TY - CONF A1 - Knabe, C. A1 - Gildenhaar, Renate A1 - Berger, R. A1 - Ostapowicz, W. A1 - Fitzner, R. A1 - Radlanski, R. A1 - Gross, U. A1 - Siebert, G. T1 - In vitro examination of novel calcium phosphates using osteogenic cultures T2 - 5th World Biomaterials Congress CY - Toronto, Canada DA - 1996-05-29 KW - In-vitro Untersuchung KW - Kalzium-Phosphat KW - Zahnersatz KW - Knochen PY - 1996 VL - 1 SP - 890 CY - Toronto AN - OPUS4-672 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wildgruber, M. A1 - Lueg, C. A1 - Borgmeyer, S. A1 - Karimov, I. A1 - Braun, Ulrike A1 - Kiechle, M. A1 - Meier, R. A1 - Koehler, M. A1 - Ettl, J. A1 - Berger, H. T1 - Polyurethane versus silicone catheters for central venous port devices implanted at the forearm N2 - Purpose: We aimed to analyse short and long-term complications of polyurethane (PU) versus silicone catheters used in totally implantable venous-access ports (TIVAPs) implanted at the forearm. Methods: Retrospective analysis of 698 consecutively implanted TIVAPs was performed. Primary end-points were defined as rates of major complications associated with either type of central venous port catheter. Technical success rate, device service interval as well as minor complications not requiring port explantation were defined as secondary end-points. Results: A total of 698 port devices were implanted in 681 patients, 396 equipped with a PU catheter, 302 with a silicone catheter. The technical success rate was 99.9% with no major periprocedural complications. During follow-up a total of 211 complications in 146 patients were observed (1.0/1000 catheter days), 183 occurred associated with PU catheters (1.8/100 catheter days), 28 (0.3/1000 catheter days) with silicone catheters (log rank test p < 0.0001). Catheter-related bloodstream infections as well as thrombotic complications occurred significantly more frequently with PU catheters, while silicone catheters exhibited a trend towards a higher rate of mechanical failure such as disconnection or catheter rupture. Major complications requiring explantation of the device occurred more frequently with PU-based catheters (10.6%) compared to silicone catheter carrying ports (4.6%, log rank test p < 0.001). KW - Chemotherapy KW - Central venous access port KW - Complication KW - Thrombosis KW - Infection PY - 2016 DO - https://doi.org/10.1016/j.ejca.2016.02.011 SN - 0959-8049 VL - 59 SP - 113 EP - 124 PB - Elsevier Ltd. CY - Oxford, UK AN - OPUS4-36288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winkler, T. A1 - Hoenig, E. A1 - Huber, G. A1 - Janssen, R. A1 - Fritsch, D. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Morlock, M.M. A1 - Schilling, A.F. T1 - Osteoclastic bioresorption of biomaterials: Two- and three-dimensional imaging and quantification N2 - Purpose: Bioresorbable materials have been developed in the hope that the body will replace them with newly formed tissue. The first step of this remodeling process in bone is the bioresorption of the material by osteoclasts. The aim of this study was to analyze osteoclastic resorption of biomaterials in vitro using the commonly used two-dimensional methods of light-microscopy (LM) and scanning electron microscopy (SEM) in comparison with infinite focus microscopy (IFM), a recently developed imaging method allowing for three-dimensional surface analysis. Methods: Human hematopoietic stem cells were cultivated in the presence of the cytokines M-CSF and RANK-L for 4 weeks directly on dentin and a calcium phosphate cement. Osteoclast development was surveyed with standard techniques. After removal of the cells, resorption was characterized and quantified by LM, SEM and IFM. Results: Osteoclast cultures on the biomaterials presented the typical osteoclast-specific markers. On dentin samples LM, SEM as well as IFM allowed for discrimination of resorption. Quantification of the resorbed area showed a linear correlation between the results (LM vs. SEM: r=0.996, p=0.004; SEM vs. IFM: r=0.989, p=0.011; IFM vs. LM: r=0.995). It was not possible to demarcate resorption pits on GB14 using LM or SEM. With IFM, resorption on GB14 could be visualized and quantified two- and three-dimensionally. KW - Biomaterial KW - Three-dimensional KW - IFM KW - Osteoclast KW - Dentin KW - Calcium phosphate PY - 2010 SN - 0391-3988 VL - 33 IS - 4 SP - 198 EP - 203 PB - Wichtig Ed. CY - Milano [u.a.] AN - OPUS4-21621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winkler, T. A1 - Hoenig, E. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Fritsch, D. A1 - Janssen, R. A1 - Morlock, M.M. A1 - Schilling, A.F. T1 - Volumetric analysis of osteoclastic bioresorption of calcium phosphate ceramics with different solubilities N2 - Commonly, to determine osteoclastic resorption of biomaterials only the resorbed area is measured. The depth of the resorption pit, however, may also be important for the performance of a material. To generate such data we used two calcium phosphate ceramics (Ca10 and Ca2). The solubility of the materials was determined according to DIN EN ISO 10993-14. They were scanned three-dimensionally using infinite focus microscopy and subsequently cultivated for 4 weeks in simulated body fluid without (control) or with human osteoclasts. After this cultivation period osteoclasts number was determined and surface changes were evaluated two- and three-dimensionally. Ca10 and Ca2 showed solubilities of 11.0 ± 0.5 and 23.0 ± 2.2 mg g-1, respectively. Both materials induced a significant increase in osteoclast number. While Ca10 did not show osteoclastic resorption, Ca2 showed an increased pit area and pit volume due to osteoclastic action. This was caused by an increased average pit depth and an increased number of pits, while the average area of single pits did not change significantly. The deduced volumetric osteoclastic resorption rate (vORR) of Ca2 (0.01–0.02 µm3 µm-2 day-1) was lower than the remodelling speed observed in vivo (0.08 µm3 µm-2 day-1), which is in line with the observation that implanted resorbable materials remain in the body longer than originally expected. Determination of volumetric indices of osteoclastic resorption might be valuable in obtaining additional information about cellular resorption of bone substitute materials. This may help facilitate the development of novel materials for bone substitution. KW - Biodegradation KW - Surface analysis KW - Simulated body fluid KW - Osteoclasts KW - Calcium phosphate ceramics PY - 2010 DO - https://doi.org/10.1016/j.actbio.2010.04.015 SN - 1742-7061 VL - 6 IS - 10 SP - 4127 EP - 4135 PB - Elsevier CY - Amsterdam AN - OPUS4-22554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolff, Timo A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Nissen, J. A1 - Berger, D. A1 - Zizak, I. A1 - Sokaras, D. A1 - Karydas, A. A1 - Grlj, N. A1 - Pelicon, P. A1 - Schütz, R. A1 - Zitniki, M. A1 - Kanngießer, B. T1 - Performance of a polycapillary halflens as focussing and collecting optic - a comparison N2 - Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters. PY - 2009 DO - https://doi.org/10.1039/b817828c SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 669 EP - 675 PB - Royal Society of Chemistry CY - London AN - OPUS4-19415 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ma, L. A1 - Feng, L. A1 - Hioki, A. A1 - Cho, K.H. A1 - Vogl, Jochen A1 - Berger, Achim A1 - Turk, G. A1 - Macleod, S. A1 - Labarraque, G. A1 - Tong, W.F. A1 - Schiel, D. A1 - Yafa, C. A1 - Valiente, L. A1 - Konopelko, L.A. A1 - Quetel, C. A1 - Vermaercke, P. A1 - Manzano, J.V.L. A1 - Linsky, M. A1 - Cortés, E. A1 - Tangpitayakul, S. A1 - Plangsangmas, L. A1 - Bergamaschi, L. A1 - Hearn, R. T1 - International comparison of the determination of the mass fraction of cadmium, chromium, mercury and lead in polypropylene: the Comité Consultatif pour la quantité de matière pilot study CCQM-P106 KW - Cadmium KW - Chromium KW - Mercury KW - Lead KW - Polypropylene KW - CCQM PY - 2010 DO - https://doi.org/10.1007/s00769-009-0574-z SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 39 EP - 44 PB - Springer CY - Berlin AN - OPUS4-20787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bernstein, A. A1 - Berger, Georg A1 - Brandt, J. A1 - Wenkel, R. A1 - Gildenhaar, Renate A1 - Zielezinski, T. A1 - Nöbel, D. T1 - Calciumtitanat (Ca4Ti3O10) - ein neues Material für Implantatbeschichtungen KW - Implantatbeschichtung KW - Calciumtitanat KW - Bioaktivität KW - Knochenkontakt KW - Biomaterial-bone-coating of an implant PY - 2004 SN - 1616-0177 SN - 0011-8656 VL - 5 IS - 4 SP - 242 EP - 248 PB - Verl. Neuer Merkur CY - München AN - OPUS4-6010 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pritzkow, Wolfgang A1 - Vogl, Jochen A1 - Berger, Achim A1 - Ecker, Klaus A1 - Grötzschel, R. A1 - Klingbeil, Patrick A1 - Persson, L. A1 - Riebe, Gundel A1 - Wätjen, U. T1 - Contribution of ICP-IDMS to the certification of antimony implanted in a silicon wafer - comparison with RBS and INAA results N2 - A thin-layer reference material for surface and near-surface analytical methods was produced and certified. The surface density of the implanted Sb layer was determined by Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA), and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) equipped with a multi-collector. The isotopic abundances of Sb (121Sb and 123Sb) were determined by multi-collector ICP-MS and INAA. ICP-IDMS measurements are discussed in detail in this paper. All methods produced values traceable to the SI and are accompanied by a complete uncertainty budget. The homogeneity of the material was measured with RBS. From these measurements the standard uncertainty due to possible inhomogeneities was estimated to be less than 0.78% for fractions of the area increments down to 0.75 mm2 in size. Excellent agreement between the results of the three different methods was found. For the surface density of implanted Sb atoms the unweighted mean value of the means of four data sets is 4.8121016 cm-2 with an expanded uncertainty (coverage factor k=2) of 0.0921016 cm-2. For the isotope amount ratio R (121Sb/123Sb) the unweighted mean value of the means of two data sets is 1.435 with an expanded uncertainty (coverage factor k=2) of 0.006. KW - ICP-MS KW - IDMS KW - Reference material KW - Surface analysis PY - 2001 DO - https://doi.org/10.1007/s002160100987 SN - 0937-0633 VL - 371 SP - 867 EP - 873 PB - Springer CY - Berlin AN - OPUS4-7220 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knabe, C. A1 - Howlett, C. R. A1 - Markovic, B. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Zreiqat, H. T1 - The Functional Expression of Osteoblasts Grown on Rapid Resorbable Calcium Phosphates T2 - 15th International Symposium on Ceramics in Medicine ; 15th Annual meeting of the International Society for Ceramics in Medicine ; 15th Bioceramics CY - Sydney, NSW, Australia DA - 2002-12-04 KW - Guided bone regeneration KW - Calcium alkali orthophosphates KW - Osteoblasts KW - Cell differentiation PY - 2003 SN - 1013-9826 VL - 240-242 SP - 679 EP - 682 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-2115 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, L.-M. A1 - Woydt, Mathias A1 - Keller, H. A1 - Zimmermann, S. A1 - Schwier, G. A1 - Enzl, R. A1 - Thiele, S. T1 - Tribological behaviour of HVOF-sprayed Cr3C2-NiCr and TiC-based coatings under high temperature dry sliding conditions N2 - In the current study, the tribological properties of TiC-based coatings paired with polycrystalline alumina under unlubricated sliding conditions were investigated in order to demonstrate the technological and engineering potential of such coatings. (Ti,Mo)(C,N)-Co coatings were prepared from an agglomerated and sintered spray powder by HVOF spraying using JP-5000 equipment. Cr3C2-NiCr coatings were studied for comparison. Sliding wear tests were performed over the temperature range from 23°C to 800°C with sliding speeds in the range 0.3-3 m/s, a wear distance of 5000 m and a normal force of 10 N. Wear rates of coatings and sintered alumina counterparts were measured separately. Compared with Cr3C2-NiCr coatings, (Ti,Mo)(C,N)-Co coatings showed significantly lower total wear rates, corresponding to those found in the region of mixed/boundary lubrication. With few exceptions, the coefficients of friction were found to be lower for (Ti,Mo)(C,N)-Co coatings than for Cr3C2-NiCr coatings. After tests were performed, the coating microstructures were studied by optical microscopy and SEM. The oxide scales formed on the coating surfaces were investigated by SEM and X-ray diffraction. Comparison of the total wear rates of the couples consisting of sintered alumina and a (Ti,Mo)(C,N)-Co coating with those of other alumina-ceramic and hardmetal-hard metal tribological systems demonstrates the immense potential of TiC-based coatings for sliding wear applications. T2 - International Thermal Spray Conference & Exposition 2004 CY - Osaka, Japan DA - 2004-05-10 PY - 2004 SN - 3-87155-792-7 SP - 1(?) EP - 10(?) PB - DVS-Verl. CY - Düsseldorf AN - OPUS4-5123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Berger, Georg A1 - Mensing, M. A1 - Müller-Mai, C. A1 - Gross, U. A1 - Rahmanzadeh, R. A1 - Sittinger, M. T1 - Bioresorbable carriers for subchondral anchoring of tissue-engineered cartilage in articular defects T2 - 3rd Biennial Meeting of the Tissue Engineering Society International (TESI) CY - Lake Buena Vista, FL, USA DA - 2000-11-30 PY - 2000 AN - OPUS4-1042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Driessens, F. C. M. A1 - De Maeyer, E. A. P. A1 - Fernández, E. A1 - Boltong, M. G. A1 - Berger, Georg A1 - Verbeeck, R. M. H. A1 - Ginebra, M. P. A1 - Planell, J. A. T1 - Amorphous calcium phosphate cements and their transformation into calcium deficient hydroxyapatite KW - Zement KW - Kalzium-Phosphat PY - 1996 VL - 9 SP - 231 EP - 234 AN - OPUS4-704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, Georg A1 - Mensing, M. A1 - Sittinger, M. A1 - Gross, U. A1 - Rahmanzadeh, R. A1 - Müller-Mai, C. ED - Haas, N. P. T1 - Autologe Chondrozyten Transplantation durch Tissue Engineering auf resorbierbaren bioaktiven Biomaterialträgern T2 - 64. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie CY - Hannover, Deutschland DA - 2000-09-10 PY - 2000 SN - 3-540-67734-8 SN - 0945-1382 N1 - Serientitel: Hefte zur Zeitschrift "Der Unfallchirurg" – Series title: Hefte zur Zeitschrift "Der Unfallchirurg" IS - 282 SP - 1(?) PB - Springer CY - Berlin AN - OPUS4-948 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Driessens, F. C. M. A1 - Boltong, M. G. A1 - Fernández, E. A1 - Ginebra, M. P. A1 - Planell, J. A. A1 - Verbeeck, R. M. H. A1 - De Maeyer, E. A. P. A1 - Berger, Georg T1 - Amorphous calcium phosphate cements T2 - 5th World Biomaterials Congress CY - Toronto, Canada DA - 1996-05-29 KW - Kalzium Phosphat Zement, amorph. PY - 1996 VL - 2 SP - 346 CY - Toronto AN - OPUS4-673 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Lugscheider, E. A1 - Berger, Georg A1 - Knepper, M. A1 - Sicking, R. A1 - Nyland, A. ED - Wilson, J. ED - Hench, L. T1 - Plasma Spreyed Coatings of Calcium Titanium Phosphate - A New Generation of Bioactive Coatings T2 - 8th International Symposium on Ceramics in Medicine CY - Ponte Vedra, FL, USA DA - 1995-11-01 KW - Plasmasprühen KW - Überzug KW - Schutzschicht KW - Bioaktiv PY - 1995 SN - 0-08-042677-8 DO - https://doi.org/10.1016/S0109-5641(96)80046-7 VL - 8 SP - 317 EP - 322 PB - Elsevier Science CY - Oxford AN - OPUS4-602 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kalbe, Ute A1 - Berger, Wolfgang A1 - Freyas, R. A1 - Eberle, S.H. T1 - Reproduzierbarkeit von Säulenperkolationsversuchen - Empfehlungen für die Durchführung KW - Auslaugungsverfahren KW - Sickerwasserprognose KW - Quellstärkebestimmung KW - Säulenversuche KW - Kontaminierter Boden KW - Abfallmaterialien PY - 2006 SN - 0942-3818 SN - 1864-8371 VL - 15 IS - 6 SP - 310 EP - 315 PB - Schmidt CY - Berlin AN - OPUS4-14301 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Batatia, Ilyes A1 - Benner, Philipp A1 - Chiang, Yuan A1 - Elena, Alin M. A1 - Kovács, Dávid P. A1 - Riebesell, Janosh A1 - Advincula, Xavier R. A1 - Asta, Mark A1 - Avaylon, Matthew A1 - Baldwin, William J. A1 - Berger, Fabian A1 - Bernstein, Noam A1 - Bhowmik, Arghya A1 - Bigi, Filippo A1 - Blau, Samuel M. A1 - Cărare, Vlad A1 - Ceriotti, Michele A1 - Chong, Sanggyu A1 - Darby, James P. A1 - De, Sandip A1 - Della Pia, Flaviano A1 - Deringer, Volker L. A1 - Elijošius, Rokas A1 - El-Machachi, Zakariya A1 - Fako, Edvin A1 - Falcioni, Fabio A1 - Ferrari, Andrea C. A1 - Gardner, John L. A. A1 - Gawkowski, Mikołaj J. A1 - Genreith-Schriever, Annalena A1 - George, Janine A1 - Goodall, Rhys E. A. A1 - Grandel, Jonas A1 - Grey, Clare P. A1 - Grigorev, Petr A1 - Han, Shuang A1 - Handley, Will A1 - Heenen, Hendrik H. A1 - Hermansson, Kersti A1 - Ho, Cheuk Hin A1 - Hofmann, Stephan A1 - Holm, Christian A1 - Jaafar, Jad A1 - Jakob, Konstantin S. A1 - Jung, Hyunwook A1 - Kapil, Venkat A1 - Kaplan, Aaron D. A1 - Karimitari, Nima A1 - Naik, Aakash A. A1 - Csányi, Gábor T1 - A foundation model for atomistic materials chemistry N2 - Atomistic simulations of matter, especially those that leverage first-principles (ab initio) electronic structure theory, provide a microscopic view of the world, underpinning much of our understanding of chemistry and materials science. Over the last decade or so, machine-learned force fields have transformed atomistic modeling by enabling simulations of ab initio quality over unprecedented time and length scales. However, early machine-learning (ML) force fields have largely been limited by (i) the substantial computational and human effort required to develop and validate potentials for each particular system of interest and (ii) a general lack of transferability from one chemical system to the next. Here, we show that it is possible to create a general-purpose atomistic ML model, trained on a public dataset of moderate size, that is capable of running stable molecular dynamics for a wide range of molecules and materials. We demonstrate the power of the MACE-MP-0 model—and its qualitative and at times quantitative accuracy—on a diverse set of problems in the physical sciences, including properties of solids, liquids, gases, chemical reactions, interfaces, and even the dynamics of a small protein. The model can be applied out of the box as a starting or “foundation” model for any atomistic system of interest and, when desired, can be fine-tuned on just a handful of application-specific data points to reach ab initio accuracy. Establishing that a stable force-field model can cover almost all materials changes atomistic modeling in a fundamental way: experienced users obtain reliable results much faster, and beginners face a lower barrier to entry. Foundation models thus represent a step toward democratizing the revolution in atomic-scale modeling that has been brought about by ML force fields. KW - Materials Design KW - Thermal Conducitivity KW - Nanoparticles KW - Batteries PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647829 DO - https://doi.org/10.1063/5.0297006 SN - 0021-9606 VL - 163 IS - 18 SP - 1 EP - 89 PB - AIP Publishing AN - OPUS4-64782 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knabe, C. A1 - Stiller, M. A1 - Kampschulte, M. A1 - Wilbig, Janka A1 - Peleska, B. A1 - Günster, Jens A1 - Gildenhaar, R. A1 - Berger, G. A1 - Rack, A. A1 - Linow, U. A1 - Heiland, M. A1 - Rendenbach, C. A1 - Koerdt, S. A1 - Steffen, C. A1 - Houshmand, A. A1 - Xiang-Tischhauser, L. A1 - Adel-Khattab, D. T1 - A tissue engineered 3D printed calcium alkali phosphate bioceramic bone graft enables vascularization and regeneration of critical-size discontinuity bony defects in vivo N2 - Recently, efforts towards the development of patient-specific 3D printed scaffolds for bone tissue engineering from bioactive ceramics have continuously intensified. For reconstruction of segmental defects after subtotal mandibulectomy a suitable tissue engineered bioceramic bone graft needs to be endowed with homogenously distributed osteoblasts in order to mimic the advantageous features of vascularized autologous fibula grafts, which represent the standard of care, contain osteogenic cells and are transplanted with the respective blood vessel. Consequently, inducing vascularization early on is pivotal for bone tissue engineering. The current study explored an advanced bone tissue engineering approach combining an advanced 3D printing technique for bioactive resorbable ceramic scaffolds with a perfusion cell culture technique for pre-colonization with mesenchymal stem cells, and with an intrinsic angiogenesis technique for regenerating critical size, segmental discontinuity defects in vivo applying a rat model. To this end, the effect of differing Si-CAOP (silica containing calcium alkali orthophosphate) scaffold microarchitecture arising from 3D powder bed printing (RP) or the Schwarzwalder Somers (SSM) replica fabrication technique on vascularization and bone regeneration was analyzed in vivo. In 80 rats 6-mm segmental discontinuity defects were created in the left femur. KW - Additive Manufacturing KW - Bio active ceramic KW - In-vivo KW - Alcium alkali phosphate PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-584555 DO - https://doi.org/10.3389/fbioe.2023.1221314 SN - 2296-4185 VL - 11 SP - 1 EP - 20 PB - Frontiers SA CY - Lausanne AN - OPUS4-58455 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Adel-Khattab, D. A1 - Giacomini, F. A1 - Gildenhaar, R. A1 - Berger, G. A1 - Gomes, Cynthia A1 - Linow, Ulf A1 - Hardt, M. A1 - Peleska, B. A1 - Günster, Jens A1 - Stiller, M. A1 - Houshmand, A. A1 - Ghaffar, K. A1 - Gamal, A. A1 - El-Mofty, M. A1 - Knabe, C. T1 - Development of a synthetic tissue engineered three- dimensional printed bioceramic-based bone graft with homogenously distributed osteoblasts and mineralizing bone matrix in vitro N2 - Over the last decade there have been increasing efforts to develop three-dimensional (3D) scaffolds for bone tissue Engineering from bioactive ceramics with 3D printing emerging as a promising technology. The overall objective of the present study was to generate a tissue engineered synthetic bone graft with homogenously distributed osteoblasts and mineralizing bone Matrix in vitro, thereby mimicking the advantageous properties of autogenous bone grafts and facilitating usage for reconstructing segmental discontinuity defects in vivo . To this end, 3D scaffolds were developed from a silica-containing calcium alkali orthophosphate, using, fi rst, a replica technique – the Schwartzwalder – Somers method – and, second, 3D printing, (i.e. rapid prototyping). The mechanical and physical scaffold properties and their potential to facilitate homogenous colonization by osteogenic cells and extracellular bone matrix formation throughout the porous scaffold architecture were examined. Osteoblastic cells were dynamically cultured for 7 days on both scaffold types with two different concentrations of 1.5 and 3 × 10⁹ cells/l. The amount of cells and bone matrix formed and osteogenic marker expression were evaluated using hard tissue histology, immunohistochemical and histomorphometric analysis. 3D-printed scaffolds (RPS) exhibited more micropores, greater compressive strength and silica release. RPS seeded with 3 × 10⁹ cells/l displayed greatest cell and extracellular Matrix formation, mineralization and osteocalcin expression. In conclusion, RPS displayed superior mechanical and biological properties and facilitated generating a tissue engineered synthetic bone graft in vitro, which mimics the advantageous properties of autogenous bone grafts, by containing homogenously distributed terminally differentiated osteoblasts and mineralizing bone matrix and therefore is suitable for subsequent in vivo implantation for regenerating segmental discontinuity bone defects. KW - Bone tissue engineering KW - Calcium alkali orthophosphate KW - Rapid prototyping KW - Scaffold KW - Mandible PY - 2017 DO - https://doi.org/10.1002/term.2362 SN - 1932-6254 SN - 1932-7005 VL - 12 IS - 1 SP - 44 EP - 58 PB - Wiley Online Library AN - OPUS4-40745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braun, Ulrike A1 - Lorenz, Edelgard A1 - Weimann, Christiane A1 - Sturm, Heinz A1 - Karimov, I. A1 - Ettl, J. A1 - Meier, R. A1 - Wohlgemuth, W. A. A1 - Berger, H. A1 - Wildgruber, M. T1 - Mechanic and surface properties of central-venous port catheters after removal: A comparison of polyurethane and Silicon rubber materials N2 - Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU)and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, where as the samples after removal were compared according to the implanted time inpatient. The macroscopic,mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was an alysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure,especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture. KW - Thermoplastic polyurethane (TPU) KW - Silicone rubber (SiR) KW - Catheters KW - Central venous access port KW - Complication KW - Structure propertyrelationship KW - Mechanical testing PY - 2016 DO - https://doi.org/10.1016/j.jmbbm.2016.08.002 SN - 1751-6161 SN - 1878-0180 VL - 64 SP - 281 EP - 291 PB - Elsevier Ltd. AN - OPUS4-37178 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Hodoroaba, Vasile-Dan A1 - Terborg, R. A1 - Berger, D. T1 - Determination of the Effective Detector Area of an Energy-Dispersive X-Ray Spectrometer at the Scanning Electron Microscope Using Experimental and Theoretical X-Ray Emission Yields N2 - A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description. KW - Energy-dispersive X-ray spectrometer (EDS) KW - EDX KW - Effective area KW - X-ray emission yield KW - Geometrical collection efficiency PY - 2016 UR - https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/div-classtitledetermination-of-the-effective-detector-area-of-an-energy-dispersive-x-ray-spectrometer-at-the-scanning-electron-microscope-using-experimental-and-theoretical-x-ray-emission-yieldsdiv/E15B2E67C349201CF323E778EB9C6D94 DO - https://doi.org/10.1017/S1431927616011788 VL - 22 IS - 6 SP - 1360 EP - 1368 PB - Cambridge University Press CY - New York, NY, USA AN - OPUS4-38858 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ortel, Erik A1 - Hertwig, Andreas A1 - Berger, D. A1 - Esposito, P. A1 - Rossi, A. M. A1 - Kraehnert, R. A1 - Hodoroaba, Vasile-Dan T1 - New approach on quantification of porosity of thin films via electron-excited X‑ray spectra N2 - One of the crucial characteristics of functionalized thin films is their porosity (i.e., the ratio between the pore volume and the volume of the whole film). Due to the very low amount of material per coated area corresponding to thin films, it is a challenge for analytics to measure the film porosity. In this work, we present an Approach to determine the porosity of thin films by means of electron probe microanalysis (EPMA) either by wavelength-dispersive X-ray spectrometry (WDX) or by energy-dispersive X-ray spectrometry (EDX) with a scanning electron microscope (SEM). The procedure is based on the calculation of the film mass deposition from electron-excited X-ray spectra. The mass deposition is converted into film density by division of measured film thickness. Finally, the film porosity is calculated from the measured film density and the density of bulk, nonporous film material. The general applicability of the procedure to determine the porosity is demonstrated on thin templated mesoporous TiO₂ films, dip-coated on silicon wafer, with controlled porosity in the range of 15 to 50%. The high accuracy of the mass deposition as determined from X-ray spectra was validated with independent methods (ICP-OES and weighing). Furthermore, for the validation of the porosity results, ellipsometry, interference fringes method (IFM), and focused ion beam (FIB) cross sectioning were employed as independent techniques. Hence, the approach proposed in the present study is proven to be suited as a new analytical tool for accurate and relatively fast determination of the porosity of thin films. KW - Porosity KW - X-rays KW - EDX KW - Thin film KW - TiO2 KW - Density KW - Mass deposition KW - STRATAGem PY - 2016 UR - http://pubs.acs.org/doi/abs/10.1021/acs.analchem.6b00847 DO - https://doi.org/10.1021/acs.analchem.6b00847 VL - 88 IS - 14 SP - 7083 EP - 7090 PB - ACS Publications CY - 1155 Sixteenth Street N.W., Washington, DC 20036 AN - OPUS4-36911 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Genga, R. M. A1 - Conze, S. A1 - Berger, L.M. A1 - Pötschke, J. A1 - Witte, Julien A1 - Schröpfer, D. A1 - Cermak, A. A1 - Zeman, P. A1 - Ngongo, S. A1 - Janse van Vuuren, A. T1 - Enhanced Fe and Ni bonded NbC Laser Surface Engineered based Hardmetals: Alternative Cutter Materials for Electric Vehicle Applications N2 - The efforts to substitute both tungsten carbide (WC) and cobalt (Co) has gained prominence in recent years due to the classification of Co as a carcinogen and the classification of Co and W as critical raw materials in the EU as well as within regulations of the U.S. National Toxicology Program. In this study, substitution of both WC and Co with advanced hardmetals consisting of NbC with Ni and Fe-based metal binders are investigated for their use of machining of metals used electric vehicle manufacturing. The developed NbC-Ni/Fe based hardmetals employ a Machining Property Led Tailored Design (MPLTD) approach. This reverse engineering strategy uses data from machining performance to guide the development of microstructural, mechanical, and behavioral properties. Four advanced NbC-based hardmetals were produced, two with Ni-based binders and two with Fe-based binders, along with two reference materials for comparison (WC-Co and straight NbC-12Ni). Hardmetals were characterized using field emission scanning electron microscopy (FE-SEM), annular dark-field scanning transmission electron microscopy (ADF-STEM), Vickers hardness, fracture toughness, and elastic moduli. Cutting tool inserts were manufactured from the developed hardmetals and enhanced using femto-second laser surface engineering. The inserts’ performance was evaluated through face milling tests on AZ31 automotive magnesium alloy, providing insights into their suitability for high-demand industrial applications. T2 - 21. Plansee Seminar CY - Reutte, Österreich DA - 01.06.2025 KW - Niobium carbide KW - Alternative binders KW - Alternative hard phases KW - Face milling KW - AZ31 magnesium alloy PY - 2025 VL - 2025 SP - 1 EP - 10 AN - OPUS4-65382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reiche, I. A1 - Berger, Achim A1 - Duval, A. A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Schäfer, D. A1 - Simon, R. T1 - SY-XRF study of Hans Baldung Grien silverpoint drawings and the silver stylus from the 'Karlsruhe sketchbook' N2 - We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period. KW - Synchrotron KW - XRF analysis KW - Drawings KW - Silver stylus PY - 2007 DO - https://doi.org/10.1002/xrs.963 SN - 0049-8246 VL - 36 IS - 3 SP - 173 EP - 177 PB - Wiley CY - Chichester AN - OPUS4-16150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Ecker, K. H. A1 - Wätjen, U. A1 - Berger, Achim A1 - Grötzschel, R. A1 - Persson, L. A1 - Pritzkow, W. A1 - Radtke, Martin A1 - Riebe, Gundel A1 - Riesemeier, Heinrich A1 - Vogl, Jochen T1 - Certification of antimony implanted in silicon wafer with a silicon dioxide diffusion barrier - IRMM-302 and BAM-L001 N2 - This Report describes the certification of the reference material antimony implanted in Si/SiO2 intended to be used for calibration of surface and near surface analytical methods. It describes the preparation, homogeneity measurements and the analytical work performed for the certification of both Areal density of antimony Atoms (retained dose) and the isotope amount Ratio as well as giving considerations on the stability of the material. KW - Isotope ratio KW - Areal density KW - Surface analysis PY - 2002 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355752 SP - 1 EP - 40 PB - Institute for Reference Materials and Measurements CY - Geel, Belgium AN - OPUS4-35575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berger, J. A1 - Zahedi-Azad, S. A1 - Voss, H. A1 - Ernst, O.C. A1 - Hammerschmidt, R. A1 - Boeck, T. A1 - Martin, J. A1 - Bonse, J. A1 - Krüger, J. A1 - Schmid, M. T1 - CuInSe2-based micro-concentrator solar cells fabricated from In islands grown by laser-assisted MO-CVD N2 - Micro-concentrator solar cells offer a promising route for reducing material usage in photovoltaics. For Cu(In,Ga)Se2, multiple micro-concentrator manufacturing methods have already been evaluated. All of them involve either high preparation complexity or post-processing to recycle unused precursor or absorber materials. In this work, a new method using laser-assisted metal-organic chemical vapor deposition (LA-MOCVD) was applied to directly grow arrays of indium micro-islands. These arrays are examined and further processed to CuInSe2 micro-solar cell arrays. The geometry and morphology of the islands were investigated and compared before and after absorber formation. The investigation shows that the absorber growth is limited to the vertical direction normal to the substrate surface and that the starting morphology is preserved. Furthermore, the absorber island arrays are processed into micro-modules and operational solar cells are achieved as a proof of principle. These not yet optimized arrays reach a conversion efficiency of 0.65% under 1 sun illumination. Under 17 suns of light concentration, the efficiency gain is between 60 and 250%. This work demonstrates the method's viability for the fabrication of micro-solar cell arrays, with clear potential for achieving higher conversion efficiencies through future optimization. KW - Micro-concentrator solar cells KW - Laser-assisted chemical vapor deposition KW - CISe KW - Bottom-up fabrication KW - Resource efficiency PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656711 DO - https://doi.org/10.1016/j.solmat.2026.114284 SN - 0927-0248 VL - 301 SP - 1 EP - 10 PB - Elsevier B.V. AN - OPUS4-65671 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knabe, Ch. A1 - Berger, Georg A1 - Gildenhaar, Renate A1 - Howlett, C.R. A1 - Markovic, B. A1 - Zreiqat, H. T1 - The functional expression of human bone-derived cells grown on rapidly resorbable calcium phosphate ceramics N2 - The use of biodegradable bone substitutes is advantageous for alveolar ridge augmentation, since it avoids second-site surgery for autograft harvesting. This study examines the effect of novel, rapidly resorbable calcium phosphates on the expression of bone-related genes and proteins by human bone-derived cells (HBDC) and compares this behavior to that of tricalciumphosphate (TCP). Test materials were a-TCP, and four materials which were created from ß-Rhenanite and its derivatives: R1-ß-Rhenanite (CaNaPO4); R1/M2 composed of CaNaPO4 and MgNaPO4; R1+SiO2 composed of CaNaPO4 and 9% SiO2 (wt%); and R17-Ca2KNa(PO4)2. HBDC were grown on the substrata for 3, 5, 7, 14 and 21 days, counted and probed for various mRNAs and proteins (Type I collagen, osteocalcin, osteopontin, osteonectin, alkaline phosphatase and bone sialoprotein). All substrata supported continuous cellular growth for 21 days. At day 21, surfaces of R1+SiO2 and R17 had the highest number of HBDC. At 14 and 21 days, cells on R1 and on R1+SiO2 displayed significantly enhanced expression of all osteogenic proteins. Since all novel calcium phosphates supported cellular proliferation together with expression of bone-related proteins at least as much as TCP, these ceramics can be regarded as potential bone substitutes. R1 and R1+SiO2 had the most effect on osteoblastic differentiation, thus suggesting that these materials may possess a higher potency to enhance osteogenesis than TCP. KW - Calcium phosphate ceramics KW - Human bone-derived cells KW - Cell-biomaterial interactions KW - Bone substitutes KW - In situ hybridization PY - 2004 DO - https://doi.org/10.1016/S0142-9612(03)00525-8 SN - 0142-9612 VL - 25 IS - 2 SP - 335 EP - 344 PB - Elsevier CY - Oxford AN - OPUS4-2957 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Knabe, C. A1 - Howlett, C.R. A1 - Markovic, B. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Zreiqat, H. T1 - Beeinflussung der Gen- und Proteinexpression von Osteoblasten durch bioaktive resorbierbare Glaskeramiken T2 - Bericht der 2. gemeinsamen Jahrestagung der Deutschen Gesellschaft für Implantologie im Zahn-, Mund- und Kieferbereich, der Österreichischen Gesellschaft für orale Chirurgie und Implantologie sowie der Schweizerischen Gesellschaft für orale Implantologie CY - München, Deutschland DA - 2002-12-05 PY - 2002 AN - OPUS4-1898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Arndt, R.W. A1 - Grosse, C.U, A1 - Maehner, D. A1 - Niederleithinger, Ernst A1 - Taffe, A. A1 - Algernon, D. A1 - Berger, J. A1 - Kessler, S. A1 - Krueger, M. A1 - Kruschwitz, Sabine A1 - Ufermann-Wallmeier, D. A1 - Walther, A. T1 - Non-destructive testing in civil engineering: A memorandum for teaching at German-speaking universities N2 - This contribution summarizes actual developments and draft fundamental teaching topics in the field of nondestructive testing in civil engineering (NDT-CE). It is based on the first memorandum on teaching and research in the field of NDT-CE at German speaking universities and provides an overview of the academic education and highlights possible focuses, especially in teaching but also takes into account noteworthy developments and topics in research in the field of NDT-CE. Suggestions are given for the development and advancement of the teaching curricula in regards to a comprehensive and sound professional education of students in civil engineering and adjacent disciplines. T2 - NDT-CE 2022 CY - Zurich, Switzerland DA - 16.08.2022 KW - Curriculum KW - NDT-CE KW - University KW - Competencies PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-563269 UR - https://www.ndt.net/article/ndtce2022/paper/61547_manuscript.pdf SP - 1 EP - 10 PB - NDT.net AN - OPUS4-56326 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -