TY - JOUR A1 - Thummerer, G. A1 - Mayr, G. A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias A1 - Burgholzer, P. T1 - Photothermal Image Reconstruction in Opaque Media with Virtual Wave Backpropagation N2 - Thermographic reconstruction of defects that lie in the bulk of a sample is a difficult task because entropy production during heat diffusion leads to information loss. To reconstruct defects one has to solve an inverse heat conduction problem. The quality of the reconstruction is closely related to the information content of the observed data set that is reflected by the decreasing ability to spatially resolve a defect with growing defect depth. In this work we show a 2D reconstruction of rectangular slots with different width-to-depth ratios in a metallic sample. For this purpose, we apply the virtual wave concept and incorporate positivity and sparsity as prior information to overcome the diffusion-based information loss partially. The reconstruction is based on simulated and experimental pulse thermography data. In the first reconstruction step, we compute a virtual wave field from the surface temperature data. This allows us, in the second step, to use ultrasonic backpropagation methods for image reconstruction. KW - Virtual wave concept KW - Thermography KW - Photothermal Technique KW - Image reconstruction PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-506166 DO - https://doi.org/10.1016/j.ndteint.2020.102239 VL - 112 SP - 102239 PB - Elsevier Ltd. CY - Netherlands AN - OPUS4-50616 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ahmadi, Samim A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Burgholzer, P. A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias T1 - Laser excited super resolution thermal imaging for nondestructive inspection of internal defects N2 - A photothermal super resolution technique is proposed for an improved inspection of internal defects. To evaluate the potential of the laser-based thermographic technique, an additively manufactured stainless steel specimen with closely spaced internal cavities is used. Four different experimental configurations in transmission, reflection, stepwise and continuous scanning are investigated. The applied image post-processing method is based on compressed sensing and makes use of the block sparsity from multiple measurement events. This concerted approach of experimental measurement strategy and numerical optimization enables the resolution of internal defects and outperforms conventional thermographic inspection techniques. KW - Super Resolution KW - Laser Thermography KW - Non Destructive Testing KW - Comressed Sensing KW - Inverse Problem KW - Thermography PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519016 DO - https://doi.org/10.1038/s41598-020-77979-y VL - 10 IS - 1 SP - 22357 PB - Springer Nature AN - OPUS4-51901 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lecompagnon, Julien A1 - Ahmadi, Samim A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias T1 - Thermographic detection of internal defects using 2D photothermal super resolution reconstruction with sequential laser heating N2 - Thermographic photothermal super resolution reconstruction enables the resolution of internal defects/inhomogeneities below the classical limit, which is governed by the diffusion properties of thermal wave propagation. Based on a combination of the application of special sampling strategies and a subsequent numerical optimization step in post-processing, thermographic super resolution has already proven to be superior to standard thermographic methods in the detection of one-dimensional defect/inhomogeneity structures. In our work, we report an extension of the capabilities of the method for efficient detection and resolution of defect cross sections with fully two-dimensional structured laser-based heating. The reconstruction is carried out using one of two different algorithms that are proposed within this work. Both algorithms utilize the combination of several coherent measurements using convex optimization and exploit the sparse nature of defects/inhomogeneities as is typical for most nondestructive testing scenarios. Finally, the performance of each algorithm is rated on reconstruction quality and algorithmic complexity. The presented experimental approach is based on repeated spatially structured heating by a high power laser. As a result, a two-dimensional sparse defect/inhomogeneity map can be obtained. In addition, the obtained results are compared with those of conventional thermographic inspection methods that make use of homogeneous illumination. Due to the sparse nature of the reconstructed defect/inhomogeneity map, this comparison is performed qualitatively. KW - Thermography KW - Super resolution KW - NDT KW - Inspection KW - Internal defects PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-548351 DO - https://doi.org/10.1063/5.0088102 SN - 1089-7550 VL - 131 IS - 18 SP - 1 EP - 12 PB - AIP Publishing AN - OPUS4-54835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias T1 - Influence of the number of measurements on detecting internal defects using photothermal super resolution reconstruction with random pixel patterns N2 - In this work, the limits of using spatially structured heating combined with subsequent photothermal super resolution reconstruction for the thermographic detection and resolution of internal defects are investigated. The approach is based on the application of modern high-power laser projector technology, which is used to repeatedly project varying spatially structured 2D pixel patterns to photothermally heat the object under test. After processing the generated thermographic data using nonlinear convex optimisation in conjunction with exploiting the joint-sparse nature of the defect signals within the individual measurements, a high-resolution 2D-sparse defect/inhomogeneity map is obtained. The main focus of the investigation is set on the influence of the number of individual measurements on the achievable reconstruction quality. Using numerical simulations based on an analytical representation of the forward solution to the underlying inverse problem, the convergence rate over performed measurements of the achievable reconstruction quality is determined. Finally, all findings are experimentally validated by reconstructing a set of internal defects in an additively manufactured sample. In this work, it is shown that for a variety of different defect separation distances, the projection of 50 different pixel patterns allows for a good trade-off between experimental complexity and reconstruction quality. KW - Super resolution KW - Digital micromirror device KW - Digital light processing KW - Internal defects PY - 2023 DO - https://doi.org/10.1080/17686733.2023.2223392 SN - 2116-7176 SP - 1 EP - 11 PB - Taylor & Francis AN - OPUS4-57778 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Rupprecht, C. A1 - Ziegler, Mathias T1 - Nondestructive thermographic detection of internal defects using pixel-pattern based laser excitation and photothermal super resolution reconstruction N2 - In this work, we present a novel approach to photothermal super resolution based thermographic resolution of internal defects using two-dimensional pixel pattern-based active photothermal laser heating in conjunction with subsequent numerical reconstruction to achieve a high-resolution reconstruction of internal defect structures. With the proposed adoption of pixelated patterns generated using laser coupled high-power DLP projector technology the complexity for achieving true two-dimensional super resolution can be dramatically reduced taking a crucial step forward towards widespread practical viability. Furthermore, based on the latest developments in high-power DLP projectors, we present their first application for structured pulsed thermographic inspection of macroscopic metal samples. In addition, a forward solution to the underlying inverse problem is proposed along with an appropriate heuristic to find the regularization parameters necessary for the numerical inversion in a laboratory setting. This allows the generation of synthetic measurement data, opening the door for the application of machine learning based methods for future improvements towards full automation of the method. Finally, the proposed method is experimentally validated and shown to outperform several established conventional thermographic testing techniques while conservatively improving the required measurement times by a factor of 8 compared to currently available photothermal super resolution techniques. KW - Thermography KW - Super resolution KW - NDT KW - Inspection KW - Internal defects KW - DMD KW - DLP PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-570551 DO - https://doi.org/10.1038/s41598-023-30494-2 SN - 2045-2322 VL - 13 SP - 1 EP - 13 PB - Nature Research AN - OPUS4-57055 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yagdjian, H. A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias A1 - Gurka, M. T1 - Application of the thermal shock response spectrum (TSRS) methodology to various forms of heat sources by pulse thermography and comparison by using a rotating line scan contour search algorithm N2 - In this paper, we propose a novel contour search algorithm (CSA) for image processing. Its efficacy is evaluated through a comparative analysis with established techniques such as Canny Edge and Snakes: Active contour models, utilizing infrared thermography (IRT) images. Based on the new CSA, we investigate the influence of different pulse shapes on the IRT post-processing methodology, particularly focusing on the thermal shock response spectrum (TSRS), using two different heat sources: xenon flash lamps and a laser. Moreover, this allows for a more precise quantitative comparison of the TSRS with existing IRT post-processing techniques, including pulse phase thermography and thermal signal reconstruction, concerning the detection of defects in composite materials, particularly in carbon fiber-reinforced polymer. A quantitative comparison was performed using the Tanimoto criterion and signal-to-noise ratio. A more detailed analysis is conducted to identify inherent limitations and potential benefits of the new TSRS methodology. We further investigate and experimentally confirm our previous finding on the qualitative correlation between the one-dimensional thermal N-layer model and test data from the TSRS optimization process for defect determination. This correlation can eliminate the time-consuming optimization step, making TSRS a more attractive alternative to common IRT methods and enhancing the quantitative description of defects. KW - Thermography KW - Non-destructive testing KW - NDT KW - Defect identification KW - Laser KW - Contour search PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615056 DO - https://doi.org/10.1063/5.0232015 SN - 1089-7550 VL - 136 IS - 175101 SP - 1 EP - 20 PB - AIP Publishing AN - OPUS4-61505 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Yagdjian, H. A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Gurka, M. T1 - Optimization of thermal shock response spectrum as infrared thermography post-processing methodology using Latin hypercube sampling and analytical thermal N-layer model N2 - In this work, we continue to develop and investigate the Thermal Shock Response Spectrum (TSRS) method as an alternative data processing method for infrared thermography (IRT). We focus on improving the current TSRS algorithm and present an optimization methodology for finding the optimal thermal Q-factor and characteristic frequency pair, which is based on the widely applied random sampling method. We show the qualitative relationship between the determined optimal characteristic frequency and the corresponding maximum difference in diffusion length between reference and defective models, as calculated by selecting a specific one-dimensional thermal N-layer model. The investigations were performed on an inhomogeneous plate made of carbon fiber reinforced polymer (CFRP) with artificial square defects at different depths. Furthermore, two different heat sources were used: a xenon flash lamp and a laser. These sources are not only distinct by their underlying physics but also generate inherently different pulse shapes. To quantitatively estimate the contrast between defect and non-defect areas, and to compare these results with commonly used infrared thermography (IRT) data postprocessing methods such as Pulse Phase Thermography (PPT) and Thermographic Signal Reconstruction (TSR), the Tanimoto criterion (TC) and signal-to-noise ratio (SNR) were used. KW - infrared thermography KW - Composite materials KW - TSRS optimization KW - Defect identification KW - Heat source shape KW - N-layers model KW - Latin Hypercube Sampling PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-614283 DO - https://doi.org/10.1016/j.infrared.2024.105582 SN - 1350-4495 VL - 143 SP - 1 EP - 15 PB - Elsevier B.V. AN - OPUS4-61428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pech May, Nelson Wilbur A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Ziegler, Mathias T1 - Robot-assisted crack detection on complex shaped components using constant-speed scanning infrared thermography with laser line excitation N2 - Infrared thermography (IRT) using a focused laser is effective for surface defect detection. Nevertheless, testing complex‐shaped components remains a challenging task. The state‐of‐the‐art focuses on testing a limited region of interest rather than the full sample. Thus, detection and location of surface defects has been less researched. Most attempts require a manual scan of the full sample, which makes it hard to reconstruct the full scanned surface. Here, we introduce a reliable workflow for crack detection and semi‐automated inspection of complex‐shaped components using IRT excited with a laser line. A 6‐axis robot arm is used for moving the sample in front of the setup. This approach has been tested on a section of a rail and a gear, both containing defects due to heavy use. Crack detection is based on the segmentation of thermograms obtained by Fourier transform of sorted temperatures. Moreover, texture mapping is used to visualize a reconstructed thermogram on the 3D model of the sample. Our approach illustrates a reliable process towards the digitalization of thermographic testing. KW - Crack detection KW - Infrared thermography KW - Laser line excitation KW - Robot‐assisted KW - Texture mapping PY - 2024 DO - https://doi.org/10.1002/appl.202400007 SN - 2702-4288 VL - 4 IS - 1 SP - 1 EP - 13 PB - John Wiley & Sons, Ltd AN - OPUS4-60910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sobczak, M. A1 - Lecompagnon, Julien A1 - Hirsch, Philipp Daniel A1 - Pieczonka, Ł. A1 - Ziegler, Mathias T1 - Impact damage characterization on CFRP parts using laser line scanning active thermography N2 - This study presents a dual-path data processing framework for the detection and characterization of barely visible impact damage (BVID) in carbon-fiber-reinforced polymer (CFRP) structures using laser line thermography (LLT). A robotic LLT system was used to scan impacted CFRP specimens, and the resulting thermal sequences were analyzed using two complementary methods: full thermogram reconstruction followed by Pulse Phase Thermography (PPT) to detect subsurface delaminations, and Time-Summed Gradient Filtering (TSGF) to enhance surface-breaking cracks. Both processing paths produced interpretable results that were fused into a unified combined image and overlay mask, enabling simultaneous visualization of different defect types from a single scan. Quantitative analysis was performed on the binary masks to extract defect dimensions and Signal-to-noise ratio (SNR) values. The results demonstrated that delaminations and multiple cracks could be accurately detected and spatially distinguished, with good agreement to reference methods such as flash thermography and vibrothermography. This work highlights the potential of LLT as a versatile and scalable inspection technique, where multimodal defect detection and segmentation can be achieved through targeted processing and data fusion strategies. KW - Active thermography KW - CFRP KW - Laser line scanning KW - Delamination KW - Cracks KW - BVID KW - NDT PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654097 DO - https://doi.org/10.1016/j.compositesb.2026.113425 SN - 1359-8368 VL - 313 SP - 1 EP - 9 PB - Elsevier Ltd. AN - OPUS4-65409 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kunji Purayil, Sruthi Krishna A1 - Röllig, Mathias A1 - Hirsch, Philipp Daniel A1 - Chaudhuri, Somsubhro A1 - Lecompagnon, Julien A1 - Strobach, L. A1 - Ziegler, Mathias T1 - PCA-enhanced Computational Thermography for the Non-destructive Investigation of the Historic Bücker Bü 181 Aircraft N2 - Infrared thermography is a widely recognized non-destructive testing (NDT) method used in material research and defect detection across various industrial applications. Moreover, thermography plays a crucial role in preserving cultural heritage, including historical paintings and buildings. This study focuses on the application of thermography in inspecting the historic Bücker Bü 181 aircraft, which was used in Germany during World War II. Over time, the original appearance of aircraft has often been altered as part of preservation efforts, either before or during their time in museums, leading to deviations from their historically original state. Additionally, the operational history of such objects is frequently undocumented or entirely lost, making it difficult to understand the presence of artifacts and historically significant data. These factors present major challenges in cultural heritage preservation, and destructive methods cannot be used to investigate such invaluable objects. Therefore, thermography is implemented as a non-destructive and contactless examination method. Active flash thermography combined with phase analysis is a powerful tool for evaluating multilayer systems. In this study, multiple layers of old paint on the object posed a challenge in assessing defect conditions and retrieving other critical information beneath the surface coatings. Nevertheless, pulse thermography not only demonstrated its capability to identify defects and markings in multilayered coatings but also provided insights into the internal structure and subsections of the investigated aircraft. KW - Non-destructive Testing KW - Infrared Thermography KW - Defect Detection KW - Cultural Heritage KW - Multilayer Coatings PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-645709 DO - https://doi.org/10.58286/31934 SN - 2941-4989 VL - 3 IS - 2 SP - 1 EP - 10 PB - NDT.net AN - OPUS4-64570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -