TY - JOUR A1 - Nilsson, R. H. A1 - Taylor, A. F. S. A1 - Adams, R. I. A1 - Baschien, C. A1 - Bengtsson-Palme, J. A1 - Cangren, P. A1 - Coleine, C. A1 - Iršėnaitė, R. A1 - Martin-Sanchez, Pedro Maria A1 - Meyer, W. A1 - Oh, S.-Y. A1 - Sampaio, J. P. A1 - Seifert, K. A. A1 - Sklenář, F. A1 - Stubbe, D. A1 - Suh, S.-O. A1 - Summerbell, R. A1 - Svantesson, S. A1 - Unterseher, M. A1 - Visagie, C. M. A1 - Weiss, M. A1 - Woudenberg, J. HC. A1 - Wurzbacher, C. A1 - Van den Wyngaert, S. A1 - Yilmaz, N. A1 - Yurkov, A. A1 - Kõljalg, U. A1 - Abarenkov, K. A1 - Daniel, H.-M. A1 - Glassman, S. I. A1 - Hirooka, H. A1 - Irinyi, L. T1 - Taxonomic annotation of public fungal ITS sequences from the built environment – a report from an April 10–11, 2017 workshop (Aberdeen, UK) N2 - Recent DNA-based studies have shown that the built environment is surprisingly rich in fungi. These indoor fungi – whether transient visitors or more persistent residents – may hold clues to the rising levels of human allergies and other medical and building-related health problems observed globally. The taxo¬nomic identity of these fungi is crucial in such pursuits. Molecular identification of the built mycobiome is no trivial undertaking, however, given the large number of unidentified, misidentified, and technically compromised fungal sequences in public sequence databases. In addition, the sequence metadata required to make informed taxonomic decisions – such as country and host/substrate of collection – are often lacking even from reference and ex-type sequences. Here we report on a taxonomic annotation workshop (April 10–11, 2017) organized at the James Hutton Institute/University of Aberdeen (UK) to facilitate reproducible studies of the built mycobiome. The 32 participants went through public fungal ITS bar¬code sequences related to the built mycobiome for taxonomic and nomenclatural correctness, technical quality, and metadata availability. A total of 19,508 changes – including 4,783 name changes, 14,121 metadata annotations, and the removal of 99 technically compromised sequences – were implemented in the UNITE database for molecular identification of fungi (https://unite.ut.ee/) and shared with a range of other databases and downstream resources. Among the genera that saw the largest number of changes were Penicillium, Talaromyces, Cladosporium, Acremonium, and Alternaria, all of them of significant importance in both culture-based and culture-independent surveys of the built environment. KW - Indoor mycobiome KW - Built environment KW - Molecular identification KW - Fungi KW - Taxonomy KW - Systematics KW - Sequence annotation KW - Metadata KW - Open data PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-438949 DO - https://doi.org/10.3897/mycokeys.28.20887 SN - 1314-4049 SN - 1314-4057 VL - 28 SP - 65 EP - 82 PB - Pensoft Publishers CY - Washington, DC AN - OPUS4-43894 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bernhardt, Y. A1 - Császár, L. A1 - Dengiz, N. A1 - Fuchs, M. A1 - Gaal, Mate A1 - Gautzsch, T. A1 - Gohlke, Dirk A1 - Hahn-Jose, T. A1 - Heckel, Thomas A1 - Hillger, W. A1 - Hufschläger, Daniel A1 - Ilse, D. A1 - Kiel, M. A1 - Kornely, M. A1 - Labud, P. A. A1 - Marhenke, T. A1 - Schubert, F. A1 - Sommerhuber, R. A1 - Steinhausen, R. A1 - Szewieczek, A. A1 - Wachter, L. A1 - Waschkies, T. T1 - Characterization and verification of air-coupled ultrasonic probes N2 - This guideline was drafted following and complementing the norm ISO 22232-2:2020(E) to include air-coupled ultrasonic transducers. This document specifies the characteristics of probes used for non-destructive air-coupled ultrasonic testing with center frequencies above 20 kHz, with focusing or without focusing means. KW - Air-coupled ultrasound KW - Ultrasonic testing KW - Guideline KW - Probe KW - Characterization PY - 2022 SN - 978-3-947971-26-8 VL - Guideline US 08 SP - 1 EP - 23 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin ET - Edition September 2022 AN - OPUS4-56228 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Siebler, Daniel A1 - Rohwetter, Philipp A1 - Brusenbach, R. A1 - Lothongkam, Chaiyaporn A1 - Heidmann, G. A1 - Leistner, A. A1 - Plath, R. T1 - Sensitivity-enhanced detection of partial discharge in cable accessories using fluorescent polymer optical fibre-sensor N2 - A new fluorescent polymer optical fibre sensor (F-POF) has been tested in combination with different single photon counting modules in real-scale model of a translucent high voltage (HV) stress cone for the detection of inner partial discharges (PDs). In experiments with different artificial PD sources these sensors were capable to detect discharges with an apparent Charge down to the limit of a few hundred femto Coulombs even with an unfavorable sensor location. By combining the datasets of the electrical and optical PD measurement (coincidence window ±100 ns) it is possible to suppress background noise and to undoubtedly assign signals to real inner PD events. First results of an optical/optical coincident PD measurement (coincidence interval ±100 ns) including an AC phase-correlated filtering show several coincident photon counts in the ränge of 1-2 pC over the whole Observation interval, indicating the potential ofthis new alternative PD measurement and evaluation method. T2 - POF 2014 - 23nd International conference on plastic optical fibers CY - Hiyoshi, Yokohama, Japan DA - 08.10.2014 KW - Polymer optical fibre KW - Partial discharge sensor KW - Fkuorescence KW - High voltage facility PY - 2014 SP - 1 EP - 5 AN - OPUS4-32531 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Siebler, Daniel A1 - Rohwetter, Philipp A1 - Lothongkam, Chaiyaporn A1 - Habel, Wolfgang A1 - Heidmann, G. A1 - Vaterrodt, K. A1 - Leistner, A. A1 - Leistner, A. A1 - Pepper, D. A1 - Brusenbach, R. A1 - Plath, R. T1 - Empfindliche optische Detektion von Teilentladungen in transparenten und transluzenten Silikonelastomeren T1 - Sensitive optical detection of partial discharges in transparent and translucent silicone elastomers N2 - Dieser Beitrag gibt einen Überblick über den gesamten optischen Übertragungsweg vom Ursprung der Teilentladungen (TE) in Kabelgarnituren bis zur Visualisierung der TE-Messergebnisse mit einem modernen digitalen TE-Messsystem. Hierzu zählen die relevanten Materialeigenschaften der in Frage kommenden Silikonelastomere, die Verwendung fluoreszierender Lichtwellenleiter als potentialfreie Licht-Sensoren und deren minimalinvasive Integration in die hochspannungstechnische Umgebung, die hochempfindliche Wandlung optischer in elektrische Signale sowie Ansätze zur Optimierung dieser Komponenten bzw. Teilsysteme. N2 - This paper deals with optical PD detection in cable accessories containing stress cones made of Silicon elastomer. It provides a survey on the optical and electrical PD propagation path from source to detection. This includes relevant material properties of possibly suited silicone elastomers, the use of fluorescent optical fibers for PD light detection, the minimally invasive integration into HV areas, high-sensitive optical-electrical signal conversion and concepts for optimization. T2 - 6. Fachtagung Diagnostik elektrischer Betriebsmittel CY - Berlin, Germany DA - 25.11.2014 KW - Optische Teilentladungsdetektion KW - Transparente Silikonelastomere KW - Elektrische Betriebsmittel PY - 2014 SN - 978-3-8007-3648-5 SP - 1 EP - 5 PB - VDE Verlag GmbH AN - OPUS4-32532 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Siebler, Daniel A1 - Hohberg, Michaela A1 - Rohwetter, Philipp A1 - Brusenbach, R. A1 - Plath, R. ED - Kalinowski, H.J. ED - Fabris, J.L. ED - Bock, W.J. T1 - Elastomeric fluorescent POF for partial discharge detection - recent progress N2 - We present recent progress in our development of fibre-optic sensors for the detection of partial discharge (PD) in silicone cable accessories, based on detecting related low-level optical emission. We experimentally show that the sensitive optical detection of PD can dramatically enhance the performance of conventional electrical PD measurement in electromagnetically noisy environments, and that it can yield high sensitivity and specificity even when no synchronous electrical PD measurement is conducted. This is demonstrated using a real-scale model of a high voltage cable accessory with a surface-attached conventional thermoplastic fluorescent polymer optical fibre (F-POF) sensor. In order to increase light collection efficiency, as a prerequisite for a commercially competitive implementation using cost-efficient detectors, sensing fibres will have to be integrated into the silicone rubber insulation, close to the potential origin of PD-induced damage. This is the rationale for our efforts to develop elastomeric fluorescent sensing fibres, tailored to the requirements of the application. We discuss specific challenges to be tackled and report on the successful implementation of all-silicone rubber fluorescent POF, to our best knowledge for the first time. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only. T2 - OFS2015 - 24rd International conference on optical fibre sensors CY - Curitiba, Brazil DA - 28.09.2015 KW - Elastomeric polymer optical fibre KW - Fluorescent POF KW - High voltage KW - Cable monitoring KW - Partial discharge KW - Silicone rubber KW - Cable accessories PY - 2015 SN - 9781628418392 DO - https://doi.org/10.1117/12.2194875 SN - 0277-786X N1 - Serientitel: Proceedings of SPIE – Series title: Proceedings of SPIE VL - 9634 SP - 96343W-1 EP - 96343W-4 AN - OPUS4-34539 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Anker, Andy S. A1 - Aspuru-Guzik, Alán A1 - Ben Mahmoud, Chiheb A1 - Bennett, Sophie A1 - Briling, Ksenia R. A1 - Changiarath, Arya A1 - Chong, Sanggyu A1 - Collins, Christopher M. A1 - Cooper, Andrew I. A1 - Crusius, Daniel A1 - Darmawan, Kevion K. A1 - Das, Basita A1 - David, Nicholas A1 - Day, Graeme M. A1 - Deringer, Volker L. A1 - Duarte, Fernanda A1 - Eardley-Brunt, Annabel A1 - Evans, Matthew L. A1 - Evans, Rob A1 - Fairlamb, Ian A1 - Franklin, Barnabas A. A1 - Frey, Jeremy A1 - Ganose, Alex M. A1 - Goulding, Mark A1 - Hafizi, Roohollah A1 - Hakkennes, Matthijs A1 - Hickey, Niamh A1 - James, Gillian A1 - Jelfs, Kim E. A1 - Kalikadien, Adarsh V. A1 - Kapil, Venkat A1 - Koczor-Benda, Zsuzsanna A1 - Krammer, Ferdinand A1 - Kulik, Heather J. A1 - Kumar, Vishank A1 - Kuttner, Christian A1 - Lam, Erwin A1 - Lou, Yuchen A1 - Mante, Eltjo A1 - Martin, Jennie A1 - Mroz, Austin M. A1 - Nematiaram, Tahereh A1 - Pare, Charles W. P. A1 - Patra, Sarbani A1 - Proudfoot, James A1 - Ruscic, Branko A1 - Ryder, Matthew R. A1 - Sakaushi, Ken A1 - Saßmannshausen, Jörg A1 - Savoie, Brett M. A1 - Schneider, Nadine A1 - Schwaller, Philippe A1 - Skjelstad, Bastian Bjerkem A1 - Sun, Wenhao A1 - Szczypiński, Filip T. A1 - Torrisi, Steven A1 - Ueltzen, Katharina A1 - Vishnoi, Shubham A1 - Walsh, Aron A1 - Wang, Xinwei A1 - Wilson, Chloe A1 - Wu, Ruiqi A1 - Zeitler, Jakob T1 - Discovering structure–property correlations: General discussion N2 - This article is a discussion of the paper "Web-BO: Towards increased accessibility of Bayesian optimisation (BO) for chemistry" by Austin M. Mroz, Piotr N. Toka, Ehecatl Antonio del Río Chanona and Kim E. Jelfs (Faraday discussions, 2025, 256, 221-234). KW - Materials design KW - Machine learning KW - Automation KW - Materials discovery PY - 2025 DO - https://doi.org/10.1039/d4fd90062f SN - 1359-6640 SN - 1364-5498 VL - 256 IS - Themed collection: Data-driven discovery in the chemical sciences SP - 373 EP - 412 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-62208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Boller, Ch. A1 - Mueller, Bernd R. A1 - Heckel, Thomas A1 - Starke, P. A1 - Gohlke, Daniel A1 - Venkat, R. S. A1 - Bruno, Giovanni T1 - Nonlinearities based inverse approach for the characterisation of the damage evaluation process in very high cycle fatigued CFRP specimens N2 - This paper focuses on the aspect on how damage evolution processes in composite materials and structures including matrix fracture, delamination, fibre-matrix debonding, and fibre fracture can be detected by taking advantage of the material’s inherit mechanical properties. These properties can be described on the basis of non-linear mechanical phenomena measurable as an inert frequency response signal. The approach is proposed as a means for residual life structural assessment specifically in the context of VHCF. T2 - The Seventh International Conference on Very High Cycle Fatigue - VHCF7 CY - Dresden, Germany DA - 03.07.2017 KW - Composite materials KW - Damage KW - Non-destructive testing KW - Fatigue KW - Structural simulation KW - Non-linear vibration PY - 2017 VL - 2017 SP - 1 EP - 8 PB - DVM AN - OPUS4-41102 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Siebler, Daniel A1 - Rohwetter, Philipp A1 - Brusenbach, R. A1 - Plath, R. T1 - Optical-only detection of partial discharge with fluorescent polymer optical fiber sensors N2 - This paper reflects recent progress in the field of fluorescent polymer optical fiber sensors (F-POF) for partial discharge (PD) detection in high voltage (HV) cable accessories using optical-only PD detection by coincidence single photon counting. In experiments with artificial PD sources these sensors show the ability to detect optical emissions from picocoulomb-level PDs in a real-scale model of a translucent high voltage cable accessory. False positives (caused by detector noise) are efficiently suppressedwhile maintaining sufficient sensitivity,even when the sensor is located in an unfavorable position. T2 - EUROSENSORS 2015 CY - Freiburg, Germany DA - 06.09.2015 KW - Partial discharge KW - Silicone rubber KW - High voltage cable accessories KW - Polymer optical fiber POF KW - Fluorescence KW - Coincidence PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-337881 DO - https://doi.org/10.1016/j.proeng.2015.08.711 SN - 1877-7058 VL - 120 SP - 845 EP - 848 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-33788 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmann, Daniel A1 - Lucke, T. A1 - Ruhl, A. S. A1 - Winzenbacher, R. A1 - Jekel, M. A1 - Braun, Ulrike T1 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung N2 - Untersuchungen zu biologischen, organischen und anorganischen Veränderungen granulierter Aktivkohlen während der Trinkwasseraufbereitung des Landeswasserversorgers Langenau. KW - Thermogravimetrie KW - Trinkwasser KW - Wasseraufbereitung KW - Aktivkohle PY - 2020 SN - 0083-6915 VL - 118 IS - 2 SP - 47 EP - 50 PB - Wiley-VCH Verlag GmbH & Co. KGaA AN - OPUS4-51434 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Essig, W. A1 - Bernhardt, Y. A1 - Döring, D. A1 - Solodov, I. A1 - Gautzsch, T. A1 - Gaal, Mate A1 - Hufschläger, Daniel A1 - Sommerhuber, R. A1 - Marhenke, T. A1 - Hasener, J. A1 - Szewieczek, A. A1 - Hillger, W. T1 - Air-coupled ultrasound - emerging NDT method N2 - This paper deals with the state of the art of air-coupled ultrasonic testing. KW - Air-coupled KW - Ultrasonic testing KW - Transducers PY - 2021 SN - 1616-069X VL - 173 SP - 32 EP - 43 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-52231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Bernhardt, Y. A1 - Csaszar, L. A1 - Dengiz, N. A1 - Fuchs, M. A1 - Gautzsch, T. A1 - Gohlke, Dirk A1 - Hahn-Jose, T. A1 - Heckel, Thomas A1 - Hillger, W. A1 - Hufschläger, Daniel A1 - Ilse, D. A1 - Kiel, M. A1 - Labud, P. A1 - Schubert, F. A1 - Sommerhuber, R. A1 - Szewieczek, A. A1 - Waschkies, T. T1 - Richtlinie zur Charakterisierung von luftgekoppelten Ultraschallwandlern N2 - Zur Charakterisierung von luftgekoppelten Ultraschallwandlern werden mehrere verschiedene Methoden und Verfahren angewendet. Durch die unterschiedlichen Herangehensweisen werden oft unterschiedliche Prüfkopfpara-meter und Schallfeldgrößen ermittelt, was einen direkten Vergleich von Datenblättern erschwert. Für die Charakterisierung von Kontakt- und Tauchtechnikprüfköpfen hat sich ISO 22232-2:2021 bereits etabliert, allerdings ist diese Norm nicht auf die luftgekoppelten Wandlertechnologien direkt übertragbar. Daher erkannten Hersteller, Forschungseinrichtungen und Anwender den Bedarf an einer Richtlinie zur einheitlichen Charakterisierung von luftgekoppelten Wandlern. Gemeinsam arbeiten sie aktuell im Rahmen des Unterausschusses „Luftgekoppelte Ultraschallprüfung“ der DGZfP an der Erstellung einer solcher Richtlinie mit dem Anspruch, die bestehende Normung um die luftgekoppelte Prüfung zu erweitern und somit die Vereinheitlichung der Charakterisierung dieser Wandler zu erleichtern. In diesem Beitrag wird ein Überblick über den geplanten Inhalt der Richtlinie und über die Methoden zur akustischen Charakterisierung von luftgekoppelten Ultraschallwandlern gegeben. Insbesondere werden verschiedene Methoden der Ermittlung von wichtigen Wandlerparametern wie z.B. Empfindlichkeit, Mittenfrequenz, Bandbreite, Fokusgröße und Fokusabstand dargestellt und verglichen. T2 - DGZfP-Jahrestagung CY - Kassel, Germany DA - 23.05.2022 KW - Lutgekoppelte Ultraschallprüfung KW - Prüfkopf KW - Charakterisierung KW - Richtlinie PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552918 SP - 1 EP - 7 AN - OPUS4-55291 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -