TY - JOUR A1 - Holzweber, Markus A1 - Lippitz, Andreas A1 - Hesse, R. A1 - Denecke, R. A1 - Werner, W. A1 - Unger, Wolfgang T1 - The use of ionic liquids for the determination of the spectrometer transmission function in X-ray photoelectron spectroscopy (XPS) JF - Journal of Electron Spectroscopy and Related Phenomena N2 - The uncertainty of measurement in quantitative XPS analysis can be reduced by using a calibrated spectrometer transmission function T (E), which is usually determined by taking spectra from Au, Ag, Cu and Ge elemental reference materials. However, this approach is quite time-consuming due to required sample preparation steps like sputter cleaning etc., and the relatively big number of samples to be measured. This contribution proposes the use of the ionic liquids [C2C1im][NTf2] and [C3C1im][NTf2] as reference materials for a determination of T(E). These multi-elemental samples deliver five intensive photoemission peaks, F 1s, O 1s, N 1s, C 1s and S 2p, in an energy window from 160 eV to 700 eV which is of specific interest for applications of quantitative XPS for surface chemical analysis of soft matter, one of the major applications of XPS. KW - Quantitative XPS KW - Ionic liquid KW - Transmission function PY - 2019 DO - https://doi.org/10.1016/j.elspec.2019.03.008 VL - 233 SP - 51 EP - 56 PB - Elsevier B.V. AN - OPUS4-48019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hesse, R. A1 - Denecke, R. A1 - Radnik, Jörg T1 - Testing and validating the improved estimation of the spectrometer-transmission function with UNIFIT 2022 JF - Surface and Interface Analysis N2 - Recent developments of X-ray photoelectron spectroscopy using excitation energies different from the usual lab-sources Mg Kα and Al Kα, thus covering larger and different kinetic energy ranges, require more flexible approaches for determining the transmission function than the well-established ones using reference spectra. Therefore, the approach using quantified peak areas (QPA) was refined allowing a more precise estimation of the transmission function. This refinement was tested by comparing the results obtained with the new version with former calculations. Furthermore, the obtained transmission function was validated by comparing the results with a transmission function using the reference spectrum of polyethylene. Additionally, an ionic liquid was used as reference for estimating the transmission function at the energy resolved HE-SGM beamline at BESSY II. Comparison between the measured and stoichiometric composition shows that a transmission function was determined, which allows a reasonable quantification. KW - XPS KW - Quantification KW - Software UNIFIT 2022 KW - Synchrotron radiation KW - Transmission function IERF PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-551671 DO - https://doi.org/10.1002/sia.7131 SN - 0142-2421 SP - 1 EP - 7 PB - Wiley-VCH AN - OPUS4-55167 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -