TY - CONF A1 - Reinholz, Uwe T1 - Evaluation of Total Reflection X-ray Fluorescence (TXRF) Analysis Using a Color X-ray Camera (CXC) T2 - Fifth Join BER II and Bessy II Users Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29834 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Gebhard, R. T1 - Synchrotron radiation–induced X-ray fluorescence (SRXRF) analyses of the Bernstorf Gold N2 - The gold finds from Bernstorf, in the Freising district of Bavaria, were discovered in 1998, in the area of a Bronze Age settlement. First analyses with X-ray fluorescence (XRF) revealed gold of an unusually high purity grade, which was explained by the use of cementation techniques. A newer analysis with laser ablation inductively coupled plasma mass spectrometry (LA–ICP–MS) indicated an even higher purity. The analytical results were the starting point of an ongoing discussion. In this study, we re-analysed 11 gold samples with Synchrotron radiation–induced X-ray fluorescence at the BAMline at BESSY. In a thorough analysis, different excitation and detection conditions were applied to confirm or disprove the previous results. It was shown that the purity of the gold from the specimen is higher than 99.9%. The main impurities are silver in a range between 20 and 200 μg/g and copper between 1 and 10 μg/g. The results are in very good agreement with the LA–ICP–MS measurements and provide basic information for discussions about provenance, processing techniques or considerations of authenticity. KW - Gold KW - Synchrotron KW - XRF KW - BESSY KW - Archeometry PY - 2017 DO - https://doi.org/10.1111/arcm.12294 SN - 0003-813X SN - 1475-4754 VL - 59 IS - 5 SP - 891 EP - 899 PB - Wiley AN - OPUS4-42540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich T1 - Synchrotron radiation induced X-ray fluorescence for the characterization of ancient gold objects KW - Gold KW - Hiddensee treasure KW - Nebra sky disc KW - Non-destructive testing KW - Silver point drawings KW - Synchrotron KW - X-ray fluorescence KW - Or KW - Trésor d´Hiddensee KW - Disque déleste de Nebra KW - Analyse non-destructive KW - Dessins à pointe d´argent KW - Synchrotron KW - Fluorescence à rayons X PY - 2009 SN - 0399-1237 VL - 33 SP - 39 EP - 44 PB - Groupe CY - Rennes AN - OPUS4-23219 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reinholz, Uwe T1 - The SLcam: A full-field energy dispersive X-ray camera T2 - 14th International Workshop on Radiation Imaging Detectors CY - Figueira da Foz, Portugal DA - 2012-07-01 PY - 2012 AN - OPUS4-26130 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reinholz, Uwe T1 - Shading in TXRF: Calculations and experimental validation using a color X-Ray camera with subpixel resolution T2 - Denver X-Ray Conference CY - Westminster, Colorado, USA DA - 2015-08-03 PY - 2015 AN - OPUS4-33959 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reinholz, Uwe T1 - Studies on Ancient Silver Metallurgy Using Micro-SR-XRF and Micro-PIXE T2 - Synchrotron Radiation in Art and Archaeology SR2A CY - Paris DA - 2014-09-10 PY - 2014 AN - OPUS4-32399 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Curado, Jessica A1 - Radtke, Martin A1 - Buzanich, Günter A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Guttler, R.A.S. A1 - Rizzutto, M.A. T1 - μ-SRXRF characterization of Brazilian emeralds N2 - The aim of the present study is to characterize emeralds from different mines of Brazil by using Synchrotron Radiation X-ray Fluorescence Microanalysis (µ-SRXRF). The advantage of this technique is that we can analyze a homogeneous, inclusion free area of the stone with the microbeam to distinguish the elemental fingerprint according to the provenance of the emerald. A total of 47 samples belonging to 5 different Brazilian mines were studied in this work and 28 elements were identified. By means of Principal Component Analysis (PCA) it is possible to build different groups according to the provenance of the stones, which allows to assign samples of unknown origin to the according mine. T2 - 22nd International congress on X-ray optics and microanalysis CY - Hamburg, Germany DA - 02.09.2013 KW - µ-SRXRF KW - BAMline KW - Emeralds KW - Geoscience PY - 2014 DO - https://doi.org/10.1088/1742-6596/499/1/012016 SN - 1742-6588 SN - 1742-6596 VL - 499 SP - 012016-1 EP - 012016-5 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-30541 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ordavo, I. A1 - Ihle, S. A1 - Arkadiev, V. A1 - Scharf, Oliver A1 - Soltau, H. A1 - Bjeoumikhov, A. A1 - Bjeoumikhova, S. A1 - Buzanich, Günter A1 - Gubzhokov, R. A1 - Günther, A. A1 - Hartmann, R. A1 - Holl, P. A1 - Kimmel, N. A1 - Kühbacher, M. A1 - Lang, M. A1 - Langhoff, N. A1 - Liebel, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Schaller, G. A1 - Schopper, F. A1 - Strüder, L. A1 - Thamm, C. A1 - Wedell, R. T1 - A new pnCCD-based color X-ray camera for fast spatial and energy-resolved measurements N2 - We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested. KW - X-ray CCD camera KW - pnCCD KW - Fast X-ray imaging KW - XRF KW - Full-field X-ray fluorescence KW - Elemental analysis KW - High quantum efficiency KW - High energy resolution KW - Polycapillary optics PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.05.080 SN - 0168-9002 SN - 0167-5087 VL - 654 SP - 250 EP - 257 PB - North-Holland CY - Amsterdam AN - OPUS4-24370 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strub, Erik A1 - Plarre, Rüdiger A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Schoknecht, Ute A1 - Urban, Klaus A1 - Jüngel, P. T1 - Determination of Cr(VI) in wood specimen: A XANES study at the Cr K edge N2 - The content of chromium in different oxidation states in chromium-treated wood was studied with XANES (X-ray absorption near-edge structure) measurements at the Cr K absorption edge. It could be shown that wood samples treated with Cr(VI) (pine and beech) did still contain a measurable content of Cr(VI) after four weeks conditioning. If such wood samples were heat exposed for 2 h with 135 °C prior conditioning, Cr(VI) was no longer detected by XANES, indicating a complete reduction to chromium (III). KW - X-ray spectroscopy KW - XANES KW - XAS KW - XRF KW - Specifikation KW - Reduction PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.011 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2405 EP - 2407 PB - Elsevier CY - Amsterdam AN - OPUS4-17555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reinholz, Uwe T1 - Double Dispersive X-Ray Fluorescence T2 - European Conference on X-Ray Spectrometry EXRS CY - Bologna (Italien) DA - 2014-06-15 PY - 2014 AN - OPUS4-32396 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Merchel, Silke A1 - Berger, Achim A1 - Görner, Wolf A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vogl, Jochen A1 - Frisch, A. A1 - Reiche, I. T1 - Kunst- und Kulturgüter unter "Beschuss" T2 - GDCh-Jahrestagung Chemie 2003 ; Jahrestagung der Fachgruppe Nuklearchemie ; 19. Seminar Aktivierungsanalyse CY - München, Deutschland DA - 2003-10-06 PY - 2003 SN - 3-936028-14-1 N1 - Serientitel: Kurzreferate / GDCh-Jahrestagung Chemie 2003 – Series title: Kurzreferate / GDCh-Jahrestagung Chemie 2003 IS - 5 SP - 68 PB - Gesellschaft Deutscher Chemiker CY - Frankfurt am Main AN - OPUS4-2686 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Frisch, A. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Vogl, Jochen ED - Röhrs, S. T1 - Synchrotron-XRF und PIXE Untersuchungen an bronzezeitlichen Fussringen T2 - Jahrestagung 2003 im Ethnologischen Museum Berlin-Dahlem CY - Berlin, Deutschland DA - 2003-03-12 PY - 2003 SN - 3-00-014223-1 SN - 0949-4057 SP - 101 EP - 103 CY - [Frankfurt am Main] AN - OPUS4-2355 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -