been resolved in detail. In this work we show that silver nanoparticles accumulating within the encapsulation foil cause the brownish discolouration, and that certain additives of encapsulation and back sheet foils trigger the formation of these nanoparticles. KW - Snail trails KW - Cell cracks KW - Encapsulation foil KW - Ag contact finger KW - Nanoparticles PY - 2014 DO - https://doi.org/10.1016/j.solmat.2013.11.013 SN - 0927-0248 VL - 121 SP - 171 EP - 175 PB - Elsevier B.V. CY - Amsterdam [u.a.] AN - OPUS4-30059 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Meyer, S. A1 - Richter, S. A1 - Balski, Matthias A1 - Hagendorf, C. ED - Thirsk, M. T1 - Trace element analysis in crystalline silicon N2 - The reliable analysis of trace elements in silicon is of fundamental importance for the understanding of material properties and quality control of solar cells. This paper presents a demonstration of the power of two analytical techniques for the determination of trace elements in solar silicon: inductively coupled plasma mass spectrometry (ICP-MS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). These techniques are among the few that achieve sufficiently low detection limits and they may complement each other because of their specific performance. Examples are given of the quantitative chemical analysis of boron, phosphorus and iron in different types of solar silicon, as well as of the enrichment of metals and alkali metals in Si3N4 precipitates. PY - 2013 SN - 978-0-9565331-3-5 SP - 34 EP - 38 PB - Photovoltaics International CY - London, UK AN - OPUS4-29823 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Heinrich, Thomas A1 - Traulsen, Christoph Hans-Henning A1 - Holzweber, Markus A1 - Richter, S. A1 - Kunz, V. A1 - Kastner, S.K. A1 - Krabbenborg, S.O. A1 - Huskens, J. A1 - Unger, Wolfgang A1 - Schalley, C.A. T1 - Coupled molecular switching processes in ordered mono- and multilayers of stimulus-responsive rotaxanes on gold surfaces N2 - Interfaces provide the structural basis for function as, for example, encountered in nature in the membrane-embedded photosystem or in technology in solar cells. Synthetic functional multilayers of molecules cooperating in a coupled manner can be fabricated on surfaces through layer-by-layer self-assembly. Ordered arrays of stimulus-responsive rotaxanes undergoing well-controlled axle shuttling are excellent candidates for coupled mechanical motion. Such stimulus-responsive surfaces may help integrate synthetic molecular machines in larger systems exhibiting even macroscopic effects or generating mechanical work from chemical energy through cooperative action. The present work demonstrates the successful deposition of ordered mono- and multilayers of chemically switchable rotaxanes on gold surfaces. Rotaxane mono- and multilayers are shown to reversibly switch in a coupled manner between two ordered states as revealed by linear dichroism effects in angle-resolved NEXAFS spectra. Such a concerted switching process is observed only when the surfaces are well packed, while less densely packed surfaces lacking lateral order do not exhibit such effects. KW - Molecular machine KW - Rotaxane KW - LBL growth KW - XPS KW - NEXAFS KW - SIMS PY - 2015 DO - https://doi.org/10.1021/ja512654d SN - 0002-7863 SN - 1520-5126 VL - 137 IS - 13 SP - 4382 EP - 4390 PB - American Chemical Society CY - Washington, DC, USA AN - OPUS4-33077 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Meyer, S. A1 - Richter, S. A1 - Balski, Matthias A1 - Hagendorf, C. T1 - Trace element analysis in crystalline silicon PY - 2011 SN - 1757-1197 VL - 14th Edition IS - 4th Quarter, November SP - 34 EP - 39 PB - Semiconductor Media CY - London AN - OPUS4-25284 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traulsen, C.H.-H. A1 - Darlatt, Erik A1 - Richter, S. A1 - Poppenberg, J. A1 - Hoof, S. A1 - Unger, Wolfgang A1 - Schalley, C.A. T1 - Intermixed terpyridine-functionalized monolayers on gold: nonlinear relationship between terpyridyl density and metal ion coordination properties N2 - Aiming at the functionalization of surfaces with terpyridine anchors for the coordinative deposition of additional layers, mixed self-assembled monolayers (SAMs) were prepared from binary solutions of 12-(2,2':6',2''-terpyridine-4'-yl)dodecane-1-thiol (TDT) and 1-decanethiol (DT). The SAMs and the order of the constituting molecules were analyzed by X-ray photoelectron spectroscopy (XPS), near-edge X-ray absorption fine structure spectroscopy (NEXAFS), and time-of-flight-secondary ion mass spectrometry (ToF-SIMS). The composition of the (TDT/DT)-SAMs and with it the surface density of terpyridyl groups correlates linearly with the relative concentrations of the two compounds in the solution used for depositing them. In marked contrast, the amount of terpyridine-coordinated PdII ions significantly deviates from this trend with an optimum at a 1:3 ratio of TDT/DT. This indicates a major fraction of the terpyridines in TDT-rich SAMs not to be accessible for PdII ion coordination. In agreement, NEXAFS spectroscopy reveals the alkyl backbones in TDT-rich SAMs not to be ordered, while they are preferentially upright oriented in the optimal 1:3-(TDT/DT)-SAMs. We interpret this in terms of terpyridine backfolding in TDT-rich SAMs, while they are located in accessible positions on top of the SAM in the 1:3-(TDT/DT)-SAM. While the alkyl backbones in the 1:3-(TDT/DT)-SAM are ordered, NEXAFS spectroscopy shows the terpyridyl groups not to have a preferential orientation in this SAM and thus retain enough flexibility to adjust to molecules that are deposited on top of the mixed SAM. In conclusion, the novel SAM does not undergo phase separation and consists predominantly of intermixed phases with adjustable surface density of quite flexible terpyridine anchor groups. The terpyridine–PdII anchors are not only available for a future deposition of the next layer, but the metal ions also represent a sensitive probe for the accessibility of the terpyridyl groups. PY - 2012 DO - https://doi.org/10.1021/la301644r SN - 0743-7463 SN - 1520-5827 VL - 28 IS - 29 SP - 10755 EP - 70763 PB - American Chemical Society CY - Washington, DC AN - OPUS4-26430 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Traulsen, C. H.-H. A1 - Kunz, V. A1 - Heinrich, Thomas A1 - Richter, S. A1 - Holzweber, Markus A1 - Schulz, A. A1 - von Krbek, L. K. S. A1 - Scheuschner, U. T. J. A1 - Poppenberg, J. A1 - Unger, Wolfgang A1 - Schalley, C. A. T1 - Synthesis and coordinative layer-by-layer deposition of pyridine-functionalized gold nanoparticles and tetralactam macrocycles on silicon substrates N2 - Coordination chemistry was applied to deposit pyridine-functionalized gold nanoparticles on silicon substrates. The particles were synthesized through the Brust/Schiffrin route with a subsequent ligand exchange reaction yielding well-defined particles of two different sizes. Multilayer deposition was carried out on a pyridine-terminated SAM, anchored on a hydroxyl-terminated silicon surface. Analogously, Hunter/Vögtle-type tetralactam macrocycle multilayers were deposited as well as mixed layers containing both either in an alternating sequence or as a macrocycle multilayer with a terminating nanoparticle layer. These composite layers were examined with respect to their ability to bind squaraine axles in the macrocycle cavities. The amount of guest bound is higher for the composite layer with alternating macrocycles and nanoparticles. KW - Layer-by-layer deposition KW - Functionalized Au nanoparticles KW - SEM KW - TEM KW - DLS KW - XPS KW - NEXAFS KW - ToF-SIMS KW - IR KW - UV-vis PY - 2013 DO - https://doi.org/10.1021/la403222x SN - 0743-7463 SN - 1520-5827 VL - 29 IS - 46 SP - 14284 EP - 14292 PB - American Chemical Society CY - Washington, DC AN - OPUS4-29699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Huang, M.D. A1 - Becker-Ross, H. A1 - Okruss, M. A1 - Geisler, S. A1 - Florek, S. A1 - Richter, Silke A1 - Meckelburg, Angela T1 - Direct determination of fluorine in niobium oxide using slurry sampling electrothermal high-resolution continuum source molecular absorption spectrometry N2 - Aiming for a round-robin test, a new method for the direct determination of fluorine in niobium oxide has been developed. It is based on the use of high-resolution molecular absorption spectra of calcium mono-fluoride (CaF) generated in the graphite tube, combined with the slurry sampling technique. The absorption measurement was performed at the 606.44 nm CaF rotational line. By using graphite tubes with zirconium carbide (ZrC) modified platform, the molecular absorption sensitivity of CaF has been improved by a factor of 20, and no additional chemical modifier was necessary. Generally, non-spectral interferences were observed in the presence of HCl, H2SO4, and H3PO4. For HCl, additional spectral interference occurred due to an overlap of the absorption spectra of CaF and CaCl. However, due to the absence of these mentioned substances in the current material, such interferences do not exist for this application. The characteristic mass found for the CaF 606.44 nm line was 0.1 ng; the limit of detection was 5 mg fluorine per kg solid sample (3σ criterion). The results obtained by the method were within the range of certified values. Comparing to the classical method such as the pyrohydrolysis-photometric method, the developed new method showed clear advantages regarding sensitivity and specificity. The time requirement for one sample analysis was strongly shortened from several hours to only some minutes. KW - Continuum source molecular absorption spectrometry KW - Fluorine determination KW - Niobium oxide KW - Slurry sampling PY - 2014 DO - https://doi.org/10.1016/j.sab.2014.02.005 SN - 0584-8547 SN - 0038-6987 VL - 94-95 SP - 34 EP - 38 PB - Elsevier CY - Amsterdam AN - OPUS4-30655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tannenberg, Robert A1 - Paul, Martin A1 - Röder, Bettina A1 - Gande, S. L. A1 - Sreeramulu, S. A1 - Saxena, K. A1 - Richter, C. A1 - Schwalbe, H. A1 - Swart, C. A1 - Weller, Michael G. T1 - Chemiluminescence biosensor for the determination of cardiac troponin I (cTnI) N2 - Cardiac troponin I (cTnI) is a crucial biomarker for diagnosing cardiac vascular diseases, including acute myocardial infarction (AMI). This study presents a proof-of-concept chemiluminescence-based immunosensor for rapid and accurate measurement of cTnI, with the potential for online monitoring. The immunosensor incorporates a flow cell design and a sensitive complementary metal-oxide-semiconductor (CMOS) camera for optical readout. A microfluidic setup was established to enable selective and quasi-online determination of cTnI within ten minutes. The sensor was tested with recombinant cTnI in phosphate buffer, demonstrating measurements in the concentration range of 2–25 µg/L, with a limit of detection (LoD) of 0.6 µg/L (23 pmol/L) achieved using the optimized system. The immunosensor exhibited high selectivity, as no cross-reactivity was observed with other recombinant proteins such as cTnT and cTnC at a concentration of 16 µg/L. Measurements with diluted blood plasma and serum yielded an LoD of 60 µg/L (2.4 nmol/L) and 70 µg/L (2.9 nmol/L), respectively. This biosensor offers a promising approach for the rapid and sensitive detection of cTnI, contributing to the diagnosis and management of acute myocardial infarction and other cardiac vascular diseases. N2 - Das kardiale Troponin I (cTnI) ist ein wichtiger Biomarker für die Diagnose von Herz-Kreislauf-Erkrankungen, einschließlich des akuten Myokardinfarkts (AMI). In dieser Studie wird ein auf Chemilumineszenz basierender Immunsensor für die schnelle und genaue Messung von cTnI vorgestellt, der das Potenzial für eine Online-Überwachung hat. Der Immunsensor besteht aus einer Durchflusszelle und einer empfindlichen CMOS-Kamera (Complementary Metal-Oxide-Semiconductor) zur optischen Detektion. Es wurde ein mikrofluidischer Aufbau entwickelt, der eine selektive und quasi Online-Bestimmung von cTnI innerhalb von zehn Minuten ermöglicht. Der Sensor wurde mit rekombinantem cTnI in Phosphatpuffer getestet und zeigte einen Messbereich von 2-25 µg/L, wobei mit dem optimierten System eine Nachweisgrenze (LoD) von 0,6 µg/L (23 pmol/L) erreicht wurde. Der Immunsensor zeigte eine hohe Selektivität, da keine Kreuzreaktivität mit anderen rekombinanten Proteinen wie cTnT und cTnC bei einer Konzentration von 16 µg/L beobachtet wurde. Messungen mit verdünntem Blutplasma und Serum ergaben einen LoD von 60 µg/L (2,4 nmol/L) bzw. 70 µg/L (2,9 nmol/L). Dieser Biosensor bietet einen vielversprechenden Ansatz für den schnellen und empfindlichen Nachweis von cTnI, der zur Diagnose und Behandlung des akuten Myokardinfarkts und anderer kardialer Gefäßerkrankungen beitragen kann. KW - Acute myocardial infarction KW - Heart attack KW - Emergency KW - Diagnosis KW - Cardiac troponin KW - Biomarker KW - Immunosensor KW - Biosensor KW - Chemiluminescence KW - Luminol KW - Peroxidase KW - Monoclonal antibodies KW - Flow injection immunoassay KW - Immunometric assay KW - Immunometric biosensor KW - Microfluidic system KW - Monolithic column KW - Online biosensor PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-575471 DO - https://doi.org/10.3390/bios13040455 SN - 2079-6374 VL - 13 IS - 4 SP - 1 EP - 20 PB - MDPI CY - Basel AN - OPUS4-57547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Elordui-Zapatarietxe, S. A1 - Fettig, Ina A1 - Richter, Janine A1 - Philipp, Rosemarie A1 - Vanermen, G. A1 - Monteyne, E. A1 - Boom, G. A1 - Emteborg, H. T1 - Preparation and evaluation of sufficiently homogeneous and stable reference materials for priority hazardous substances in whole water N2 - We have prepared and evaluated three whole water test materials containing eight polycyclic aromatic hydrocarbons (PAHs), six polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) with respect to homogeneity and short-term stability. The test materials were used as samples in two inter-laboratory comparisons. The materials were composed of natural mineral water and model suspended particulate matter (SPM) containing the target compounds at ng L-1 levels. The expanded uncertainty of the estimated mass concentrations in the final test materials was obtained by combining contributions from the homogeneity, the stability and the model SPM characterization. The whole water materials were sufficiently homogeneous and stable at 4 °C for their intended use. In total, 12 out of 15 investigated target parameters could be assessed to be present with a relative combined expanded uncertainty below 25 %. The outcome of the two interlaboratory comparisons confirmed the good quality of the test materials and the level of uncertainties associated with the estimated mass concentrations. These findings are an important contribution towards the development of whole water matrix reference materials certified for PAH, PBDE and TBT in support of the Water Framework Directive of the European Union. KW - Reference material KW - Referenzmaterial KW - Water Framework Directive KW - Wasserrahmenrichtlinie KW - Whole water sample KW - Gesamtwasserprobe PY - 2016 DO - https://doi.org/10.1007/s00769-015-1189-1 SN - 0949-1775 SN - 1432-0517 VL - 21 IS - 2 SP - 113 EP - 120 PB - Springer AN - OPUS4-35728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Janine A1 - Elordui-Zapatarietxe, S. A1 - Emteborg, H. A1 - Fettig, Ina A1 - Cabillic, J. A1 - Alasonati, E. A1 - Gantois, F. A1 - Swart, C. A1 - Gokcen, T. A1 - Tunc, M. A1 - Binici, B. A1 - Rodriguez-Cea, A. A1 - Zuliani, T. A1 - Gonzalez Gago, A. A1 - Pröfrock, D. A1 - Nousiainen, M. A1 - Sawal, G. A1 - Buzoianu, M. A1 - Philipp, Rosemarie T1 - An interlaboratory comparison on whole water samples N2 - The European Water Framework Directive 2000/60/EC requires monitoring of organic priority pollutants in so-called whole water samples, i.e. in aqueous nonfiltered samples that contain natural colloidal and suspended particulate matter. Colloids and suspended particles in the liquid phase constitute a challenge for sample homogeneity and stability. Within the joint research project ENV08 ‘‘Traceable measurements for monitoring critical pollutants under the European Water Framework Directive 2000/60/EC’’, whole water test materials were developed by spiking defined amounts of aqueous slurries of ultrafinely milled contaminated soil or sediment and aqueous solutions of humic acid into a natural mineral water matrix. This paper presents the results of an European-wide interlaboratory comparison (ILC) using this type of test materials. Target analytes were tributyltin, polybrominated diphenyl ethers and polycyclic aromatic hydrocarbons in the ng/L concentration range. Results of the ILC indicate that the produced materials are sufficiently homogeneous and stable to serve as samples for, e.g. proficiency testing or method validation. To our knowledge, this is the first time that ready-to-use water materials with a defined amount of suspended particulate and colloidal matter have been applied as test samples in an interlaboratory exercise. These samples meet the requirements of the European Water Framework Directive. Previous proficiency testing schemes mainly employed filtered water samples fortified with a spike of the target analyte in a water-miscible organic solvent. KW - Water Framework Directive KW - Wasserrahmenrichtlinie KW - Interlaboratory comparison KW - Ringversuch KW - Whole water sample KW - Gesamtwasserprobe PY - 2016 DO - https://doi.org/10.1007/s00769-015-1190-8 SN - 0949-1775 SN - 1432-0517 VL - 21 IS - 2 SP - 121 EP - 129 PB - Springer AN - OPUS4-35730 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -