TY - GEN A1 - Gaal, Mate A1 - Bernhardt, Y. A1 - Csaszar, L. A1 - Dengiz, N. A1 - Fuchs, M. A1 - Gautzsch, T. A1 - Gohlke, Dirk A1 - Hahn-Jose, T. A1 - Heckel, Thomas A1 - Hillger, W. A1 - Hufschläger, Daniel A1 - Ilse, D. A1 - Kiel, M. A1 - Kornely, M. A1 - Labud, P. A. A1 - Marhenke, T. A1 - Schubert, F. A1 - Sommerhuber, R. A1 - Steinhausen, R. A1 - Szewieczek, A. A1 - Wachter, L. A1 - Waschkies, T. T1 - Guideline US 08 Characterization and verification of air-coupled ultrasonic probes N2 - This guideline was drafted following and complementing the norm ISO 22232-2:2020(E) to include air-coupled ultrasonic transducers. This document specifies the characteristics of probes used for non-destructive air-coupled ultrasonic testing with center frequencies above 20 kHz, with focusing or without focusing means. KW - Air-coupled ultrasound KW - Ultrasonic testing KW - Guideline KW - Probe KW - Characterization PY - 2022 SN - 978-3-947971-26-8 SP - 1 EP - 27 CY - Berlin AN - OPUS4-56228 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bernhardt, R. A1 - Scharnweber, D. A1 - Müller, B. A1 - Thurner, P. A1 - Schliephake, K. A1 - Wyss, P. A1 - Beckmann, F. A1 - Goebbels, Jürgen A1 - Worch, H. T1 - Comparison of microfocus- and synchrotron X-ray tomography for the analysis of osteointegration around T16AL4V-implants N2 - Micro-computed tomography (µCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, using cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 µCT-systems with X-ray tubes, one synchrotron-radiation-based µCT-system (SRµCT), and classical histology. Although the spatial resolution of the µCTsystems is comparable, only the results of SRµCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200 µm from the implant surface. Due to the non-destructive character of µCT the specimens can be subsequently examined by classical histology without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the detected amount of newly formed bone from the selected slice. This implies the necessity of 3D analysis. SRµCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRµCT, the preparation artefacts due to cutting and polishing are excluded. KW - X-ray micro computed tomography KW - Comparison of microfocus and synchrotron radiation KW - Osteointegration KW - Surface modification of titanium implants KW - Histology KW - Bone segmentation KW - Quantification of bone formation PY - 2004 UR - http://www.ecmjournal.org/journal/papers/vol007/vol007a05.php SN - 1473-2262 VL - 7 SP - 42 EP - 51 PB - Univ. of Wales CY - Aberystwyth, Wales AN - OPUS4-5600 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rammelt, S. A1 - Heck, C. A1 - Bernhardt, R. A1 - Bierbaum, S. A1 - Scharnweber, D. A1 - Goebbels, Jürgen A1 - Ziegler, J. A1 - Biewener, A. A1 - Zwipp, H. T1 - In Vivo Effects of Coating Loaded and Unloaded Ti Implants with Collagen, Chondroitin Sulfate, and Hydroxyapatite in the Sheep Tibia N2 - The in vivo effects of coating titanium implants with organic extracellular matrix molecules were examined in the sheep tibia. Titanium screws (5.0 mm) were coated with type I collagen (Ti/Coll) or type I collagen and chondroitin sulfate (Ti/Coll/CS) by biomimetic fibrillogenesis. Uncoated screws (Ti) and screws coated with hydroxyapatite (Ti/HA) served as control. Six adult female sheep received one screw of each type to stabilize a midshaft tibial fracture with external fixation. Four cylindrical implants of 4-mm outer diameter and 3.3-mm inner diameter with the same coatings were inserted into the tibial head. No pin track infections were seen at the time of implant retrieval 6 weeks after implantation. Extraction torque was greater for Ti/HA (1181 Nmm) and Ti/Coll/CS (1088 Nmm) compared to Ti/Coll (900 Nmm) and Ti (904 Nmm) [N.S.]. Newly formed bone was noted around all coated screws within the medullary cavity. Macrophage and osteoclast activity was significantly reduced around Ti/Coll/CS in both types of implants compared to uncoated controls (p < 0.05). Osteoblast activity was significantly increased around loaded Ti/Coll and Ti/Coll/CS screws compared to uncoated Ti screws (p < 0.05). Microtomographic evaluation (SRµCT) revealed no significant differences in new bone formation around the unloaded tibial head implants.Coating of external fixation devices with of type I collagen and chondroitin sulfate appears to have similar effects with respect to stability and bone healing as HA but with less osteoclast activity. These findings were more pronounced under loaded than unloaded conditions in the sheeptibia. KW - titanium KW - Bone implants KW - Coating KW - Chondroitin sulfate KW - Collagen KW - External fixation PY - 2007 DO - https://doi.org/10.1002/jor.20403 SN - 0736-0266 SN - 1554-527X VL - 25 IS - 8 SP - 1052 EP - 1061 PB - Wiley CY - Hoboken, NJ AN - OPUS4-15817 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Bernhardt, Y. A1 - Csaszar, L. A1 - Dengiz, N. A1 - Fuchs, M. A1 - Gautzsch, T. A1 - Gohlke, Dirk A1 - Hahn-Jose, T. A1 - Heckel, Thomas A1 - Hillger, W. A1 - Hufschläger, Daniel A1 - Ilse, D. A1 - Kiel, M. A1 - Labud, P. A1 - Schubert, F. A1 - Sommerhuber, R. A1 - Szewieczek, A. A1 - Waschkies, T. T1 - Richtlinie zur Charakterisierung von luftgekoppelten Ultraschallwandlern N2 - Zur Charakterisierung von luftgekoppelten Ultraschallwandlern werden mehrere verschiedene Methoden und Verfahren angewendet. Durch die unterschiedlichen Herangehensweisen werden oft unterschiedliche Prüfkopfpara-meter und Schallfeldgrößen ermittelt, was einen direkten Vergleich von Datenblättern erschwert. Für die Charakterisierung von Kontakt- und Tauchtechnikprüfköpfen hat sich ISO 22232-2:2021 bereits etabliert, allerdings ist diese Norm nicht auf die luftgekoppelten Wandlertechnologien direkt übertragbar. Daher erkannten Hersteller, Forschungseinrichtungen und Anwender den Bedarf an einer Richtlinie zur einheitlichen Charakterisierung von luftgekoppelten Wandlern. Gemeinsam arbeiten sie aktuell im Rahmen des Unterausschusses „Luftgekoppelte Ultraschallprüfung“ der DGZfP an der Erstellung einer solcher Richtlinie mit dem Anspruch, die bestehende Normung um die luftgekoppelte Prüfung zu erweitern und somit die Vereinheitlichung der Charakterisierung dieser Wandler zu erleichtern. In diesem Beitrag wird ein Überblick über den geplanten Inhalt der Richtlinie und über die Methoden zur akustischen Charakterisierung von luftgekoppelten Ultraschallwandlern gegeben. Insbesondere werden verschiedene Methoden der Ermittlung von wichtigen Wandlerparametern wie z.B. Empfindlichkeit, Mittenfrequenz, Bandbreite, Fokusgröße und Fokusabstand dargestellt und verglichen. T2 - DGZfP-Jahrestagung CY - Kassel, Germany DA - 23.05.2022 KW - Lutgekoppelte Ultraschallprüfung KW - Prüfkopf KW - Charakterisierung KW - Richtlinie PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552918 SP - 1 EP - 7 AN - OPUS4-55291 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Essig, W. A1 - Bernhardt, Y. A1 - Döring, D. A1 - Solodov, I. A1 - Gautzsch, T. A1 - Gaal, Mate A1 - Hufschläger, Daniel A1 - Sommerhuber, R. A1 - Marhenke, T. A1 - Hasener, J. A1 - Szewieczek, A. A1 - Hillger, W. T1 - Air-coupled ultrasound - emerging NDT method N2 - This paper deals with the state of the art of air-coupled ultrasonic testing. KW - Air-coupled KW - Ultrasonic testing KW - Transducers PY - 2021 SN - 1616-069X VL - 173 SP - 32 EP - 43 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-52231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -