TY - CONF A1 - Radtke, Martin T1 - Slicing - A New Method For Non Destructive 3D Elemental Sensitive Characterization Of Materials T2 - Fifth Joint BER II and BESSY II User Meeting CY - Berlin, Germany DA - 2013-12-04 PY - 2013 AN - OPUS4-29904 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radtke, Martin A1 - Buzanich, Günter A1 - de Oliveira Guilherme Buzanich, Ana A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Scharf, O. A1 - Scholz, Philipp A1 - Guerra, M.F. T1 - Double Dispersive X-Ray Fluorescence (D2XRF) based on an Energy Dispersive pnCCD detector for the detection of platinum in gold N2 - With the aim of improving limits of detection (LOD) of trace elements in a matrix with adjacent fluorescence energies, a simple double dispersive X-ray fluorescence detection system (D2XRF) was constructed to operate at the beamlines BAMline and the mySpot @ BESSY II. This system is based on the combination of a crystal analyzer with an energy resolving single photon counting pnCCD. Without further collimators, the efficient suppression of the background by the pnCCD and the good energy resolution of the crystal results in improved LOD. In first order reflections, an energy resolution of 13 eV for Cu Kα was reached, and an energy range of 1 keV was covered in one shot. This new system was applied to the detection of platinum (Pt) in gold leaves with a LOD of 0.9 mg/kg, which is the lowest attained by totally non-destructive methods nowadays. The presence of Pt in gilded objects from Abydos and Byzantine mosaics provides vital information, as it indicates the alluvial origin of the gold for these examples. KW - Platinum Wavelength dispersive D2XRF KW - Gold Synchrotron XRF PY - 2016 DO - https://doi.org/10.1016/j.microc.2015.10.039 VL - 125 SP - 56 EP - 61 PB - Elsevier Science CY - Amsterdam AN - OPUS4-35777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - The Colour X-Ray Camera: Basics, Applications and Perspectives T2 - Third Joint BER II and Bessy II User`s Meeting CY - Berlin, Germany DA - 2011-11-30 PY - 2011 AN - OPUS4-25269 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lutz, C. A1 - Hampel, S. A1 - Ke, X. A1 - Beuermann, S. A1 - Turek, T. A1 - Kunz, U. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin A1 - Fittschen, U. T1 - Evidence for redox reactions during vanadium crossover inside the nanoscopic water-body of Nafion 117 using X-ray absorption near edge structure spectroscopy N2 - A major source of capacity fade of the common vanadium redox flow battery (VRFB) is the vanadium ion transport through the separator. However, different transport models disagree significantly in the diffusion coefficient for the different V species and the influence of different transport mechanisms. The underlying hypothesis of this work is that reactions inside the membrane are partly responsible for these discrepancies. Accordingly, it was investigated if redox reactions inside the nanoscopic water body of Nafion 117 can occur. X-ray absorption near edge structure spectroscopy (XANES) was used to distinguish between the different V species inside hydrated Nafion 117 and novel PVDF-based membranes. It was validated that the speciation of vanadium can be performed using the pre-edge peak energy and intensity. The experiments were performed as follows: strips of the membrane were exposed from one site to a V3+ solution (green) and from the other site to a VO2+ solution (yellow). The ions could diffuse into the membrane from both sides. A change of color of the membrane strip was observed. The blue color in the middle of the strip indicated that VO2+ was formed where V3+ and VO2+ got in contact. Using XANES this reaction inside Nafion was proven. KW - PVDF-Based membrane KW - VRFB KW - Vanadium speciation KW - XANES KW - Nafion 117 PY - 2020 DO - https://doi.org/10.1016/j.jpowsour.2020.229176 VL - 483 SP - 229176 PB - Elsevier B.V. AN - OPUS4-51719 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Cakir, Cafer Tufan A1 - de Oliveira Guilherme Buzanich, Ana A1 - Radtke, Martin T1 - A Digital Twin Workflow for Optimizing X-ray Emission Spectroscopy (XES) Parameters in Material Science N2 - In this contribution, I present a digital twin-based workflow designed to optimize experimental parameters in X-ray emission spectroscopy (XES), with a focus on reproducibility, data integration, and alignment with FAIR (Findable, Accessible, Interoperable, Reusable) principles in materials science and engineering (MSE). The developed pipeline begins with automated retrieval of crystallographic information from the Materials Project database based on a given sample composition. This structural data is then used to simulate the corresponding XES spectra using FDMNES, allowing for accurate prediction of element-specific emission lines. The simulated emission lines are fed into an X-ray tracing (XRT) module, which builds a virtual replica of the experimental setup. This digital twin environment enables predictive modeling of spectrometer performance based on geometric configurations. The optimization focuses on two key parameters: the choice of the analyzing crystal and the distance between the sample and crystal (which also defines the crystal–detector distance due to Bragg condition constraints). An active learning algorithm is employed to iteratively adjust these parameters in order to achieve a desired energy-per-pixel (E/pixel) resolution with minimal intensity loss, enabling efficient, data-driven experimental planning. By integrating data-driven simulations with real-time optimization strategies, this workflow supports efficient experiment planning while minimizing resource consumption and human error. Furthermore, all stages of the process—from data collection and simulation to optimization and visualization—are structured to ensure traceability and interoperability, facilitating future reuse and collaborative research. I hope this contribution aligns well with the topic “Workflows for FAIR MSE Data” and offers a concrete example of how digital twins can be harnessed to improve the design, execution, and documentation of spectroscopy experiments in the MSE domain. T2 - Opportunities and Challenges of FAIR Data at Photon and Neutron Facilities CY - Bad Honnef, Germany DA - 12.10.2025 KW - Digital-Twin KW - XES KW - Optimization KW - Machine Learning PY - 2025 AN - OPUS4-64676 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grengg, C. A1 - Koraimann, G. A1 - Ukrainczyk, N. A1 - Rudic, O. A1 - Luschnig, S. A1 - Gluth, Gregor A1 - Radtke, Martin A1 - Dietzel, M. A1 - Mittermayr, F. T1 - Cu- and Zn-doped alkali activated mortar – Properties and durability in (bio)chemically aggressive wastewater environments N2 - Metakaolin-based alkali activated mortars (AAM) - with and without CuSO4·5H2O and ZnO addition (mass ratio Mn+/solid binder 0.08% to 1.7%) - were casted and exposed within an extensive long-term field campaign over the period of 20 months to a sewer basin, strongly affected by biogenic acid corrosion. (Un-)exposed AAM were tested regarding their physicochemical and microstructural properties, bioreceptivity and overall durability. Metal addition led to a retarding effect during alkali-activation reaction, as well as to an increase in open porosity of up to 3.0% and corresponding lower compressive strength of up to 10.9%. Reduced microbial colonization and diversity were observed on AAM with Cu, while Zn addition led to increased biodiversity. We propose that the observed higher durability of Cu-doped AAM is due to antibacterial effects and associated reduction of biogenic acid production, superseding overall negative effects of metal-dosage on physical material properties. Observed lower durability of Zn-doped AAM was related to combined negative physicochemical and microbial effects. KW - Microbially induced corrosion KW - Alkali-activated materials KW - Biogenic acid corrosion KW - Biogene Schwefelsäurekorrosion KW - MIC PY - 2021 DO - https://doi.org/10.1016/j.cemconres.2021.106541 SN - 0008-8846 VL - 149 SP - 1 EP - 15 PB - Elsevier CY - Oxford AN - OPUS4-53070 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nowak, S.H. A1 - Bjeoumikhov, A. A1 - Von Borany, J. A1 - Buchriegler, J. A1 - Munnik, F. A1 - Petric, M. A1 - Renno, A.D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Scharf, O. A1 - Strüder, L. A1 - Wedell, R. A1 - Ziegenrücker, R. T1 - Examples of XRF and PIXE imaging with few microns resolution using SLcam® a color X-ray camera N2 - We present results of recent development of the color X-ray camera, type SLcam®, allowing detection of X-ray images with few microns resolution. Such spectral resolution is achieved with the use of high-quality polycapillary optics combined with sub-pixel resolution. Imaging of Siemens star resolution test chart reveals that the resolution limit of SLcam® can go down to nearly 5µm. Several real sample examples of measurements carried out at the laboratory, synchrotron, and particle-induced X-ray emission beamlines are shown. This is the first time SLcam® is used as particle-induced X-ray emission detector. KW - X-ray KW - Color X-ray camera KW - CXC KW - Synchrotron radiation KW - BESSY KW - BAMline PY - 2015 DO - https://doi.org/10.1002/xrs.2590 SN - 0049-8246 VL - 44 IS - 3 SP - 135 EP - 140 PB - Wiley & Sons, Ltd. CY - Chichester AN - OPUS4-33170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Reiche, I. A1 - Berger, Achim A1 - Görner, Wolf A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich T1 - Dürer's chemischer Fingerprint - Untersuchungen mittels Synchrotron-induzierter Röntgenfluoreszenzanalyse T2 - 5. Erfurter Fachtage für Konservierung und Restaurierung CY - Erfurt, Germany DA - 2002-11-28 PY - 2002 AN - OPUS4-2123 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eichelbaum, M. A1 - Rademann, K. A1 - Müller, Ralf A1 - Radtke, Martin A1 - Görner, Wolf T1 - Zur Chemie des Goldes in Silicatgläsern: Untersuchungen zum nicht-thermisch aktivierten Wachstum von Goldclustern KW - Glas KW - Goldcluster KW - Nanophotonik PY - 2005 DO - https://doi.org/10.1002/ange.200502174 SN - 0044-8249 SN - 0932-2140 SN - 1521-3757 VL - 117 IS - 48 SP - 8118 EP - 8122 PB - Wiley-VCH CY - Weinheim AN - OPUS4-7691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaiser, J. A1 - Szczerba, Wojciech A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Albrecht, M. A1 - Lu, Y. A1 - Ballauff, M. T1 - The structure of AuPd nanoalloys anchored on spherical polyelectrolyte brushes determined by x-ray absorption spectroscopy N2 - Well-defined and facetted bimetallic gold–palladium nanoalloys have been synthesized and anchored in spherical polyelectrolyte brushes (SPB) as composite particles (AuPd@SPB). These particles are better catalysts in aqueous phase than the pure metals. The atomistic arrangement of these nanoalloys has been analysed by extended X-ray absorption fine structure (EXAFS) spectroscopy at the Au–L3 and the Pd–K absorption edge. The samples with high amounts of gold appear as almost statistically mixed random alloys. Alloy compositions with less gold show slight enrichment of Pd at the surface of the particle. In addition, signals of non-metallic palladium appear at the Pd–K edge which indicate the presence of the Pd2+ species in addition to metallic palladium. The relation of these structural features to the catalytic activity is discussed. KW - EXAFS KW - Nanoalloys KW - Gold KW - Palladium KW - K-edge KW - L3-edge KW - HR-TEM KW - Synchrotron radiation KW - BAMline PY - 2013 DO - https://doi.org/10.1039/c3fd20132e SN - 1359-6640 SN - 1364-5498 VL - 162 SP - 45 EP - 55 PB - Soc. CY - Cambridge [u.a.] AN - OPUS4-28300 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Radtke, Martin T1 - X-Ray fluorescence with synchrotron radiation basics and applications N2 - In this talk, the features of X-ray fluorescence analysis with synchrotron radiation will be presented. First, the basics of the origin of synchrotron radiation and X-ray fluorescence analysis and the experimental setup will be discussed. Then, examples of trace element detection, micrometer resolution, and application of the X-ray color camera will be shown. T2 - HZB Photon school 2020 CY - Berlin, Germany DA - 09.03.2020 KW - Synchrotron KW - BAMline KW - XRF KW - Machine learning PY - 2020 AN - OPUS4-51894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Radtke, Martin A1 - Berger, Achim A1 - Görner, Wolf A1 - Ketelsen, T. A1 - Merchel, Silke A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved synchrotron-induced X-ray fluorescence analyses of metal point drawings and their mysterious inscriptions N2 - Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (1471–1528) and Jan van Eyck (approximately 1395–1441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, “Willibald Pirckheimer” (1503), and a second one attributed to Jan van Eyck, showing a “Portrait of an elderly man”, often named “Niccolò Albergati”, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages. KW - Sy-XRF analysis KW - Drawing KW - Metal point KW - Albrecht Dürer KW - Jan van Eyck KW - Renaissance PY - 2004 DO - https://doi.org/10.1016/j.sab.2004.07.023 SN - 0584-8547 SN - 0038-6987 VL - 59 IS - 10-11 SP - 1657 EP - 1662 PB - Elsevier CY - Amsterdam AN - OPUS4-4575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Simons, C. A1 - Mans, C. A1 - Hanning, S. A1 - Janßen, A. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Ostermann, Markus A1 - Michaelis, Matthias A1 - Wienold, Julia A1 - Alber, D. A1 - Kreyenschmidt, M. T1 - Study on microscopic homogeneity of polymeric candidate reference materials BAM H001-BAM H010 by means of synchrotron µ-XRF and LA-ICP-MS N2 - In this study the microscopic homogeneity of the newly developed plastic reference materials BAM H001-BAM H010 was investigated. The materials consist of an acrylonitryle-butadien-styrene terpolymer, doped with different amounts of the elements Br, Cd, Cr, Hg and Pb. For the quantitative determination of the degree of homogeneity, a procedure proposed by Kempenaers et al. (Fresenius J. Anal. Chem., 2001, 369, 733-737) was used. On every sample an extensive number of different points were analyzed and standard deviation for every element mentioned above was used to calculate a minimal sampling mass that is necessary to reach a certain level of uncertainty caused by inhomogeneity (mmin,5%). The experiments were taken out with synchrotron µ-XRF (SR µ-XRF) at BESSYII in Berlin and by laser ablation inductively coupled plasma mass spectroscopy (LA-ICP-MS). The calculated values for mmin,5% of both techniques showed comparable results for all elements. It could be shown that the materials are suitable for calibration of micro analytic techniques if at least 64 µg are used. KW - XRF KW - LA-ICP-MS KW - RoHS KW - CRM PY - 2010 DO - https://doi.org/10.1039/b917008a SN - 0267-9477 SN - 1364-5544 VL - 25 SP - 40 EP - 43 PB - Royal Society of Chemistry CY - London AN - OPUS4-20938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Kühbacher, M. A1 - Weseloh, G. A1 - Bertelsmann, H. A1 - Özaslan, M. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Kyriakopoulos, A. A1 - Behne, D. T1 - Analysis of metal- and metalloid-containing proteins by SRXRF at the BAMline N2 - Pilot studies have been carried out at the BAMline at BESSY II in collaboration with the Bundesanstalt für Materialforschung und -prüfung (BAM) on metal- and metalloid-containing compounds in biological samples after electrophoretic protein separation. After sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) and transfer onto a blotting membrane the distribution of selenium among the proteins of testis homogenate of a rat and a wallaby was determined. The comparison with the autoradiogram of 75Se-labeled proteins separated in the same way showed that of nine seleniumcontaining proteins found in rat testis homogenate by autoradiography four could be detected by synchrotron radiation X-ray fluorescence analysis (SRXRF). PY - 2003 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2002.pdf#page=333 SN - 0179-4159 SP - 333 EP - 335 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-2495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Schäfer, D. A1 - Simon, R. T1 - SY-XRF study of Hans Baldung Grien silverpoint drawings and the silver stylus from the 'Karlsruhe sketchbook' N2 - We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period. KW - Synchrotron KW - XRF analysis KW - Drawings KW - Silver stylus PY - 2007 DO - https://doi.org/10.1002/xrs.963 SN - 0049-8246 VL - 36 IS - 3 SP - 173 EP - 177 PB - Wiley CY - Chichester AN - OPUS4-16150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vasilescu, A. A1 - Constantinescu, B. A1 - Stan, D. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Ceccato, D. T1 - Studies on ancient silver metallurgy using SR XRF and micro-PIXE N2 - This work presents a complex evaluation of a series of Geto-Thracian silver adornments found on Romanian territory, part of the 4th century BC Agighiol (Northern Dobruja) hoard and of an ingot from the 1st century BC Geto-Dacian Surcea (Transylvania) hoard, using Synchrotron Radiation X-Ray Fluorescence and micro- Proton Induced X-ray Emission analysis and mapping in order to investigate aspects related to the elemental composition of the metal and the metallurgy implied in their manufacture. One of the samples can be linked to Laurion as the source of metal, and several items contain silver probably originated in Macedonia. The set of silver items was found to be heteregenous as composition and microstructure, and corrosion-related elements could be also identified in the X-Ray maps. KW - Synchrotron radiation XRF KW - Micro-PIXE KW - Archaeological silver PY - 2015 DO - https://doi.org/10.1016/j.radphyschem.2015.07.008 SN - 0969-806X SN - 0020-7055 SN - 0146-5724 VL - 117 SP - 26 EP - 34 PB - Pergamon Press CY - Oxford [u.a.] ; Frankfurt, M. AN - OPUS4-33809 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fittschen, U.E.A. A1 - Menzel, M. A1 - Scharf, O. A1 - Radtke, Martin A1 - Reinholz, Uwe A1 - Buzanich, Günter A1 - Lopez, V.M. A1 - McIntosh, K. A1 - Streli, C. A1 - Havrilla, G.J. T1 - Observation of X-ray shadings in synchrotron radiation-total reflection X-ray fluorescence using a color X-ray camera N2 - Absorption effects and the impact of specimen shape on TXRF analysis has been discussed intensively. Model calculations indicated that ring shaped specimens should give better results in terms of higher counts per mass signals than filled rectangle or circle shaped specimens. One major reason for the difference in signal is shading effects. Full field micro-XRF with a color X-ray camera (CXC) was used to investigate shading, which occurs when working with small angles of excitation as in TXRF. The device allows monitoring the illuminated parts of the sample and the shaded parts at the same time. It is expected that sample material hit first by the primary beam shade material behind it. Using the CXC shading could be directly visualized for the high concentration specimens. In order to compare the experimental results with calculation of the shading effect the generation of controlled specimens is crucial. This was achieved by 'drop on demand' technology. It allows generating uniform, microscopic deposits of elements. The experimentally measured shadings match well with those expected from calculation. KW - TXRF KW - Full field micro-XRF KW - Color X-ray camera PY - 2014 DO - https://doi.org/10.1016/j.sab.2014.06.025 SN - 0584-8547 SN - 0038-6987 VL - 99 SP - 179 EP - 184 PB - Elsevier CY - Amsterdam AN - OPUS4-31180 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strüder, L. A1 - Hartmann, R. A1 - Holl, P. A1 - Ihle, S. A1 - Huth, M. A1 - Schmidt, J. A1 - Tham, Ch. A1 - Kanngießer, B. A1 - Baumann, J. A1 - Renno, A. A1 - Grenzer, J. A1 - Radtke, Martin A1 - Abboud, A. A1 - Pietsch, U. A1 - Soltau, H. T1 - High Speed, High Resolution imaging spectrometers based on pnCCDs for XRF and XRD applications N2 - For many years pnCCDs have been well known as X-ray detectors for spectroscopic imaging in many fields of science: X-Ray Fluorescence analysis (XRF), X-ray Diffraction (XRD) with light sources in large accelerator facilities as well as with laboratory light sources or with X-rays from celestial sources in X-ray astronomy. A brief introduction in GEXRF (Grazing Emission XRF) measurements with a laboratory laser produced plasma source will be given, PIXE (Particle Induced X-ray Emission) measurements and D2XRF (Double Dispersive X-Ray Fluorescence) and Slicing experiments with pnCCDs coupled to polycapillary optics performed at the BESSY synchrotron will be shown. Energy-dispersive Laue diffraction with ultra-hard X-rays for the analysis of defects in metals will conclude the overview of spectroscopic X-ray imaging measurements in the field of structure and dynamics of matter. KW - PnCCD KW - Synchrotron KW - XRF PY - 2016 DO - https://doi.org/10.1017/S1431927616001355 VL - 22 IS - S3 SP - 100 EP - 101 AN - OPUS4-38884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zier, M. A1 - Reinholz, Uwe A1 - Riesemeier, Heinrich A1 - Radtke, Martin A1 - Munnik, F. T1 - Accurate stopping power determination of 15N ions for hydrogen depth profiling by a combination of ion beams and synchrotron radiation N2 - Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA. KW - Nuclear reaction analysis KW - Hydrogen depth profiling KW - Stopping cross section KW - Linear energy transfer KW - Synchrotron radiation KW - XRR PY - 2012 DO - https://doi.org/10.1016/j.nimb.2011.07.027 SN - 0168-583X SN - 1872-9584 VL - 273 SP - 18 EP - 21 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-25722 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Constantinescu, B. A1 - Bugoi, R. A1 - Cojocaru, V. A1 - Radtke, Martin A1 - Calligaro, T. A1 - Salomon, J. A1 - Pichon, L. A1 - Röhrs, S. A1 - Ceccato, D. A1 - Oberländer-Târnoveanu, E. T1 - Micro-SR-XRF and micro-PIXE studies for archaeological gold identification - The case of Carpathian (Transylvanian) gold and of Dacian bracelets N2 - Trace-elements are more significant for provenancing archaeological metallic artifacts than the main components. For gold, the most promising elements are platinum group elements (PGE), Sn, Te, Sb, Hg and Pb. Several small fragments of natural Transylvanian gold – placer and primary – were studied by using micro-PIXE technique at the Legnaro National Laboratory AN2000 microbeam facility, Italy and at the AGLAE accelerator, C2RMF, Paris, France and by using micro synchrotron radiation X-ray fluorescence (micro-SR-XRF) at BESSY synchrotron, Berlin, Germany. The goal of the study was to identify the trace-elements, especially Sn, Sb and Te. A spectacular application to five Dacian gold bracelets authentication is presented (Sn and Sb traces). KW - Micro-PIXE KW - Micro-SR-XRF KW - Gold KW - Dacian bracelets KW - Transylvania PY - 2008 DO - https://doi.org/10.1016/j.nimb.2008.03.054 SN - 0168-583X SN - 1872-9584 VL - 266 IS - 10 SP - 2325 EP - 2328 PB - Elsevier CY - Amsterdam AN - OPUS4-17736 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Denker, A. A1 - Hahn, Oliver A1 - Kanngießer, B. A1 - Malzer, W. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Röhrs, S. A1 - Reiche, I. A1 - Stege, H. T1 - Chemie der Kunst - Zerstörungsfreie Analyse von Kunst- und Kulturgütern N2 - Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen. PY - 2003 DO - https://doi.org/10.1515/mt-2003-0003 SN - 0025-5300 VL - 45 IS - 11-12 SP - 485 EP - 503 PB - Carl Hanser Verlag CY - München AN - OPUS4-2745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -